You are on page 1of 4
Testing Electrical Standards Laboratory And R&D Institute Pvt. Ltd. © [81+B2+B3/24, G.L.0.C, Electronics Estate, Soctor-25, Gandhinagar-382024, Gujarat INDIA) TESLA @ M.: +91 72030 25333 /4) 5/6 | 7 (0) 079:29750273, inherently Driven | iy at ” © E-mail: info@teslacentra.co.in @® Website : www.teslacentra.co in Tea secser Calibration Certificate cect Cena to ESLAe/2000/0752 ‘nige ab Report (ut 0] eaas720000000782F Date of Caibvation [06-2020 Tecommanded ner Due One i3-95003 st a fmrc/ao0o7082 Date af sn i-06 2020 Cette se Date 20-06 2020 Date of BUC Receveafi8 06-2020 Betas of customer frame [ra Poms yx aires 539 sheenat stl Ete, aad Batol oad Bako Baran TasDaOT ois medabod Gujrat nda, Pn 382430 fet. Doe No. ,er/PO) acc1800 bate of 206 220 Detlef Dele unde Cattration (DUE) [tomencore [Magnetic ow meter careraton ange [Ove 300 m/e iti Seman asease51 restaion [o0i mre idenicaton no _|Ft_208 sue 100mm moderne [orn aoo0 rake icine conation stove foooa fesiivio __[sre/2000o8a 07/51 eatraton at [ot customersend etal of Calration Master and Traceability [abi Description of Master [raceatitny lUtrasonic Flowmeter, Make: Nagman| Mode: SONICNAG 6000, Size: DNAS. to [DNc000, Serial No. 8180182H, Range: 0 to 2500 ft Details of calibra Hraceable to National Standard through NABL Lab Cert. No CC-25a8| Jchenna,Cestiicate No, 2018-20/CFC-FL/2001/3,Cal Date : 30/07/2019, Vai upto 30/07/2020 lceaoas Procedure and Reference Documents (ab Provedure Method of calibration lab Procedure No. COP/005-@2 The calibration of DUC was caved out by comparhion with Standard Uivasonie Tow] |e by using Calibration Liquid as Water Coliration Method is generally based [NA@L 129-2019 Details of Environment Condition atthe Time of Calibration Temperature 300°C Relative Huriaity ‘8 Rh Temperature of Calibration Liquid 264“ Density of Clioration Liquid 1.020.002 Sp. Gr. [uncertainty of Measurement referent page “The reported expanded uncertainty of measurement i stated asthe standard uncertainty of measurement multiplied by the coverage factor k=2 such that the coverage probability corresponds to 95.45% confidence level CIN : U74900GJ2014PTC078884 GST No. : 244AECT9419R2z! @ M.: +91 72030 26993 1415) 6/7 (0)079.29750273 Testing Electrical Standards Laboratory And (Gex R&D Institute Pvt. Ltd. (gD) eet © (B1+B2+B3)i24, G.L0.C. Electronics Estate, Sector-25, Gandhinagar-382024, Gujarat (INDIA) SS ww erent riven by Quay. © Email: infoBtesacensacoin @ Website: www:tesiacanrecain aoe Calibration Certificate ein Cerne wo [ESLA/C/2000/0752 Unive Lab Repo (ot) o]e285720000008793F Date of Calibration [13-06-2020 Recommended Next Due Date" 13-06-2023 DISCIPLINE = FLUID FLOW CALIBRATION (GROUP : FLOW MEASURING DEVICES Cali ration Result 1.0 Calibration Result of DUC / Eror of Measurement Coliration s performed by considering the Sl unit of Flow L m*/he= 1 m¥/he wee | rstneoometr | rextgonoue | ever | craving | Sts [eon tne nine (mney ow 1 i Sia 5093 razz “oan e130 [300 2 are oy ate “aH z1s0 [2.00 2p econ i989 oan 208 2150 [200 aes 2a 0338 aaa 215020 5p s8505 ae “aa 02 2150 [200 General Remarks ‘Reporting of DUC/Master Reading isan average of te readings ‘The reading has been rounded off wherever applicable ‘= Calibration is performed without doing any adjustment nits eriginal condition at time of recipt/calibraton, unless mentioned hecein ‘= The calibration resus relate only to the item calibrated and result reported in the certificate are valid atthe dane of and under the stated conditions of measurement. ‘The Calibration certificate shall nt be reproduced except i ful, without writen permission ofthe Laboratory ‘**Recommended Next Oue Datei reported ae per requisition of customer End of Certificate CIN : U74900GJ2014PTC078884___ GST No. : 24AAECT9419R2ZK Testing Electrical Standards Laboratory And R&D Institute Pvt. Ltd. ~ © (81+82+89/24, 6.10.0. Electronics Estate Socor:25,Gandhinagar-382024, Gujarat (NDIA) TESLA @ M.: +91 72030 25333 /4/ 5/6 | 7 (0)079-29750273 Inherently Driven by Quality © E-mail: info@teslacentre.co.in @ Website : www.teslacentre.coin ‘Teaont/ecae6r Calibration Certificate ere re ea Unie ab Report (at eC28S7R0000007aRF Date of carson fz a6-020 Teconmendad Wer Ove Ove fiF 462004 snr frer000 708 Date of se506 2020 Date of UC Recess 062000 Details of Customer [name [ALFA Pumas (pp LTD ladaress [58 59, Shreenethj industrial Estate, Kujad-Bakrol Road, Gakrol (Bulrang), Ta-Daskrol, Dist :ahmedabad, Gujarat, India Pin 382430 et. Doe. No. (GP/PO} [aoox200 [Date oF Doe. 12-06-2020 DDetalls of Device under Calibration (0UC) [Nomenciature [Magnetic Flow meter [atibration Range [0%0 30 mir Mie. serio fasaosza2 Resolution lo.01 m/w identitication No [FT_a0% size [50 mm iodet No Jorn 2000 hake krone [condition ofouc [aoa [Festa 10610 [snrc/20007082-1008/5T [cabraton at fat Customer's end Details of Caloration Masters and Traceability [seo Description of Master [Traceability lUnrasonieAowmeter, Waker Nagman| Model: SONICNAG 6000, Size: DNS to loN6000, Serial No, 8180182H, Range: 0 to [500 the Detalls of Calibration Procedure and Reference Documents [Traceable to National Standard through NABL Lab Certf, No ¢C-2548) chennai, Certificate No. 2018-20/cFC-F1/1001/1,Cal Date : 30/07/2019, Vai luo to 30/07/2020 ceaoss Lab Proceaure [Method of Cabration Tab Procedure No, COPTO05-02 The callration of DUC was carried out by comparison with Standard Unasonic ow meter by using Calibration Liquid as Water Calibration Method is generally based |aa 129-2019 Details of Environment Condition atthe Time of Calration Temperature 306°C Relative Humidity a6 %RW Temperature of Calibration quid 264°C Density of Calibration Liquid 1.0. 0.002 Sp. Gr. Uncertainty of Measurement rofer next page "The reported expanded uncertainty of measurement is stated asthe standard uncertainty of measurement multiplied by the coverage factor k=? such that the coverage probability corresponds to 95.45% confidence level Revi Bauthorized by CET eRe aA: CISL CREEL EVASR Caer and Testing Electrical Standards Laboratory And R&D Institute Pvt. Ltd. ~ @ (81+B2+ 839/24, 6.1.0.C, Electronics Estate, Sector 25, Gandhinagar-382024, Gujarat (NDIA) TESLA @ M.: +91 72030 25333 /4, 5/6) 7 (0)079.29750273 Inherently Driven ar © Email: info@teslacentre.co.in @ Website : www.teslacentre.co.in ‘Yea0 e030? Calibration Certificate ele entire wo [ESLA/C/2000/0793 Unique Lab Repor (uta eaas720000000783F Date of Carton [6 2020 Recomended Nex ove ate" ['-06 2021 DISCIPLINE ; FLUID FLOW CALIBRATION ‘GROUP : FLOW MEASURING DEVICES Calibration Result 1.0. Calibration Result of DUC / Error of Measurement Calibration is performed by considering the Sl unit of Flow 3 mh = 3 m/e seme | retneon ater] tenrgenouc | enor | cron tet | ae (mya) Lmfhe) (mar) (%) (%) z Saar sa ase 27a0 2130 | 200 2 3097 398 0088 0538 zis [200 2 Tear 7976 “aaa 0H zis [200 a eh a7 “oar “ore e150 [200 5 ras za 008 roo =is0 [200 General Remarks ‘© Reporting of DUC/Master Reading isan average of five reaings ‘The reading has been rounded off wherever applicable ‘* Calibration i performed without doing an adustment in its criginal condition at tine of receipt/calibration, unless ‘mentioned herein ‘The calibration results relate oly tothe item calibrated and result reported inthe certificate are valida the time of and under the stated conditions of measurement, ' The Calibration certificate shall not be reproduced except in ful, without written permission ofthe Laboratory *# *Recommended Next Due Datei reparted as per requisition of customer End of Certificate (Winod fetadiya / AnktFain) Fech. Mangge*/Director i 4 AAECT9419R2ZK 4900GJ2014PTC078884 GST No.

You might also like