You are on page 1of 2

Integrated smart meters

Sx405D

Three-phase and single-phase smart meter with integrated


RS485 communication port and switching device

SM405D/ST405D
RS485 integrated communication port
and switching device

Sx405D are three-phase and single-phase smart meters designed for utilities for having insight in overall condition of low voltage
for measurement of electrical energy of residential consumers, network. RS485 port allows local communication with meter and
with RS485 port and integrated switching module. They support remote communication with HES by connecting several meters to
both prepaid and postpaid mode. In prepaid mode, option for RS485 bus communicating with the center over Ethernet/RS485
credit recharge over optical port is supported. Wide range of gateway or similar. All functions are compliant with the following
measurement values including power quality data in combination specifications and standards: IDIS, DLMS/COSEM, IEC 62052-11, IEC
with large capacity of load profiles makes these meters a key tool 62053-21/22/23, EN 50470-1/3 (MID), and M-Bus.

Key features

— Measurement of electrical values — Billing profile


— RS485 communication port for two-way communication — Fraud profile
— Internal real-time clock with DST — Load profiles
— Flexible tariff policy with up to 8 tariffs — Power limit
— Maximum demand — Event logs
— 230 V/50 Hz or 110 V/60 Hz supported — Measurement of energy quality
— Optical port — Firmware update
— Variety of additional input/output options available on demand — Prepaid supported
(relays, pulse outputs, inputs e.a.) — Functional inputs/outputs
— MID certificate — M-Bus port for G, W, H meters reading
— DLMS/COSEM (Wireless M-Bus on demand)
— Fraud detection — Support for in-home customer display
— No-power reading and parameterization — High level data security
Technical data Sx405D

Measurements customer specification Load profiles limit value of power or current in


• Measurement of power and energy • Exact configu­ration is defined with • 4 load profiles for measured values dedicated meter registers
in both directions and absolute customer according to specific or- • 4 M-Bus profiles for registration of • Programmable Tolerance time and
values (A+, A-, |A|, R+, R-, R1, R2, R3, der prior to manufacturing process measured data from other types of Penalty time
R4, S+, S- and by quadrants) measuring devices (multi-utility)
• Measurement of energies, voltages Prepaid support • Programmable and independent Code Red
and currents per phase, network • Both Prepaid and postpaid modes registration periods (5, 10, 15, 30, • Enables synchronous power limiting
frequency and power factor are supported. In prepaid mode 60 minutes and 24 hours) of groups (large number) of users in
alarm credit features and credit case of irregular situation on distri-
Maximum demand recharge over optical port are Log books bution network (e.g. lack of power)
• Programmable maximum demand supported • Standard log book
integration period (typically 5, 10, • Fraud detection log book Data security
15, 30 or 60 minutes) Optional RS485 ports • Disconnector control log book • High level data security includ­ing
• Meter supports up to 2 RS485 ports • Long power interruption log authentication and data encryption
Multi-rate registration and TOU • RS485 port 1: allows local communi- • 4 M-Bus event logs which records
• Programmable tariff structure cation with meter, data reading and events from other measuring Firmware update
(up to 8 tariffs) meter parameterization. Suitable for devices which are connected to • Firmware is separated to Metrol­
connection of up to 31 meters into M-Bus port ogy and Applicative part accord­ing
Internal real-time clock with DST single communication loop. Half-du- to Welmec 7.2, which allows safe
• In accordance with IEC 62054-21 plex RS485 bus with 9600 bit/sec Energy quality measurement update of applicative part of the
• Automatic DST (Daylight Saving communication speed • In accordance with EN 50160 firmware without need for addition-
Time) switching • RS485 port 2: used for wired con- • Voltage variation registration al meter verification after firmware
• Backup battery supply nection of In-Home Display (IHD); • Outage registration (short outage – update
(optionally super-capacitor) supports unidirectional communica- Event counter, long outage – Long • Firmware update can be done local-
tion with IHD; sending consumption power interruption log) ly and remotely with no impact on
Visual communication with meter data and consumer messages • Under-voltage and over-voltage accuracy, parameter configuration
• Programmable selection of data and measurement and registration in or billing data
display sequence Integrated switching module Quality Event log book
• LED (1000 imp/kWh/kvarh) (optional) • Voltage THD and current THD No-power reading (optional)
• Bi-stable switching module placed registration • Local reading via display or via
Optical port under meter cover for remote or optical port in no power condition
• Physical layer in accordance with local connection/disconnection Fraud detection • Integrated battery supply
IEC 62056-21 • Phase current break up to 100 A, • Detection of meter cover opening/
• Communication protocol - DLMS/ whilst neutral stays closed closing Current terminal block
COSEM • In accordance with IEC 62055-31, UC3 • Detection of terminal block cover • For current up to 100 А
• Minimum 10 000 mechanical dis- opening/closing • For all types of conductors up to
M-Bus micro master port connections/reconnections under • Detection of wrong authorization for 35 mm2
• Suitable for connection of gas, water maximum load meter parameterization
or heat meters and in-home display • Detection of strong magnetic field Compact meter case
• Physical layer in accordance with EN Billing profiles • Detection of strong EMF • Dimensions and fixing points in
13757-2 (wired M-Bus), communica- • Billing profile 1: recording billing • Detection of neutral conductor accordance with DIN 43857
tion protocol EN 13757-2/3 data at the end of the programma- interruption • High quality, transparent, rein-
ble billing period with automatic re- • Recording of events in the Fraud forced, self-extinguishing polycar-
Inputs and outputs set of maximum demand. Program- event log book bonate case
• Multiple configurations of 230 V, mable with up to 32 channels • IP54 protection against water and
5 A relays, low voltage and high • Billing profile 2: recording billing Power limiting dust (in accordance with IEC 60529)
voltage inputs/outputs for different data in case of fraud detection with- • Power or current limiting of elec-
functions, available according to out reset of maximum demand trical consumers by defining the

Accuracy Class
Active energy 1 or 2 (B or A)
Reactive energy 2 or 3
Nominal and maximum current 5 (100) A
129,1
120

Nominal voltage, Un 110-230 V (single-phase)


3x(110-230)/(190-400) V (three-phase)
206,2
197

216

Voltage range 0.8 Un – 1.15 Un


Frequency 50/60 Hz
Optical port IEC 62056-21 (physical layer)
301,8

IEC 62056-46 (DLMS) communication protocol


Self-consumption IEC 62053-21/22/23/61
64

Operational temperature range -40 °C - +70 °C


Storage temperature range -40 °C - +80 °C
Insulation AC strength 4 kV, 50 Hz, 1 min 104,5
131,2
Insulation impulse strength 6 kV; 1.2/50 µs
67,2

IP protection level IP54, in accordance with IEC 60529


Dimensions 302 x 178 x 81 mm (three-phase)
216 x 131 x 81 mm (single-phase)
Weight Approx. 1.80 kg (three-phase) 150
Approx. 0.83 kg (single-phase) 178,2

Meter&Control d.o.o. | Science Technology Park Belgrade


Veljka Dugoševića 54 | 11050 Belgrade | Serbia
office@meterandcontrol.com | www.meterandcontrol.com Solutions for smart energy management
We strive to make the content of promotional materials as timely and accurate as possible. Meter&Control makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly
disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title,
merchantability, and fitness for a particular purpose, is given with respect to the content of these promotional materials. © Copyright 2022 Meter&Control. All rights reserved. 09/2022

You might also like