Outdoor Unit
10 16
20
MULTI V MINI
MULTI V PLUS II
28 MULTI V SYNC II
2009
34 MULTI V SPACE II
Indoor Unit
Air Conditioning System
38
49
50
Wall Mounted
ARTCOOL
2009
52 Ceiling Cassette
56 Ceiling Concealed Duct
60 Ceiling & Floor
61 Ceiling Suspended Air Conditioning System
62 Floor Standing
Heat Recovery
Ventilator
64 66
67
Features
Installation & Maintenance
68 Line-up
70 Specifications
Network Solution
& Accessory & Accessory Distributed by
72
74
http://www.lgeaircon.com
Remote Controller
76 Central Controller Air Conditioner
84 20 Yeouido-dong, Yeongdeungpo-gu,
Accessory
Yeouido P.O.Box 335 Seoul, 150-721, Korea.
Phone : +82-2-3777 -7998
Fax : +82-2-3777- 5136
http://www.lgeaircon.com
EU-MV091
2009
Life’s Good!
From installation to maintenance and repair,
LG runs 30 global air conditioning academies, providing
training for air conditioning professionals around the world.
B r i e f H i sto r y
Establishment
1947 Establishment of the LG Group
1958 Establishment of LG Electronics Inc.
1962 Establishment of Digital Appliance Company
Growth
1968 Manufactured Korea’s first air conditioners
1985 Introduced Korea’s first Inverter air conditioners
1986 Exported Korea’s first window type air conditioner
Expansion
1995 Establishment of LGE TA in China
1997 Establishment of LG E I L in India
1999 Establishment of LG E AT in Turkey
1999 Establishment of LG E V N in Vietnam
2001 Establishment of LG E A Z in Brazil
2002 Establishment of LG E T H in Thailand
2002 Establishment of LG E I N in Indonesia
2004 Turnover of US$1 .4 Billion dollars
2008 Establishment of LGELF in Levant Countries
2008 Establishment of LGETK in Turkey
Changwon in Korea Pyeongtaek in Korea Thailand England France Australia Moscow Singapore
Spain Italy Dubai China Saudi Arabia Mexico Panama Indonesia Iran Turkey Vietnam
Multi V Series
Your life comes more quiet, economical and powerful
Outdoor
with LG air conditioning high technology. Unit 16 MULTI V MINI
10 20
28
MULTI
MULTI
V PLUS II
V SYNC II
34 MULTI V SPACE II
Environment
Economic
38 50
52
ARTCOOL
Ceiling Cassette
56 Ceiling Concealed Duct
60 Ceiling & Floor
61 Ceiling Suspended
62 Floor Standing
eco V
(Heat Recovery
66 Features
Ventilator)
67 Installation & Maintenance
68 Line-up
64 70 Specifications
V-net
& 74 Remote Controller
Accessory 76 Central Controller
84 Accessory
72
Outdoor unit line up
MODEL HP 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64
kW 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.2 10.6 12.3 14.1 22.4 28.0
Btu / h 5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k
Series
Mirror
4way Cassette
4way Cassette
(840*840)
Ceiling
Cassette
2way Cassette
1way Cassette
08_09
High Static
Ceiling Suspended
With Case
Floor
Standing
Without Case
Outdoor unit
MULTI V Inverter units composed of serially arranged
refrigerant pipes connected to a single outdoor unit are
an efficient system that offers outstanding energy saving,
simple and easy installation, and connection to different
types of indoor units, making it easy to design and install.
16 MULTI V MINI
20 MULTI V PLUS II
28 MULTI V SYNC II
34 MULTI V SPACE II
Outdoor unit 2009 New Features
Pursuing the market needs of high energy MULTI V MINI / MULTI V PLUS II
efficiency and environmental friendliness. MULTI V SYNC II / MULTI V SPACE II
12_13
01 01 Optimized scroll shape 04 Upgraded Main PCB
02 02 Oil injection mechanism - 3-Digit 7 segment
- High reliability in low rpm operation
- High efficiency in partial load operation Wide Louver heat exchanger 3Ø INV controller - Double DIP switch
03
03 Oil discharge reduction
05 - High reliability in high rpm operation Main PCB
04 Corrugate fin
- Enhanced oil circulation
06 04 DC Inverter motor
- High efficiency - Low noise
14_15
Refrigerant
46%
730mm
330
mm
Reduction
16_17
950mm
806mm
• Volume
52%
Reduction
*Based on 6 HP model
18_19
02 03 Air flow rate [CMM] 110 110 110 110 110 110
Compressor Type DC INVERTER DC INVERTER
Number of compressors 1 1 1 1 1 1
02 Convenient moving handle Heat Exchanger Gold Fin Gold Fin
Refrigerant Type R410A R410A
03 Compact design & Easy service Charge kg 3.7 3.7 3.7 3.7 3.7 3.7
- Remove 3 pieces of screw for SVC Control EEV EEV
Refrigerant Type FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE] FV50S[PVE]
- Front panel removal system
Oil Charge l 1.7 1.7 1.7 1.3 1.3 1.3
Piping Liquid Pipes mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Connections Gas Pipes mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4) Ø15.88(5/8) Ø15.88(5/8) Ø19.05(3/4)
Number of outdoor unit 1 1 1 1 1 1
Number of maximum connectable indoor units 6 8 9 6 8 9
Ratio of the connectable indoor units 50~130% 50~130%
Longest piping length / Level difference 150m/50m 150m/50m
3 pieces of screw
Note :
1. Capacities are based on the following conditions
Easy service Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Level difference of zero Level difference of zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV : Electronic Expansion Valve
MULTI V Inverter system offers one of the world’s
TECHNOLOGY
Your life will be upgraded through the
largest capacity units, essential for high-rise buildings. state-of-the-art technology of MULTI V PLUS II.
We are proud to say the system will ensure the highest
level of customer satisfaction.
Low Noise
• Latest technology and features are
applied to the new outdoor units to
reduce noise level.
*Based on
10HP model
60
Gernerally lower noise!!
55
HP
20_21
50
5 10 20 30 40
LG Competitor
Alternate-Cycling Function
• To extend compressors’ life span by
operating them alternately
Inverter A <> Inverter B <> Inverter C
ON ON ON ON ON Constant A <> Constant B <> Constant C
Failed!
22_23
Cool / Heat Selector
Auto addressing Fan Mode
mode change • Control all units without any central
Indoor unit Indoor unit Indoor unit Addressing outdoor units and indoor controller installed
Cooling Heating
units are automatically done just by
• Select operation mode
pressing the button.
(Air circulation, cooling, heating)
• Mode lock for heating & cooling
mixing error-proof during the
Wired remote Wired remote Wired remote change of season
control control control
‘09 New Feature
MULTI V Inverter system offers one of the world’s • DC Inverter Compressor & Fan motor
largest capacity units, essential for high-rise buildings. • Black Box Function
• Night Silent Operation
We are proud to say the system will ensure the highest
• Fault Detect & Diagnosis
level of customer satisfaction.
• Pump Down & Pump Out
24_25
3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm 806×1607×730 806×1607×730 1280×1607×730 1280×1607×730 1280×1607×730 1280×1607×730 1280×1607×730
Weight kg 175 175 240 285 285 285 285
Color Warm Gray
Noise level dBA±3 56 56 58 58 58 58 58
Fan Type Propeller Fan (DC INV)
Air flow rate [CMM] 105 105 190 190 190 190 190
Compressor Type DC Inverter Scroll DC Inverter Scroll / Constant speed Scroll
Number of compressors 1 1 1 2 2 2 2
Heat Exchanger Gold fin
Refrigerant Type R410A
Charge kg 4.5 4.5 8 8 8 8 8
Control EEV
Refrigerant Type FVC68D(PVE)
Oil Charge l 2.3 2.3 3.3 5.6 5.6 5.6 5.6
Piping Liquid Pipes mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Connections Gas Pipes mm(inch) Ø15.88(5/8) Ø19.05(3/4) Ø19.05(3/4) Ø22.2(7/8) Ø28.58(1 1/8) Ø28.58(1 1/8) Ø28.58(1 1/8)
Number of outdoor unit 1 1 1 1 1 1 1
Number of maximum connectable indoor units * 8(12) 9(14) 13(20) 16(25) 19(30) 23(35) 26(40)
Ratio of the connectable indoor units 50~200%
Longest piping length / Level difference ** 200m/100m
Check up the note, refer to on the 27 page.
MULTI V PLUS II ensures economic life with high energy efficiency!!
* Specifications * Specifications
HP 18 20 22 24 26 28 30 32 HP 50 52 54 56 58 60 62 64
Model Combination unit ARUN180LT2 ARUN200LT2 ARUN220LT2 ARUN240LT2 ARUN260LT2 ARUN280LT2 ARUN300LT2 ARUN320LT2 Model Combination unit ARUN500LT2 ARUN520LT2 ARUN540LT2 ARUN560LT2 ARUN580LT2 ARUN600LT2 ARUN620LT2 ARUN640LT2
Independent unit ARUN120LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 Independent unit ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
ARUN60LT2 ARUN60LT2 ARUN60LT2 ARUN80LT2 ARUN120LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
ARUN140LT2 ARUN140LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
Capacity Cooling kW 50.4 56.0 61.6 67.2 72.8 78.4 84.0 89.6 ARUN80LT2 ARUN80LT2 ARUN80LT2 ARUN80LT2 ARUN100LT2 ARUN120LT2 ARUN140LT2 ARUN160LT2
Heating kW 56.7 63.0 69.3 75.6 81.9 88.2 94.5 100.8 Capacity Cooling kW 140 145.6 151.2 156.8 162.4 168 173.6 179.2
Power Cooling kW 13.33 16.10 18.25 19.28 20.93 23.70 25.85 28.00 Heating kW 157.5 163.8 170.1 176.4 182.7 189 195.3 201.6
Input Heating kW 13.60 15.15 16.95 18.13 19.65 21.20 23.00 24.80 Power Cooling kW 40.83 42.98 45.13 47.28 49.16 51.08 53.85 56.00
COP Cooling 3.78 3.48 3.38 3.49 3.48 3.31 3.25 3.20 Input Heating kW 37.53 39.33 41.13 42.93 44.53 46.25 47.80 49.60
Heating 4.17 4.16 4.09 4.17 4.17 4.16 4.11 4.06 COP Cooling 3.43 3.39 3.35 3.32 3.30 3.29 3.22 3.20
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 Heating 4.20 4.16 4.14 4.11 4.10 4.09 4.09 4.06
Dimensions(WxHxD) mm (1280×1607×730) (1280×1607×730) (1280×1607×730) (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
+(806×1607×730) +(806×1607×730) +(806×1607×730) Dimensions(WxHxD) mm (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4 (1280x1607x730)x4
Weight kg 285+175 285+175 285+175 285+240 285x2 285x2 285x2 285x2 Weight kg 285X3+240 285X3+240 285X3+240 285X3+240 285x4 285x4 285x4 285x4
Color Warm Gray Color Warm Gray
Noise level dBA±3 60 60 60 61 61 61 61 61 Noise level dBA±3 64 64 64 64 64 64 64 64
Fan Type Propeller Fan(DC INV) Fan Type Propeller Fan(DC INV)
Air flow rate [CMM] 295 295 295 380 380 380 380 380 Air flow rate [CMM] 760 760 760 760 760 760 760 760
Compressor Type DC Inverter Scroll / Constant speed Scroll Compressor Type DC Inverter Scroll / Constant speed Scroll
Number of compressors 3 3 3 3 4 4 4 4 Number of compressors 7 7 7 7 8 8 8 8
Heat Exchanger Gold fin Heat Exchanger Gold fin
* The number of () means the number of max. connectable indoor units, when the connected capacity of
indoor units is in the table below.
** Conditional Application
HP 34 36 38 40 42 44 46 48 To make 40~90m of pipe length after first branch refer to the part of “installation of outdoor units” in PDB
Model Combination unit ARUN340LT2 ARUN360LT2 ARUN380LT2 ARUN400LT2 ARUN420LT2 ARUN440LT2 ARUN460LT2 ARUN480LT2 Note :
Independent unit ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2 ARUN140LT2 ARUN160LT2 ARUN160LT2 ARUN160LT2
26_27
(1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×2 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3 (1280×1607×730)×3
CAUTION
+(806×1607×730) +(806×1607×730) +(806×1607×730)
• A combination operation over 100% cause to reduce each indoor unit capacity
Weight kg 285x2+175 285x2+175 285x2+175 285x2+240 285×3 285×3 285×3 285×3
Color • Combination ratio(50~200%)
Warm Gray
Noise level dBA±3 62 62 62 63 63 63 63 63 No. of outdoor unit Connection Capacity
Fan Type Propeller Fan(DC INV) Single unit 200%
Air flow rate [CMM] 485 485 485 570 570 570 570 570 Double unit 160%
Compressor Type DC Inverter Scroll / Constant speed Scroll Triple unit 130%
Number of compressors 5 5 5 5 6 6 6 6 Over triple unit 130%
Coefficient of Performance(COP)
40
28_29
AMC control provides an optimal cycle
operation under any conditions.
Optimum area
- Real time pressure control
- Optimal cycle in optimum area
- Needed time to change mode : Max. 3min
Cooling
Wide Operation Range
Wide operation range
- Heating mode : - 20°C WB ~ 16°C WB
Synchronous
Operation area - Cooling mode : - 5°C DB ~ 43°C DB
- Synchronous mode : -10°C DB ~ 27°C DB
Enjoy a clean &
comfortable life with MULTI V.
Heating
Simultaneous heating and cooling with one outdoor
COMFORT
MULTI V SYNC II ensures the comfort of all users
unit, MULTI V SYNC II. Your environment is ensured of with flexible design and easy installation.
optimum conditions regardless of season or space.
• Double spiral tube heat exchanger High Efficiency Heat • MULTI V SYNC II Fast Response of Mode
Recovery Unit Change
Linear Heating Cooling
From outdoor
expansion valve • High efficient double spiral tube When the user wants to change the indoor
type SCI circuit unit’s operating mode (ex. cooling > heating),
MULTI V SYNC II takes less time compared
To indoor • Maximum 4 indoor units connectable Max. 3minutes to the conventional. This fast response of
2 phase fluid
per one HR unit mode change provides a more pleasant and
About 20minutes
30_31
Impossible In series only
20m
Y Branch
Time
Same mode operation
in the different zones
MULTI V SYNC II simultaneous heating and cooling from a single outdoor unit!
‘09 New Feature
• DC Inverter Compressor & Fan motor
• Black Box Function
* Specifications
• Night Silent Operation HP 22 24 26 28 30 32 34
Model Combination unit ARUB220LT2 ARUB240LT2 ARUB260LT2 ARUB280LT2 ARUB300LT2 ARUB320LT2 ARUB340LT2
• Fault Detect & Diagnosis Independent unit ARUB140LT2 ARUB160LT2 ARUB140LT2 ARUB140LT2 ARUB160LT2 ARUB160LT2 ARUB140LT2
• Pump Down & Pump Out ARUB80LT2 ARUB80LT2 ARUB120LT2 ARUB140LT2 ARUB140LT2 ARUB160LT2 ARUB120LT2
ARUB80LT2
Capacity Cooling kW 61.6 67.2 72.8 78.4 84.0 89.6 95.2
Heating kW 69.3 75.6 81.9 88.2 94.5 100.8 107.1
Power Cooling kW 17.13 19.28 20.93 23.70 25.85 28.00 26.21
Input Heating kW 16.33 18.13 19.65 21.20 23.00 24.80 25.38
COP Cooling 3.60 3.49 3.48 3.31 3.25 3.20 3.63
Heating 4.24 4.17 4.17 4.16 4.11 4.06 4.22
Power Supply Ø, V, Hz 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50 3, 380~415, 50
Dimensions(WxHxD) mm (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x2 (1280x1607x730)x3
Weight kg 240+285 240+285 285+285 285+285 285+285 285+285 240+285+285
Color Warm Gray
Noise level dBA±3 61 61 61 61 61 61 63
Fan Type Propeller Fan(DC INV)
Air flow rate [CMM]
* Specifications Compressor Type
380 380 380 380 380
DC Inverter Scroll / Constant speed Scroll
380 570
HP 8 10 12 14 16 18 20 Number of compressors 3 3 4 4 4 4 5
Model Combination unit ARUB80LT2 ARUB100LT2 ARUB120LT2 ARUB140LT2 ARUB160LT2 ARUB180LT2 ARUB200LT2 Heat Exchanger Gold fin
Independent unit ARUB80LT2 ARUB100LT2 ARUB120LT2 ARUB140LT2 ARUB160LT2 ARUB100LT2 ARUB120LT2 Refrigerant Type R410A
32_33
(1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3 (1280x1607x730)x3
Number of maximum connectable indoor units * 13(20) 16(25) 19(30) 23(35) 26(40) 29(36) 32(40) Weight kg 240+285+285 240+285+285 240+285+285 285+285+285 285+285+285 285+285+285 285+285+285
Ratio of the connectable indoor units 50~200% 50~160% Color Warm Gray
Longest piping length / Level difference ** 200m/100m Noise level dBA±3 63 63 63 63 63 63 63
Fan Type Propeller Fan(DC INV)
* The number of () means the number of max. connectable indoor units, when the connected capacity of indoor units is in the table below.
Air flow rate [CMM] 570 570 570 570 570 570 570
** Conditional Application
To make 40~90m of pipe length after first branch refer to the part of “installation of outdoor units” in PDB Compressor Type DC Inverter Scroll / Constant speed Scroll
Number of compressors 5 5 5 6 6 6 6
Note :
Heat Exchanger Gold fin
1. Capacities are based on the following conditions
Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Refrigerant Type R410A
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Charge kg 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8 8+8+8
Interconnecting piping length 7.5m Interconnecting piping length 7.5m Control EEV
Level difference of zero Level difference of zero Refrigerant Type FVC68D(PVE)
2. Capacities are net capacities Oil Charge l 5.6+5.6+3.3 5.6+5.6+3.3 5.6+5.6+3.3 5.6+5.6+5.6 5.6+5.6+5.6 5.6+5.6+5.6 5.6+5.6+5.6
3. Due to our policy of innovation some specifications may be changed without notification Piping Liquid(flare) mm(inch) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4)
4. EEV : Electronic Expansion Valve
Connections Suction Gas mm(inch) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8) Ø41.3(1 5/8)
Discharge Gas mm(inch) Ø28.58(1 1/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8) Ø34.9(1 3/8)
CAUTION We can guarantee the operation only within 130% Combination.
If you want to connect more than 130% combination, please contact us and discuss the Number of outdoor unit 3 3 3 3 3 3 3
• A combination operation over 100% cause to reduce each indoor unit capacity requirement like below. Number of maximum connectable indoor units 58 61 64 64 64 64 64
• Combination ratio(50~200%)
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended Ratio of the connectable indoor units 50~130%
No. of outdoor unit Connection Capacity in all the indoor units.
Single unit 200% 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according Longest piping length / Level difference ** 200m/100m
Double unit 160% to the headquarter guidance.
Triple unit 130% 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
Economic and aesthetic space design MULTI V
COMFORT & SILENCE
The concept of the balcony is changed with
SPACE II is ideal for refined and luxurious living the outdoor unit that does not generate hot air.
spaces. Low noise and vibration technology of MULTI V
SPACE II ensures a quiet environment.
No efficiency reduction!
34_35
• LG patents : 57items LG Patent For MULTI V SPACE II
01 All technologies in the MULTI V SPACE II
which make it a distinctive, unique unit
02 have been applied for patents domestically
and internationally. and, some of them
03
have already been registered.
04
01 Whole structure (8 items)
How to set up
- E.S.P control
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Step 1 >4mmAq < ESP < 6mmAq
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Step 2 >6mmAq < ESP < 8mmAq
* Specifications
1 2 3 4 5 6 7 8 9 10 11 12 13 14 HP 6 8
Step 3 >8mmAq < ESP < 10mmAq Model Independent unit ARUN60LR2 (Right Discharge) ARUN80LR2 (Right Discharge)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
ARUN60LL2 (Left Discharge) ARUN80LL2 (Left Discharge)
Step 4 >10mmAq < ESP < 12mmAq Capacity Cooling kW 16.0 21.7
Heating kW 18.0 23.0
Power Cooling kW 4.7 6.7
- Noise control
Input Heating kW 4.9 6.7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Low blowing noise COP Cooling kW 3.40 3.24
> Max - 100 rpm Heating kW 3.67 3.43
36_37
• Outdoor unit can be installed Number of compressors 1 1
Heat Exchanger Gold Fin
according to overall building Refrigerant Type R410A
1steps 2steps 3steps 4steps construction schedule.
Louver frame System louver Mechanical parts Fan parts Charge kg 5.2 5.2
Control EEV
• Louver is provided locally Refrigerant Type FVC68D(PVE)
Oil Charge l 2.3 2.3
Piping Liquid(flare) mm(inch) 9.52(3/8) 9.52(3/8)
Connections Gas(Bazing) mm(inch) 19.05(3/4) 19.05(3/4)
Number of outdoor unit 1 1
Number of maximum connectable indoor units 9 13
Ratio of the connectable indoor units 50~130%
Longest piping length / Level difference 150m/50m
* Preliminary data (8HP model)
Note :
1. Capacities are based on the following conditions
Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB
Interconnecting piping length 7.5m Interconnecting piping length 7.5m
Level difference of zero Level difference of zero
2. Capacities are net capacities
*6HP (ARUN60LR2, ARUN60LL2) 3. Due to our policy of innovation some specifications may be changed without notification
*8HP (ARUN80LR2, ARUN80LL2) 4. EEV : Electronic Expansion Valve
Indoor unit
If you need a highly efficient air conditioning
system in your building, MULTI V is the right
choice for you.
Wall Mounted
Mirror
Indoor Unit
4Way Casstte
2Way Casstte
1Way Casstte
Low Static
High Static
38_39
Ceiling & Floor
M U LT I V
indoor
Ceiling Suspended
49 Wall mounted
50 ARTCOOL Floor Standing
52 Ceiling Cassette - With Case
62 Floor standing
LG has been able to create a design conscious indoor unit that • Aesthetic Design
compliments any interior decoration. And they have improved • Low Noise
air flow innovatively to realize world’s lowest noise, and provide • 4 Vane Independent Operation
a more pleasant and convenient indoor environment.
• Auto Elevation Grille
Indoor Unit
1 Vane, 1 Motor
Operation
Vane angle control satisfies both users
- How to change the picture who like direct wind and indirect wind.
and also it prevents cold air draft.
Direct air flow Indirect air flow
All vane operation Individual vane operation • Easy vane angle control with a remote controller
1 : 20 °
0 : 30 °
- Panel type
40_41
Easy filter cleaning with elevation grille
Silver 07/09/12GSFV2 Gold 07/09/12GSFG2 Red 07/09/12GSFE2 White silver 07/09/12GSFH2 4 Way
4.5m
- Installed inside main body
- Auto horizontal level
- 4 points support
Conventional
3.5m - Memory for user’s level
- Max. 4.5m length
- ARTCOOL Mirror
4-Point support structure Auto horizontal control Memory for user’s level Auto bottom detection
Max. 4.5m
18/24GS8R2 18/24GS8V2 18/24GS8B2
STOP
Memory
Highlander
Even air distribution
t
Temp.
Indoor Unit
26
25
27°C
24
23
22
21
20
19
18 Max. 9 discharging
15°C
15°C
42_43
Flexible Connection Linear E.S.P Control
Air volume and sound are always kept
Flexible connection of remote controller
as design regardless of E.S.P change
- Group control using this technology , you can
: 1 remote controller to several indoor units
• Optimize duct work Installation
- Second remote control • Keep capacity & sound level as desired
: 2 remote controllers to 1 indoor unit • Simplify model numbers
Easy & solid attachment to the wall The phase control motor technology
offers money saving benefit to the installer.
wall
wall
Indoor Unit
204mm 246mm PHDHA07B – 700mm 5EA
44_45
Refrigerant Drain leakage
Drain leakage check Hanger adjust
Sliding Type Filter
piping check check
Easy maintenance and extended
product life with sliding type anti-biotic
Anti-biotic filter Easy cleaning
filter.
Sliding type
LG has been able to create a design conscious indoor unit that • Neo Plasma Air Purifying System
compliments any interior decoration. And they have improved • Digital Air Flow Control
air flow innovatively to realize world’s lowest noise, and provide • Swirl Swing
a more pleasant and convenient indoor environment.
• Child Lock Function
Polluted Air Clean Air Neo Plasma Air Purifying Digital Air Flow Control
01 02 03 04 05 System The air flow can be controlled
LG’s unique NEO Plasma air purifying to ensure maximum comfort and
system is equipped with 7 specialized filters convenience.
in 5 separate stages to enhance its cleaning
power. It reduces fine dust and mold, Normal Jet cool Sleep mode
fast & even widely speedy & powerful indirectly & softly
unpleasant odors and cigarette smoke
Odor Free! Dust Free! Allergy Free! as air passes through each filter.
Indoor Unit
Swirl swing (plaesant air) Normal air flow Swirl Swing
01 Pre Filter 05 Plasma Filter Swirl swing distributes air evenly
throughout the room to ensure a more
The antibacterial pre-filter primarily reduces The PLASMA Air Purifying System developed uniquely comfortable conditioned environment
large dust, mold and quilt dust. by LG not only reduces microscopic contaminants and
by adjusting the movement of the vane.
dust, but also reduces house mites, pollen, and pet
fur to reduce allergy and asthma symptoms.
02 Nano Carbon Filter
The triple filter consists of three specialized filters to Nano Nano Nano Nano
Vertical Temp. differences Horizontal Temp. differences
46_47
reduce the symptoms associated with various organic Particle Particle Particle Particle
Indoor Unit
Capacity Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1
removing any remaining moisture.
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Pressing the Auto Clean button will activate Heating kW 2.5 3.2 4.0 5.0 6.3 8.0
the automatic cleaning function after the
cooling operation. Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Power Cooling W 40 40 40 40 40 40
Input Heating W 40 40 40 40 40 40
2 STEP
Power Supply Ø, V, Hz 1, 220~240, 50
Removes moulds through the Dimensions(WxDxH) mm 895x165x282 1090x178x300
neo plasma system.
Weight kg 9 9 9 9 12 12
Only the fan will operate to dry the inner part
of the air conditioner in just 30 minutes. Noise level dBA±3 37 / 33 / 23 39 / 35 / 25 41 / 36 / 27 42 / 36 / 27 44 / 40 / 36 46 / 41 / 38
Air flow rate H/M/L CMM 5.6 / 5 / 4.6 7 / 6.5 / 6 9.5 / 9 / 8.5 10.5 / 9 / 8.5 12 / 10.5 / 9 14 / 13 / 10
Neo Plasma air purifying filter o o o o o o
Piping Liquid mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Connection Gas mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Air Flow Direction Control
48_49
desired by using the remote controller.
* Accessories
Model ARNU07GSEL2 ARNU09GSEL2 ARNU12GSEL2 ARNU15GSEL2 ARNU18GS5L2 ARNU24GS5L2
Mirror
Silver Gold
50_51
* Accessories * Accessories
Model ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2 Model ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
4 Way Cassette (570*570) 4 Way Cassette (840*840)
ARNU05GTRC2 / ARNU07GTRC2 ARNU24GTPC2 / ARNU28GTPC2
ARNU09GTRC2 / ARNU12GTRC2 ARNU36GTNC2 / ARNU42GTMC2
ARNU15GTQC2 / ARNU18GTQC2 ARNU48GTMC2
* Accessories * Accessories
52_53
Model ARNU05GTRC2 ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU15GTQC2 ARNU18GTQC2 Model ARNU24GTPC2 ARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Front Panel PT-UQC
Front Panel PT-UMC
Auto Elevation Grille PTEGM0
Ventilation Kit PTVK410 / PTVK420 / PTVK 430
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
2 Way Cassette 1 Way Cassette
ARNU18GTLC2 / ARNU24GTLC2 ARNU07GTJC2 / ARNU09GTJC2
ARNU12GTJC2
54_55
* Accessories * Accessories
Model ARNU18GTLC2 ARNU24GTLC2 Model ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Front panel PT-HLC Front panel PT-HJC
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
Low Static Duct Built-in Duct
ARNU07GB1G2 / ARNU09GB1G2 ARNU07GB3G2 / ARNU09GB3G2
ARNU12GB1G2 / ARNU15GB1G2 ARNU12GB3G2 / ARNU15GB3G2
ARNU18GB2G2 / ARNU24GB2G2 ARNU18GB4G2 / ARNU24GB4G2
56_57
* Check up the note, refer to on the 49 page.
* Accessories * Accessories
Model ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
Model ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2
Without case(1 contact point) PQDSA
Without case(1 contact point) PQDSA
Dry Contact Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) With case(2 contact point) PQDSBC
PQDSBC
Suction Grille PBSGB30 PBSGB40
Suction Canvas PBSC30 PBSC40
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
High Static Duct High Static Duct
ARNU07GBHA2 / ARNU09GBHA2 ARNU28GBGA2 / ARNU36GBGA2
ARNU12GBHA2 / ARNU15GBHA2 ARNU42GBGA2 / ARNU48GBRA2
ARNU18GBHA2 / ARNU24GBHA2 URNU76GB8A2 / URNU96GB8A2
58_59
* Accessories * Accessories
Model ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2 Model ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
Ceiling & Floor Ceiling Suspended
ARNU09GVEA2 / ARNU12GVEA2 ARNU18GVJA2 / ARNU24GVJA2
60_61
* Accessories * Accessories
Model ARNU09GVEA2 ARNU12GVEA2 Model ARNU18GVJA2 ARNU24GVJA2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
Floor Standing Floor Standing
with case without case
ARNU07GCEA2 / ARNU09GCEA2 ARNU07GCEU2 / ARNU09GCEU2
ARNU12GCEA2 / ARNU15GCEA2 ARNU12GCEU2 / ARNU15GCEU2
ARNU18GCFA2 / ARNU24GCFA2 ARNU18GCFU2 / ARNU24GCFU2
62_63
* Accessories * Accessories
Model ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2 ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2 Model ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
Without case(1 contact point) PQDSA Without case(1 contact point) PQDSA
Dry Contact With case(1 contact point) PQDSB/ PQDSB1 Dry Contact With case(1 contact point) PQDSB/ PQDSB1
With case(2 contact point) PQDSBC With case(2 contact point) PQDSBC
Wired remote controller Wireless remote controller Wired remote controller Wireless remote controller
Deluxe type Standard type Simple type Simple type for hotel Deluxe type Standard type Simple type Simple type for hotel
PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0 PQRCUDS0* PQRCUSA1 PQRCUCS0C PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.) * For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
Heat Recovery Ventilator
With today’s concern for a healthy indoor environment,
eco V is an integral component of HVAC system.
eco V Using in the HVAC system allows contaminants to be
removed quickly and effectively from the air-conditioned
space.
62 Features
63 Installation & Maintenance
64 Line-up
66 Specifications
Features Installation
• High Efficiency Heat Exchanger & Maintenance
• Bypass Ventilation
• Strong Filter Function • Flexibility Installation
• Easy Cleaning and Changeable Filter
Low Top
66_67
• HEPA+Deodorization Filter (accessory) HEPA + Deodorization filter (accessory)
The indoor air can be always kept fresh through these filters.
• Yellow Sand Filter (accessory) • Remove free filter • Remove heat exchanger
Dust collection efficiency (%) Pressure loss (Pa)
• High Efficiency Heat Exchanger
• Bypass Ventilation
The LG heat recovery ventilation system, eco V
• Strong Filter Function
is the solution for improving your indoor air quality.
• Flexibility of Installation
LZ-H1006BA0
LZ-H0256BA0 LZ-H0356BA0
Power Supply (Ø, V, Hz) _ Power Supply (Ø, V, Hz) _
1Ø, 220~240V, 50Hz 1Ø, 220~240V, 50Hz
68_69
LZ-H0506BA0 LZ-H2006BA0
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch) Dimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch)
Weight _ 52kg (114.7 lb) Weight _ 146kg (321.9 lb)
eco V ensures the fresh enviroment in your life!
Heat Recovery Ventilator
* Specifications * Specifications
Item Unit LZ-H0106BA0 LZ-H0156BA0 LZ-H0256BA0 LZ-H0356BA0 LZ-H0506BA0 Item Unit LZ-H0806BA0 LZ-H1006BA0 LZ-H1506BA0 LZ-H2006BA0
Nominal Capacity CMH(L/S) 100(28) 150(42) 250(69) 350(97) 500(139) Nominal Capacity CMH(L/S) 800(222) 1000(278) 1500(417) 2000(556)
Power Supply Ø,V,Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220~240, 50 Power Supply Ø,V,Hz 1, 220~240, 50 1, 220~240, 50 1, 220~240, 50 1, 220~240, 50
Step - SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW Step - SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW SUPER-HIGH/HIGH/LOW
Current SH/H/L Amps 0.32/0.3/0.28 0.36/0.36/0.35 0.55/0.5/0.34 1.40/1.33/0.9 1.51/1.39/1.06 Current SH/H/L Amps 2.8/2.7/2.6 3.0/2.9/2.6 5.6/5.4/5.2 6.0/5.8/5.2
Power Input SH/H/L W 68/60/50 83/80/78 130/115/80 205/195/170 260/225/200 Power Input SH/H/L W 405/360/320 560/540/470 950/925/795 1020/970/860
eco V Mode
eco V Mode
Air Flow SH/H/L CMH(L/S) 100/100/90(59/59/53) 150/150/100(42/42/28) 250/250/180(69/69/50) 350/350/210(97/97/58) 500/500/320(139/139/89) Air Flow SH/H/L CMH(L/S) 800/800/660(222/222/183) 1000/1000/800(278/278/222) 1500/1500/1200(417/417/333) 2000/2000/1600(556/556/444)
External Static Pressure SH/H/L Pa(in.wg) 40/35/30(0.16/0.14/0.12) 70/55/45(0.28/0.22/0.18) 65/50/40(0.26/0.2/0.16) 170/88/40(0.68/0.35/0.16) 150/60/28(0.60/0.24/0.11) External Static Pressure SH/H/L Pa(in.wg) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24)
Bypass Mode
Air Flow SH/H/L CMH(L/S) -/-/- -/-/- -/-/- 350/350/210(97/97/58) 500/500/320(139/139/89) Air Flow SH/H/L CMH(L/S) 800/800/660(222/222/183) 1000/1000/800(278/278/222) 1500/1500/1200(417/417/333) 2000/2000/1600(556/556/444)
External Static Pressure SH/H/L Pa(in.wg) -/-/- -/-/- -/-/- 170/88/40(0.68/0.35/0.16) 150/60/28(0.60/0.24/0.11) External Static Pressure SH/H/L Pa(in.wg) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24) 200/110/60(0.80/0.44/0.24) 160/90/50(0.80/0.44/0.24)
Temperature Exchange Efficiency SH/H/L % -/-/- -/-/- -/-/- -/-/- -/-/- Temperature Exchange Efficiency SH/H/L % -/-/- -/-/- -/-/- -/-/-
70_71
Size(Ø) mm(inch) Ø100(Ø3.94) Ø100(Ø3.94) Ø150(Ø5.91) Ø200(Ø7.87) Ø200(Ø7.87) Size(Ø) mm(inch) Ø250(Ø9.54) Ø250(Ø9.54) Ø250(Ø9.54)+Ø350(Ø13.77) Ø250(Ø9.54)+Ø350(Ø13.77)
Supply Air Fan Qty EA 1 1 1 1 1 Supply Air Fan Qty EA 1 1 2 2
Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive Direct-Drive Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive
Exhaust Air Fan Qty EA 1 1 1 1 1 Exhaust Air Fan Qty EA 1 1 2 2
Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive Direct-Drive Type - Direct-Drive Direct-Drive Direct-Drive Direct-Drive
Filters Qty EA 2 2 2 2 2 Filters Qty EA 2 2 4 4
Type - Cleanable Cleanable Cleanable Cleanable Cleanable Type - Cleanable Cleanable Cleanable Cleanable
Size(WxHxD) mm(inch) 580x10x113(22.83x0.39x4.45) 580x10x113(22.83x0.39x4.45) 580x10x175(23.23x0.39x6.89) 855x10x166(33.66x0.39x6.54) 855x10x166(33.66x0.39x6.54) Size(WxHxD) mm(inch) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37) 1056x10x212.5(41.57x0.39x8.37)
Notes: Notes:
1. eco mode - Enthalpy Heat Recovery Ventilation mode 1. eco mode - Enthalpy Heat Recovery Ventilation mode
2. Noise level : 2. Noise level :
- The operating conditions are assumed to be standard. - The operating conditions are assumed to be standard.
- Sound measured at 1.5m below the center the body. - Sound measured at 1.5m below the center the body.
- Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
& Accessory
(LG Network Solution)
V-net Line up
Wired Remote
Controller Simple PQRCUCSOC
PQRCFCSOC
Standard PQRCUSA1
& Accessory
PQRCUDS0 (White)
Deluxe PQRCUDS0B (Blue)
PQRCUDS0S (Silver)
AC Smart &
PQCSW320A0E
128 Unit Expansion Kit
PQCSE440U0
72_73
ACP&AC Manager
PQCPA11A0E(Without IO)
PQCPB11A0E(With IO)
PQCSS520A0E(AC Manager)
BNU
PQNFB16A1 PQNFB17B0
( ) (BACnet)
V- n e t & A c c e s s o r y
PDI, Remote temperature sensor, Dry contact, Cool/Heat selector, DO Kit
74 Remote Controller Accessory Ventilation Kit (4Way Cassette), AHU Control kit & EEV kit, Refrigerant Charging Kit
Air guide, Suction grille and canvas, Heat recovery unit, Header, Y branch
76 Central Controller
84 Accessory
Remote Controller Remote Controller
•Wired Remote Controller
Our air conditioning system can be controlled by various types of
remote controllers providing general control to unique function. •Simple Wired Remote Controller
•Wireless Remote Controller
& Accessory
PQRCUSA1 Wireless remocon receiver √
Master setting of indoor units
ΔT setting (For Auto Changeover) MULTI V SYNC II
2 Controllers to 1 indoor units
Simple for Hotel
: Applicable for only MULTI V II SERIES
Features PQRCFCSOC
74_75
PQRCUDS0B (Blue) Child lock √
PQRCUDS0S (Silver) * Wireless Remote Controller
Features PQWRHDF0
* Wired Remote Controller for Operating mode On_Off / Fan speed / Mode / Temp.
Room temperature checking √
Standard Chaos swing / Jet cool √
On_Off timer √
Features PZRCUSB0 Sleep mode auto √
On / Off LED √ Main / Sub setting of indoor units
Ventilation mode setting √ ΔT setting (for Auto Changeover) MULTI V SYNC II
Rapid ventilation √
: Applicable for only MULTI V II SERIES
Power saving ventilation √
Reservation Weekly / Simple
Electric failure compensation Max. 2 hours PQWRHDF0
Child lock √
Plasma / Heater / Humidifier
Optional function
PZRCUSB0 Operating air volume
Simple Central Controller AC Smart & 128 Unit Expansion Kit
• A central controller for managing small sites For the mid sized buildings up to 64 or 128 indoor units
• Control up to 16 indoor units can be controlled and monitored by touch screen central
controller. It’s possible to control and monitor the air
PQCSW320A0E conditioning system through web access, anywhere with
computer.
PQCSE440U0
PQCSB101S0
Features PQCSB101S0
Max. no of indoor units 16 indoor units
Individual control On_Off Control
Lock function Total / Individual
Mode change Cooling / Heating
Malfunction indicator LED lamp
Dimension(mm) 120 x 120 x 20
Power(V) DC 10V
& Accessory
Function Controller & Scheduler
It is possible to control, monitor and schedule the *128 Indoor unit Expansion Kit: PQCSE440U0
*DO Kit : PQNFP00T0
operation of indoor units by using these controller
in company with a simple central controller
76_77
MULTI V SYNC
MULTI V SPACE
DC Comm, Line
Max. no of indoor units 16 indoor units 16 indoor units AC Smart
PMNFP14A0 (Max. 16 Indoors)
Individual control On_Off / Fan speed / Mode / Temp. PQCSW320A0E
On_Off / Fan speed / Mode / Temp. PMNFP14A1 (Max. 48 Indoors)
Eco-V
PHNFP14A0
Application
ACP (Advanced Control Platform)
• Through embedded web control function in ACP
one can control and monitor various functions of
air-conditioner such as temperature setting,
schedule, peak power control, etc.
PQCPA11A0E (Without IO)
PQCPB11A0E (With IO)
ACP&AC Manager
• AC Manager is suitable for large site because AC Manager
is the S/W that can control Max. 16 ACP (Max.4,096 indoor units).
& Accessory
Max. 4,096 Indoor
78_79
MULTI V MINI
AC Manager
PQCSS520A0E PI485 AC220V MULTI V PLUS
LAN MULTI V SYNC
DC Comm, Line
• Features HUB
PMNFP14A0 (Max. 16 Indoors)
MULTI V SPACE
& Accessory
L N
Operation Report
• Combination -Operating Time,
Percentage, History Emergency
LGAP
128 Indoor units
Expansion Kit
Digital WHM
(Local purchase) • Remote Controller Restriction
Emergency Interlock Multiple Local Controllers • Automatic Setting
AC220V -Forced Off -Master / Slave • A/C and Vent.
PQNUD1S00 RS485
80_81
or
• Features • Features
- Connection to using LONTALK Controlling Monitoring items - Through embedded web control function in BACnet Controlling Monitoring items
protocol and LG Air-conditioner protocol one can access the airconditioner and external On/Off command
On/Off command On/Off status report On/Off status report
- Process ability Operation mode setting Operation mode status report devices through internet. Operation mode setting Operation mode status report
• 64 units( including indoors and ventilators) Fan speed setting
Fan speed setting Fan speed status report - It can control 256 indoor units. ( A/C or Ventilator ) Fan speed status report
• Valid address for each unit : 0x00 ~ 0x3F
Lock setting Lock status report Lock setting Lock status report
- External devices such as fire alarm, motion
- Self installation verification function using internet Air flow setting Air flow status report Air flow setting Air flow status report
(Web server included) detector can be connected to gateway and their
Set temp. setting Set temp. status report Set temp. setting
• Setting gateway function can be interlinked with airconditioner
User mode setting (for only ventilator) Current space temp. status report User mode setting (for only ventilator) Current space temp. status report
• Diagnosis of communication status on operation.
LG Air-conditioner network Error status report Error status report
- Connection to remote total management system User mode status report User mode status report
(for only ventilator) (for only ventilator)
(LG system)
& Accessory
• Combination • Combination
BACnet
82_83
Indoor unit : Max. 64 units (Air-conditioner & ventilation) Other LON devices
Indoor address : 00 ~ 3F Indoor address : 00 ~ FF
PMNFP14A0
or PMNFP14A0
Eco-V
or PI485 Eco-V
PI485
PHNFP14A0
Simple central AC Smart PHNFP14A0 Simple central AC Smart Outdoor unit Indoor unit
Outdoor unit Indoor unit
controller controller LGAP applied Air-conditioner
LGAP applied Air-conditioner
Remote Temperature Sensor Cool/Heat Selector
It can help to detect the exact room temperature This switch enables selection of heating, cooling
at the optimal position. or fan mode. So it can prevent that cooling & heating
• Model applied to Cassette, Duct type. mixing error occurs during the change of season.
• Part supplied
- Remote temperature sensor
PQRSTA0 - Cable (15m) - Manual PRDSBM
• Features
- Indoor unit control without central controller
• Wiring diagram
Extension cable Connector - Select operation mode : Cooling, Heating, Fan mode
1. Wire to the control box in the indoor unit by - Mode lock for cooling & heating mixing error-proof during the change of season.
removing the existing thermistor and connect
the extension cable its place. Screw terminal
connection • Combination
2. Cut the extension cable to the appropriate Fan Mode
Mode Change
length and connect the screw terminal of the Indoor unit
remote sensor. Cooling Heating
3. In the case of wired remote controller installed,
set the temperature sensing slide s/w at MAIN mode.
Remote
temperature sensor
& Accessory
* PRDSBM is applicable for only MULTI V II Series.
Dry Contact module
• It is connected between indoor units and external
device, so it can be used for various purpose.
Ventilation Kit (4Way Cassette)
Fresh air can be supplied from outside through this
• Accessory • Dimension
• Features
84_85
PQDSA(B) PQDSB1 PQDSBC • Installation Bracket
• Bolt
Contact point 1 contact point 1 contact point 2 contact points • Screw
Power input AC 220V from outside AC 24V from DC 5V&12V from
power source outside power source indoor unit PCB
Voltage / Non voltage input √
On_Off control √ √ √
Lock / Unlock √
Fan speed setting √
Thermo off √
Energy saving √
• Models applied to
Expected temperature setting √
• Ceiling Cassette - 4Way (24k ~ 48k Btu/h)
Error Monitoring √ √ √
Operation monitoring √ √ √
• Specifications • Procedure
1. Arrange manifold, refrigerant charging kit, refrigerant vessel and scale
Weight(kg) Dimension(mm) 2. Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure.
Model Name POWER 3. Connect manifold refrigerant charging kit. Use designated refrigerant charging kit.
NET Gross W H D
If designated refrigerant charging kit isn’t used, the system may get damaged.
Control Kit PRCKA0 2.23 3.6 280 135 280
EEV Kit PRLK048A0 3.1 3.6 404.2 83 217
220~240V / 50HZ / 1Pha 4. Connect refrigerant charging kit and refrigerant vessel.
5. Purge hose and manifold.
6. After “568” is displayed, open the valve and charge the refrigerant
• Selection of evaporator
hen selecting evaporator, Change ‘Option PCB’ in EEV kit according to below table
W
(Basic ‘Option PCB is for 36k Btu/h ) • Application • Dimension
& Accessory
Capacity Allowed heat exchanger Allowed heat exchanger
Option PCB P/No Detail
(Btu/h) Volume (dm3/hr) capacity (kW)
Manifold 202
133
EBR52358907 28k 1.22~1.53 7~9
EBR52358908 36k 1.53~1.91 9~11
(Main PCB) Capacity setting
EBR52358909 42k 1.91~2.14 11~13 'Option PCB'
Refrigerant Charging Kit
EBR52358910 48k 2.14~2.67 13~16 (PRAC1)
EBR52358911 76k 3.06~3.82 20~24
EBR52358912 96k 3.82~4.78 25~31
69
Refrigerant
• Wiring diagram
Single
86_87
Pipe
• Combination
Outdoor unit
Indoor unit
& Accessory
PRHR020 PRHR030 PRHR040
• High flexibility for a wide variety of applications
Max. connectable number of indoor units 2 3 4
PBSGB30 / PBSGB40 Max. connectable capacity of indoor units (Per port/unit) kW 14.1 / 47
PBSC30 / PBSC40 Nominal Input cooling W 26 40 40
heating W 26 40 40
• Features Net weight kg 19 20 21
88_89
Capacity (Btu/h) 1/220 ~ 240/50
Type Model 7k 9k 12k 15k 18k 24k
PBSGB30 √ √ √ √
Grille
PBSGB40 √ √
PBSC30 √ √ √ √
Canvas
PBSC40 √ √
• Dimension
C
C
A A
B B
A B C A B C
PBSGB30 910 359 56 PBSC30 821 274 42~250
PBSGB40 1188 359 56 PBSC40 1100 274 42~250
Header for connection of indoor units Y Branch pipe for connection of indoor units
If you need a highly efficient air condition-
* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II * MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II
ing system in your building, MULTI V is the right
(unit:mm) (unit:mm) (unit:mm) (unit:mm)
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
choice for you.
Model Model Gas Pipe Liquid Pipe Model Model Gas Pipe Liquid Pipe
4 branch 7 branch
ARBL054 ARBL107
ARBLN01621 ARBLN07121
NEO Plasma
7 branch 10 branch Air Purifying
ARBL057 ARBL1010 System Auto Clean
ARBLN03321 ARBLN14521
4 branch 10 branch
ARBL104 ARBL2010
Sleep Mode
Jet Cool Auto Operation
* MULTI V SYNC II
Y Branch pipe for connection of outdoor units (unit:mm) Healthy
Dehumidification Auto Restart
Model Low Pressure Gas Pipe Liquid Pipe High Pressure Gas Pipe
& Accessory
(unit:mm) (unit:mm)
ARBLB01621 Hot Start 4-Way
Model Connection of Gas Pipe Connection of Liquid Pipe Model Connection of Gas Pipe Connection of Liquid Pipe
(Heat pump only) Air Deflection
ARCNN20
Child Lock
Function
ARCNN20
ARBLB03321
( Wired
controller only )
remote Swirl Swing
ARBLB07121
90_91
Two Thermistor
* MULTI V SYNC II (2 Outdoor units) * MULTI V SYNC II (3 Outdoor units)
Control
Model
Gas Pipe Gas Pipe Gas Pipe Gas Pipe
Auto Changeover
ARCNB30
( MULTI
model only )
V SYNC Second
Remote Control