You are on page 1of 4

NJ Grid for Power Grid

Grid meter for power exchange


The NJ34-105-05S meter can provide with comprehensive
solutions for the grid-connected C&I metering applications

Key Benefits

Bi-directional Metering

Quadrant Measurement

Power Quality Monitoring

Site-Watch Instrumentation

3-Concurrent Communications

Bi-directional Metering Communications


For the PX application, the meter can provide with the uni- The meter can provide the 3-different communication ways
directional and bi-directional metering capabilities: for in-site, local and remote data exchanges.
- Up to 8-metering channels With the IEC-type optical port, the mete can be configured
- Import, Export, & NET measured quantities and read at an installation site.
- Up to 6-self reads for revenue metering - Up to 19,200-baud
- 4-tariff TOU metering For local and remote data exchange, the meter can provide
with the RS-232 and RS-422/485 ports.
- Up to 38,400-baud for RS-232 & RS-422/485
Quadrant Measurement
- Multi-point network and up to 32-nodes for RS-485
With the user-configured measurement, the meter can
measure and record energy and demand based on the Load Profile Capacity
vector-sum or scalar measurement.
- Q1/2/3/4 kW(h) and kvar(h) For an interval metering, the meter measures and records
- User-defined calculation of PF an user-defined interval data into a non-volatile memory:
- kW(h)/kvar(h)/kVA(h) with date & time stamp
Power Quality Monitoring - Up to 50-days for 8-channel/5-minutes
- Status event of an interval data : power fail, DR & etc.
With the PQM capability, the meter continually performs a
complete diagnostics analysis on the metering installation
Self Diagnosis & Event Log
equipment, the service wiring, and the load characteristics:
- Polarity, energy flow, cross phase To ensure the reliable meter operation, the meter detects
- Current imbalance, inactive phase current and indicates the faulty conditions. Also the meter records
- Voltage imbalance, under/over voltage the event log into a non-volatile memory:
- Voltage & Ampere THD - Time adjustment, DR/SR/MDR, error-status, power
- Neutral current failure/restore

Site-Watch Instrumentation External Output


With instantaneous displays of metering values, utilities and
The meter provides an external output which are the open
their customers will be able to analyze electrical service at
collector & Opto-MOSFET and is programmable by user:
the moment of delivery:
- Pulse output : kWh, kvarh, time switch (DC 24V/20mA)
- Per-phase value : kW, kvar, kVA, Vrms,, Irms, Angle, THD
- Control output : load control (AC 240V/90mA)
- Graphical software tool : vector-diagram, trace-box

1
For C&I AMI Customers in the Smart Grid Market,
the NJ grid meter will be waiting for your best choice…

Dimensions : NJ34-105-05S

Specifications and Technical Data : NJ34-105-05S


Voltage 3x110V (±10% of nominal voltage)
Current 5(6)A
Frequency 60 Hz (±5% tolerances)
Temperature -25ºC to +55 ºC (operating range)
Humidity 0 to 100% (non-condensing)
Power consumption Less than 2W
Accuracy With full load and light load ±0.5% for kWh
With full load and light load ±1.0% for kvarh
Starting current Conforms to the IEC requirements (less than 0.001In)
Creep No more than 1 pulse per measured quantity
Startup delay Less than 3 seconds from power application to pulse accumulation
Clock Built-in real time clock with a backup battery
Communication Optical communication up to 19200 baud
Remote communication up to 38400 baud
Standards IEC 62052-11 Electricity metering equipment (a.c.)-General requirements, tests and test conditions
-Part 11: Metering equipment
IEC 62053-22 Electricity metering equipment a.c.)-Particular requirements
-Part 22: Static meters for active energy (classes 0.2S and 0.5S)
IEC 62053-23 Electricity metering equipment a.c.)-Particular requirements
-Part 23: Static meters for reactive energy )classes 2 and 3)

2
NJ Advanced for HV
Advanced meter for high voltage
The NJ34-105-05 meter can provide the advanced and versatile
metering solutions for the commercial & industrial AMR & AMI

Key Benefits

Quadrant Measurement

Time-of-Use Metering

Load Profile Capability

Remote Communication

External Output

Quadrant Measurement Communications


With the user-configurable measurement, the meter can With an ANSI C12.13 compatible optical port, the meter can
measure and record energy and demand based on the be programmed and read at an installation site
vector-sum or scalar measurement - Baud rate=1200 to 19200 can be selectable
Also, the meter can provide with the unidirectional and For a remote communication, the meter provides a RS-232C
bidirectional metering capabilities: interface with an external PSTN and CDMA modem
- Up to 4-metering channel - Baud rate=1200 to 19200 can be selectable
- Q1/2/3/4 kW(h), kvar(h), & kVA(h) - Modem initialization string can be configurable
- Unidirectional or bidirectional metering (optional)
- User-defined calculation of PF Site-Watch
With the meter field software and the LCD display items in
Time-of-Use Meter the diagnostic display mode, the technicians can test and
By adopting a large-scale memory, the NJ34-105-05 meter verify the installation and operation of the meter:
provides with the extended TOU metering alternatives for - Per phase measurement : kW, kvar, kVA, Vrms, Irms, Angle
the heavy load customers such as commercial & industrial - Graphical software tool : Vector diagram
applications:
- Up to 4-tariff metering Self Diagnosis & Event Log
- Up to 6-self reads(energy, demand, & PF)
To ensure the reliable meter operation, the meter detects
- Support daily/weekly/holiday profile
and indicates the faulty conditions. Also, the meter records
- Support TOU pending program
the event log into a non-volatile memory:
Load Profile Capacity - Up to 16-records per each event
- Up to 6 events
For an interval metering, the meter measures and records : Time-adjustment, DR, SR, MDR, error, & power failure.
the LP interval data into a non-volatile memory:
- Up to 4-channel (8-channel optional) with time stamp External Output
- Up to 90-days for 4-channel/15-minutes
The meter provides with the three-programmable outputs
- Status event of an interval data
for a user-specific application such as a load control and
: Power failure & restoration, manual demand-reset
a time-switch:
time-adjustment, season-change, program-change,
- Up to 3-output (open-collector)
battery replacement, & potential error
- User-configurable output 3
: kWh/kvarh pulse, time-switch, load control
For Commercial & Industrial AMR & AMI Customers in the Deregulated
Market, the NJ advanced meters are waiting for your best choice…

Dimensions : NJ34-105-05

Specifications and Technical Data : NJ34-105-05


Voltage Auto-range, 63.5 to 380V
Current 5A
Frequency 60 Hz (±5% tolerances)
Temperature -25ºC to +55 ºC (operating range)
Humidity 0 to 100% (non-condensing)
Power consumption Less than 2W
Accuracy With full load and light load ±0.5% for kWh
With full load and light load ±2.0% for kvarh
Starting current Conforms to the IEC requirements (less than 0.002In)
Creep No more than 1 pulse per measured quantity
Startup delay Less than 3 seconds from power application to pulse accumulation
Clock Built-in real time clock with a backup battery(3.6V/1,200mAh)
Communication Remote communication up to 9600 baud (upgradeable)
Standards IEC 62052-11 Electricity metering equipment (a.c.)-General requirements, tests and test conditions
-Part 11: Metering equipment
IEC 62053-21 Electricity metering equipment a.c.)-Particular requirements
-Part 21: Static meters for active energy (classes 1 and 2)

IEC 62053-22 Electricity metering equipment a.c.)-Particular requirements


-Part 22: Static meters for active energy )classes 0.2S and 0.5S)
IEC 62053-23 Electricity metering equipment a.c.)-Particular requirements
-Part 23: Static meters for reactive energy )classes 2 and 3)
ANSI C12.13 American National Standard for Electronic Time-of-Use Registers for Electricity Meters