DATE SAMPLED 28-Sep-16 22-Jan-16 13-Jun-15 03-Jun-14 05-Mar-14 08-Jun-12

DATE RECEIVED 24-Oct-16 10-Mar-16 13-Jul-15 02-Apr-15 08-Apr-14 10-Oct-12


DATE REPORTED 01-Nov-16 11-Mar-16 20-Jul-15 03-Apr-15 15-Apr-14 12-Oct-12

LAB NO. 44021495813 44021363347 44021222847 44021163594 44020913690 44020513749


SIF NO. 93580140 93095638 92745427 92158948 92025796 91145011
TIME ON UNIT
UIN 02CCB83 TIME ON OIL
OIL BRAND Castrol Castrol Castrol Castrol Castrol Shell
OIL TYPE Hyspin AWH-M Hy Hyspin AWH-M Hy Hyspin AWH-M Hy Hyspin AWH-M Hy Hyspin AWH-M Hy Tellus S2 V
Hydraulic System OIL GRADE ISO 46 ISO 46 ISO 46 ISO 46 ISO 46 ISO 46
OIL ADDED
Unit No. 331_C02_DS6 FILTER Not Applicable
OIL CHANGED Not Changed Not Changed Not Changed Not Changed Not Changed Not Changed
Unit: WO NUMBER
Make Metals (ppm)
Model Iron (Fe) <1 2 <1 <1 <1 <1
Serial No. DS6331B Chromium (Cr) <1 <1 <1 <1 <1 <1
Site DS6 Routine Lead (Pb) <1 <1 <1 3 <1 <1
Copper (Cu) 2 1 <1 <1 <1 4
Compartment: Tin (Sn) <1 <1 <1 <1 1 <1
Name Mud Centrifuge No.2 Hyd Aluminium (Al) <1 <1 1 1 <1 <1
Nickel (Ni) <1 <1 <1 <1 <1 <1
Make NOV Silver (Ag) <1 <1 <1 <1 <1 <1
Model Brandt HS 3400 VSD Titanium (Ti) <1 <1 <1 <1 <1 <1
Serial No. Semi-Annual Vanadium (V) <1 <1 <1 <1 <1 <1
240.0 Ltrs Lithium <1 <1 3 <1 <1
Capacity:
Contaminants (ppm)
Customer: Silicon (Si) 5 1 <1 2 7 39
ENSCO DS-6 Sodium (Na) <1 <1 3 <1 <1 <1
Potassium (K) <1 <1 <1 <1 <5 <5
5847 San Felipe STE 3300
Houston, TX 77057 Water by Karl Fischer ppm 53 51 72 66 <1 45
USA (E203/D6304)
Additives (ppm)
Magnesium (Mg) <1 9 <1 <1 <1 <1
Laboratory:
Calcium (Ca) 39 25 50 51 52 42
ALS Tribology Barium (Ba) <1 <1 <1 <1 <1 <1
3319 West Earl Drive
Phosphorus (P) 311 296 386 406 368 339
Phoenix, AZ 85017
ph: 602.253.6515 or 800.445.7930 / fax: 602.252.4639 Zinc (Zn) 406 345 541 475 530 457
Molybdenum (Mo) <1 <1 <1 <1 <1 <1
Boron (B) <5 <5 <5 <5 <5 <5
DIAGNOSIS Physical Tests
PROBLEM: Particle count level exceeds Company Viscosity (cSt 40C) 44.4 44.2 37.3 44.5 47.6 37.4
Standard. Wear levels are within Company PQ Index <10 <10 <10 <10 <10
Specifications. Physical properties are acceptable for Physical / Chemical
type of lubricant identified. Acid Number (mgKOH/g) 0.79 0.45 0.90 0.89 0.82 0.71
Oxidation (Abs) E2412/D7414 3 <1 <1 <1 <1 N/A
ACTION: Please see filter image on Page 2, debris
Particle Count
present, filter image shows excessive particulate
contamination present. Advise filter service and/or off- ISO 4406 Rating 21/20/15 15/13/9 17/15/11 19/17/13 21/20/16 21/18/12
line purification. Resample at half of normal sample > 4 Micron (particles/ml) 18910 290 1069 4461 19476 11175
interval to verify sample quality. The rig needs to open a > 6 Micron (particles/ml) 5086 43 276 1135 8255 1554
CM work order. > 14 Micron (particles/ml) 239 4 19 59 467 33
> 23 Micron (particle/ml) 13 1 5 13 120 12
> 50 Micron (particles/ml) 1 <1 <1 1 26 6
ANALYST: Ed.Eckert
LEGEND

Caution Severe Abnormal Caution Normal


Page 1 of 2
UIN 02CCB83
Current Sample Lab Nº 44021363347

Lab Nº 44021222847 Lab Nº 44021163594

Lab Nº 44020913690 Lab Nº 44020513749

TEST METHODS:
Acid Number.........................ASTM D974/D664 Metals by Rotrode AES........ASTM D6595
Base Number........................ASTM D4739 Metals by ICP AES..............ASTM D5185
Base Number (Perchloric).......ASTM D2896 Ox Nox SOx FTIR...............ASTM D7418 / D7414
Fuel Dilution by GC...............ASTM D3524 D7415 / D7624
Fuel Dilution Visc/Setaflash....ASTM D445/D7279/D3828 Particle Count.....................ASTM D7647
Fuel Soot ATR/IR..................In-House Viscosity............................ASTM D445/D7279
Glycol..................................ASTM D2982 Water KF............................ASTM E203 Mod / D6403D
Water Crackle.....................In House

ENSCO DS-6
Since services are based on samples and information supplied by others, and since corrective actions,
Attn: DS6 TC if any, are necessarily taken by others, these services are rendered without any warranty or liability of
5847 San Felipe STE 3300 any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations
Houston, TX 77057 are based on interpretations of the generated test results and historical data. Certain test results
appearing in this report may have been tested at other ALS laboratories within the Tribology divisional
USA network.
0043 v1.3