CUSTOMER: EECOL Industrial Electric Ltda.

INDENT NO: 41360914/200


PO NO:- IMP-21708-CG
CROMPTON GREAVES LTD. PO ITEM NO:2
LT MOTORS DIVISION PO DATE : 20/12/2012
AHMEDNAGAR DATE : 15/1/2013
Motor Type Dimensions-NEMA MG1,IE2 PERFORMANCE AS PER IEC60034-30
QUANTITY 18
DRIVEN EQUIPMENT As Per Customer
DUTY S1
MANUFACTURER CROMPTON GREAVES LTD.
TYPE 3PHASE, AC SQUIRREL CAGE INDUCTION MOTOR
FRAME DESIGNATION EGD182T(Al.Body)
OUTPUT ---- KW 1,5
No. OF POLES 4
VOLTAGE ----- VOLT 220/380/440
FULL LOAD CURRENT----- AMP 6.8/3.9/3.4
FULL LOAD SPEED ---- RPM 1420
ENCLOSURE TEFC Safe Area
TYPE OF PROTECTION IPW55
GAS GROUP NOT APPLICABLE
MOUNTING B3
AMB. TEMP/TEMP RISE ---- °C 40°C/80 Degc (BY RESISTANCE METHOD)
FULL LOAD TORQUE ----- NM 10,10
APPLICABLE CODE IEC60034-1, NEMA MG1 for Dimensions
STARTING TORQUE AS --- %FLT 175
PULL OUT TORQUE --- %FLT 225
%EFF @100% LOAD 82,8
%EFF @75% LOAD 82,5
%EFF @50% LOAD 80
PF @-100% LOAD 0,7
PF @ 75% LOAD 0,6
PF @- 50% LOAD 0,5
ROTATION VIEWED FROM DE Clockwise from DE
BEARING TYPE --- DE/ODE 6206ZZ/6205ZZ
TYPE OF LUBRICATION Greased for life
NET WEIGHT (APPR.) --- KG 31
TYPE OF COUPLING FLEXIBAL DIRECT
CABLE ENTRY 1"NPT - 1NO.
PHASE/CONN/NO OF TERMINAL 3/∆∆-YY-∆/12( Terminated on 6 Stud Block)
FREQUENCY ---- Hz 50.0
INSULATION CLASS F (Temp. rise limited to class ‘B’)
LOCKED ROTOR CURRENT %FLC 600
LR WITHSTD TIME HOT/COLD 8/16.
STATOR THERMAL TIME CONST MIN 30
SPACE HEATERS - WATTS/VOLTS N.A.
ACCESSORIES N.A.
PAINT SHADE RAL 5010 GENTIAN BLUE
TB POSITION FROM DE LHS FROM DE
Load GD SQ. (KG-M²) PLEASE SPECIFY
MOTOR GD SQ. (KG-M²) 0,052
STARTING TIME @100% V SEC Depends on Load GD2 and VFD Setting
TYPE OF STARTING VARIABLE VOLTAGE / FREQUENCY
ALTITUDE UPTO 1000 METER
NOISE LEVEL IEC60034-9
VIBRATION IEC60034-14
Motor suitable for S.F.1.15.
NOTE : 1) ALL PERFORMANCE FIGURES ARE SUBJECT TO IEC-60034 TOLERANCES .
2) IF Motor IS STARTED ON INVERTER , MAX. ALLOWED %THD FOR VOLTAGE = 3%
MINIMUM RISE TIME OF PULSE IS TO BE 0.1μsec, AND TEMPERATURE RISE IS LIMITED TO CLASS F LIMITS
3) IF MOTOR STARTED ON INVERTER , VOLTAGE SPIKES ARE ALLOWED MAXIMUM 1600 V
CABLE LENGTH TO BE SELECTED ACCORDINGLY.
4) VARIABLE TORQUE APPLICATION 10-50 Hz.
AND MIN. RISE TIME OF 0.1 MICROSECOND. CABLE LENGTH TO BE SELECTED ACCORDINGLY.
ISSUED BY : Yogesh Wani
LT MOTORS DIVISION , AHMEDNAGAR