AD11A.1/AD11A.2/AD11A.8 KWh
Kvarh
Active energy (export/import)
Reactive energy (4 quadrants)
VAh Apparent energy
DIRECT CONNECTED
MULTI-FUNCTION & MULTI-TARIFF V True RMS voltage
SINGLE-PHASE ELECTRONIC METER A True RMS current
DESIGNED
FOR USE IN AMI/AMR SYSTEM
Power quality indices

OVERALL VIEW
Built-in real time clock

Event Log

Profiles

IP54 Protection level

Backup power supply

Standard data model,


open protocols

Optical port

Basic and extra relay

DISPLAY INDICATIONS Sensor of meter cover opening

Sensor of terminal block cover


opening

Magnetic field sensor

Interfaces for local and remote


communications

Authentication & Encryption

© 2020 All Rights Reserved www.addgrup.com


FUNCTIONALITY

DLMS/COSEM SUPPORT METER PARAMETERIZATION INFORMATION SECURITY


• Standard data model • Remote (via communication • Communication encryption
• Standard communication protocols channel) or local (via optical port) (AES-GCM-128 security suite)
• Interoperability. • Access rights assignment from HES • Data access according to
Events registering. access rights stated
MEASURED QUANTITIES
• Firmware protection
• Active energy, class B, export/import; EVENTS & ALARMS HANDLING
• Events registering.
• Reactive energy, class 2, 4 quadrants • Continuous control of current state
• Apparent energy; of meter functional nodes and METER SELF-CONTROL
• Active/reactive power, apparent alarms/events • Built-in test for continuous
power; • Standard set of events processing self-control
• Phase voltage/current, including: registration in special • Quick response on severe error
instantaneous value (True RMS, logs and registers, event report • Events registering.
integration period 1 s) sending, states displaying
DATA TRANSMISSION
• Voltage angle values relative to the • Different types of event logs
• Data transmission on demand
voltage in first phase and phase • Asynchronous sending of Event
or by schedule
currents relative to relevant phase Notification can be configured for
• Request types:
voltages. specific events.
- Remote HES request
METERING DATA OPERATING MODES (via communication channel)
• Actual meter readings • Normal mode - Local Hand Held Unit request
• Periodic (billing) meter readings: • Energy saving mode - real time (via optical port).
Day, week, decade, month clock, opening sensors, and data
SOFTWARE UPGRADE
• Interval meter readings: displaying are active.
• Remote (via communication
15’, 30’, 60'
POWER QUALITY CONTROL channel) or local (via optical port)
• Timestamp.
• Quality indexes: • Image Block Transfer Mechanism is
MULTI-RATE METERING - average voltage used.
• Up to 6 tariff registers, flexible - voltage sags and swells
POWER LOAD CONTROL
adjustment of tariff intervals - outages
• Basic relay (80-100 A)
• Up to 12 changeovers per day - network frequency
• Control modes:
• Tariff indicator is displayed on LCD - THD for voltage/current harmonics
- remote (by command)
and transmitted to an external • Remote or local configuring of
- local (by schedule)
system parameters thresholds and control
- manual - by push button
• Active and passive tariff plans, actions
• Basic relay status displayed on the
configurable activation time of the • Events registering.
meter LCD
passive tariff plan.
THRESHOLDS MANAGEMENT • Up to 2 extra relay (5 A) to control
CALENDAR • Threshold for active power, active external contactors of consumer’s
• Up to 12 seasons per year power demand, current/voltage appliances
• Up to 7 daily profiles per week (per phase), differential current • Events registering.
• Up to 30 special days per year (direct connected meters only)
BUILT-IN CLOCK
• Support of movable holidays. • Remote or local configuring of
• Real Time Clock (RTC),
parameters thresholds
DATA STORAGE accuracy 0,5 s. per day
• Possibility to disconnect consumer
• Non-volatile memory; • IEC 62052-21 standard compliant
from the network, when a threshold
• Capacity depends on data type • External synchronization.
is crossed
and number of parameters;
• Events registering. BUILT-IN DISPLAY
• Up to 3 interval profiles and 1
• LCD, 8 digits, configurable
billing profile. For example: FRAUD & THEFT PROTECTION
decimal place (up to 3 digits)
- 15 minutes interval profile: • Continuous monitoring,
• Special symbols,
6 parameters for about 63 days including sleep mode time
data identification according
- hourly interval profile: • Fraud types under control:
to IEC 62056-61 (OBIS)
6 parameters for about 13 days - meter cover opening
• Service and client lists of
- monthly billing profile: - terminal block cover opening
parameters to be displayed
6 parameters for about 110 - inadmissible differential current
• Manual and automatic modes of
months - reverse meter connection;
screens scrolling
• Voltage&current profile for 10-min - detection of strong external
• Display self-testing
RMS phase voltage/current based magnetic field
• Configurable backlight mode.
parameters – 15 days • Reed switch for magnetic field
• Power quality profile, for example detection TEST OUTPUTS
for week measuring period – 6 • Events registering. • Outputs: 2 optical outputs (LEDs),
weeks optical port
• Asynchronous profile, last entries. • Parameters under control:
• Based on FIFO mechanism. active energy, reactive energy.

© 2020 All Rights Reserved www.addgrup.com


FUNCTIONALITY

BACKUP POWER SUPPLY OPTIONAL INTERFACES FOR LOCAL


• Supports clock/meter operation OR REMOTE COMMUNICATION OPTICAL PORT
when the power is off • RF Communication: • IEC 62056-21 standard compliant
• Supercapacitor/Battery - Built-in RF modem with • Data transmission rate – up to
• Battery lifetime - not less than 15 internal antenna 115200 bps
years. - Provides communication • Access rights determined by
channel between the meter security features on access levels
PUSH BUTTON
and HES as a part of hybrid • Password protected
Used for different purposes:
PLC+RF solution • Possibility to block logging after a
• To manually disconnect/reconnect
- Modulation: FSK number of failed login attempts
the customer’s load
- G3-PLC compliant MAC layer • Intended for direct data exchange,
• To scroll the meter screens
- Upper layers: 6LoWPAN, IPv6, meter parameterization and
• To view on data LCD when the
UDP, DLMS firmware upgrade.
power is off.
- Carrier frequency: MHz
POWER LINE COMMUNICATION (PLC) subrange.
• Built-in OFDM PLC modem
• RS-485 interface:
• ITU-T G.9904 (PRIME), ITU-T
- Meets EIA/TIA-485A standard;
G.9903 (G3-PLC) standards
- Baud rate - up to 38400 bps;
compliant
- Provides communication with with
• PLC features:
external devices
- CENELEC A Band and FCC Band - Serves as a link between the
- EMC standards compliance meter and the extension
- Auto-discovery communication module
- Repeating. - Placed under the meter terminal
block cover.

METER FIXING ELEMENTS AND DIMENSIONS

127,5
155
140
224

105

© 2020 All Rights Reserved www.addgrup.com


TECHINCAL SPECIFICATIONS TERMINAL BLOCK DIMENSIONS

Accuracy class:
- Active energy B (1)
- Reactive energy 2
Reference current, Iref
5/10 А
(depending on the meter model)

Maximum current, Imax


60/80/100 A
(depending on the meter model)
Minimum current:
- Active energy 0.05 Iref
- Reactive energy 0.05 Iref

Starting current:
- Active energy 0.004 Iref
- Reactive energy 0.005 Iref
CONNECTION DIAGRAM
Reference voltage, Un 1×120/208 V;
(depending on the meter model) 1×230/400 V;

Voltage range 0.7 Un ... 1.2 Un


Reference frequency 50 Hz (± 2 %)
Meter constant:
- Active energy 500/1 000 imp/kWh
- Reactive energy 500/1 000 imp/kvarh

Temperature range -40°C … +70°C IEC


Internal clock quartz crystal 32 kHz
Clock accuracy (at 25°C) (IEC 62052-21) ≤0.5 s /24 h

Communication interfaces bit rates up to 21-64 kbps (PRIME)


(with coding, on physical layer) 20-46 kbps (G3-PLC)

Inherent consumption of current circuit,


1 VA
not more (IEC 62053-61)
Inherent consumption of voltage circuit,
active/total, per phase, 2 W / 10 VA
ANSI
not more than (IEC 62053-61)
DESIGN FEATURES
Insulation strength (IEC 61010-1-90) 4 kV, 50 Hz, 1 min
Shock voltage (IEC 60060-1) 8 kV, 1.2/50 μs DESIGN
• Compliance to DIN 43857 standard
Electrostatic discharge (IEC 61000-4-2) 15 kV specifications
High frequency radiant field HOUSING
≥ 30 V/m • Light-tone non-flammable
(IEC 61000-4-3)
polycarbonate
High frequency interferences
4 kV MOUNTING
(IEC 61000-4-4)
• By 3 fixing points or on DIN rail
Surge immunity test (IEC 61000-4-5) 6 kV (35 mm)

IP rating IP54 CONTACT US


Mechanical class M1
36, Dragomirna str.
Electromagnetic class E2 Chisinau, MD-2008,
Republic of Moldova
Mean total lifetime, not less 20 years
MTBF, less than, per year 0.5 % Phone : +373 (0) 22 930012
Fax : +373 (0) 22 930012
Dimensions 127.5 x 213,5 x 62 mm
E-mail : info@addgrup.com
Web : www.addgrup.com

© 2020 All Rights Reserved www.addgrup.com


SELECTION GUIDE

AD11A.1 AD11A.2 AD11A.8


Parameters
7-1 8-1 9-1 10-1 11-1 12-1 13-1 14-1 15-1 16-1 17-1 3-1 10-1
1×230
Unom, V
1×120

Inom, A 5
60
Imax, A 80
100

50
Fnom, Hz
60

80
Basic relay, A
100

Additional relay

Battery
Power backup
Supercap.

PRIME, G3-PLC
Main comm.
channel
Hybrid PLC-RF

RS-485-1 RS-485-1
Extension comm. port RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 RS-485
RS-485-2 RS-485-2
– replaceable battery
– negotiable option, up to 2 additional relays

© 2020 All Rights Reserved www.addgrup.com