You are on page 1of 2

Critical

RETRACTABLE Facility
GROUNDING
ASSEMBLY (RGA® 750)

Continuous Lightning Protection


Bonding for Floating Roof Tanks
Feature Highlights:
Effective Factory Pre-Tensioned Standards Conformant
Low-impedance bond prevents Reliable Retractibility: API 545
fires triggered by lightning No on-site tensioning required NFPA 780
currents
Durable and Low Maintenance Certifications
Corrosion Resistant • Engineered for years of ATEX Approved
Retractable conductor cable is durability and reliable Patented (US Patent #7,078,621)
made of marine-grade aluminium performance in corrosive
• Highly resistant to hydrogen environments
sulfide (H2S) • Requires virtually no upkeep as
*Tinned copper option available upon request compared to shunts
Benefits of RGA®
Provides low impedance pathways to Reduces the risk of tank fires by
safely discharge lightning currents subduing sustained arcs during lightning
events and other electrical phenomena

Conventional Bypass Conductor vs RGA


The Retractable Grounding Assembly
(RGA®)provides direct electrical bonding connection
between the floating roof and the tank shell,
substantially reducing the risks of lightning-related
tank fires.
Conventional Bypass Conductor The RGA outperforms other traditional bonding
When the roof is high, the conductor is randomly methods as the retractable cable is always at its
coiled upon itself resulting in high impedance. shortest possible length - resulting in a low
resistance and low impedance connection between
the tank shell and roof.

Retractable bypass conductor


When the roof is high, the conductor is as short as
possible, providing the lowest possible impedance
between the roof and shell. When a typical floating
roof tank is 80% full, the impedance of the RGA is
only 15% that of a conventional bypassconductor.

Did you know?


Floating Roof Tank Fires are Commonly Caused by Lightning
Of the 480 tank fire incidents reported in the media, more than30%
has been attributed to lightning.

Floating Roof Tanks are especially vulnerable to direct andindirect


effects of lightning.
Source: Tank Fires, Review of Fire
Incidents 1951–2003, Brandforsk Project 513-021

Limitations of Shunts 1 2 3

Metal strips called “shunts” have been used by the


industry to reduce the risks of rim fires - electrically
bonding the shell and roof of the tank. Unfortunately, Rust, waxy deposits API Testing proved The floating roof can that
the bonds established by shunts are unreliable and and paint can line the shunts will arc drift slightly off-center under all
create a greater risk of sustained arcs: inner wall of the shell, conditions, and cause the shunts even if the
causing an increase tank wall to lose contact from and shunts are
in resistance new the shell
and clean