MEASUREMENT SYSTEMS

NUFLO™

Scanner 2200 EFM


®

The NuFlo Scanner 2200 EFM is Cameron’s one-box solution


for gas, liquid and steam measurement. This Scanner pairs the
same high-efficiency electronics used in the Scanner 2000 with
a weatherproof enclosure, providing room for a battery, charge
controller, and radio or modem, all in a single box.
Three Power Options
The Scanner 2200 can be powered with the integral lithium
battery, with customer-supplied DC power, or with a customer-
supplied solar panel.

The lithium battery supplied with the device ensures customers


of worry-free performance, providing months of autonomous
power even if the primary power source fails. Where there is a
need to power communications peripherals, external power is
recommended.
You really can have it all –
Solar-powered units and DC-powered units are shipped with
data collection for up to
an integral solar charge controller/DC power supply and a 12V, three flow runs, worry-free
33-amp-hour battery for supplying power to the instrument. lithium battery power, and
communications—in a single
Broad Range of Applications ready-to-install box.
High-speed communication via industry standard Modbus® and
Enron Modbus® protocols makes the integration of input and measurement and oil measurement. Two pulse/contact
output devices easy and effective. inputs, two analog inputs, two digital outputs, and an
analog output are also provided.
The Scanner 2200 can calculate flow from the differential
pressure output of an orifice or cone meter using the integral PID Control
multi-variable transmitter, or a remote transmitter. Additionally,
it can calculate flow from the linear pulse output of a turbine,
positive displacement or vortex flowmeter.

Common applications include:


• AGA-3 compliant gas measurements using the integral
MVT and a process temperature input
• AGA-7 compliant gas measurements using a pulse output
gas meter (turbine, rotary or vortex)
• Compensated liquid measurements using an orifice, cone,
or averaging pitot meter
• Temperature-compensated liquid measurements using a
liquid turbine meter and an in-line RTD

The instrument’s integral MVT and two turbine inputs enables


simultaneous measurements within three separate flow runs, When purchased with the PID control option, the Scanner
which could represent a gas measurement, water 2200 can be used to control process variables such as static
pressure, differential pressure, 12V lead acid battery
temperature, and flow rate. Serial-to-
Ethernet
A 4-to-20 mA output is converter
configured to regulate a control (option)

valve, and control parameters DC-to-DC


converter
are tuned with the easy-to-use (option)
tools that are built into the
standard Scanner 2200 software
platform, ModWorX Pro. Users
can configure the Scanner 2200
to provide PID control for a
single parameter, or opt for
PID control of flow rate with
a secondary pressure control.
Solar charge
See our Feature Profile on PID controller

Control for more information.


Easy Configuration Lithium battery pack

Every Scanner 2200 EFM is


shipped with ModWorX Pro The 14-in. x 12-in. x 8-in. weatherproof Scanner 2200 enclosure houses the electronic circuitry, an
integral solar charge controller or DC power supply, a 12V, 33-amp-hour battery, a lithium battery
software for configuring
pack, and a radio or modem. Communications options include a DC-to-DC converter for powering
hardware and flow calculations, an analog input or analog output loop with solar power, and a serial to Ethernet converter for
calibrating inputs, and collecting connecting the EFM to an Ethernet network.
and viewing flow history.
Measurements can be logged as
frequently as every 5 seconds, Enclosure • Fluid properties
or once every 12 hours. The • Dimensions: 14 in. x 12 in. x 8 in. • AGA-8-92 (Detail and Gross)
instrument can log 768 daily • IF-97 (Steam)
• Supports mounting and signal
records (more than 2 years), connections for radios and modems • Generic Liquid (Water or Emulsions)
6,392 interval records (more than • API-2540 Liquid (Crude Oil, Gasoline,
8 months at 1-hour intervals), Display Jet Fuel, Fuel Oils,
and 1152 event/alarm records. • Adjustable contrast and update period Lube Oil)
Quick and Easy Downloads • Two-line LCD readout • Wet correction (Steam)
• 8-digit value display (top line) • James (Orifice)
Data downloads to a laptop
• 6-digit parameter scrolling display • Chisholm (Orifice)
computer have never been
(bottom line) • Steven (Cone)
easier. Just plug a USB cable into
your computer and connect the • Easy-to-read 0.5-in. characters
Certification
other end to the external USB • View up to 12 user-defined parameters
• Electrical Classification
port in the side of the enclosure. • Configurable units of measurement
• Approved by CSA for US and
Configurable radio power • Adjustable contrast, update period, and Canada—Class I, Div. 2,
controls can also be enabled scroll duration Groups A, B, C, D, T4
to power the radio only during • Rated for Internal Pollution Degree 2
desired download periods.
Calculations
• CSA/UL Type 4 or 4X Enclosure Rating
• Flow rate (Natural Gas, Steam
(Ingress Protection);
and Liquid)
Type 4X requires MVT with stainless
• AGA-3
steel bolts
• AGA-7
• ANSI 12.27.01 Single Seal
• Compensated Liquid Turbine
(0 to 3000 psi) at process temperatures
• ISO 5167
from -40 to 121°C
• Cone
• Pressure Classification
• Averaging Pitot Tube (Annubar®)
• ASME pressure vessel code compliant,
0 to 3000 psi (CRN 0F10472.5C)

2
MEASUREMENT SYSTEMS

Communications Process Temperature Input Memory


• RTU Modbus® communications • 100-ohm platinum RTD with 2-wire, • Non-volatile memory for
• Communications Port 1 – RS-485 3-wire, or 4-wire interface configuration and log data
• Can be used simultaneously • Sensing Range: -40°F to 800°F • 512 KB
with Port 2 (-40°C to 427°C) • Data stored for 10 years
• Selectable baud rate: 9600 to • Accuracy: 0.2°C (0.36°F) over without power
38,400 sensing range at calibrated
• Communications Port 2 – USB, MVT
temperature
RS-232, or RS-485 • Provides linearized digital data
• Temperature effect (Fahrenheit):
• External USB port for quick • Static pressure
0.54°F over operating range of
connections • Differential pressure
-40°F to 158°F
• Three connection options (only one • Available with bottom ports
• Temperature effect (Celsius):
can transmit/receive at a time) (gas measurement) or side ports
0.3°C over operating range of
• Can be used simultaneously (liquid or steam measurement)
-40°C to 70°C
with Port 1 • NACE-compliant units also available
• Resolution: 24 bits
• Selectable baud rate: 9600 to • User-adjustable sample time and
38,400 • User-adjustable sample time
damping
• Configurable radio control (can be and damping
used to manage radio power, based MVT Accuracy
Outputs
on state of charge or time of day) • Stability: Long-term drift is less
Digital Outputs 1 and 2
• Full download in approximately 6 min. than ±0.05% of URL per year over
• Configurable as pulse output or a 5-year period
• Enron Modbus® compliant downloads
alarm output
• User-defineable block reads allow the • Differential pressure: ±0.05% of span
grouping of up to 25 floating point • Solid-state relay • Effect on differential pressure for
values for faster data transfer using a • Output rating: 60 mA max @ a 100 psi change in pressure
SCADA system 30 VDC • Zero shift: ±0.05% of URL
• Pulse output • Span shift: ±0.01% of reading
Inputs • Configurable pulse duration
• Static pressure: ±0.05% of span
Turbine Meter Inputs 1 and 2 • Maximum frequency: 50 Hz
• Temperature performance:
• Configurable sensitivity adjustment • Configurable pulse representation
0.25% of full scale over full operating
(20 mV to 200 mV, peak to peak) (1 pulse = 1 MCF)
temperature range
• Frequency range: 0 to 3500 Hz • Based on any accumulator
(flow run or turbine inputs) • Resolution: 24 bits
• Input amplitude: 20 mV to 3000 mV,
peak to peak • Alarm output MVT Pressure Ranges
• Low/high
Pulse Inputs 1 and 2 Static Maximum
• Out-of-range Differential
• Accepts a signal from a turbine meter Pressure
Pressure
Overrange
• Status/diagnostic /SWP Pressure
or positive displacement meter (PSIA) (In. H2O) (PSIA)
• Latched/unlatched
• Optically isolated
• Normally open/normally closed 100 30 150
• Input: 3 to 30 VDC or contact closure
Analog Output 300 200 450
• Can be used as a status input when 840 450
Turbine Meter Input 2 is in use • 4-20 mA
500 200 750
• Accuracy: 0.1% of full scale @ 25°C
Analog Inputs 1 and 2 1500 200 2250
(77°F), 50 PPM/°C (27.8 PPM/°F)
• 3-wire sensor interface 300 2250
temperature drift 400 2250
• Sensor power same as external power
• Represents any measured variable 840 2250
supply for main board (6 to 30 VDC)
(e.g., differential pressure) or 3000 200 4500
• Accuracy: 0.1% of full scale
calculated parameter (e.g., flow rate) 300 4500
• Temperature effect: 0.25% of full 400 4500
• Regulates control valve in PID
scale over operating temperature 840 4500
control applications
range of -40° to 158°F (-40° to 70°C) 5300 200 7420
• Optically isolated
• Resolution: 20 bits 300 7420
• User-adjustable sample time • Resolution: 16 bits 400 7420
840 7420
and damping

3
MEASUREMENT SYSTEMS

Operating Temperatures • Archive data downloads • Reporting


• Standard: -15°C to 50°C (5°F to 122°F) • Configurable downloads of • Daily logs (table or trend graph)
• Extended range with optional battery: “all” or “new” records • Interval logs (table or trend graph)
-40°C to 60°C (-40°F to 140°F) • Download types: daily, interval, and • Event/alarm logs
event/alarm records • Configuration settings
• LCD contrast is reduced below
• Downloads are automatically saved • Calibration settings
-30°C (-22°F)
in uneditable binary (SDF) files • Snapshot of current status data
Audit Trail • Exports to .xls, .csv, .rtf, .html, and calculated parameters
• API 21.1 compliant Flow-Cal® and PGAS® formats
• Daily records: 768 (>2 years)
• Interval records: 6392
(>8 months of 1-hour intervals)
Dedicated button for quick and easy downloads
• Adjustable from 5 sec. to 12 hours
• Event/alarm records: 1152
Four menus
• Records up to 16 user-defined simplify
parameters navigation

Interface Software
• Provided at no charge
• Easy to use
• Internal links to hardware and
software manuals
The ModWorX Pro
• Real-time data polling software interface
• Complete configuration offers easy access
to the most
• Configuration upload tool for
commonly used
configuring multiple units functions from one
• Multi-level security main display screen.

• Field calibration Documentation for quick reference

• 1 to 12 calibration points
for each parameter
• Three methods: multi-point,
set zero point, and verify
Calibrate Inputs: Maintain Flow Run: Maintain Turbine: Configure:
• Inputs are automatically locked Differential Pressure Change Orifice Plate Change Turbine SYSTEM PARAMETERS
Static Pressure Change Cone Flowmeter Device ID
during calibration Process Temperature Change Gas Composition Change K-Factors Date and Time
Analog Input 1 Change Liquid Properties Communications
• Maintenance Analog Input 2 Change Steam Properties Security
• Change plate Calibrate, Verify and
Change Flow Coefficients Display
Change Avg. Pitot Tube Archive
• Change cone Set Zero Offset selectiions
available for each parameter.
Alarm
Modbus Registers
(linearization: 1 to 12 points) FLOW RUN SETUP
• Change averaging pitot tube Task-based menus help operators TURBINE SETUP
perform their jobs quickly and easily. INPUTS
• Change gas composition Differential Pressure
Static Pressure
• Change steam properties Process Temperature
Analog Inputs 1 & 2
• Change liquid parameters OUTPUTS
• Change flow coefficients Digital
Analog
• Change K-factor
(linearization: 1 to 12 points)
• Change turbine flowmeter

MEASUREMENT SYSTEMS

HOUSTON 2 81 . 582. 9500 NORTH 1. 800. 65 4 . 3 7 6 0 ASIA +603.5569.0501 EUROPE, + 4 4 . 1 2 4 3 .8 2 6 7 4 1


HEAD OFFICE AMERICA PACIFIC MIDDLE EAST
ms-us @ c-a-m.com ms-kl@c-a-m.com & AFRICA ms-uk@c-a-m.com

U S A • C A N A D A • U K • C H I N A • U A E • A L G E R I A • M A L AY S I A • I N D I A • R U S S I A w w w. c - a - m . c o m / f l o

EFM-2200 NF00153 1112 © Copyright 2011 Cameron International Corp. All Rights Reserved.