Instruction Sheet P/N 1093771A

Flow Control Valve Bypass Kit - P/N 1093624 Issued 1/09

This kit contains a flow control bypass valve assembly for use on an WARNING: Risk of personal injury or equipment damage! Refer to Required Tools:
AltaBluet TT adhesive melter. Before the bypass valve assembly can be the safety information provided in the melter manual before
installed, the runup pressure control valve (P/N 1024689, which is servicing the melter. Failure to comply with the safety information 8-mm wrench
contained in kit P/N 1034042) must be installed. provided can result in personal injury, including death.

1. Switch the melter off. 3. Using the M5 washers and nuts 4. Connect tubing from the flow control
provided, mount the flow control bypass bypass valve assembly to the runup
valve assembly to the rear left leg of the pressure control valve.
2. Disconnect power to the melter melter.
at the local power disconnect switch.
NOTE: The runup pressure control
valve (P/N 1024689) should already be
installed on the melter.

Flow control bypass valve


assembly 5. Install an air line adapter fitting
(customer-supplied) in the air pressure
regulator input port. Connect a supply of
clean, dry, compressed air to the adapter
fitting.

M5 Nylok hex nut (2)


7. Connect the solenoid valve on the flow
control bypass valve assembly to a control
signal (customer-supplied).

8. Adjust the flow control bypass valve


air pressure regulator as needed to achieve
M5 flat washer (2) the correct bypass pressure when the
applicator is turned off.

1/8 NPT
1/4-in. tube