LG MULTI V Air Conditioning System


Enjoy a clean &
comfortable life with MULTI V.

Outdoor Unit

10 16
20
MULTI V MINI
MULTI V PLUS II
28 MULTI V SYNC II

2009
34 MULTI V SPACE II

Indoor Unit
Air Conditioning System
38
49
50
Wall Mounted
ARTCOOL
2009
52 Ceiling Cassette
56 Ceiling Concealed Duct
60 Ceiling & Floor
61 Ceiling Suspended Air Conditioning System
62 Floor Standing

Heat Recovery
Ventilator
64 66
67
Features
Installation & Maintenance
68 Line-up
70 Specifications

Network Solution
& Accessory & Accessory Distributed by

72
74

http://www.lgeaircon.com
Remote Controller
76 Central Controller Air Conditioner
84 20 Yeouido-dong, Yeongdeungpo-gu,
Accessory
Yeouido P.O.Box 335 Seoul, 150-721, Korea.
Phone : +82-2-3777 -7998
Fax : +82-2-3777- 5136

http://www.lgeaircon.com

EU-MV091

2009
Life’s Good!
From installation to maintenance and repair,
LG runs 30 global air conditioning academies, providing
training for air conditioning professionals around the world.

B r i e f H i sto r y

Establishment
1947 Establishment of the LG Group
1958 Establishment of LG Electronics Inc.
1962 Establishment of Digital Appliance Company

Growth
1968 Manufactured Korea’s first air conditioners
1985 Introduced Korea’s first Inverter air conditioners
1986 Exported Korea’s first window type air conditioner

Expansion
1995 Establishment of LGE TA in China
1997 Establishment of LG E I L in India
1999 Establishment of LG E AT in Turkey
1999 Establishment of LG E V N in Vietnam
2001 Establishment of LG E A Z in Brazil
2002 Establishment of LG E T H in Thailand
2002 Establishment of LG E I N in Indonesia
2004 Turnover of US$1 .4 Billion dollars
2008 Establishment of LGELF in Levant Countries
2008 Establishment of LGETK in Turkey

Global Air Conditioning Academies

Changwon in Korea Pyeongtaek in Korea Thailand England France Australia Moscow Singapore

Spain Italy Dubai China Saudi Arabia Mexico Panama Indonesia Iran Turkey Vietnam
Multi V Series
Your life comes more quiet, economical and powerful
Outdoor
with LG air conditioning high technology. Unit 16 MULTI V MINI

10 20
28
MULTI
MULTI
V PLUS II
V SYNC II
34 MULTI V SPACE II

Environment

Economic

Engineering Easy Design Indoor


Support & Installation Unit 49 Wall Mounted

38 50
52
ARTCOOL
Ceiling Cassette
56 Ceiling Concealed Duct
60 Ceiling & Floor
61 Ceiling Suspended
62 Floor Standing

eco V
(Heat Recovery
66 Features
Ventilator)
67 Installation & Maintenance
68 Line-up
64 70 Specifications

V-net
& 74 Remote Controller
Accessory 76 Central Controller
84 Accessory
72
Outdoor unit line up
MODEL HP 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64

*1Ø, 220V *3Ø, 380V

MULTI V_Outdoor unit Line up


LG Air Conditioners System
06_07
Indoor unit line up

kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.2 10.6 12.3 14.1 22.4 28.0

Btu / h 5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k

SRAC Wall Mounted

Series
Mirror

4way Cassette

MULTI V_Indoor unit Line up


(570*570)

4way Cassette
(840*840)
Ceiling
Cassette
2way Cassette

1way Cassette

LG Air Conditioners System


Low Static
Ceiling
Concealed Built-in
Duct

08_09
High Static

Ceiling & Floor

Ceiling Suspended

With Case
Floor
Standing
Without Case
Outdoor unit
MULTI V Inverter units composed of serially arranged
refrigerant pipes connected to a single outdoor unit are
an efficient system that offers outstanding energy saving,
simple and easy installation, and connection to different
types of indoor units, making it easy to design and install.

Outdoor Unit_MULTI V series


LG Air Conditioners System
10_11
M U LT I V
outdoor

16 MULTI V MINI

20 MULTI V PLUS II

28 MULTI V SYNC II

34 MULTI V SPACE II
Outdoor unit 2009 New Features
Pursuing the market needs of high energy MULTI V MINI / MULTI V PLUS II
efficiency and environmental friendliness. MULTI V SYNC II / MULTI V SPACE II

World Highest COP! Inverter Combination


Inverter Inverter Inverter
• DC Inverter compressor • Increased performance & high COP
• Inverter combination • Faster response for partial load
• High efficient DC Inverter fan • Optimized combination with space saving
• Wide louver heat exchanger • Competitive price for customers
• Reduced total base model units

Outdoor Unit_MULTI V series


A Company - Simple line-up (16 models > 5 models)
- Easy stock & logistics management
* Based on 10HP model

DC Inverter Constant Speed


Extended Piping Length Compressor Compressor
* 25~105Hz
• MULTI V PLUS II / SYNC II * Using Y branch
1st branch
to farthest Total piping length 1000m
Indoor
Level
difference
40m[90m**]
Longest piping length 150m(200m**)
01
Other Features
100m
15m Longest piping length after 1st branch 40m[90m**]
Level difference between ODU~IDU 100m 01 DC Inverter fan motor
Longest - Max RPM increased from 850 to 920 rpm
piping length
Level difference between IDU~IDU 15m 02 - Power consumption decreased by 30~40%
150m(200m**) Level difference between ODU~ODU 5m

LG Air Conditioners System


02 Wide louver heat exchanger
• Refer to the specifications for more information
- Improved heat exchange rate by 14%
Total piping ** Conditional Application - Anti-corrosion treatment (Gold fin)
length 1000m To make 40~90m of pipe length after first branch,
• MULTI V PLUS II, MULTI V SYNC II refer to the part of “installation of outdoor units” in PDB
03 Black box function
- Save the last 3 minutes operating data
DC Inverter Compressor 03 04 - Precise analysis & fast trouble-shooting

12_13
01 01 Optimized scroll shape 04 Upgraded Main PCB
02 02 Oil injection mechanism - 3-Digit 7 segment
- High reliability in low rpm operation
- High efficiency in partial load operation Wide Louver heat exchanger 3Ø INV controller - Double DIP switch
03
03 Oil discharge reduction
05 - High reliability in high rpm operation Main PCB
04 Corrugate fin
- Enhanced oil circulation
06 04 DC Inverter motor
- High efficiency - Low noise

05 Teflon coated bearing


Wide louver fin
06 High performance oil pump
Outdoor unit 2009 New Features
Pursuing the market needs of high energy MULTI V MINI / MULTI V PLUS II
efficiency and environmental friendliness. MULTI V SYNC II / MULTI V SPACE II

Enhanced comfort for end-user! Night Silent Operation LG MV


Night silent operation will be on for X • Easy start-up, easy trouble shooting
hours starting from the peak temperature Command • Monitoring the normality of all parts
during daytime, and then after Y hours,
such as compressor, fan, valve, etc
it’ll be back to normal operation. Sensor reading

- Mode 1 > X : 8.0 hours, Y : 9.0 hours


- Mode 2 > X : 6.5 hours, Y : 10.5 hours
- Mode 3 > X : 5.0 hours, Y : 12.0 hours

Outdoor Unit_MULTI V series


Each mode can be selected as 3 steps • Operation state • Central Controller • Cycle view
of sound level.
Unit : dBA

MINI PLUS II SYNC II


* Based on MULTI V PLUS II, 10HP model
Step 1 46 47 47
Step 2 43 44 44
Step 3 40 41 41

* Fault detect & diagnosis Automatic Refrigerant LATS MULTI V


• Model selection • Auto check
Manifold Charging • Convenient model selection program
• Refrigerant charging without any
scales or quantity calculation • Highly user-friendly design

LG Air Conditioners System


(Autocad version)
• This function is recommended
during service. • Automatic piping design & check
• Guaranteed temperature range :
Download from sales supporting system
IDU(20~32˚C), ODU(0~43˚C)
Refrigerant > http://www.lgeaircon.com
charging kit • FDD function
• CAD application • Making quotation
(Fault detect & diagnosis)

14_15
Refrigerant

* Fault detect & diagnosis Automatic Refrigerant


Check-Up
Leakage! • It can be checked refrigerant status
during start-up whether it is
Leakage! undercharged or overcharged
Leakage!
• It can be decided appropriate amount
of refrigerant automatically through
Leakage! cycle operation.
• FDD function
(Fault detect & diagnosis)
MULTI V MINI can be easily installed in small offices EFFICIENCY
MULTI V MINI uses the cutting-edge, artificial
and shops. Designed for low-noise operation,
intelligence control to obtain efficient operation
it ensures a pleasant air conditioned environment. and reduced noise.

• Noise level (dBA) Enhanced Comfort


• Night silent operation
• High COP
1Ø, 220V 3Ø, 380V
Cooling Heating Cooling Heating
4HP 3.9 4.0 3.7 3.9
5HP 3.7 4.0 3.6 3.9

Outdoor Unit_MULTI V MINI


6HP 3.6 3.8 3.5 3.8

50 51 52 46 43 40 • Longest Piping Length


4HP 5HP 6HP STEP 1 STEP 2 STEP 3 Total piping length 300m
Day time Night time Longest piping length (Equivalent) 150m(175m)
(Based on 4HP)
Longest piping length after 1st branch 40m
Level difference between ODU~IDU 50m(40m*)
Level difference between IDU~IDU 15m
Level difference between ODU~ODU 5m
*Outdoor unit is lower than indoor unit.

Slim & Compact Size

LG Air Conditioners System


Conventional
5, 6 HP 4, 5, 6 HP Easy & efficient installation of MULTI V
MINI will provide the best solution for small
• Foot print area offices and shops.

46%

730mm
330
mm
Reduction

16_17
950mm
806mm

• Volume

52%
Reduction

WxHxD : 806×1607×730 WxHxD : 950x1380x330

Enjoy a clean &


comfortable life with MULTI V MINI.
‘09 New Feature
MULTI V MINI can be easily installed in small offices • DC Inverter Compressor & Fan motor
and shops. Designed for low-noise operation, • Black Box Function

it ensures a pleasant air conditioned environment. • Night Silent Operation


• Fault Detect & Diagnosis
• Pump Down

Max. 9 Indoor Units


Connectable
Maximum 9 indoor units can be connected
to one single outdoor unit with 130%
indoor unit combination.
1 2 3 4 5
- 9 indoor units for 6HP
- 8 indoor units for 5HP

Outdoor Unit_MULTI V MINI


- 6 indoor units for 4HP
6 7 8 9 units

*Based on 6 HP model

* Specifications *1Ø, 220V *3Ø, 380V


Easy to Service HP 4 5 6 4 5 6
01 Model Independent Unit ARUN40GS2 ARUN50GS2 ARUN60GS2 ARUN40LS2 ARUN50LS2 ARUN60LS2
01 Inner SVC valve Capacity Cooling kW 11.2 14.0 15.5 11.2 14.0 15.5
- 4 Way piping is possible (Front, Rear, Right, Down) Heating kW 12.5 16.0 18.0 12.5 16.0 18.0
- Excellent exterior Power Cooling kW 2.9 3.8 4.3 3.0 3.9 4.4

LG Air Conditioners System


Input Heating kW 3.1 4.0 4.7 3.2 4.1 4.8
COP Cooling 3.86 3.68 3.60 3.73 3.59 3.52
Heating 4.03 4.00 3.83 3.91 3.90 3.75
Power Supply Ø, V, Hz 1, 220 ~ 240, 50 3, 380 ~ 415, 50
Dimensions(WxHxD) mm 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330 950 x 1380 x 330
Weight kg 118 118 118 112 112 112
Color Warm Gray Warm Gray
Noise level Cooling dBA±3 50 51 52 50 51 52
Heating dBA±3 52 53 54 52 53 54
Fan Type BLDC BLDC
1 Way 4 Way

18_19
02 03 Air flow rate [CMM] 110 110 110 110 110 110
Compressor Type DC INVERTER DC INVERTER
Number of compressors 1 1 1 1 1 1
02 Convenient moving handle Heat Exchanger Gold Fin Gold Fin
Refrigerant Type R410A R410A
03 Compact design & Easy service Charge kg 3.7 3.7 3.7 3.7 3.7 3.7
- Remove 3 pieces of screw for SVC Control EEV EEV
Refrigerant Type FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE]
- Front panel removal system
Oil Charge l 1.7 1.7 1.7 1.3 1.3 1.3
Piping Liquid Pipes mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Connections Gas Pipes mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4)
Number of outdoor unit 1 1 1 1 1 1
Number of maximum connectable indoor units 6 8 9 6 8 9
Ratio of the connectable indoor units 50~130% 50~130%
Longest piping length / Level difference 150m/50m 150m/50m
3 pieces of screw
Note :
1. Capacities are based on the following conditions
Easy service Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Level difference of zero Level difference of zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV : Electronic Expansion Valve
MULTI V Inverter system offers one of the world’s
TECHNOLOGY
Your life will be upgraded through the
largest capacity units, essential for high-rise buildings. state-of-the-art technology of MULTI V PLUS II.
We are proud to say the system will ensure the highest
level of customer satisfaction.

Low Noise
• Latest technology and features are
applied to the new outdoor units to
reduce noise level.
*Based on
10HP model

Outdoor Unit_MULTI V PLUS II


Rear Side Front
57dB 52dB 58dB

ODU Noise Comparison


dBA
70

LG Air Conditioners System


65

60
Gernerally lower noise!!
55

HP

20_21
50
5 10 20 30 40
LG Competitor

Alternate-Cycling Function
• To extend compressors’ life span by
operating them alternately
Inverter A <> Inverter B <> Inverter C
ON ON ON ON ON Constant A <> Constant B <> Constant C

• To meet diverse load in operation

Enjoy a clean &


comfortable life with MULTI V. Inverter Constant Inverter Constant Inverter Constant
A A B B C C
MULTI V Inverter system offers one of the world’s
CONVENIENCE
From installation and transportation to maintenance
largest capacity units, essential for high-rise buildings. and service, MULTI V PLUS II adds convenience to
We are proud to say the system will ensure the highest cutting-edge technology.

level of customer satisfaction.

Automatic Back-Up Outdoor unit control box Non-Polarity Transmission


• For emergency, it makes back-up Outdoor
unit
Indoor
unit
Central
controller
Dry
contact
Central
controller
Connection
operation possible before E F A B C D Dry1 Dry2 GND 12V
Easy installation and no errors for
trouble-shooting transmission line connections
ON ON ON Failed ON ON ON
Inverter A, B + Constant B
3 4 3 4 3 4 3 4
> Inverter B + Constant A, B

• Error notice in indoor unit : 4 times

Outdoor Unit_MULTI V PLUS II


Inverter Constant Inverter Constant Inverter Constant Inverter Constant
Indoor unit 1 Indoor unit 2 •••
A A B B A A B B per day (every 6 hour)
* Combination possible model only Outdoor Indoor Indoor
unit unit 1 unit 2
A > 3 or 4 > 3 or 4
•••
B > 3 or 4 > 3 or 4

• Pump down Pump Down & Pump Out


Refrigerant flow • Pump down
Plate Type SC HEX
When indoor units need to replace, • Increased sub-cooling by high-
refrigerant can be collected to the performance heat exchanger
Repair! Repair! Repair!
outdoor unit. Double tube
• Enable to be long piping length
- MULTI V MINI / PLUS II / SYNC II / SPACE II
and level difference
• Pump out • More powerful cooling operation
• Pump out
If left outdoor unit breakdown,

LG Air Conditioners System


Refrigerant flow refrigerant can be sent to another outdoor
Reftigerant flow and indoor unit during service.
- MULTI V PLUS II / SYNC II Plate SC

Failed!

22_23
Cool / Heat Selector
Auto addressing Fan Mode
mode change • Control all units without any central
Indoor unit Indoor unit Indoor unit Addressing outdoor units and indoor controller installed
Cooling Heating
units are automatically done just by
• Select operation mode
pressing the button.
(Air circulation, cooling, heating)
• Mode lock for heating & cooling
mixing error-proof during the
Wired remote Wired remote Wired remote change of season
control control control
‘09 New Feature
MULTI V Inverter system offers one of the world’s • DC Inverter Compressor & Fan motor

largest capacity units, essential for high-rise buildings. • Black Box Function
• Night Silent Operation
We are proud to say the system will ensure the highest
• Fault Detect & Diagnosis
level of customer satisfaction.
• Pump Down & Pump Out

Separate Front Panel


• Easy access to main PCB (DIP switch)
• Convenient during service and start-up
• Benefits for technician, installer

Outdoor Unit_MULTI V PLUS II


Close Open

• Safety chassis • Swing control box Other Features


• Resistant to dust, rain, corrosion
* Specifications
and others HP 5 6 8 10 12 14 16
Model Combination unit ARUN50LT2 ARUN60LT2 ARUN80LT2 ARUN100LT2 ARUN120LT2 ARUN140LT2 ARUN160LT2
• Convenient maintenance due to swing

LG Air Conditioners System


Independent unit ARUN50LT2 ARUN60LT2 ARUN80LT2 ARUN100LT2 ARUN120LT2 ARUN140LT2 ARUN160LT2
door type control box
• Easy to handle through fork lift slot Capacity Cooling kW 14.0 16.0 22.4 28.0 33.6 39.2 44.8
Heating kW 15.8 18.0 25.2 31.5 37.8 44.1 50.4
• Strong base-pan support
Power Cooling kW 3.75 4.25 5.28 7.16 9.08 11.85 14.00
Input Heating kW 4.00 4.55 5.73 7.33 9.05 10.60 12.40
COP Cooling 3.73 3.76 4.24 3.91 3.70 3.31 3.20
• Easy to handle • Strong base-pan Heating 3.95 3.96 4.40 4.30 4.18 4.16 4.06
Power Supply Ø, V, Hz

24_25
3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm 806×1607×730 806×1607×730 1280×1607×730 1280×1607×730 1280×1607×730 1280×1607×730 1280×1607×730
Weight kg 175 175 240 285 285 285 285
Color Warm Gray
Noise level dBA±3 56 56 58 58 58 58 58
Fan Type Propeller Fan (DC INV)
Air flow rate [CMM] 105 105 190 190 190 190 190
Compressor Type DC Inverter Scroll DC Inverter Scroll / Constant speed Scroll
Number of compressors 1 1 1 2 2 2 2
Heat Exchanger Gold fin
Refrigerant Type R410A
Charge kg 4.5 4.5 8 8 8 8 8
Control EEV
Refrigerant Type FVC68D(PVE)
Oil Charge l 2.3 2.3 3.3 5.6 5.6 5.6 5.6
Piping Liquid Pipes mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Connections Gas Pipes mm(inch) Ø15.88(5/8) Ø19.05(3/4) Ø19.05(3/4) Ø22.2(7/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8)
Number of outdoor unit 1 1 1 1 1 1 1
Number of maximum connectable indoor units * 8(12) 9(14) 13(20) 16(25) 19(30) 23(35) 26(40)
Ratio of the connectable indoor units 50~200%
Longest piping length / Level difference ** 200m/100m
Check up the note, refer to on the 27 page.
MULTI V PLUS II ensures economic life with high energy efficiency!!

* Specifications * Specifications
HP 18 20 22 24 26 28 30 32 HP 50 52 54 56 58 60 62 64
Model Combination unit ARUN180LT2 ARUN200LT2 ARUN220LT2 ARUN240LT2 ARUN260LT2 ARUN280LT2 ARUN300LT2 ARUN320LT2 Model Combination unit ARUN500LT2 ARUN520LT2 ARUN540LT2 ARUN560LT2 ARUN580LT2 ARUN600LT2 ARUN620LT2 ARUN640LT2
Independent unit ARUN120LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 Independent unit ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
ARUN60LT2 ARUN60LT2 ARUN60LT2 ARUN80LT2 ARUN120LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
ARUN140LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
Capacity Cooling kW 50.4 56.0 61.6 67.2 72.8 78.4 84.0 89.6 ARUN80LT2 ARUN80LT2 ARUN80LT2 ARUN80LT2 ARUN100LT2 ARUN120LT2 ARUN140LT2 ARUN160LT2
Heating kW 56.7 63.0 69.3 75.6 81.9 88.2 94.5 100.8 Capacity Cooling kW 140 145.6 151.2 156.8 162.4 168 173.6 179.2
Power Cooling kW 13.33 16.10 18.25 19.28 20.93 23.70 25.85 28.00 Heating kW 157.5 163.8 170.1 176.4 182.7 189 195.3 201.6
Input Heating kW 13.60 15.15 16.95 18.13 19.65 21.20 23.00 24.80 Power Cooling kW 40.83 42.98 45.13 47.28 49.16 51.08 53.85 56.00
COP Cooling 3.78 3.48 3.38 3.49 3.48 3.31 3.25 3.20 Input Heating kW 37.53 39.33 41.13 42.93 44.53 46.25 47.80 49.60
Heating 4.17 4.16 4.09 4.17 4.17 4.16 4.11 4.06 COP Cooling 3.43 3.39 3.35 3.32 3.30 3.29 3.22 3.20
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 Heating 4.20 4.16 4.14 4.11 4.10 4.09 4.09 4.06
Dimensions(WxHxD) mm (1280×1607×730) (1280×1607×730) (1280×1607×730) (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
+(806×1607×730) +(806×1607×730) +(806×1607×730) Dimensions(WxHxD) mm (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4
Weight kg 285+175 285+175 285+175 285+240 285x2 285x2 285x2 285x2 Weight kg 285X3+240 285X3+240 285X3+240 285X3+240 285x4 285x4 285x4 285x4
Color Warm Gray Color Warm Gray
Noise level dBA±3 60 60 60 61 61 61 61 61 Noise level dBA±3 64 64 64 64 64 64 64 64
Fan Type Propeller Fan(DC INV) Fan Type Propeller Fan(DC INV)
Air flow rate [CMM] 295 295 295 380 380 380 380 380 Air flow rate [CMM] 760 760 760 760 760 760 760 760
Compressor Type DC Inverter Scroll / Constant speed Scroll Compressor Type DC Inverter Scroll / Constant speed Scroll
Number of compressors 3 3 3 3 4 4 4 4 Number of compressors 7 7 7 7 8 8 8 8
Heat Exchanger Gold fin Heat Exchanger Gold fin

Outdoor Unit_MULTI V PLUS II


Refrigerant Type R410A Refrigerant Type R410A
Charge kg 4.5+8 4.5+8 4.5+8 8+8 8+8 8+8 8+8 8+8 Charge kg 8+8+8+8 8+8+8+8 8+8+8+8 8+8+8+8 8+8+8+8 8+8+8+8 8+8+8+8 8+8+8+8
Control EEV Control EEV
Refrigerant Type FVC68D(PVE) Refrigerant Type FVC68D(PVE)
Oil Charge l 5.6+2.3 5.6+2.3 5.6+2.3 5.6+3.3 5.6x2 5.6x2 5.6x2 5.6x2 Oil Charge l 5.6X3+3.3 5.6X3+3.3 5.6X3+3.3 5.6X3+3.3 5.6x4 5.6x4 5.6x4 5.6x4
Piping Liquid Pipes mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Piping Liquid Pipes mm(inch) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4)
Connections Gas Pipes mm(inch) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Connections Gas Pipes mm(inch) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8)
Number of outdoor unit 2 2 2 2 2 2 2 2 Number of outdoor unit 4 4 4 4 4 4 4 4
Number of maximum connectable indoor units * 29(36) 32(40) 35(44) 39(48) 42(52) 45(56) 49(60) 52(64) Number of maximum connectable indoor units 64 64 64 64 64 64 64 64
Ratio of the connectable indoor units 50~160% Ratio of the connectable indoor units 50~130%
Longest piping length / Level difference ** 200m/100m Longest piping length / Level difference ** 200m/100m

* The number of () means the number of max. connectable indoor units, when the connected capacity of
indoor units is in the table below.
** Conditional Application
HP 34 36 38 40 42 44 46 48 To make 40~90m of pipe length after first branch refer to the part of “installation of outdoor units” in PDB
Model Combination unit ARUN340LT2 ARUN360LT2 ARUN380LT2 ARUN400LT2 ARUN420LT2 ARUN440LT2 ARUN460LT2 ARUN480LT2 Note :
Independent unit ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2

LG Air Conditioners System


1. Capacities are based on the following conditions
ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
ARUN60LT2 ARUN60LT2 ARUN60LT2 ARUN80LT2 ARUN140LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
Capacity Cooling kW 95.2 100.8 106.4 112.0 117.6 123.2 128.8 134.4 Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Heating kW 107.1 113.4 119.7 126.0 132.3 138.6 144.9 151.2 Level difference of zero Level difference of zero
Power Cooling kW 27.95 30.10 32.25 33.28 35.55 37.70 39.85 42.00
2. Capacities are net capacities
Input Heating kW 25.75 27.55 29.35 30.53 31.80 33.60 35.40 37.20 3. Due to our policy of innovation some specifications may be changed without notification
COP Cooling 3.41 3.35 3.30 3.37 3.31 3.27 3.23 3.20 4. EEV : Electronic Expansion Valve
Heating 4.16 4.12 4.08 4.13 4.16 4.13 4.09 4.06
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm

26_27
(1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3
CAUTION
+(806×1607×730) +(806×1607×730) +(806×1607×730)
• A combination operation over 100% cause to reduce each indoor unit capacity
Weight kg 285x2+175 285x2+175 285x2+175 285x2+240 285×3 285×3 285×3 285×3
Color • Combination ratio(50~200%)
Warm Gray
Noise level dBA±3 62 62 62 63 63 63 63 63 No. of outdoor unit Connection Capacity
Fan Type Propeller Fan(DC INV) Single unit 200%
Air flow rate [CMM] 485 485 485 570 570 570 570 570 Double unit 160%
Compressor Type DC Inverter Scroll / Constant speed Scroll Triple unit 130%
Number of compressors 5 5 5 5 6 6 6 6 Over triple unit 130%

Heat Exchanger Gold fin


We can guarantee the operation only within 130% Combination.
Refrigerant Type R410A
If you want to connect more than 130% combination, please contact us and discuss the requirement like below.
Charge kg 4.5+8+8 4.5+8+8 4.5+8+8 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units.
Control EEV 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance.
Refrigerant Type FVC68D(PVE) 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
Oil Charge l 5.6x2+2.3 5.6x2+2.3 5.6x2+2.3 5.6x2+3.3 5.6x3 5.6x3 5.6x3 5.6x3
Piping Liquid Pipes mm(inch) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4)
Connections Gas Pipes mm(inch) Ø34.9(1 3/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8)
Number of outdoor unit 3 3 3 3 3 3 3 3
Number of maximum connectable indoor units 55 58 61 64 64 64 64 64
Ratio of the connectable indoor units 50~130%
Longest piping length / Level difference ** 200m/100m
Simultaneous heating and cooling with one outdoor
TECHNOLOGY
Your life will be upgraded through the state-of-
unit, MULTI V SYNC II. Your environment is ensured of the-art technology of MULTI V SYNC II.
optimum conditions regardless of season or space.

Heating & Cooling


Heating Cooling Synchronous Operation
• High COP up to 6.3
- When, cooling(40%) + heating(60%)
> Cooling
• Energy consumption can be decreased by 30%

Max. COP (6.3)

Coefficient of Performance(COP)
40

Outdoor Unit_MULTI V SYNC II


* Outdoor temperature
Office Equipment room : 7°C DB / 6°C WB
> Heating * Indoor temperature
: 20°C DB / 15°C WB
Heating <
Heating operation ratio (%)

Long Piping Length


1st branch to
• MULTI V SYNC II
Level farthest indoor
40[90m**] Total piping length 1000m
difference
100m 15m
Longest piping length 150m(200m**)
Longest Longest piping length after 1st branch 40m[90m**]
piping length Level difference between ODU~IDU 100m

LG Air Conditioners System


Cooling < 150(200m**)
Level difference between IDU~IDU 15m
Total piping Level difference between ODU~ODU 5m
length 1000m • MULTI V SYNC II • Refer to the specifications for more information
** Conditional application
To make 40~90m of pipe length after first branch,
refer to the part of “installation of outdoor units” in PDB

AMC (Advanced Mode Change)

28_29
AMC control provides an optimal cycle
operation under any conditions.
Optimum area
- Real time pressure control
- Optimal cycle in optimum area
- Needed time to change mode : Max. 3min

Cooling
Wide Operation Range
Wide operation range
- Heating mode : - 20°C WB ~ 16°C WB
Synchronous
Operation area - Cooling mode : - 5°C DB ~ 43°C DB
- Synchronous mode : -10°C DB ~ 27°C DB
Enjoy a clean &
comfortable life with MULTI V.
Heating
Simultaneous heating and cooling with one outdoor
COMFORT
MULTI V SYNC II ensures the comfort of all users
unit, MULTI V SYNC II. Your environment is ensured of with flexible design and easy installation.
optimum conditions regardless of season or space.

• Double spiral tube heat exchanger High Efficiency Heat • MULTI V SYNC II Fast Response of Mode
Recovery Unit Change
Linear Heating Cooling
From outdoor
expansion valve • High efficient double spiral tube When the user wants to change the indoor
type SCI circuit unit’s operating mode (ex. cooling > heating),
MULTI V SYNC II takes less time compared
To indoor • Maximum 4 indoor units connectable Max. 3minutes to the conventional. This fast response of
2 phase fluid
per one HR unit mode change provides a more pleasant and

Outdoor Unit_MULTI V SYNC II


comfortable air conditioning.
• Easy installation with auto piping
• Conventional
detect function
Heating Cooling

PRHR020 PRHR030 PRHR040

About 20minutes

• MULTI V SYNC II Flexible Connection of


HR Unit • MULTI V SYNC II • Conventional Excellent Multiple HR Unit
LG’s heat recovery unit allows flexible LG’s HR unit provides the flexible and
connection both in series and in a row. 3 Piping
HR unit
3 Piping
convenient installation with lower cost.
In series HR unit

LG Air Conditioners System


2 Piping 2 Piping
• Conventional LG needs less installation cost than the conventional
LG Conventional
Y branch 12 unit 57 unit
LG unique LG unique 15m HR unit 5 unit 20 unit
Y branch only Impossible
Total piping length 690m 840m
* Assumed with 5 stories building

30_31
Impossible In series only
20m
Y Branch

• MULTI V SYNC II • Conventional Convenient Free Zoning


MULTI V SYNC II provides perfect
Free zoning! Inconvenient zoning!
individual zoning in each rooms for Change point (Heat>Cool) Auto Changeover
the user’s convenience. Temp
Change point (Cool>Heat) Auto changeover automatically change
operating mode cool and heat, to maintain
+∆T optimum room temperature, so no need of
-∆T
changing the mode during the change of
season.

Time
Same mode operation
in the different zones
MULTI V SYNC II simultaneous heating and cooling from a single outdoor unit!
‘09 New Feature
• DC Inverter Compressor & Fan motor
• Black Box Function
* Specifications
• Night Silent Operation HP 22 24 26 28 30 32 34
Model Combination unit ARUB220LT2 ARUB240LT2 ARUB260LT2 ARUB280LT2 ARUB300LT2 ARUB320LT2 ARUB340LT2
• Fault Detect & Diagnosis Independent unit ARUB140LT2 ARUB160LT2 ARUB140LT2 ARUB140LT2 ARUB160LT2 ARUB160LT2 ARUB140LT2
• Pump Down & Pump Out ARUB80LT2 ARUB80LT2 ARUB120LT2 ARUB140LT2 ARUB140LT2 ARUB160LT2 ARUB120LT2
ARUB80LT2
Capacity Cooling kW 61.6 67.2 72.8 78.4 84.0 89.6 95.2
Heating kW 69.3 75.6 81.9 88.2 94.5 100.8 107.1
Power Cooling kW 17.13 19.28 20.93 23.70 25.85 28.00 26.21
Input Heating kW 16.33 18.13 19.65 21.20 23.00 24.80 25.38
COP Cooling 3.60 3.49 3.48 3.31 3.25 3.20 3.63
Heating 4.24 4.17 4.17 4.16 4.11 4.06 4.22
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x3
Weight kg 240+285 240+285 285+285 285+285 285+285 285+285 240+285+285
Color Warm Gray
Noise level dBA±3 61 61 61 61 61 61 63
Fan Type Propeller Fan(DC INV)
Air flow rate [CMM]
* Specifications Compressor Type
380 380 380 380 380
DC Inverter Scroll / Constant speed Scroll
380 570

HP 8 10 12 14 16 18 20 Number of compressors 3 3 4 4 4 4 5
Model Combination unit ARUB80LT2 ARUB100LT2 ARUB120LT2 ARUB140LT2 ARUB160LT2 ARUB180LT2 ARUB200LT2 Heat Exchanger Gold fin
Independent unit ARUB80LT2 ARUB100LT2 ARUB120LT2 ARUB140LT2 ARUB160LT2 ARUB100LT2 ARUB120LT2 Refrigerant Type R410A

Outdoor Unit_MULTI V SYNC II


ARUB80LT2 ARUB80LT2 Charge kg 8+8 8+8 8+8 8+8 8+8 8+8 8+8+8
Control EEV
Capacity Cooling kW 22.4 28.0 33.6 39.2 44.8 50.4 56.0 Refrigerant Type FVC68D(PVE)
Heating kW 25.2 31.5 37.8 44.1 50.4 56.7 63.0 Oil Charge l 5.6+3.3 5.6+3.3 5.6+5.6 5.6+5.6 5.6+5.6 5.6+5.6 5.6+5.6+3.3
Power Cooling kW 5.28 7.16 9.08 11.85 14.00 12.44 14.36 Piping Liquid(flare) mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4)
Input Heating kW 5.73 7.33 9.05 10.60 12.40 13.06 14.78 Connections Suction Gas mm(inch) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8)
COP Cooling 4.24 3.91 3.70 3.31 3.20 4.05 3.90 Discharge Gas mm(inch) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8)
Heating 4.40 4.30 4.18 4.16 4.06 4.34 4.26 Number of outdoor unit 2 2 2 2 2 2 3
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 Number of maximum connectable indoor units * 35(44) 39(48) 42(52) 45(56) 49(60) 52(64) 55
Dimensions(WxHxD) mm 1280x1607x730 1280x1607x730 1280x1607x730 1280x1607x730 1280x1607x730 (1280x1607x730)x2 (1280x1607x730)x2 Ratio of the connectable indoor units 50~160% 50~130%
Weight kg 240 285 285 285 285 240+285 240+285 Longest piping length / Level difference ** 200m/100m
Color Warm Gray
Noise level dBA±3 58 58 58 58 58 61 61
Fan Type Propeller Fan(DC INV)
Air flow rate [CMM] 190 190 190 190 190 380 380 HP 36 38 40 42 44 46 48
Compressor Type DC Inverter Scroll DC Inverter Scroll / Constant speed Scroll
Model Combination unit ARUB360LT2 ARUB380LT2 ARUB400LT2 ARUB420LT2 ARUB440LT2 ARUB460LT2 ARUB480LT2
Number of compressors 1 2 2 2 2 3 3 Independent unit ARUB140LT2 ARUB160LT2 ARUB160LT2 ARUB160LT2 ARUB160LT2 ARUB160LT2 ARUB160LT2
Heat Exchanger Gold fin

LG Air Conditioners System


ARUB140LT2 ARUB140LT2 ARUB160LT2 ARUB160LT2 ARUB140LT2 ARUB160LT2 ARUB160LT2
Refrigerant Type R410A
ARUB80LT2 ARUB80LT2 ARUB80LT2 ARUB100LT2 ARUB140LT2 ARUB140LT2 ARUB160LT2
Charge kg 8 8 8 8 8 8+8 8+8 Capacity Cooling kW 100.8 106.4 112.0 117.6 123.2 128.8 134.4
Control EEV Heating kW 113.4 119.7 126.0 132.3 138.6 144.9 151.2
Refrigerant Type FVC68D(PVE) Power Cooling kW 28.98 31.13 33.28 35.16 37.7 39.85 42.0
Oil Charge l 3.3 5.6 5.6 5.6 5.6 5.6+3.3 5.6+3.3 Input Heating kW 26.93 28.73 30.53 32.13 33.6 35.40 37.2
Piping Liquid(flare) mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8) Ø15.88(5/8) COP Cooling 3.48 3.42 3.37 3.34 3.27 3.23 3.20
Connections Suction Gas mm(inch) Ø19.05(3/4) Ø22.2(7/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Heating 4.21 4.17 4.13 4.12 4.13 4.09 4.06
Discharge Gas mm(inch) Ø15.88(5/8) Ø19.05(3/4) Ø19.05(3/4) Ø22.2(7/8) Ø22.2(7/8) Ø22.2(7/8) Ø22.2(7/8) Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Number of outdoor unit 1 1 1 1 1 2 2 Dimensions(WxHxD) mm

32_33
(1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3
Number of maximum connectable indoor units * 13(20) 16(25) 19(30) 23(35) 26(40) 29(36) 32(40) Weight kg 240+285+285 240+285+285 240+285+285 285+285+285 285+285+285 285+285+285 285+285+285
Ratio of the connectable indoor units 50~200% 50~160% Color Warm Gray
Longest piping length / Level difference ** 200m/100m Noise level dBA±3 63 63 63 63 63 63 63
Fan Type Propeller Fan(DC INV)
* The number of () means the number of max. connectable indoor units, when the connected capacity of indoor units is in the table below.
Air flow rate [CMM] 570 570 570 570 570 570 570
** Conditional Application
To make 40~90m of pipe length after first branch refer to the part of “installation of outdoor units” in PDB Compressor Type DC Inverter Scroll / Constant speed Scroll
Number of compressors 5 5 5 6 6 6 6
Note :
Heat Exchanger Gold fin
1. Capacities are based on the following conditions
Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Refrigerant Type R410A
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Charge kg 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8
Interconnecting piping length 7.5m Interconnecting piping length 7.5m Control EEV
Level difference of zero Level difference of zero Refrigerant Type FVC68D(PVE)
2. Capacities are net capacities Oil Charge l 5.6+5.6+3.3 5.6+5.6+3.3 5.6+5.6+3.3 5.6+5.6+5.6 5.6+5.6+5.6 5.6+5.6+5.6 5.6+5.6+5.6
3. Due to our policy of innovation some specifications may be changed without notification Piping Liquid(flare) mm(inch) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4)
4. EEV : Electronic Expansion Valve
Connections Suction Gas mm(inch) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8)
Discharge Gas mm(inch) Ø28.58(1 1/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8)
CAUTION We can guarantee the operation only within 130% Combination.
If you want to connect more than 130% combination, please contact us and discuss the Number of outdoor unit 3 3 3 3 3 3 3
• A combination operation over 100% cause to reduce each indoor unit capacity requirement like below. Number of maximum connectable indoor units 58 61 64 64 64 64 64
• Combination ratio(50~200%)
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended Ratio of the connectable indoor units 50~130%
No. of outdoor unit Connection Capacity in all the indoor units.
Single unit 200% 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according Longest piping length / Level difference ** 200m/100m
Double unit 160% to the headquarter guidance.
Triple unit 130% 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
Economic and aesthetic space design MULTI V
COMFORT & SILENCE
The concept of the balcony is changed with
SPACE II is ideal for refined and luxurious living the outdoor unit that does not generate hot air.
spaces. Low noise and vibration technology of MULTI V
SPACE II ensures a quiet environment.

• MULTI V SPACE II Front Suction & Front


Discharge
Hot air
Building wind • Right and left side air flow system
• High speed air discharging (7~8m/sec)
• No interference between each floors
(Efficiency reduction due to hot air back flow)
7m/s 7m/s

Outdoor Unit_MULTI V SPACE II


• Conventional Interference
between floors!

Right outoor Left outoor


unit unit

No efficiency reduction!

• MULTI V SPACE II • Conventional Quiet Operation


The noise and vibration are reduced by

LG Air Conditioners System


- Front discharge
- Sealed structure of outdoor unit

The indoor noise level is maintained at


30~40dBA, as quiet as being in the library

34_35
• LG patents : 57items LG Patent For MULTI V SPACE II
01 All technologies in the MULTI V SPACE II
which make it a distinctive, unique unit
02 have been applied for patents domestically
and internationally. and, some of them
03
have already been registered.
04
01 Whole structure (8 items)

05 02 Air handler structrue (18 items)


03 Separation of suction & discharge (6 items)
06 04 3-side heat exchange structure (3 items)
05 Louver structure /control (20 items)
06 Electrical part(2 items)
Enjoy a clean &
comfortable life with MULTI V.
‘09 New Feature
Economic and aesthetic space design MULTI V • DC Inverter Compressor & Fan Motor

SPACE II is ideal for refined and luxurious living • Blackbox Function


• Night Silent Operation
spaces.
• Pump Down

Duct application Fan RPM Control


(E.S.P & Noise Control)
• Enhanced installation flexibility
Duct
(Duct application)
• No need of high static pressure
exhaust fan and air guide
Discharging

Outdoor Unit_MULTI V SPACE II


• Keeping capacity and noise level as desired

How to set up
- E.S.P control
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Step 1 >4mmAq < ESP < 6mmAq
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Step 2 >6mmAq < ESP < 8mmAq
* Specifications
1 2 3 4 5 6 7 8 9 10 11 12 13 14 HP 6 8
Step 3 >8mmAq < ESP < 10mmAq Model Independent unit ARUN60LR2 (Right Discharge) ARUN80LR2 (Right Discharge)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
ARUN60LL2 (Left Discharge) ARUN80LL2 (Left Discharge)
Step 4 >10mmAq < ESP < 12mmAq Capacity Cooling kW 16.0 21.7
Heating kW 18.0 23.0
Power Cooling kW 4.7 6.7
- Noise control
Input Heating kW 4.9 6.7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Low blowing noise COP Cooling kW 3.40 3.24
> Max - 100 rpm Heating kW 3.67 3.43

LG Air Conditioners System


Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm 750 x 1790 x 650 750 x 1790 x 650
Weight kg 200 200
4-Step Modularized Design Color Warm Gray
Noise level dBA±3 49 53
• Modularized design of the outdoor E.S.P range mmAq 4~12 4~12
Fan Type Sirocco Fan
unit provides simpler installation
Air flow rate [CMM] 100 100
and maintenance. Compressor Type DC INV Scroll

36_37
• Outdoor unit can be installed Number of compressors 1 1
Heat Exchanger Gold Fin
according to overall building Refrigerant Type R410A
1steps 2steps 3steps 4steps construction schedule.
Louver frame System louver Mechanical parts Fan parts Charge kg 5.2 5.2
Control EEV
• Louver is provided locally Refrigerant Type FVC68D(PVE)
Oil Charge l 2.3 2.3
Piping Liquid(flare) mm(inch) 9.52(3/8) 9.52(3/8)
Connections Gas(Bazing) mm(inch) 19.05(3/4) 19.05(3/4)
Number of outdoor unit 1 1
Number of maximum connectable indoor units 9 13
Ratio of the connectable indoor units 50~130%
Longest piping length / Level difference 150m/50m
* Preliminary data (8HP model)
Note :
1. Capacities are based on the following conditions
Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Level difference of zero Level difference of zero
2. Capacities are net capacities
*6HP (ARUN60LR2, ARUN60LL2) 3. Due to our policy of innovation some specifications may be changed without notification
*8HP (ARUN80LR2, ARUN80LL2) 4. EEV : Electronic Expansion Valve
Indoor unit
If you need a highly efficient air conditioning
system in your building, MULTI V is the right
choice for you.

Wall Mounted

Mirror

Indoor Unit
4Way Casstte

2Way Casstte

1Way Casstte

Low Static

LG Air Conditioners System


Built-in

High Static

38_39
Ceiling & Floor
M U LT I V
indoor
Ceiling Suspended

49 Wall mounted
50 ARTCOOL Floor Standing
52 Ceiling Cassette - With Case

56 Ceiling Concealed Duct


60 Ceiling & Floor
Floor Standing
61 Ceiling Suspended - Without Case

62 Floor standing
LG has been able to create a design conscious indoor unit that • Aesthetic Design
compliments any interior decoration. And they have improved • Low Noise
air flow innovatively to realize world’s lowest noise, and provide • 4 Vane Independent Operation
a more pleasant and convenient indoor environment.
• Auto Elevation Grille

Aesthetic Design Low Noise


You no longer have to be told what your Super light BLDC motor guarantees
air conditioner should look like. your enhanced comfortable indoor
With LG’s revolutionary ARTCOOL photo environment.
changeable, you can simply change the
look of your air conditioner to what you
want, when you want to.
ARTCOOL series with outstanding designs have Typing Office Conversation Library 4 way CST
received International Forum Design Award,
Reddot Design Award and G Mark.
4 Vanes Independent

Indoor Unit
1 Vane, 1 Motor
Operation
Vane angle control satisfies both users
- How to change the picture who like direct wind and indirect wind.
and also it prevents cold air draft.
Direct air flow Indirect air flow

All vane operation Individual vane operation • Easy vane angle control with a remote controller

1 : 20 °

0 : 30 °

LG Air Conditioners System


Air flow rate control Individual vane angel control
2 : 40 °
5 : 70 ° 4 : 60 ° 3 : 50 °

- Panel type

Auto Elevation Grille

40_41
Easy filter cleaning with elevation grille
Silver 07/09/12GSFV2 Gold 07/09/12GSFG2 Red 07/09/12GSFE2 White silver 07/09/12GSFH2 4 Way
4.5m
- Installed inside main body
- Auto horizontal level
- 4 points support
Conventional
3.5m - Memory for user’s level
- Max. 4.5m length
- ARTCOOL Mirror

4-Point support structure Auto horizontal control Memory for user’s level Auto bottom detection

Mirror 07/09/12/15GSER2 Silver 07/09/12/15GSEV2 Blue 07/09/12/15GSEB2

Max. 4.5m
18/24GS8R2 18/24GS8V2 18/24GS8B2

STOP
Memory

*Available for 24k ~ 48k Btu/h


• Wide Jet Vane
LG has been able to create a design conscious indoor unit that
• High Ceiling Mode
compliments any interior decoration. And they have improved
• Flexible Connection
air flow innovatively to realize world’s lowest noise, and provide
a more pleasant and convenient indoor environment. • Appliaction of Ceiling Concealed Duct

• Appliaction of Built-in Duct

• Linear E.S.P Control

• Air flow improvement Wide Jet Vane Application of Ceiling


Improved wide and narrow vane will provide Concealed Duct
80mm Wider!! 567mm comfortable temperature distribution without It is possible to make each rooms cool
NEW air flow dead zone. & warm with installing a chamber and
487mm * For 4 way cassette (570 * 570), this function will be applied from May. a spiral duct.
Current

Highlander
Even air distribution
t
Temp.

Indoor Unit
26
25
27°C
24
23
22
21
20
19
18 Max. 9 discharging
15°C

Current Air flow dead zone


t
26
Temp.
27°C
Application of Built-in Duct
25

Built-in duct has no need of duct space


24
23
22

with using suction canvas and grille.


21
20
19
18

15°C

LG Air Conditioners System


4 way CST High Ceiling Mode
Conventional
High ceiling mode with phase-control Grille Canvas
algorithm is possible to apply as high
as 3.6m of ceiling.

42_43
Flexible Connection Linear E.S.P Control
Air volume and sound are always kept
Flexible connection of remote controller
as design regardless of E.S.P change
- Group control using this technology , you can
: 1 remote controller to several indoor units
• Optimize duct work Installation
- Second remote control • Keep capacity & sound level as desired
: 2 remote controllers to 1 indoor unit • Simplify model numbers

Easy & solid attachment to the wall The phase control motor technology
offers money saving benefit to the installer.
wall

wall

*E.S.P is easily controlled by remote controller


• Compact Size
LG has been able to create a design conscious indoor unit that
• One Touch Type Panel
compliments any interior decoration. And they have improved
• Convenient Installation
air flow innovatively to realize world’s lowest noise, and provide
a more pleasant and convenient indoor environment. • Easy Drain Installation

• 3Way Flexible Installation

• Sliding Type Filter

Compact Size Drain hose Drain pump Easy Drain Installation


The indoor unit with slim and compact It reduces the installation time by over
size has reduced the restriction which 40% with elbow-less drain hose.
enables successful installation in various
spaces. Midget drain pump covers maximum
800mm high, featuring easy piping
installation.

6.0 ~ 7.2 kW 8.3 ~ 11.0 kW * Accessory (Drain hose)


LG conventional PHDHA05T – 500mm 30EA
218mm 288mm
PHDHA07T - 700mm 30EA
PHDHA05B – 500mm 5EA

Indoor Unit
204mm 246mm PHDHA07B – 700mm 5EA

3Way Flexible Installation


One Touch Type Panel All sides (front, back, floor) are possible
to install and connect to the outdoor unit.
It provides easy installation with
a one-touch detachable panel.

LG Air Conditioners System


Back

• Coner detachable design Convenient Installation Floor


Side
Easy installation with corner
detachable decoration panel.

44_45
Refrigerant Drain leakage
Drain leakage check Hanger adjust
Sliding Type Filter
piping check check
Easy maintenance and extended
product life with sliding type anti-biotic
Anti-biotic filter Easy cleaning
filter.

Hanger adjust Hanger adjust

Sliding type
LG has been able to create a design conscious indoor unit that • Neo Plasma Air Purifying System
compliments any interior decoration. And they have improved • Digital Air Flow Control
air flow innovatively to realize world’s lowest noise, and provide • Swirl Swing
a more pleasant and convenient indoor environment.
• Child Lock Function

Polluted Air Clean Air Neo Plasma Air Purifying Digital Air Flow Control
01 02 03 04 05 System The air flow can be controlled
LG’s unique NEO Plasma air purifying to ensure maximum comfort and
system is equipped with 7 specialized filters convenience.
in 5 separate stages to enhance its cleaning
power. It reduces fine dust and mold, Normal Jet cool Sleep mode
fast & even widely speedy & powerful indirectly & softly
unpleasant odors and cigarette smoke
Odor Free! Dust Free! Allergy Free! as air passes through each filter.

Indoor Unit
Swirl swing (plaesant air) Normal air flow Swirl Swing
01 Pre Filter 05 Plasma Filter Swirl swing distributes air evenly
throughout the room to ensure a more
The antibacterial pre-filter primarily reduces The PLASMA Air Purifying System developed uniquely comfortable conditioned environment
large dust, mold and quilt dust. by LG not only reduces microscopic contaminants and
by adjusting the movement of the vane.
dust, but also reduces house mites, pollen, and pet
fur to reduce allergy and asthma symptoms.
02 Nano Carbon Filter

Nano-size carbon filters remove


fine odorous particles from the • Comparison of temperatures
household air resulting in a more
pleasant environment.

LG Air Conditioners System


What is Nano Carbon Ball? * Test Result
Microscopic sized (1/1000000000) filter 200~500nm Certification
to ensure optimal filtration of odors.

Bio Active Bacteria,


Site Virus
03 Triple Filter

The triple filter consists of three specialized filters to Nano Nano Nano Nano
Vertical Temp. differences Horizontal Temp. differences

46_47
reduce the symptoms associated with various organic Particle Particle Particle Particle

compounds including formaldehyde. It also has the


ability to reduce unpleasant odors creating a more
comfortable environment.
Active State Bacteria Selective Bacteriolysis
Capture
Regeneration
(Active State)
Indoor Temperature Distribution Chart Healthy Dehumidification
Dehumidification mode reduces
LG Healthy
Distinctions from Conventional Filters Dehumidification uncomfortable humidity from the
By increasing the vane room without over cooling.
• Nano Bio Fusion Filter angle, a better approach
of the actual temperature
The bio enzyme destroys is possible to prevent over
cell walls and nuclei of cooling.
04 Nano Bio Fusion Filter some bacteria and allergens.

Nano bio fusion filters allow their nanosize bio Conventional


enzymes to directly penetrate through cell walls • Conventional Since the surrounding
of some bacteria and allergen to decompose its temperature is measured
after the air from the unit is
cell nuclei. widely distributed, accurate
approach of the air is not
possible.
Simply inactivate Destroy bacteria but allow
bacteria part of them to survive
Wall Mounted
ARNU07GSEL2 / ARNU09GSEL2
LG has been able to create a design conscious indoor unit that
ARNU12GSEL2 / ARNU15GSEL2
compliments any interior decoration. And they have improved
air flow innovatively to realize world’s lowest noise, and provide ARNU18GS5L2 / ARNU24GS5L2
a more pleasant and convenient indoor environment.

LG Auto Clean Conventional Auto Clean


Auto clean helps to remove odor and save
clean-up time. After using airconditioner,
“Auto clean” makes the inner part of
Air conditioner dry for 30 min. It removes
mositure and mold so you can enjoy
odor-free air and save time to clean up.
1 STEP
* Specifications
Dries the evaporator with gentle Model Unit ARNU07GSEL2 ARNU09GSEL2 ARNU12GSEL2 ARNU15GSEL2 ARNU18GS5L2 ARNU24GS5L2
low noise air from the fan by

Indoor Unit
Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1
removing any remaining moisture.
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Pressing the Auto Clean button will activate Heating kW 2.5 3.2 4.0 5.0 6.3 8.0
the automatic cleaning function after the
cooling operation. Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Power Cooling W 40 40 40 40 40 40
Input Heating W 40 40 40 40 40 40
2 STEP
Power Supply Ø, V, Hz 1, 220~240, 50
Removes moulds through the Dimensions(WxDxH) mm 895x165x282 1090x178x300
neo plasma system.
Weight kg 9 9 9 9 12 12
Only the fan will operate to dry the inner part
of the air conditioner in just 30 minutes. Noise level dBA±3 37 / 33 / 23 39 / 35 / 25 41 / 36 / 27 42 / 36 / 27 44 / 40 / 36 46 / 41 / 38
Air flow rate H/M/L CMM 5.6 / 5 / 4.6 7 / 6.5 / 6 9.5 / 9 / 8.5 10.5 / 9 / 8.5 12 / 10.5 / 9 14 / 13 / 10
Neo Plasma air purifying filter o o o o o o
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Air Flow Direction Control

LG Air Conditioners System


Horizontal airflow control Vertical airflow control Drain(OD/ID) mm 20/16 20/16 20/16 20/16 20/16 20/16
Note :
Horizontal airflow control 1. Capacities are based on the following conditions
- Adjust the horizontal airflow direction by Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
manually moving the horizontal airflow Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
direction vane by hand. Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Level difference of zero Level difference of zero
2. Due to our policy of innovation some specifications may be changed without notification
Vertical airflow
- The airflow direction can be adjusted as

48_49
desired by using the remote controller.
* Accessories
Model ARNU07GSEL2 ARNU09GSEL2 ARNU12GSEL2 ARNU15GSEL2 ARNU18GS5L2 ARNU24GS5L2

Weekly Program Dry Contact


Without case(1 contact point)
With case(1 contact point)
PQDSA
PQDSB/ PQDSB1
SUNDAY With case(2 contact point) PQDSBC
The operator can set an on/off
MONDAY
reservation of the air conditioner for
TUESDAY a period of one week.
WEDNESDAY Wired remote controller Wireless remote controller
LCD Wired Remote Controller
THURSDAY
• On/Off
FRIDAY
• Test run mode
SATURDAY • Self-diagnosis
• 3-step fan speed selection
• Operation indication
• Room temperature
Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
Mirror
ARNU07GSF*2 / ARNU09GSF*2 ARNU07GSE*2 / ARNU09GSE*2 / ARNU12GSE*2
ARNU12GSF*2 ARNU15GSE*2 / ARNU18GS8*2 / ARNU24GS8*2
* 1: Photo changeable, V: Silver, * R : Mirror, B : Blue, V : Silver
E: Red, G: Gold, H: White Silver

Mirror

Silver Gold

Indoor Unit_ARTCOOL Gallery / Mirror


Silver

Red White Silver


Blue

* Photo changeable * Panel type


* Specifications * Specifications
Model Unit ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2 Model Unit ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2
Capacity Cooling kW 2.2 2.8 3.6 Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 7,500 9,600 12,300 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Heating kW 2.5 3.2 4.0 Heating kW 2.5 3.2 4.0 5.0 6.3 8.0
Btu/h 8,500 10,900 13,600 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Power Cooling W 35 35 35 Power Cooling W 40 40 40 40 40 40
Input Heating W 35 35 35 Input Heating W 40 40 40 40 40 40
Power Supply Ø, V, Hz 1, 220~240, 50 Power Supply Ø, V, Hz 1, 220~240, 50
Dimensions(WxDxH) mm 600x146x600 Dimensions(WxDxH) mm 915x169x282 1170x173x315

LG Air Conditioners System


Weight kg 15 15 15 Weight kg 11.2 11.2 11.2 11.2 13 13
Noise level dBA±3 38 / 32 / 27 38 / 32 / 27 44 / 38 / 32 Noise level dBA±3 37 / 33 / 23 39 / 35 / 25 41 / 36 / 27 42 / 36 / 27 37 / 34 / 31 43 / 37 / 32
Air flow rate H/M/L CMM 8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 9.3 / 7.7 / 6.0 Air flow rate H/M/L CMM 7/6/4 8/7/5 10 / 8 / 6 10.5 / 8 / 6 14.4 / 13 / 11 17.9 / 14.4 / 12
Neo Plasma air purifying filter o o o Neo Plasma air purifying filter o o o o o o
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain(OD/ID) mm 16.2/12.2 16.2/12.2 16.2/12.2 Drain(OD/ID) mm 20/16 20/16 20/16 20/16 20/16 20/16
* Check up the note, refer to on the 49 page. * Preliminary data (18 ~ 24k model) * Check up the note, refer to on the 49 page.

50_51
* Accessories * Accessories
Model ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2 Model ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
4 Way Cassette (570*570) 4 Way Cassette (840*840)
ARNU05GTRC2 / ARNU07GTRC2 ARNU24GTPC2 / ARNU28GTPC2
ARNU09GTRC2 / ARNU12GTRC2 ARNU36GTNC2 / ARNU42GTMC2
ARNU15GTQC2 / ARNU18GTQC2 ARNU48GTMC2

Indoor Unit_Ceiling Cassette


* Specifications * Specifications
Model Unit ARNU05GTRC2 ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU15GTQC2 ARNU18GTQC2 Model Unit ARNU24GTPC2 ARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2
Capacity Cooling kW 1.6 2.2 2.8 3.6 4.5 5.6 Capacity Cooling kW 7.1 8.2 10.6 12.3 14.1
Btu/h 5,500 7,500 9,600 12,300 15,400 19,100 Btu/h 24,200 28,000 36,200 42,000 48,100
Heating kW 1.8 2.5 3.2 4.0 5.0 6.3 Heating kW 8.0 9.2 11.9 13.8 15.9
Btu/h 6,100 8,500 10,900 13,600 17,100 21,500 Btu/h 27,300 31,500 40,600 43,800 51,200
Power Cooling W 45 45 45 45 45 45 Power Cooling W 33 33 144 144 144
Input Heating W 45 45 45 45 45 45 Input Heating W 33 33 144 144 144
Power Supply Ø, V, Hz 1, 220 ~ 240, 50 Power Supply Ø, V, Hz 1, 220 ~ 240, 50
Dimensions Body mm 570 x 570 x 214 570 x 570 x 256 Dimensions Body mm 840x840x204 840x840x246 840x840x288
(WxDxH) Front panel mm 700x700x30 (WxDxH) Front Panel mm 950x950x25
Weight Body kg 13.1 13.1 14.2 14.2 15.5 15.5 Weight Body kg 20.8 20.8 23.5 25.6 25.6
Front panel 2.3 2.3 2.3 2.3 2.5 2.5 Front Panel kg 4.5 4.5 4.5 4.5 4.5
Panel Color Morning Fog Panel Color Morning Fog
Noise level dBA±3 36 / 35 / 33 36 / 35 / 33 36 / 35 / 34 36 / 35 / 34 37 / 36 / 35 38 / 37 / 36 Noise level dBA±3 38 / 35 / 31 39 / 38 / 32 43 / 40 / 39 47 / 44 / 42 48 / 47 / 45

LG Air Conditioners System


Air flow rate H/M/L CMM 7.5 / 7 / 6.6 7.5 / 7 / 6.6 8 / 7.5 / 7.1 8.7 / 8 / 7 11 / 10 / 9.3 11.2 / 11 / 10 Air flow rate H/M/L CMM 17 / 15 / 13 19 / 16 / 14 25 / 21 / 19 30 / 27 / 24 31 / 29 / 27
Neo Plasma air purifying filter o o o o o o Neo Plasma air purifying filter o o o o o
Drain Pump o o o o o o Drain Pump o o o o o
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Piping Liquid mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Connection Gas mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25 32/25 Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

* Accessories * Accessories

52_53
Model ARNU05GTRC2 ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU15GTQC2 ARNU18GTQC2 Model ARNU24GTPC2 ARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Front Panel PT-UQC
Front Panel PT-UMC
Auto Elevation Grille PTEGM0
Ventilation Kit PTVK410 / PTVK420 / PTVK 430

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
2 Way Cassette 1 Way Cassette
ARNU18GTLC2 / ARNU24GTLC2 ARNU07GTJC2 / ARNU09GTJC2
ARNU12GTJC2

Indoor Unit_Ceiling Cassette


* Specifications * Specifications
Model Unit ARNU18GTLC2 ARNU24GTLC2 Model Unit ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2
Capacity Cooling kW 5.6 7.1 Capacity Cooling kW 2.2 2.8 3.6
Btu/h 19,100 24,200 Btu/h 7,500 9,600 12,300
Heating kW 6.3 8.0 Heating kW 2.5 3.2 4.0
Btu/h 21,500 27,300 Btu/h 8,500 10,900 13,600
Power Cooling W 70 70 Power Cooling W 40 40 40
Input Heating W 70 70 Input Heating W 40 40 40
Power Supply Ø, V, Hz 1, 220 ~ 240, 50 Power Supply Ø, V, Hz 1, 220 ~ 240, 50
Dimensions Body mm 830x550x225 Dimensions Body mm 860x410x138
(WxDxH) Front Panel mm 1050x640x28.5 (WxDxH) Front Panel mm 1070x480x20
Weight Body kg 22 22 Weight Body kg 11.5 11.5 11.5
Front Panel kg 4 4 Front Panel kg 1.5 1.5 1.5

LG Air Conditioners System


Panel Color Morning Fog Panel Color Morning Fog
Noise level dBA±3 40 / 35 / 30 42 / 37 / 32 Noise level dBA±3 40 / 38 / 37 40 / 38 / 37 41 / 39 / 37
Air flow rate H/M/L CMM 13 / 12 / 10 17 / 15 / 13 Air flow rate H/M/L CMM 7.5 / 6.5 / 6 7.5 / 6.5 / 6 8/7/6
Neo Plasma air purifying filter o o Neo Plasma air purifying filter o o o
Drain Pump o o Drain Pump o o o
Piping Liquid mm(inch) Ø6.35(1/4) Ø9.52(3/8) Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Connection Gas mm(inch) Ø12.7(1/2) Ø15.88(5/8) Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain(OD/ID) mm 32/25 32/25 Drain(OD/ID) mm 32/25 32/25 32/25
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

54_55
* Accessories * Accessories
Model ARNU18GTLC2 ARNU24GTLC2 Model ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Front panel PT-HLC Front panel PT-HJC

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
Low Static Duct Built-in Duct
ARNU07GB1G2 / ARNU09GB1G2 ARNU07GB3G2 / ARNU09GB3G2
ARNU12GB1G2 / ARNU15GB1G2 ARNU12GB3G2 / ARNU15GB3G2
ARNU18GB2G2 / ARNU24GB2G2 ARNU18GB4G2 / ARNU24GB4G2

Indoor Unit_Ceiling Concealed Duct


* Specifications * Specifications
Model Unit ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2 Model Unit ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1 Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Heating kW 2.5 3.2 4.0 5.0 6.3 8.0 Heating kW 2.5 3.2 4.0 5.0 6.3 8.0
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Power Cooling W 30 30 30 30 80 80 Power Cooling W 30 30 30 30 80 80
Input Heating W 30 30 30 30 80 80 Input Heating W 30 30 30 30 80 80
Power Supply Ø, V, Hz 1, 220 ~ 240, 50 Power Supply Ø, V, Hz 1, 220~ 240, 50
Dimensions(WxDxH) mm 820x575x190 1100x575x190 Dimensions (WxDxH) mm 820x575x190 1100x575x190
Weight kg 21 21 21 21 26 26 Suction grille (WxDxH) 910x359x56 1188x359x56

LG Air Conditioners System


Noise level dBA±3 35 / 33 / 31 36 / 35 / 33 37 / 36 / 35 38 / 37 / 36 40 / 37 / 34 43 / 40 / 37 Suction canvas (WxHxD) 821x274x(45~250) 1100x274x(45~250)
E.S.P range mmAq 0~4 Weight kg 21 21 21 21 26 26
Air flow rate H/M/L CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5 11.5 / 10.5 / 9.5 16 / 14 / 12 19 / 17 / 15 Noise level dBA±3 37 / 34 / 33 39 / 35 / 34 40 / 37 / 34 41 / 40 / 37 43 / 40 / 37 46 / 43 / 37
Neo Plasma air purifying filter - - - - - - E.S.P range mmAq 0~4
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8) Air flow rate H/M/L CMM 8 / 6.5 / 5.5 9/7/6 10 / 8 / 6.5 11 / 10 / 8 14 / 12 / 10 17 / 15 / 10
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8) Neo Plasma air purifying filter - - - - - -
Drain(OD/ID) mm 32/25.4 32/25.4 32/25.4 32/25.4 32/25.4 32/25.4 Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
* Check up the note, refer to on the 49 page. Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain(OD/ID) mm 32/25.4 32/25.4 32/25.4 32/25.4 32/25.4 32/25.4

56_57
* Check up the note, refer to on the 49 page.
* Accessories * Accessories
Model ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
Model ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2
Without case(1 contact point) PQDSA
Without case(1 contact point) PQDSA
Dry Contact Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) With case(2 contact point) PQDSBC
PQDSBC
Suction Grille PBSGB30 PBSGB40
Suction Canvas PBSC30 PBSC40

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
High Static Duct High Static Duct
ARNU07GBHA2 / ARNU09GBHA2 ARNU28GBGA2 / ARNU36GBGA2
ARNU12GBHA2 / ARNU15GBHA2 ARNU42GBGA2 / ARNU48GBRA2
ARNU18GBHA2 / ARNU24GBHA2 URNU76GB8A2 / URNU96GB8A2

Indoor Unit_Ceiling Concealed Duct


* Specifications * Specifications
Model Unit ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2 Model Unit ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1 Capacity Cooling kW 8.2 10.6 12.3 14.1 22.4 28.0
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Btu/h 28,000 36,200 42,000 48,100 76,400 95,900
Heating kW 2.5 3.2 4.0 5.0 6.3 8.0 Heating kW 9.2 11.9 13.8 15.9 25.2 31.5
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Btu/h 31,500 40,600 43,800 51,200 86,000 107,500
Power Cooling W 150 150 150 150 150 150 Power Cooling W 450 450 450 450 800 800
Input Heating W 150 150 150 150 150 150 Input Heating W 450 450 450 450 800 800
Power Supply Ø, V, Hz 1, 220 ~240, 50 Power Supply Ø, V, Hz 1, 220 ~240, 50
Dimensions(WxDxH) mm 882x450x260 Dimensions(WxDxH) mm 1182x450x298 1230x590x380 1562x688x460
Weight kg 26 26 26 26 26.5 26.5 Weight kg 38 38 38 53 87 87

LG Air Conditioners System


Noise level dBA±3 34 / 33 / 32 35 / 34 / 33 37 / 35 / 34 39 / 38 / 37 42.5 / 41 / 37 45 / 43 / 41 Noise level dBA±3 44 / 42 / 40 46 / 44 / 42 48 / 46 / 45 45 / 43 / 41 50 / 48 / 48 52 / 50 / 50
E.S.P range mmAq 4~12 E.S.P range mmAq 6~16 6~14 6~12 7~20 12-25
Air flow rate H/M/L CMM 8.5 / 7.5 / 6 10 / 8.5 / 7.5 12 / 10 / 8.5 13.5 / 12 / 8.5 15.5 / 13.5 / 12.4 18.3 / 16.9 / 15.5 Air flow rate H/M/L CMM 25.9 / 24.1 / 21.8 32.3 / 29 / 25.3 34.5 / 32.3 / 30.7 44.8 / 40.6 / 33.3 64 / 50 / 50 72 / 64 / 64
Neo Plasma air purifying filter - - - - - - Neo Plasma air purifying filter - - - - - -
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8) Piping Liquid mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8) Connection Gas mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4) Ø22.2(7/8)
Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25 32/25 Drain(OD/ID) mm 32/25 32/25 32/25 32/25 32/25 32/25
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

58_59
* Accessories * Accessories
Model ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2 Model ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
Ceiling & Floor Ceiling Suspended
ARNU09GVEA2 / ARNU12GVEA2 ARNU18GVJA2 / ARNU24GVJA2

Indoor Unit_Ceiling & Floor / Ceiling Suspended


* Specifications * Specifications
Model Unit ARNU09GVEA2 ARNU12GVEA2 Model Unit ARNU18GVJA2 ARNU24GVJA2
Capacity Cooling kW 2.8 3.6 Capacity Cooling kW 5.6 7.1
Btu/h 9,600 12,300 Btu/h 19,100 24,200
Heating kW 3.2 4.0 Heating kW 6.3 8.0
Btu/h 10,900 13,600 Btu/h 21,500 27,300
Power Cooling W 30 30 Power Cooling W 63 63
Input Heating W 30 30 Input Heating W 63 63
Power Supply Ø, V, Hz 1, 220 ~ 240, 50 Power Supply Ø, V, Hz 1, 220~240, 50
Dimensions(WxDxH) mm 900x200x490 Dimensions(WxDxH) mm 950x220x650

LG Air Conditioners System


Weight kg 13.7 13.7 Weight kg 24.6 24.6
Noise level dBA±3 36 / 32 / 28 38 / 36 / 30 Noise level dBA±3 42 / 40 / 37 43 / 41 / 39
Air flow rate H/M/L CMM 7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.9 Air flow rate H/M/L CMM 16 / 14 / 12 18 / 16 / 14
Plasma air purifying filter - - Neo Plasma air purifying filter - -
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Piping Liquid mm(inch) Ø6.35(1/4) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Connection Gas mm(inch) Ø12.7(1/2) Ø15.88(5/8)
Drain(OD/ID) mm 20/16 20/16 Drain(OD/ID) mm 20/16 20/16
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

60_61
* Accessories * Accessories
Model ARNU09GVEA2 ARNU12GVEA2 Model ARNU18GVJA2 ARNU24GVJA2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
Floor Standing Floor Standing
with case without case
ARNU07GCEA2 / ARNU09GCEA2 ARNU07GCEU2 / ARNU09GCEU2
ARNU12GCEA2 / ARNU15GCEA2 ARNU12GCEU2 / ARNU15GCEU2
ARNU18GCFA2 / ARNU24GCFA2 ARNU18GCFU2 / ARNU24GCFU2

Indoor Unit_Floor Standing


* Specifications * Specifications
Model Unit ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2 ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2 Model Unit ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1 Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Heating kW 2.5 3.2 4.0 5.0 6.3 8.0 Heating kW 2.5 3.2 4.0 5.0 6.3 8.0
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Power Cooling W 30 30 30 30 80 80 Power Cooling W 30 30 30 30 80 80
Input Heating W 30 30 30 30 80 80 Input Heating W 30 30 30 30 80 80
Power Supply Ø, V, Hz 1, 220~240, 50 Power Supply Ø, V, Hz 1, 220~240, 50
Dimensions(WxDxH) mm 1067x203x635 1345x203x635 Dimensions(WxDxH) mm 978x190x639 1256x190x639

LG Air Conditioners System


Weight kg 27 27 27 27 34 34 Weight kg 20 20 20 20 27 27
Noise level dBA±3 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37 Noise level dBA±3 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
Air flow rate H/M/L CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5 11.5 / 10 / 9.5 16 / 14 / 12 18 / 16 / 14 Air flow rate H/M/L CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5 11.5 / 10 / 9.5 16 / 14 / 12 18 / 16 / 14
Plasma air purifying filter - - - - - - Plasma air purifying filter - - - - - -
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8) Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8) Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain(ID) mm 12 12 12 12 12 12 Drain(ID) mm 12 12 12 12 12 12
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.

62_63
* Accessories * Accessories
Model ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2 ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2 Model ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC

Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller

Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
Heat Recovery Ventilator
With today’s concern for a healthy indoor environment,
eco V is an integral component of HVAC system.
eco V Using in the HVAC system allows contaminants to be
removed quickly and effectively from the air-conditioned
space.

Heat Recovery Ventilator

LG’s heat recovery ventilation system,


eco V, modulates the temperature and
humidity of incoming fresh air to match
indoor conditions. A balance is achieved
between indoor and outdoor ambient,

(Heat Recovery ventilator)


enabling the cooling or heating load
placed on the air conditioning system to
be reduced significantly.

LG Air Conditioners System


64_65
eco V

62 Features
63 Installation & Maintenance
64 Line-up
66 Specifications
Features Installation
• High Efficiency Heat Exchanger & Maintenance
• Bypass Ventilation
• Strong Filter Function • Flexibility Installation
• Easy Cleaning and Changeable Filter

Supply air High Efficiency Heat Exchanger Flexibility of Installation


Efficiency and comfort is ensured by It’s possible to install the opposite direction
the high-efficiency energy recovery of upper and lower part. It needs the only one
Exhaust air central core which recovers energy inspection hole.
from the indoor air and transfers it to
Air Filter Air Filter
the fresh incoming air without mixing
airstream.
High performance filter
Outdoor air (Option)
{ Deodorization filter
Indoor air

Normal installation Reverse installation


of 2 units of 1 unit (Left unit)
Bypass Ventilation

(Heat Recovery ventilator)


• Enthalpy Heat • Bypass Mode
Exchange Mode It switches automatically the ventilation mode • Inspection hole
Damper
(Enthalpy Heat Exchange Mode / Bypass Mode)
Damper
according to the indoor/outdoor temperature. Top Low

Low Top

Easy Cleaning and Changing Filter


[Summer / Winter] [A change of season]
Door attached side panel and slide removable

LG Air Conditioners System


Enthalpy heat exchanger filter can be changed
without additional maintenance.

• Air Filter Strong Filter Function


Air filter
The air filter has collection efficiency above 80%, which
• Eco V unit • Remove side panel
means it can filter particles up to 0.3 m including tobacco
of smoke and even floating particles from yellow sand.

66_67
• HEPA+Deodorization Filter (accessory) HEPA + Deodorization filter (accessory)
The indoor air can be always kept fresh through these filters.

Yellow Sand filter (accessory)


This filter can make more comfortable and fresh
environment through removing harmful to health 5~20µm
sandy dust over 99%.

• Yellow Sand Filter (accessory) • Remove free filter • Remove heat exchanger
Dust collection efficiency (%) Pressure loss (Pa)
• High Efficiency Heat Exchanger

• Bypass Ventilation
The LG heat recovery ventilation system, eco V
• Strong Filter Function
is the solution for improving your indoor air quality.
• Flexibility of Installation

• Easy Cleaning and changeable Filter

LZ-H0106BA0 LZ-H0156BA0 LZ-H0806BA0


Power Supply [Ø,V,Hz] _ Power Supply (Ø, V, Hz) _ Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
1Ø, 220-240V, 50Hz 1Ø, 220~240V, 50Hz Dimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch)
Weight _ 67kg (147.7lb)
Dimension [WxHxD]_ Dimension (WxHxD) _
204x509x509mm 590x204x590mm
[8.03x23.23x23.23inch] (23.23x8.03x23.23 inch)

Weight_ 24kg[52.91lb] Weight _ 24kg (52.91 lb)]

LZ-H1006BA0

(Heat Recovery ventilator)


Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch)
Weight _ 67kg (147.7lb)

LZ-H0256BA0 LZ-H0356BA0
Power Supply (Ø, V, Hz) _ Power Supply (Ø, V, Hz) _
1Ø, 220~240V, 50Hz 1Ø, 220~240V, 50Hz

Dimension (WxHxD) _ Dimension (WxHxD) _


596x320x640mm 988x273x1014mm

LG Air Conditioners System


(23.46x12.60x25.20 inch) (38.9x10.75x39.92 inch)
LZ-H1506BA0
Weight _ 27kg (59.51 lb) Weight _ 45kg (99.2 lb) Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch)
Weight _ 146kg (321.9 lb)

68_69
         

LZ-H0506BA0 LZ-H2006BA0
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch) Dimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch)
Weight _ 52kg (114.7 lb) Weight _ 146kg (321.9 lb)
eco V ensures the fresh enviroment in your life!
Heat Recovery Ventilator

* Specifications * Specifications

Item Unit LZ-H0106BA0 LZ-H0156BA0 LZ-H0256BA0 LZ-H0356BA0 LZ-H0506BA0 Item Unit LZ-H0806BA0 LZ-H1006BA0 LZ-H1506BA0 LZ-H2006BA0
Nominal Capacity CMH(L/S) 100(28) 150(42) 250(69) 350(97) 500(139) Nominal Capacity CMH(L/S) 800(222) 1000(278) 1500(417) 2000(556)
Power Supply Ø,V,Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220~240, 50 Power Supply Ø,V,Hz 1, 220~240, 50 1, 220~240, 50 1, 220~240, 50 1, 220~240, 50
Step - SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW Step - SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW
Current SH/H/L Amps 0.32/0.3/0.28 0.36/0.36/0.35 0.55/0.5/0.34 1.40/1.33/0.9 1.51/1.39/1.06 Current SH/H/L Amps 2.8/2.7/2.6 3.0/2.9/2.6 5.6/5.4/5.2 6.0/5.8/5.2
Power Input SH/H/L W 68/60/50 83/80/78 130/115/80 205/195/170 260/225/200 Power Input SH/H/L W 405/360/320 560/540/470 950/925/795 1020/970/860
eco V Mode

eco V Mode
Air Flow SH/H/L CMH(L/S) 100/100/90(59/59/53) 150/150/100(42/42/28) 250/250/180(69/69/50) 350/350/210(97/97/58) 500/500/320(139/139/89) Air Flow SH/H/L CMH(L/S) 800/800/660(222/222/183) 1000/1000/800(278/278/222) 1500/1500/1200(417/417/333) 2000/2000/1600(556/556/444)
External Static Pressure SH/H/L Pa(in.wg) 40/35/30(0.16/0.14/0.12) 70/55/45(0.28/0.22/0.18) 65/50/40(0.26/0.2/0.16) 170/88/40(0.68/0.35/0.16) 150/60/28(0.60/0.24/0.11) External Static Pressure SH/H/L Pa(in.wg) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24)

(Heat Recovery ventilator)


Temperature Exchange Efficiency SH/H/L % 78/78/80 75/75/79 80/80/85 83/83/87 75/75/79 Temperature Exchange Efficiency SH/H/L % 79/79/82 75/75/78 79/79/82 75/75/78
Enthalpy Exchange Efficiency Heating(SH/H/L) % 68/68/70 62/62/69 70/70/78 80/80/85 75/75/80 Enthalpy Exchange Efficiency Heating(SH/H/L) % 70/70/75 66/66/71 70/70/75 66/66/71
Cooling(SH/H/L) % 58/58/60 55/55/59 64/64/68 78/78/83 70/70/75 Cooling(SH/H/L) % 65/65/70 61/61/66 65/65/70 61/61/66
Noise Level(Sound Level, 1.5m) SH/H/L dBA 28/26/20 32/30/22 32/28/21 33/28/23 34/32/25 Noise Level(Sound Level, 1.5m) SH/H/L dBA 36/34/30 37/35/31 39/37/33 39/37/33
Step - -/-/- -/-/- -/-/- SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW Step - SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW
Current SH/H/L Amps -/-/- -/-/- -/-/- 1.40/1.33/0.9 1.51/1.39/1.06 Current SH/H/L Amps 2.8/2.7/2.6 2.8/2.7/2.4 5.6/5.4/5.2 5.6/5.4/4.8
Power Input SH/H/L W -/-/- -/-/- -/-/- 205/195/170 260/225/200 Power Input SH/H/L W 405/360/320 560/540/470 950/925/795 1020/970/860
Bypass Mode

Bypass Mode
Air Flow SH/H/L CMH(L/S) -/-/- -/-/- -/-/- 350/350/210(97/97/58) 500/500/320(139/139/89) Air Flow SH/H/L CMH(L/S) 800/800/660(222/222/183) 1000/1000/800(278/278/222) 1500/1500/1200(417/417/333) 2000/2000/1600(556/556/444)
External Static Pressure SH/H/L Pa(in.wg) -/-/- -/-/- -/-/- 170/88/40(0.68/0.35/0.16) 150/60/28(0.60/0.24/0.11) External Static Pressure SH/H/L Pa(in.wg) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24)
Temperature Exchange Efficiency SH/H/L % -/-/- -/-/- -/-/- -/-/- -/-/- Temperature Exchange Efficiency SH/H/L % -/-/- -/-/- -/-/- -/-/-

LG Air Conditioners System


Enthalpy Exchange Efficiency Heating(SH/H/L) % -/-/- -/-/- -/-/- -/-/- -/-/- Enthalpy Exchange Efficiency Heating(SH/H/L) % -/-/- -/-/- -/-/- -/-/-
Cooling(SH/H/L) % -/-/- -/-/- -/-/- -/-/- -/-/- Cooling(SH/H/L) % -/-/- -/-/- -/-/- -/-/-
Noise Level(Sound Level, 1.5m) SH/H/L dBA -/-/- -/-/- -/-/- 33/28/23 34/32/25 Noise Level(Sound Level, 1.5m) SH/H/L dBA 36/34/30 37/35/31 37/35/31 37/35/31
Heat Exchanger Type - Crossflow Crossflow Crossflow Crossflow Crossflow Heat Exchanger Type - Crossflow Crossflow Crossflow Crossflow
Weight kg(lb) 24(52.91) 24(52.91) 27(59.51) 45(99.20) 52(114.7) Weight kg(lb) 67(147.7) 67(147.7) 146(321.9) 146(321.9)
Dimension WxHxD mm(inch) 590x204x590(23.23x8.03x23.23) 590x204x590(23.23x8.03x23.23) 596x320x640(23.46x12.60x25.20) 988x273x1014(38.9x10.75x39.92) 988x273x1014(38.9x10.75x39.92) Dimension WxHxD mm(inch) 1062x365x1140 (41.9x14.4x44.9) 1062x365x1140 (41.9x14.4x44.9) 1313x737x1140(51.7x28.8x44.9) 1313x737x1140(51.7x28.8x44.9)

Duct work Qty EA 4 4 4 4 4 Duct work Qty EA 4 4 4+2 4+2

70_71
Size(Ø) mm(inch) Ø100(Ø3.94) Ø100(Ø3.94) Ø150(Ø5.91) Ø200(Ø7.87) Ø200(Ø7.87) Size(Ø) mm(inch) Ø250(Ø9.54) Ø250(Ø9.54) Ø250(Ø9.54)+Ø350(Ø13.77) Ø250(Ø9.54)+Ø350(Ø13.77)
Supply Air Fan Qty EA 1 1 1 1 1 Supply Air Fan Qty EA 1 1 2 2
Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive Direct-Drive Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive
Exhaust Air Fan Qty EA 1 1 1 1 1 Exhaust Air Fan Qty EA 1 1 2 2
Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive Direct-Drive Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive
Filters Qty EA 2 2 2 2 2 Filters Qty EA 2 2 4 4
Type - Cleanable Cleanable Cleanable Cleanable Cleanable Type - Cleanable Cleanable Cleanable Cleanable
Size(WxHxD) mm(inch) 580x10x113(22.83x0.39x4.45) 580x10x113(22.83x0.39x4.45) 580x10x175(23.23x0.39x6.89) 855x10x166(33.66x0.39x6.54) 855x10x166(33.66x0.39x6.54) Size(WxHxD) mm(inch) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37)

Notes: Notes:
1. eco mode - Enthalpy Heat Recovery Ventilation mode 1. eco mode - Enthalpy Heat Recovery Ventilation mode
2. Noise level : 2. Noise level :
- The operating conditions are assumed to be standard. - The operating conditions are assumed to be standard.
- Sound measured at 1.5m below the center the body. - Sound measured at 1.5m below the center the body.
- Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
& Accessory
(LG Network Solution)

V-net Line up

Remote Wireless Remote


Controller Controller PQWRHDF0

Wired Remote
Controller Simple PQRCUCSOC
PQRCFCSOC

Standard PQRCUSA1

& Accessory
PQRCUDS0 (White)
Deluxe PQRCUDS0B (Blue)
PQRCUDS0S (Silver)

Central Simple Central PQCSB101S0

LG Air Conditioners System


Controller
Controller PQCSB101S0+PQCSC101S0
PQCSB101S0+PQCSD130A0
(Function controller) (Scheduler)

AC Smart &
PQCSW320A0E
128 Unit Expansion Kit
PQCSE440U0

72_73
ACP&AC Manager
PQCPA11A0E(Without IO)
PQCPB11A0E(With IO)
PQCSS520A0E(AC Manager)

BNU
PQNFB16A1 PQNFB17B0
( ) (BACnet)

V- n e t & A c c e s s o r y
PDI, Remote temperature sensor, Dry contact, Cool/Heat selector, DO Kit
74 Remote Controller Accessory Ventilation Kit (4Way Cassette), AHU Control kit & EEV kit, Refrigerant Charging Kit
Air guide, Suction grille and canvas, Heat recovery unit, Header, Y branch
76 Central Controller

84 Accessory
Remote Controller Remote Controller
•Wired Remote Controller
Our air conditioning system can be controlled by various types of
remote controllers providing general control to unique function. •Simple Wired Remote Controller
•Wireless Remote Controller

* Wired Remote Controller for Air-conditioner * Simple Wired Remote Controller

Standard (WIDE) Simple


Features PQRCUSA1
Features PQRCUCSOC
Operating mode On_Off / Fan speed / Mode / Temp.
On / Off LED √ Operating mode On_Off / Fan speed / Mode / Temp.
Room temp. √ Mode change Cooling / Heating / Fan
Fan / Plasma / Swirl / Heater √ Room temp √
Vane control / Auto swing / Fan auto √ Plasma √
E.S.P function √ Auto swing √
Reservation Weekly / Simple Child lock √
Timer function √
Child lock √ PQRCUCSOC
Electric failure compensation Max. 2 hours

& Accessory
PQRCUSA1 Wireless remocon receiver √
Master setting of indoor units
ΔT setting (For Auto Changeover) MULTI V SYNC II
2 Controllers to 1 indoor units
Simple for Hotel
: Applicable for only MULTI V II SERIES

Features PQRCFCSOC

Operating mode On_Off / Fan speed / Temp.


Deluxe Mode change Impossible
Room temp √

LG Air Conditioners System


Features PQRCUDS0, PQRCUDS0B, PQRCUDS0S
Plasma √
Operating mode On_Off / Fan speed / Mode / Temp. Auto swing √
Touch screen / LCD bak_light √
Room temp. √ PQRCFCSOC Child lock √
Fan / Plasma / Swirl / Heater √
Vane control / Auto swing √
E.S.P function √
Reservation Weekly / Simple
PQRCUDS0 (White) Timer function √

74_75
PQRCUDS0B (Blue) Child lock √
PQRCUDS0S (Silver) * Wireless Remote Controller

Features PQWRHDF0
* Wired Remote Controller for Operating mode On_Off / Fan speed / Mode / Temp.
Room temperature checking √
Standard Chaos swing / Jet cool √
On_Off timer √
Features PZRCUSB0 Sleep mode auto √
On / Off LED √ Main / Sub setting of indoor units
Ventilation mode setting √ ΔT setting (for Auto Changeover) MULTI V SYNC II
Rapid ventilation √
: Applicable for only MULTI V II SERIES
Power saving ventilation √
Reservation Weekly / Simple
Electric failure compensation Max. 2 hours PQWRHDF0
Child lock √
Plasma / Heater / Humidifier
Optional function
PZRCUSB0 Operating air volume
Simple Central Controller AC Smart & 128 Unit Expansion Kit
• A central controller for managing small sites For the mid sized buildings up to 64 or 128 indoor units
• Control up to 16 indoor units can be controlled and monitored by touch screen central
controller. It’s possible to control and monitor the air
PQCSW320A0E conditioning system through web access, anywhere with
computer.
PQCSE440U0
PQCSB101S0

Features PQCSB101S0
Max. no of indoor units 16 indoor units
Individual control On_Off Control
Lock function Total / Individual
Mode change Cooling / Heating
Malfunction indicator LED lamp
Dimension(mm) 120 x 120 x 20
Power(V) DC 10V

& Accessory
Function Controller & Scheduler
It is possible to control, monitor and schedule the *128 Indoor unit Expansion Kit: PQCSE440U0
*DO Kit : PQNFP00T0
operation of indoor units by using these controller
in company with a simple central controller

LG Air Conditioners System


• Combination
PQCSB101S0 PQCSB101S0
MULTI V PLUS II
PQCSC101S0 PQCSD130A0 MULTI V SYNC II
MULTI V SPACE II
RS485
MULTI V MINI
1.25mm2 X 2C
(shield)

PI485 AC220V MULTI V PLUS


Features PQCSB101S0+PQCSC101S0 PQCSB101S0+PQCSD130A0

76_77
MULTI V SYNC
MULTI V SPACE
DC Comm, Line
Max. no of indoor units 16 indoor units 16 indoor units AC Smart
PMNFP14A0 (Max. 16 Indoors)
Individual control On_Off / Fan speed / Mode / Temp. PQCSW320A0E
On_Off / Fan speed / Mode / Temp. PMNFP14A1 (Max. 48 Indoors)

Lock function Total / Individual Total / Individual Single A, MULTI


Mode change Cooling / Heating / Fan Cooling / Heating / Fan
Malfunction indicator Error display on LCD Error display on LCD
Schedule - Weekly PMNFP14A0

Dimension(mm) (120x120x20)+(70x120x14) (120x120x20)+(120x133x20)


Power(V) DC 10V DC 10V Single constant

* 1 Function controller combined with max. 8 simple central contollers.


PHNFP14A0 (Ceiling & Floor, Duct)
PSNFP14A0 (CST, RAC)

Eco-V

PHNFP14A0
Application
ACP (Advanced Control Platform)
• Through embedded web control function in ACP
one can control and monitor various functions of
air-conditioner such as temperature setting,
schedule, peak power control, etc.
PQCPA11A0E (Without IO)
PQCPB11A0E (With IO)

ACP&AC Manager
• AC Manager is suitable for large site because AC Manager
is the S/W that can control Max. 16 ACP (Max.4,096 indoor units).

PQCPA11A0E (Without IO) Application


PQCPB11A0E (With IO)
PQCSS520A0E (AC Manager)
Multi Area Management
The product specially designed for multi area management.
-Central control & monitor Max. 4,096 indoor units & Max.16 ACP

& Accessory
Max. 4,096 Indoor

Korean reference site. ACP AC Manager

LG Air Conditioners System


• Combination
RS485
1.25mm2 X 2C MULTI V PLUS II
(shield) MULTI V SYNC II
MULTI V SPACE II

78_79
MULTI V MINI

AC Manager
PQCSS520A0E PI485 AC220V MULTI V PLUS
LAN MULTI V SYNC
DC Comm, Line
• Features HUB
PMNFP14A0 (Max. 16 Indoors)
MULTI V SPACE

PMNFP14A1 (Max. 48 Indoors)

ACP ACP (without IO) + AC Manager ACP (with IO) + AC Manager


Single A, MULTI
PQCPA(B)11A0E PQCPA11A0E+PQCSS520A0E PQCPB11A0E+PQCSS520A0E
Max.no. of indoor units 256 indoor units 4,096 indoor units(16 ACP) 4,096 indoor units(16 ACP) PMNFP14A0
Internet
Control / Monitoring √ √ √
Schedule management Single constant
√ √ √
Lock function Temperature Mode/Temp/Fan speed/Schedule Mode/Temp/Fan speed/Schedule
Temperature range restriction - √ √ PHNFP14A0 (Ceiling & Floor, Duct)
PSNFP14A0 (CST, RAC)
Temperature limit function - √ √
Auto Changeover function - √ √
History function Monitoring Monitoring & Error history Monitoring & Error history
PI485 Eco-V
Peak control √ √ √
PDI monitoring Need of PDI Need of PDI Need of PDI
PHNFP14A0
Interlocking function - - Fire sensor, Door sensor, Motion sensor...
Printing function - System setting, History, PDI System setting, History, PDI
PDI (Power Distribution Indicator) DO Kit
• This device is an indicator for power consumption • Do Kit is connected between ACP (AC Smart) and
of the multi type air-conditioner used for common external devices. So ACP(AC Smart) can start and stop
power line. external devices such as light, pump, motor, etc.

PQNUD1S00 PQNFP00T0 AC Smart


• 7" Touch Screen / GUI
Easy Control Cooling
-Function Lock
• Direct Connect to LGAP -Lock Schedule Heating
Web Access
- Remote Management Comfort Control
• Combination
- Error Report via E-mail -Automatic H/C Changeover
• Features -Temperature Limit
-Temperature Range
- Accumulated total power consumption indicated Screen Saver Multi Language Restriction
- Accumulated / Current power consumption of each indoor units indicated -English, Italian, Spanish, -Time Limit Control
BUS _ A French, German, Dutch,
- Accumulated power consumption by month indicated RussianPower of Load
BUS _ B
- Max connectable no. of indoor units : 48 indoor units
- 1 PDI per 1 outdoor unit
DI RS485
- Power failure-proof function : Data back up on EEPROM even if power turns off
- Connectable to PC based central controller Light Pump Motor etc
ACP or AC Smart
- Simple connection with the remote metering system (RS485 approach) Easy Software DO Kit
USB
Upgrade by USB

& Accessory
L N

Operation Report
• Combination -Operating Time,
Percentage, History Emergency
LGAP
128 Indoor units
Expansion Kit
Digital WHM
(Local purchase) • Remote Controller Restriction
Emergency Interlock Multiple Local Controllers • Automatic Setting
AC220V -Forced Off -Master / Slave • A/C and Vent.

LG Air Conditioners System


Pulse output (1,2, 4,6,8,10W/pulse) PI485
AC 200V~240V 50/60Hz

PQNUD1S00 RS485

80_81
or

* In the case of MULTI V II SERIES, don’t need PI 485


BNU-LW Gateway BNU-BAC Gateway
(Building Network Unit- ) (Building Network Unit- BACnet)
Easy interface between BMS and LG air conditioner Easy interface between BMS and LG air conditioner
- Independence of BMS under the standard BMS - Independence of BMS under the standard BMS
: Operation system based on LNS ( network service) : Operation system based on BACnet Service.
- No network installation needed
PQNFB16A1 - Very widely applicable protocol( ) PQNFB17B0

• Features • Features
- Connection to using LONTALK Controlling Monitoring items - Through embedded web control function in BACnet Controlling Monitoring items
protocol and LG Air-conditioner protocol one can access the airconditioner and external On/Off command
On/Off command On/Off status report On/Off status report
- Process ability Operation mode setting Operation mode status report devices through internet. Operation mode setting Operation mode status report
• 64 units( including indoors and ventilators) Fan speed setting
Fan speed setting Fan speed status report - It can control 256 indoor units. ( A/C or Ventilator ) Fan speed status report
• Valid address for each unit : 0x00 ~ 0x3F
Lock setting Lock status report Lock setting Lock status report
- External devices such as fire alarm, motion
- Self installation verification function using internet Air flow setting Air flow status report Air flow setting Air flow status report
(Web server included) detector can be connected to gateway and their
Set temp. setting Set temp. status report Set temp. setting
• Setting gateway function can be interlinked with airconditioner
User mode setting (for only ventilator) Current space temp. status report User mode setting (for only ventilator) Current space temp. status report
• Diagnosis of communication status on operation.
LG Air-conditioner network Error status report Error status report

- Connection to remote total management system User mode status report User mode status report
(for only ventilator) (for only ventilator)
(LG system)

& Accessory
• Combination • Combination

BACnet

LG Air Conditioners System


Network Network
BMS system BMS system
BACnet comm. line
LON comm. line

Lighting control Remote checking Utility control


Lighting control Remote checking Utility control
Indoor unit : Max. 256 units (Air-conditioner & ventilation) Other BACnet devices

82_83
Indoor unit : Max. 64 units (Air-conditioner & ventilation) Other LON devices
Indoor address : 00 ~ 3F Indoor address : 00 ~ FF

MULTI V PLUS II MULTI V PLUS II


MULTI V SYNC II MULTI V SYNC II
MULTI V SPACE II MULTI V SPACE II
MULTI V MINI RS485 MULTI V MINI
RS485
1.25mm2 X 2C
1.25mm2 X 2C
(shield) PI485
(shield) MULTI V PLUS MULTI V PLUS
PI485 MULTI V SYNC MULTI V SYNC
MULTI V SPACE MULTI V SPACE
PMNFP14A0 (Max. 16 Indoors)
PMNFP14A1 (Max. 48 Indoors)
PMNFP14A0 (Max. 16 Indoors)
PMNFP14A1 (Max. 48 Indoors)
BNU-LW BNU-BAC
PI485
Single A, MULTI Single A, MULTI
PQNFB16A1 PI485 PQNFB17B0

PMNFP14A0
or PMNFP14A0
Eco-V
or PI485 Eco-V
PI485

PHNFP14A0
Simple central AC Smart PHNFP14A0 Simple central AC Smart Outdoor unit Indoor unit
Outdoor unit Indoor unit
controller controller LGAP applied Air-conditioner
LGAP applied Air-conditioner
Remote Temperature Sensor Cool/Heat Selector
It can help to detect the exact room temperature This switch enables selection of heating, cooling
at the optimal position. or fan mode. So it can prevent that cooling & heating
• Model applied to Cassette, Duct type. mixing error occurs during the change of season.
• Part supplied
- Remote temperature sensor
PQRSTA0 - Cable (15m) - Manual PRDSBM

• Features
- Indoor unit control without central controller
• Wiring diagram
Extension cable Connector - Select operation mode : Cooling, Heating, Fan mode
1. Wire to the control box in the indoor unit by - Mode lock for cooling & heating mixing error-proof during the change of season.
removing the existing thermistor and connect
the extension cable its place. Screw terminal
connection • Combination
2. Cut the extension cable to the appropriate Fan Mode
Mode Change
length and connect the screw terminal of the Indoor unit
remote sensor. Cooling Heating
3. In the case of wired remote controller installed,
set the temperature sensing slide s/w at MAIN mode.

Remote
temperature sensor

& Accessory
* PRDSBM is applicable for only MULTI V II Series.
Dry Contact module
• It is connected between indoor units and external
device, so it can be used for various purpose.
Ventilation Kit (4Way Cassette)
Fresh air can be supplied from outside through this

LG Air Conditioners System


ventilation kit.
PQDSB(A) / PQDSB1 / PQDSBC PTVK410 PTVK420 PTVK430

• Accessory • Dimension
• Features

84_85
PQDSA(B) PQDSB1 PQDSBC • Installation Bracket
• Bolt
Contact point 1 contact point 1 contact point 2 contact points • Screw
Power input AC 220V from outside AC 24V from DC 5V&12V from
power source outside power source indoor unit PCB
Voltage / Non voltage input √
On_Off control √ √ √
Lock / Unlock √
Fan speed setting √
Thermo off √
Energy saving √
• Models applied to
Expected temperature setting √
• Ceiling Cassette - 4Way (24k ~ 48k Btu/h)
Error Monitoring √ √ √
Operation monitoring √ √ √

* PQDSBC is applicable for only MULTI V II Series.


AHU Control Kit & EEV Kit Refrigerant Charging Kit
Fresh air can be supplied from outside connecting
AHU to Multi V Plus II.

PRCKA0 PRLK048A0 PRAC1

• Specifications • Procedure
1. Arrange manifold, refrigerant charging kit, refrigerant vessel and scale
Weight(kg) Dimension(mm) 2. Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure.
Model Name POWER 3. Connect manifold refrigerant charging kit. Use designated refrigerant charging kit.
NET Gross W H D
If designated refrigerant charging kit isn’t used, the system may get damaged.
Control Kit PRCKA0 2.23 3.6 280 135 280
EEV Kit PRLK048A0 3.1 3.6 404.2 83 217
220~240V / 50HZ / 1Pha 4. Connect refrigerant charging kit and refrigerant vessel.
5. Purge hose and manifold.
6. After “568” is displayed, open the valve and charge the refrigerant

• Selection of evaporator
 hen selecting evaporator, Change ‘Option PCB’ in EEV kit according to below table
W
(Basic ‘Option PCB is for 36k Btu/h ) • Application • Dimension

& Accessory
Capacity Allowed heat exchanger Allowed heat exchanger
Option PCB P/No Detail
(Btu/h) Volume (dm3/hr) capacity (kW)
Manifold 202
133
EBR52358907 28k 1.22~1.53 7~9
EBR52358908 36k 1.53~1.91 9~11
(Main PCB) Capacity setting
EBR52358909 42k 1.91~2.14 11~13 'Option PCB'
Refrigerant Charging Kit
EBR52358910 48k 2.14~2.67 13~16 (PRAC1)
EBR52358911 76k 3.06~3.82 20~24
EBR52358912 96k 3.82~4.78 25~31

LG Air Conditioners System


* Saturated Suction Temperature (SST) = 6ºC, SH (Superheat)=5k, Air Temperature = 27ºC DB / 19ºC WB

69
Refrigerant
• Wiring diagram
Single

86_87
Pipe

Themistor Return Air

• Error contents about auto refrigerant charging function


1. “329”: Temperature range error (In case that indoor unit or outdoor unit is out of range)
Supply Air 2. “339”: Low pressure descent error (In case the system runs at low pressure limit for
over 10 minutes)
3. “349”: Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using
designated refrigerant charging kit)
4. “359”: Instability error (In case the high/low pressure target doesn’t get satisfied for some
time after the starting operation)
Air Guide Heat recovery unit
(Applied to MULTI V SYNC II R410A)
• Used to control the direction of air discharge
PRHR020
by outdoor unit. (2 Pipe-connection) • Max. 4 indoor units can be connected by module design.
• Converts vertical discharge into horizontal discharge. • Due to the automatic search algorithm for piping
detection, easy installation and effectiveness is improved.
• Subcooling cycle in HR unit makes the system
PQAGA
efficiency maximum.
PRHR030 PRHR040
(3 Pipe-connection) (4 Pipe-connection)
• Application • Dimension

• Combination

Outdoor unit

Indoor unit

Suction Grille and Canvas • Specifications

& Accessory
PRHR020 PRHR030 PRHR040
• High flexibility for a wide variety of applications
Max. connectable number of indoor units 2 3 4
PBSGB30 / PBSGB40 Max. connectable capacity of indoor units (Per port/unit) kW 14.1 / 47
PBSC30 / PBSC40 Nominal Input cooling W 26 40 40
heating W 26 40 40
• Features Net weight kg 19 20 21

LG Air Conditioners System


Dimensions (WxHxD) mm 801x218x617 801x218x617 801x218x617
- High external static pressure facilitates unit use with flexible ducts of varying lengths.
Piping Indoor liquid mm(inch) 9.52(3/8)
- When using suction panel, unit requires only 270mm of ceiling space.
- Blends unobtrusively with any interior decoration. connections unit gas mm(inch) 15.88(5/8)
Outdoor liquid mm(inch) 9.52(3/8) 12.7(1/2) 12.7(1/2)
• Models applied to unit low pressure mm(inch) 19.05(3/4) 28.58(1 1/8) 28.58(1 1/8)
- Ceiling concealed duct _ Built-in type high Pressure mm(inch) 19.05(3/4) 22.2(7/8) 22.2(7/8)
Power supply Ø/V/Hz

88_89
Capacity (Btu/h) 1/220 ~ 240/50
Type Model 7k 9k 12k 15k 18k 24k
PBSGB30 √ √ √ √
Grille
PBSGB40 √ √
PBSC30 √ √ √ √
Canvas
PBSC40 √ √

• Dimension
C
C

A A
B B

A B C A B C
PBSGB30 910 359 56 PBSC30 821 274 42~250
PBSGB40 1188 359 56 PBSC40 1100 274 42~250
Header for connection of indoor units Y Branch pipe for connection of indoor units
If you need a highly efficient air condition-
* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II * MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II
ing system in your building, MULTI V is the right
(unit:mm) (unit:mm) (unit:mm) (unit:mm)
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
choice for you.
Model Model Gas Pipe Liquid Pipe Model Model Gas Pipe Liquid Pipe

4 branch 7 branch
ARBL054 ARBL107
ARBLN01621 ARBLN07121

NEO Plasma
7 branch 10 branch Air Purifying
ARBL057 ARBL1010 System Auto Clean

ARBLN03321 ARBLN14521
4 branch 10 branch
ARBL104 ARBL2010
Sleep Mode
Jet Cool Auto Operation

* MULTI V SYNC II
Y Branch pipe for connection of outdoor units (unit:mm) Healthy
Dehumidification Auto Restart
Model Low Pressure Gas Pipe Liquid Pipe High Pressure Gas Pipe

* MULTI V PLUS II (2 Outdoor units) * MULTI V PLUS II (3 Outdoor units)

& Accessory
(unit:mm) (unit:mm)
ARBLB01621 Hot Start 4-Way
Model Connection of Gas Pipe Connection of Liquid Pipe Model Connection of Gas Pipe Connection of Liquid Pipe
(Heat pump only) Air Deflection

ARCNN20
Child Lock
Function
ARCNN20
ARBLB03321
( Wired
controller only )
remote Swirl Swing

LG Air Conditioners System


ARCNN30 Weekly
Program
Soft Dry
Operation Mode ( Wired
controller only)
remote

ARBLB07121

90_91
Two Thermistor
* MULTI V SYNC II (2 Outdoor units) * MULTI V SYNC II (3 Outdoor units)
Control

Low Pressure Liquid Pipe


(unit:mm)
High Pressure Model Low Pressure Liquid Pipe
(unit:mm)
High Pressure
Low Standby
Power ( Wired
controller only)
remote

Model
Gas Pipe Gas Pipe Gas Pipe Gas Pipe

ARBLB14521 Group Control


ARCNB20 Changable
( Wired
controller only)
remote
Panel
ARCNB20

Auto Changeover
ARCNB30
( MULTI
model only )
V SYNC Second
Remote Control