Kit Installation Instructions

Product(s):
Xerox Versant 80, 2100
Kit Part #: 948K03112
948K16840
Title
Date: Feb, 2017 Page:
Versant Developer Assembly Kit Instructions 1 of 1

Instruction #: Tag/MOD# 19 Classification


607E18890
code: O
WARNING
Purpose
Do not perform repair activities with the power
This kit includes one developer assembly (developer switched on or electrical power supplied to the
housing) with a new style top cover. The developer machine. Some machine components contain
housing cover is vented to relieve pressure in the dangerous electrical voltages that can result in
housing that results in excess developer waste. electrical shock and possible serious injury.
In addition, a NVM script must be used to write NVM
changes on Versant 80 and 2100 presses without Tag
Procedure
19. The NVM script corrects ATC calibration for
For Versant Versant 80, 2100 with Tag 19:
lower pressure conditions.
1. Replace the developer assembly using new
Kit Contents developer material per REP 9.12 and REP 9.13.
Item Description Qty 2. Input the new ATC numbers using dc950.
1 Developer Assy 1 3. Reset the HFSI counter for the new housing(s)
2 Install Instructions 1
For Versant 80, 2100 without Tag 19:
Note: Vented cover will be included with p/n
948K03112 and later developer assemblies.
1. Remove the drum modules and store in a
Total Install time = 15 minutes. lightproof bag.
2. Perform GP 18 Xerographic Trim Procedure
3. If machine does not have Tag 19 write the
required NVMs.
Follow GP 16 NVM Access and write the updated
NVM script.
• Versant 2100 NVM script:
Write_NVM_Versant2100_with-
Vent Tag19(VentCvr).csv
The Versant 2100 NVM script can be
found in GSN Library 13985 or 14631.
• Versant 80 NVM script:
Write_NVM_Versant80_with-
Tag19(VentCvr).csv
The Versant 80 NVM script can be found
in Library 14471 or 14516.
4. Install the new developer assembly/assemblies
and new developer material.
Reference REP 9.12 Developer Housing (Y, M, C,
K) and REP 9.13 Developer Material Replacement
(Y, M, C, K).
5. Input the new ATC numbers using ADJ 9.2 ATC
Sensor Setup (dC 950).
6. Reset the HFSI counter for the new housing(s)
and developer material.
7. Mark off Tag 19 on the IOT Tag matrix.