Professional Documents
Culture Documents
Tender Text: Description
Tender Text: Description
Contact
E-mail
Phone
Fax
Customer Project name Untitled project 2021-04-28 16:31:47.364
Project ID
Contact
E-mail
Phone
Date 2021-04-28
DESIGN
For pump type FA 10.26W the design also depends on the
motor!
Please choose a motor in the drop down menues on the
right hand side and read the description in question :
WEIGHTS
Max. weight of the pump end: 72 kg
Weight of the motor: 106 kg
Max. weight of the pump unit: 178 kg
MATERIALS
Project ID
Contact
E-mail
Phone
Date 2021-04-28
MOTOR DATA
Rated power: 7,8 kW
Power consumption of the motor at rated power: 9,9 kW
Current consumption of the motor at rated power: 16,57 A
Number of poles: 4
Rated speed: 1440 1/min
Cos Phi at rated power: 0,86
Cos Phi at starting: 0,55
Efficiency of the motor at rated power: 79 % %
Rated frequency: 50 Hz Hz
Operation type (VDE 0530): S1
Max. temperature of the pumped liquid: 60 °C
Starting current for d-o-l starting: 67,0 A
starting current for star-delta starting: 22,3 A
Starting torque: 92,0 Nm
mass moment of inertia: 0,025 kg m²
max. starts per hour: 15
Motor connection cable: 7x1,5 NSSHÖU
max. possible motor connection cable: 4x25
Project ID
Contact
E-mail
Phone
Date 2021-04-28
Pump
Pump type FA 10.26W Installation type Einhängevorrichtung 1
max. possible 318 mm DN100S/2RK
standard 282 mm Free passage 80 mm
Impeller Ø
designed 282 mm Pressure rating PN10
min. possible 234 mm Suction port Rated diameter DN100
Nominal speed 1450 1/min Standard EN1092-2-S
Frequency 50 Hz Pressure rating PN10
Impeller type Vortex impeller Discharge port Rated diameter DN100
Impeller construction Open Standard EN1092-2-D
Weights
Weight of pump end max. 72 kg Weight of unit max. 178 kg
Weight of motor 106 kg
Materials
Pump housing EN-GJL-250
Impeller EN-GJL-250
Suction ports EN-GJL-250
Motor
Motor name FK 202-4/12 Number of poles 4
Rated power 7,8 kW Rated speed 1440 1/min
Power input with rated power 9,9 kW
Rated voltage 400 ~3 V
Current input with rated power 16,6 A
Efficiency with rated power 79 %
cos phi with rated power 0,86 Rated frequency 50 Hz
cos phi with starting 0,55 Operation type wet S1
Starting current, direct starting 67 A Operation type dry S1
Starting current, star-delta 22,3 A Max. fluid temperature 60 °C
Starting torque 92 Nm Starts per hour max. 15
Inertia moment 0,025 kg m² Degree of protection IP 68
Sel. explosion protection Ex-number ATEX=- / FM=- / CSA=-
Ex-designation ATEX=- / FM=- / CSA=-
Motor connection cable 7x1,5 NSSHÖU
Item no.
Project: Created on: 28.04.2021
Project number: Created by:
Tender text
Submersible Sewage Pump as submersible, single-stage block unit in stationary, vertical installation to pump untreated
sewage which doesn't attack the pump neither chemically nor mechanically. Pump with radially arranged discharge piece
and axial pump intake. Service-friendly design by separated motor and pump casing. Pumping values to be guaranteed as
per ISO 9906 Annex A
Submersible motor in pressure-resistant design, with internal, sealed, active circulation cooling and heat exchanger, double
mechanical shaft seal in EMU block design as well as separate sealing chamber. The motor chamber and sealing chamber are
filled with medical white oil.
Motor sealing at the shaft by a double, wear-resistant mechanical shaft seal independent of the direction on rotation entirely
made of silicon-carbide as closed unit, in EMU sealing cartridge of stainless steel with intermediate separation chamber. Both
seals are cooled and lubricated by medical white oil. The motor chamber is equipped with a terminal board. The motor is
equipped with two maintenance-free ball bearings.
The upper bearing is filled with high-quality grease, the lower bearing is oil-lubricated. Possibility for retrofitting a moisture
probe by means of a pencil electrode for protection against penetrading humidity. All casing parts are of cast iron.
Shaft and connecting elements are of stainless steel. The motor is suitable for continuous operation (S1) under full load in
immerged and completely emerged condition.
Project: Created on: 28.04.2021
Project number: Created by:
Head - Ø 318
H /m ∆ p / MPa
- Ø 306
- Ø 294
- Ø 282 0,36
36 Eff. 48,8%
- Ø 270
48,7%
- Ø 258 0,32
32 - Ø 246
30,34 48,3% 0,297
- Ø 234
49,5% 0,28
28
A1
50,6%
24 0,24
50,3%
49,4%
20 0,2
48,4%
16 0,16
12 0,12
8 0,08
4 0,04
▕◄ Application range ►▏
0 0
Hydraulic efficiency
η/%
40
32,81
30
20
10
0
Shaft power P2
P₂ / kW
12
8
7,086
NPSH-values
NPSH / m
2,305
2,3
2,2
2,1
0 4 8 12 16 20 24 28,17
28 32 36 40 44 48 52 56 60 64 68 72 76 80 Q / m³/h
d
w
a
t
b
s
i
r
q
f
zz
e
z
j
g v
h
x
Dimensions in mm Connections
a 1027 v 13,5 Suction port
b 301 w 571
DN100
c 301 x 90
PN10
d 110 y 260
k 98 z 220 Discharge port
i 225 e 474
DN100
j 50 f 258
PN10
q 206 g 280
r 124 h 506 Einhängevorrichtung 1
s 325 zz 170 DN100S/2RK
t 176