You are on page 1of 1

7

Electric Room
IT Room
G G

IT Room
Electric Room
1 2 3 4 5 6 7 8 9 10 11 12 13 12 13
7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m

7
A A

7,200m

7,200m
B B

7,200m

7,200m
C C
7,200m

7,200m
OFFICES
D D

R&D
Meeting
7,200m

7,200m
8 P.
Meeting
8 P.
E E
7,200m

7,200m
IT Room
F F

Meeting

Electric Room
8 P.

ADMINISTRATION
7,200m

7,200m
GFA UA 1 UA 2 UA 3 UA 4 UA 5 UA 6 UA 7 SA CA
Gross Floor Area Social Activities Office Area Kitchen Storage Training
GFA UA1 UA2 UA3 UA4 UA5 Medical Facilities
UA6 UA1-6 Washrooms
UA7 Technical Areas
SA Corridors
CA KF

IT Room
Workshops Receptions Conference Car Parks Stairs

Roof GFA
1.045,82 UA1
0,00 UA2
0,00 UA3
0,00 UA4
0,00 UA5
0,00 UA6
0,00 UA1-6
0,00 UA7
0,00 SA
694,26 CA
245,64 KF
105,92
Level 3 5.823,59 0,00 5.005,05 0,00 6,13 0,00 0,00 5.011,18 104,13 63,70 570,01 74,57
G G Roof
Level 2
Level 3
1.045,82
6.282,49
5.823,59
0,00
0,00
0,00
0,00
5.272,44
5.005,05
0,00
0,00
0,00
0,00
6,13
6,13
0,00
0,00
0,00
0,00
0,00
0,00
0,00
5.278,57
5.011,18
0,00
104,13
104,13
694,26
63,70
63,70
245,64
761,71
570,01
105,92
74,38
74,57
Level 1 7.234,06 579,07 0,00 3.671,13 452,84 558,06 0,00 5.261,11 104,13 714,09 1.086,37 68,37
Level 2 6.282,49 0,00 5.272,44 0,00 6,13 0,00 0,00 5.278,57 104,13 63,70 761,71 74,38
Level
Total 1 7.234,06
19.340,15 579,07
1.158,13 0,00
10.277,49 3.671,13
3.671,13 452,84
465,11 558,06
558,06 0,00
0,00 5.261,11
15.550,86 104,13
312,38 714,09
1.535,77 1.086,37
2.663,73 68,37
323,24
7,200m

7,200m
(without technical area) 100,00% 5,99% 53,14% 18,98% 2,40% 2,89% 0,00% 80,41% 1,62% 7,94% 13,77% 1,67%
Total 19.340,15 1.158,13 10.277,49 3.671,13 465,11 558,06 0,00 15.550,86 312,38 1.535,77 2.663,73 323,24
G G (without technical area) 100,00% 5,99% 53,14% 18,98% 2,40% 2,89% 0,00% 80,41% 1,62% 7,94% 13,77% 1,67%

H H
7,200m

7,200m
I I

IT Room
7,200m

7,200m
Chair storage

Electric Room
J J

Meeting
Classroom Meeting Meeting
70 P. 10 P. 10 P.

8 P.
7,200m

7,200m
Amendments Date Name Rev.

L L
7,200m

7,200m
Plan Number Projekt No. Building Consultant Phase Discipline Subdiscipline Drawing Type Building Part Sheet / Detail Scale Approval Revision
Architect
1424 _ H1 _ HEN _ 2 _ A 0 _ G02 00 _ 0001 _ 20 _ V -
Plan Number Projekt No. Building Consultant Phase Discipline Subdiscipline Drawing Type Building Part Sheet / Detail Scale Approval Revision
Structural Engineer
M M _ _ _ _ _ _ _ _

Work Stage Drawing Title


7,200m

7,200m
Concept Design Level 2
Meeting

Projekt No. Building Drawing Type Building Part Sheet/ Detail Scale Format

Meeting
8 P.

1424 01 Floor Plan 02 1 1:200 A0

8 P.
N N
Author Issued Date/ Status of approval Drawn
7,200m

7,200m
HENN GmbH 22.09.2017 - MAN

Client Vinfast Trading and Production Limited Liability Company


-

O O No. 7, Bang Lang 1 Street


Viet Hung Ward Long Bien District
T.
F.
+84 24 3974 9999
+84 24 3974 8888
Hanoi City, Vietnam E. info@vingroup.net
7,200m

7,200m
Project

VINFAST Plant Elevation Datum


N

Hai Phong,Vietnam FF = 0.00m = 6.00m A.S.L.

P P

7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m 7,200m

1 2 3 4 5 6 7 8 9 10 11 12 13 12 13
Generell Planner

HENN GmbH T. +49 (0)89 52357-0


Augustenstr. 54 F. +49 (0)89 52357-123
80333 München E. info@henn.com
7

Structural Engineering -

- -

MEP -

- -

Landscape Design -

- -

Building Physics -

- -

Fire Protection Concept -

- -

You might also like