SIMATIC TANK_LEVEL AUTOMATION\ 07/28/2020 12:38:17 PM

SIMATIC 400(1)\CPU 414-3 PN/DP\...\FB3 - <offline>

FB3 - <offline>
""
Name: Family:
Author: Version: 0.1
Block version: 2
Time stamp Code: 07/28/2020 12:23:59 PM
Interface: 07/28/2020 12:14:36 PM
Lengths (block/logic/data): 00258 00144 00000

Name Data Type Address Initial Value Comment


IN 0.0
active Bool 0.0 FALSE
bottle_present Bool 0.1 FALSE
bottle_filled Bool 0.2 FALSE
t_ll Bool 0.3 FALSE
t_hl Bool 0.4 FALSE
OUT 0.0
conveyor_mtr Bool 2.0 FALSE
feed_valve Bool 2.1 FALSE
fill_valve Bool 2.2 FALSE
IN_OUT 0.0
STAT 0.0
TEMP 0.0

Block: FB3

Network: 1

to fill the tank-feed valve is open wth condi--if T1_ll

#feed_valv
e
#active #t_hl #t_ll #feed_
#active #t_hl #t_ll valve

#feed_valv
e
#feed_
valve

Page 1 of 2
SIMATIC TANK_LEVEL AUTOMATION\ 07/28/2020 12:38:18 PM
SIMATIC 400(1)\CPU 414-3 PN/DP\...\FB3 - <offline>

Network: 2

IF T_HL feed back to start conveyor for bringing empty bottles to filling
station

#feed_valv #fill_valv #bottle_pr #conveyor_


e e esent mtr
#active #feed_ #fill_ #bottle_ #t_hl #conveyor_
#active valve valve present #t_hl mtr

#t_ll
#t_ll

#conveyor_
mtr
#conveyor_
mtr

#bottle_fi
lled
#bottle_ T20
filled S_ODT
S Q

S5T#3S TV BI

R BCD

Network: 3

if bottle-present ...filling system active by fill _valve open

#feed_valv #bottle_pr #fill_valv


e esent e
#active #feed_ #bottle_ T19 #fill_
#active valve present S_ODT valve
S Q

S5T#3S TV BI

#bottle_fi BCD
lled
#bottle_
filled R

Network: 4

total filled botle count

#bottle_fi
lled
#active #bottle_ C10
#active filled S_CU
CU Q

S CV MW55

PV CV_BCD