MEASUREMENT SYSTEMS

NUFLO™

Scanner 2000
®

microEFM
The NuFlo Scanner 2000 microEFM Explosion-proof Mounting options include:
packs the gas, steam, and liquid Package • Direct mount to an orifice
measurement capabilities traditionally meter or cone meter using a
The explosion-proof package features:
found in large flow computers into a flange-by-flange manifold
compact, low-power instrument. • an integral MVT
• Remote mount to an orifice
• Lithium battery (standard) for
meter or cone meter using
Simplicity and ease of use are integral autonomous power
a pole mount kit
to this instrument’s design. Basic • External power supply
• Direct mount to a Barton 7000
parameters can be configured quickly (6-30 VDC) optional with
Series turbine meter
from a keypad inside the enclosure. internal battery backup
All other parameters are easily The explosion-proof package
• Keypad for basic configuration
configured using a PC or laptop has received the following approvals:
inside the enclosure
and the ModWorX™ Pro software • CE approved
provided free with every Options include: • ATEX certified, II 2 GD Ex d IIC T6
Scanner 2000 purchase. • Explosion-proof control switch IP68 (-40°C to 70°C)
• Push-button control of display • CSA certified for US and Canada
The Scanner 2000 is an economical parameters and daily log views Class I, Div. 1, Groups B, C, D,
chart recorder replacement, a flow • Eliminates need to open enclosure Type 4 enclosure, ANSI 12.27.01
computer, and a stand-alone totalizer. • Explosion-proof communications adapter single seal (0 to 3000 psi)
Its measurement capabilities include • Quick connect to laptop • Measurement Canada certified for
compensated gas, steam, and liquid • Installs in conduit opening for custody transfer, Approval No. AG-0557C
measurements based on the • USB or RS-485 connection • GOST-R/GOST-K certified
differential pressure input supplied • Eliminates need to open enclosure • ASME pressure vessel code compliant
by an orifice plate, cone meter, • Pole mount kit (0 to 3000 psi); CRN 0F10472.5C
or averaging pitot tube, or the
frequency input from a turbine meter.
A turbine input can be used for Weatherproof Package
liquid measurement or compensated The weatherproof package features: Options include:
gas measurement in accordance
• an 8-in. square • Solar kit (solar charger and two
with AGA-7. Modbus® protocol and
enclosure rechargeable 6V batteries; solar panel
two RS-485 communication ports sold separately)
• an integral MVT
allow remote communication to
• USB connection for • Radio kit
host systems. The instrument’s
downloading data • Pole mount kit
ability to measure gas and water
to a laptop
simultaneously is also a clear Mounting options include:
• Lithium battery (standard)
advantage for coalbed methane • Direct mount to an orifice meter or
for autonomous power
operators. cone meter using a flange-by-flange
• External power supply (6-30 VDC)
manifold
The Scanner 2000 microEFM is optional with internal battery backup
• Remote mount to an orifice meter or
available in two packages: • Solar power optional with internal
cone meter using a pole mount kit
an explosion-proof package certified battery backup
* The weatherproof package has not been tested
for use in hazardous areas, and a • Keypad for basic configuration inside or certified for use in hazardous areas.
weatherproof package. the enclosure
Display Inputs
The Scanner 2000 offers • Two-line LCD with easy-to-read Turbine Meter Inputs 1 and 2
alphanumeric characters (Expansion Board Required for
• Low-power operation for Turbine Input 2)
remote installations • 8-digit display of values (top line)
• 6-digit display identifies each • Configurable sensitivity adjustment
• Fully autonomous operation (20 mV to 200 mV, peak to peak)
scrolling parameter and its
via lithium battery pack
engineering unit (bottom line) • Frequency range: 0 to 3500 Hz
(1-year typical)
• View up to 12 user-defined • Input amplitude: 20 mV to 3000 mV,
• Extremely accurate, stable
parameters peak to peak
and repeatable input readings
• View daily log data (99 days) • Turbine Input 2 cannot be used
using an integral MVT
• User-selectable units of measurement simultaneously with a pulse input
• API 21.1 compliant
• Archives up to 16 user-selectable • Character height - 0.3 in. Pulse Input
• Adjustable contrast and update period (Expansion Board Required)
parameters
• Accepts a signal from a turbine
• Generous log capacity:
Calculations meter or PD meter
768 daily records, 2304 interval
• Flow rate (Natural Gas, Steam • Optically isolated
records (6392 with expansion
and Liquid) • Input: 3 to 30 VDC or contact
board option), 1152 event/alarm
• AGA-3 closure
records
• AGA-7
• Fast data transfer: full archive • Cannot be used simultaneously
• Compensated Liquid Turbine
download in approximately with Turbine Input 2
• ISO 5167
3 minutes with main board only Analog Inputs 1 and 2
• Cone
(6 minutes with expansion (Expansion Board Required)
• Averaging Pitot Tube (Annubar®)
board option) • 3-wire sensor interface
• Fluid properties
• Two RS-485 communication ports • Sensor power same as external
• AGA-8-92 (Detail and Gross)
• USB communications option • IF-97 (Steam) power supply for main board
• Modbus® protocol • Generic Liquid (Water or Emulsions) (6 to 30 VDC)
• Configurable inputs/outputs • API-2540 Liquid (Crude Oil, • Accuracy: 0.1% of full scale
• A process temperature input, Gasoline, Jet Fuel, Fuel Oils, • Temperature effect: 0.25% of full
a turbine meter input, a digital Lube Oil) scale over operating temperature
output (volumetric pulse output • Wet correction (Steam) range of -40°F to 158°F
or alarm) • James (Orifice) (-40°C to 70°C)
• With expansion board, a second • Chisholm (Orifice) • Resolution: 20 bits
turbine meter input, a pulse • Steven (Cone) • User-adjustable sample time
input, two analog inputs, and and damping
an analog output Communications/
Archive Retrieval Process Temperature Input
• Easy-to-read LCD • 100-ohm platinum RTD with 2-wire,
• Modbus (RTU) with two on-board
• Quick and easy configuration and 3-wire, or 4-wire interface
RS-485 communications slave ports
calibration (1 to 12 calibration • Sensing Range: -40°F to 800°F
• COM 1 and COM 2 baud rates:
points available for all inputs) (-40°C to 427°C)
300 to 38.4K
• Non-volatile memory • Accuracy: 0.2°C (0.36°F) over
• USB communications with optional
• Performs industry standard sensing range at calibrated
adapter
calculations: AGA-3, AGA-7, temperature
• Enron Modbus compliant downloads
ISO 5167, ASME MFC-12M • Temperature effect (Fahrenheit):
(Averaging Pitot Tube), AGA-8 • User-definable block reads allows
the grouping of up to 25 floating 0.54°F over operating range of
(Detail & Gross), Cone, IF-97 -40°F to 158°F
(Steam), and API-2540 (Liquid) point values for faster data transfer
when used with a SCADA system • Temperature effect (Celsius):
• Full archive download in 0.3°C over operating range of
approximately 3 minutes with -40°C to 70°C
main board only (6 minutes with • Resolution: 24 bits
expansion board option) • User-adjustable sample time
and damping

2
MEASUREMENT SYSTEMS

Outputs Keypad Configuration


Digital Output With the three-button keypad, changes to basic parameters can be made quickly and
• Configurable as pulse output or easily simply by removing the enclosure lid (computer software is not required). The
alarm output slave address, baud rate, date and time, and orifice plate size can all be configured
• Solid-state relay from the keypad.
• Output rating: 60 mA max @ 30 VDC
• Pulse output
• Configurable pulse duration
• Maximum frequency: 50 Hz
• Configurable pulse representation
(1 pulse = 1 MCF)
• Based on any accumulator
(flow run or turbine inputs)
• Alarm output
• Low/high
• Out-of-range CONFIGURATION: CONFIGURATION:
• Status/diagnostic Move between menus Save configuration
TEST ACCESS
• Latched/unlatched and menu selections settings
• Normally open/normally closed OPERATION: OPERATION:
View next parameter Save totals
Analog Output
(Expansion Board Required)
CONFIGURATION:
• 4-20 mA
Change digits and
• Accuracy: 0.1% of full scale @ 25°C PRESS + other menu selections PRESS +
(77°F), 50 PPM/°C (27.8 PPM/°F)
OPERATION:
temperature drift simultaneously to view View daily logs simultaneously to access
• Represents any measured variable time/date, temperature, Configuration menu
(e.g., differential pressure) or and battery voltage
calculated parameter (e.g., flow rate)
• Optically isolated
• Resolution: 16 bits MVT Accuracy MVT Pressure Ranges
Memory • Stability: Long-term drift is less Static Maximum
than ±0.05% of URL per year over Pressure Differential Overrange
• Non-volatile memory for /SWP Pressure Pressure
a 5-year period
configuration and log data (PSIA) (In. H2O) (PSIA)
• 256 KB (512 KB with expansion • Differential pressure: ±0.05% 100 30 150
board option) of span
300* 200* 450
• Data stored for 10 years • Effect on differential pressure for 840 450
without power a 1000-psi change in pressure
500* 200* 750
• Zero shift: ±0.05% of URL
MVT 1500* 200* 2250
• Span shift: ±0.01% of reading 300 2250
• Provides linearized digital data • Static pressure: ±0.05% of span 400* 2250
• Static pressure • Temperature performance: 840 2250
• Differential pressure 0.25% of full scale over full 3000** 200 4500
• Available with bottom ports (gas operating temperature range 300 4500
measurement) or side ports (liquid or 400 4500
• Resolution: 24 bits 840 4500
steam measurement)
5300** 200 7420
• NACE-compliant units also available
300 7420
• User-adjustable sample time and 400 7420
damping 840 7420
* This MVT range is available in an explosion-proof
or weatherproof package. Unmarked ranges are
available in an explosion-proof package only.
** Not evaluated for Measurement Canada approval

3
MEASUREMENT SYSTEMS

Environmental • Archive data downloads • Reporting


Operating Temperature Range • Configurable downloads of • Daily logs (table or trend graph)
“all” or “new” records • Interval logs (table or trend graph)
• -40°F to +158°F (-40°C to +70°C)
• Download types: daily, interval, • Event/alarm logs
• LCD contrast is reduced below
and event/alarm records • Configuration settings
-22°F (-30°C)
• Downloads are automatically • Calibration settings
saved in uneditable binary • Snapshot of current status data
Audit Trail
(SDF) files and calculated parameters
• Daily records: 768 (>2 years)
• Exports to .xls, .csv, .rtf, .html, • Online documentation
• Interval records: 2304 (>3 months and Flow-Cal® formats • Quick Start guides
of 1-hour intervals); 6392
• Hardware manual
(>8 months of 1-hour intervals)
• Software manual
with expansion board option
• Adjustable from 5 seconds to
12 hours
Dedicated button for quick and easy downloads
• Event/alarm records: 1152
• Records up to 16 user-defined
parameters Four menus
simplify
navigation
Interface Software
• Provided at no charge
• Easy to use
• Real-time data polling
• Complete configuration
• Configuration upload tool for
The ModWorX Pro
configuring multiple units software interface
• Multi-level security offers easy access
to the most
• Field calibration
commonly used
• 1 to 12 calibration points functions from one
for each parameter main display screen.
• Three methods: multi-point, Documentation for quick reference
set zero point, and verify
• Inputs are automatically locked
during calibration
• Maintenance
Calibrate Inputs: Maintain Flow Run: Maintain Turbine: Configure:
• Change plate Differential Pressure Change Orifice Plate Change Turbine SYSTEM PARAMETERS
Static Pressure Change Cone Flowmeter Device ID
• Change cone Process Temperature Change Gas Composition Change K-Factors Date and Time
(linearization: 1 to 12 points) Change Steam Properties Communications
Change Flow Coefficients Security
• Change averaging pitot tube Calibrate, Verify and Change Avg. Pitot Tube Display
Set Zero Offset selectiions Archive
• Change gas composition available for each parameter.
Alarm
Modbus Registers
• Change steam properties FLOW RUN SETUP
• Change liquid parameters Task-based menus help operators TURBINE SETUP
perform their jobs quickly and easily. INPUTS
• Change flow coefficients Differential Pressure
Static Pressure
• Change K-factor Process Temperature
(linearization: 1 to 12 points) OUTPUTS
Digital
• Change turbine flowmeter

MEASUREMENT SYSTEMS