Modular meters

ST100

Three-phase modular meter for residential consumers


with plug-in communication and switching modules

ST100 is a three-phase modular meter designed for direct connec- plug-in communication module (CMxyS - PLC or GPRS/3G) and
tion to grid and measurement of energy consumption of residen- switching module (SD30S) via M-Bus connection. Both plug-in
tial consumers. ST100 can also be implemented in single-phase modules are simply mounted under the terminal cover. ST100 is
networks. AMI system integration is enabled by connecting optional compliant with all relevant standards and regulations.

Key features

— Measurement of electrical values — Event logs


— Integrated Real-time clock with DST — Measurement of energy quality
— Flexible tariff policy with up to 4 tariffs — Firmware update
— Maximum demand — Functional inputs/outputs
— RS485 port — Data security
— Optical port
— DLMS/COSEM
— Fraud detection
— No-power reading and parametrization
— Billing profile / profiles
— Load profiles
— Power limit
— Code red
Technical data ST100

Measurements Optical port Log books Firmware update


• Measurement of power and energy • Physical layer according to • Standard log book with up to 200 • Enabled locally or remotely with
in both directions and absolute val- IEC 62056-21 logs and states no impact on accuracy, parameter
ues (A+, A-, |A|), R+ and R- optionally. • DLMS/COSEM communication • Energy quality log book configuration or billing data
• Active energy measurement – Index protocol • Fraud detection log book
classes 1 and 2, reactive energy mea- • Disconnector control log book No-power reading
surement (optional) - Class 2 or 3 Electrical ports (physical layer) • Local reading via display or optical port
• Measurement of voltages and • Port A: RS 485 for communication Energy quality measurement
currents by phases, frequency and with AMI Center (active) • Maximum and minimum voltage Integration into AMI system
power factor • Port B: M-Bus master (for commu- registration Communication with AMI system
nication with the switching module • Voltage variation registration • ST100 is ready for addition of plug-in
Maximum demand and other energy meters) in accor- • Maximum current registration communication module (PLC or
• Programmable maximum demand dance with EN 13757-2 • Outage registration (short outage – GPRS/3G) on port A
integration period is generated by Event counter, long outage – Long Load management
internal clock (typically 1, 5, 10, 15, Inputs and outputs (optional) power interruption log) • ST100 is ready for addition of plug-in
30 or 60 minutes) • 2 control inputs for tariff control • Under-voltage and over-voltage switching device on port B
• 2 tariff outputs (100 mA) measurement and registration in • Switching device in accordance with
Multi-rate registration and TOU • 2 pulse outputs Quality Event log book IEC 62055-31, UC2/UC3
• Programmable tariff structure (up to • 1 control output with bi-stable relay
4 tariffs) (5 A) Fraud detection Data protection
• Up to 4 seasons and 4 weekly • Detection of meter cover opening / • Local parameterization is protected
changeovers Communication protocol closing by multi-level passwords and push
• Up to 9 day types and 32 holidays • Optical port and port A: DLMS • Detection of terminal block cover button positioned under terminal
• Up to 10 daily changeovers (IEC 62056-46) opening / losing block cover
• Port B: M-Bus (EN 13757-3) • Detection of wrong authorization for
Internal Real-time clock with DST meter parameterization Meter quality
• In accordance with IEC 62054-21 Billing profiles • Detection of strong magnetic field • High accuracy and long term stability
• Automatic DST switching (optional) • Billing profiles (registered energy • Detection of neutral conductor of metering elements. No recalibra-
• Battery backup supply, optionally and maximum demand values by interruption tion required during meter lifetime
super-capacitor tariffs) are generated and stored for • Recording of events in the Fraud • High meter reliability
the last 18 billing intervals event log book • High immunity to EMC
Visual communication with meter
• LCD and display modes according to Load profiles Power limiting (optional) Current terminal block
VDEW specifications • 4 load profiles with 7 channels each • Power or current limiting of electric- • For current up to 60 А: for all types
• Programmable selection of data and • Independent, programmable registry ity consumers by defining the limit of conductors up to 16 mm2
display sequence intervals (5-60 minutes, 1-24 hours) value of power or current in the • For current up to 100 А: for all types
• LED: 1000 imp/kWh / kvarh) • Sufficient memory (4 320 registries, dedicated meter register of conductors up to 35 mm2
• 2 push buttons on the meter cover i.e. 15-minute average load profile • Dedicated log book (10 switching
• OBIS data ID code: IEC62056-61 (1 channel) is stored for 45 days module disconnections / connec- Compact meter case
tions) • Dimensions and mounting points
according to DIN 43857
Code Red (optional) • High quality, transparent, reinforced,
Accuracy class • Enables synchronous power limiting self-extinguishing polycarbonate
of groups (large number) of users in case
active energy 1 or 2
case of irregular situation on distri- • IP54 protection against water and
reactive energy 2 or 3 bution network (e.g. lack of power) dust (in accordance with IEC 60529)
Nominal/maximum current 5 (60) A, 5 (120) A
Minimum current Imin 0.05 In
Nominal voltage, Un 3x230/400 V, 3x400 V, 230 V
Voltage range 0.8 Un – 1.15 Un
frequency 50 Hz
Ports
optical port IEC 62056-21 (physical layer)
IEC 62056-46 (DLMS) comm. protocol
154,5
142

port A RS485
IEC 62056-46 (DLMS) comm. protocol
port B wired M-Bus master (EN 13757-2)
EN 13757-3 comm. protocol
272,9

Comm. module (optional) PLC, GPRS/3G


Switching module (optional) 3x230 V (3x90 A; 3x120 A), IEC 62055-31, UC2/UC3
Self-consumption <2W
Insulation voltage 4 kV, 50 Hz, 1 min
127,2

Shock voltage 6 kV; 1.2 / 50 µs


Operational temperature range -40 °C - +70 °C
Storage temperature range -40 °C - +80 °C
IP protection IP54, according to IEC 60529
Dimensions 273 x 177 x 91 mm 150 90,8
Weight 0.9 kg 178,9

Meter&Control d.o.o. | Science Technology Park Belgrade


Veljka Dugoševića 54 | 11050 Belgrade | Serbia
office@meterandcontrol.com | www.meterandcontrol.com Solutions for smart energy management