You are on page 1of 16

www.mayan-wt.

com

WaterTech

Helix Automatic Disc Filtration System - 201 Series

Mayan WaterTech's 201 automatic filtration system presents an efficient solution for
filtration in agricultural, industrial, and municipal applications.

Technology
FILTRATION STAGE: The Helix ring generates

a centrifugal effect upon entry into the filter,

moving large particles away from the discs.

The water then passes efficiently through the

depth of the uniquely designed discs.

BACKFLUSHING STAGE: Clean water is

introduced opposite the filtering direction

through the filtering element. This

decompresses the spring loaded discs, allowing


Self cleaning filtering element - Maximum
water savings and efficiency in backwashing. for disc separation, and enhanced backwash

Helix Element - The Helix's "impellers" efficiency.


generate a centrifugal effect reducing the
need for cleaning and washing operations. The dirt on discs is removed from the discs and

Large filtering area and wide range of released through the backwash manifold.
filtration grades - Discs from 5 to 400
microns allow for a variety of applications.
Modularity Versatility, Compatibility - Automatic operation is available in 110 VAC, 220 VAC or 12 VDC.

Allows for a wide range of configurations Special options available for extreme pressures (low, high) and
using a minimal number of components. water conditions (sea or saline water, potable, acidic). Possibility

Low Maintenance - No tools required. to perform backwashing with compressed air, minimizing water
Maximum wear resistance. loss during backwashing.

Minimal Pressure Needed For Flushing.

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Helix Automatic Disc Filtration System - 201 Series

Filtration - Max. Flow Rates


Filtration Maximum Pressure : 10 [bar]
Water
Grades 200-400 130 100 50 20 10 5 Maximum Temperature : 60 Degrees Celcuis
Quality
micron
pH > 4
Good 28 26 22 17 9 7 6
Minimum pressure required for Flush-1.5 [bar]
Average Flow Rate 26 24 21 14 7 5 4
Min. Flow Rate during flush- 10 m3/hr
Poor (m3/h) 24 22 20 10 5 4 3
Very Poor 22 20 18 7 3 2 1

Helix Automatic filtering surface 1,620 cm . 2

Flow rates in table correspond to 2" filters.

Back flushing Head Loss 130 micron - 201 Filtration Systems


1.00
Filtration Grade
100, 130, 200, 400 5, 10, 20, 50
[ Micron]

Minimum Pressure 1.5 bar 2 bar Pressure Loss [bar] 0.20


201
0.10
Minimum Flow Rate 2.5 l/s 2.5 l/s

Materials 0.01
10 20 30 60 100
Flow Rate m3/hr
Housing Polyamide reinforced with fiberglass
Filtering element PP grooved discs
Clamp Stainless Steel
Sealing element NBR

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Premium Line Manual Screen & Disc Filters


300 Series
300 series consists of our premium line manual filters. The disc filter with its Helix centrifugal
action device provides optimized performance and reliability with low maintenance
requirements.
Technology Modular - Versatility and compatibility. Permits
Discs Filter: Water entering the filter through the Helix
a wide range of possibilities with a minimal
number of components.
device generates a centrifical effect that pushes particles in
Maximum reliability - Sturdy design and
the water away from the stacked discs. Water passes
materials guarantee long life and high
through the grooves on the surface of the discs, leaving fine
resistance.
particles in and between the grooves.
Large filtering surface.
Helix technology has two major advantages:
Wide range of filtration grades - Available
1. Decreases the frequency of backwashing, thereby with either discs or screens
minimizing the amount of water used. Exclusive butterfly closure system - Allows
2. Allows discs to“concentrate” on removing finer particles for easy closing, with even pressure and
decompression on the filtering element and
Screen Filter: With a screen filter,
disc stack.
water flows out from the
Water and energy saving.
inside of the filtration
Removable Robust design - Manufactured from
element, leaving the filter element
thermoplastic material.
Disc
particles on the interior filtration Low maintenance - No tools required.
surface of the screen.
HELIX SYSTEM
Minimizes frequency
backwashing and
maintenance

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Premium Line Manual Screen & Disc Filters


300 Series
Models
Max. working pressure: 10 bar
Diameter Max. flow Filtering Surface
BSP Thread m³/h (Discs & Screen) cm2 Maximum temperature: 60 ºC / 140 ºF
pH > 4
2” 30 1200

2” Super 30 1700 130 micron


0.40
3” 50 1200
2"

3” Super 50 1700 2"S

Head Loss (bar)


0.20

4” 70 2400 3"

3"S
4” Super 100 3400 0.10

4"
6” Super 100 3400
0.05 4"S-6"S
Max flow refers to filters with filtration grade of 130 microns.
0 12 25 50 100
Flow (m3/h)
Materials
Head Loss Screen Filters 130 micron
Housing Polyamide reinforced with fiberglass 0.40
Filtering element PP grooved discs
Screen Stainless steel 316L
Clamp Stainless steel
Head Loss (bar)

0.20
Sealing element NBR

2"S
0.10

Available Filtration Grades (micron) 3"S

4"S-6"S
Discs 5 10 20 50 100 130 200 400 0.05
0 12 25 50 100
Screen 100 130 200
Flow (m3/h)

Dimensions (mm)

Filter Connections Dimensions (mm)


Diameter Model
Configuration A B C H W X
2NR BSP BSP BSP
2” 2NV Grooved Grooved BSP 597 309 133
H
2NW Grooved BSP Grooved
2SR BSP BSP BSP M
M
2” C
2SV Grooved Grooved BSP 721 309 133 A B H A
Super
2SW Grooved BSP Grooved X
B
3CR BSP BSP BSP
3” 3CV Grooved Grooved BSP 615 336 147 W
3CW Grooved BSP Grooved
3NR BSP BSP BSP
3”
3NV Grooved Grooved BSP 727 336 147
Super
3NW Grooved BSP Grooved
4NL Grooved Grooved -
4” 950 341 - W
4NB Flange Flange -
4” 4SL Grooved Grooved -
1200 341 -
Super 4SB Flange Flange -
6”
6NB Flange Flange - 1200 531 -
Super

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Premium Line Manual Screen & Disc Filters


300 Series
300 series consists of our premium line manual filters. The disc filter with its Helix centrifugal
action device provides optimized performance and reliability with low maintenance
requirements.
Technology Modular - Versatility and compatibility. Permits
Discs Filter: Water entering the filter through the Helix
a wide range of possibilities with a minimal
number of components.
device generates a centrifical effect that pushes particles in
Maximum reliability - Sturdy design and
the water away from the stacked discs. Water passes
materials guarantee long life and high
through the grooves on the surface of the discs, leaving fine
resistance.
particles in and between the grooves.
Large filtering surface.
Helix technology has two major advantages:
Wide range of filtration grades - Available
1. Decreases the frequency of backwashing, thereby with either discs or screens
minimizing the amount of water used. Exclusive butterfly closure system - Allows
2. Allows discs to“concentrate” on removing finer particles for easy closing, with even pressure and
decompression on the filtering element and
Screen Filter: With a screen filter,
disc stack.
water flows out from the
Water and energy saving.
inside of the filtration
Removable Robust design - Manufactured from
element, leaving the filter element
thermoplastic material.
Disc
particles on the interior filtration Low maintenance - No tools required.
surface of the screen.
HELIX SYSTEM
Minimizes frequency
backwashing and
maintenance

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Premium Line Manual Screen & Disc Filters


300 Series
Models
Max. working pressure: 10 bar
Diameter Max. flow Filtering Surface
BSP Thread m³/h (Discs & Screen) cm2 Maximum temperature: 60 ºC / 140 ºF
pH > 4
2” 30 1200

2” Super 30 1700 130 micron


0.40
3” 50 1200
2"

3” Super 50 1700 2"S

Head Loss (bar)


0.20

4” 70 2400 3"

3"S
4” Super 100 3400 0.10

4"
6” Super 100 3400
0.05 4"S-6"S
Max flow refers to filters with filtration grade of 130 microns.
0 12 25 50 100
Flow (m3/h)
Materials
Head Loss Screen Filters 130 micron
Housing Polyamide reinforced with fiberglass 0.40
Filtering element PP grooved discs
Screen Stainless steel 316L
Clamp Stainless steel
Head Loss (bar)

0.20
Sealing element NBR

2"S
0.10

Available Filtration Grades (micron) 3"S

4"S-6"S
Discs 5 10 20 50 100 130 200 400 0.05
0 12 25 50 100
Screen 100 130 200
Flow (m3/h)

Dimensions (mm)

Filter Connections Dimensions (mm)


Diameter Model
Configuration A B C H W X
2NR BSP BSP BSP
2” 2NV Grooved Grooved BSP 597 309 133
H
2NW Grooved BSP Grooved
2SR BSP BSP BSP M
M
2” C
2SV Grooved Grooved BSP 721 309 133 A B H A
Super
2SW Grooved BSP Grooved X
B
3CR BSP BSP BSP
3” 3CV Grooved Grooved BSP 615 336 147 W
3CW Grooved BSP Grooved
3NR BSP BSP BSP
3”
3NV Grooved Grooved BSP 727 336 147
Super
3NW Grooved BSP Grooved
4NL Grooved Grooved -
4” 950 341 - W
4NB Flange Flange -
4” 4SL Grooved Grooved -
1200 341 -
Super 4SB Flange Flange -
6”
6NB Flange Flange - 1200 531 -
Super

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Automatic Disc Filtration System


Helix Automatic 200 Series, 300 Series
Mayan Water-Tech's automatic filtration systems offer a highly efficient, modular, easy
to install, self cleansing water treatment solution. System features include: automatic disc
filtering elements, 2" valves ( 200 series) or 3" valves (300 series), HDPE manifolds.
Technology
The Helix Automatic Disc Filtration System backflushes one
filtration unit at a time, while the rest of the units continue to
work, allowing for continuous filtration.

Filtration stage: Water entering the filter enters through the Helix
device, generating a centrifical effect that pushes particles in the
water away from the stacked discs. Water passes through the
grooves on the surface of the discs, leaving fine particles in and
between the grooves.

Backflushing stage: Filtered water is introduced from the reverse


direction through the filtering element structure, decompressing
and separating the stacked discs, which causes perfect cleaning of
the discs’ grooves.

Solids expelled from the discs


are evacuated through the
drainage manifold.
Filtration begins again with
compression of the discs.

Backflushing is controlled by
integrated drainage valve and
a controller.
Self-cleaning filtering element - Maximum water
savings and efficiency in backwashing.
Large filtering area and wide range of filtration
grades - Discs from 5 to 400 microns allow for a
variety of applications.
Low maintenance - No tools required for
maintenance.
The modular configuration allows design options based on
Modularity Versatility, compatibility - Allows for a
customer preferences or available space.
wide range of configurations using a minimal
Automatic operation is available in 110 VAC, 220 VAC or 12 VDC.
number of components.
Special options available for extreme pressures (low, high) and
High quality manufacturing - High-density
water conditions (sea or saline water, potable, acidic). Possibility
polyethylene manifolds for maximum resistance
to perform backwashing with compressed air, minimizing water
and durability.
loss during backwashing.
Easy transport and installation - Preassembled
equipment; small foot print.

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Automatic Disc Filtration System


Helix Automatic 200 Series, 300 Series

Filtration - Maximum flow per filter Optimal flow depends on water quality
Helix Automatic filtering surface 1620 cm2 and filtration grade.
300 Series 200 Series Standard filtration system working pressure 1.5-10 bar.
Filtration
Quality
Grades 200-400 130 100, 130 50 20
of Water
micron
Good 32 30 26 17 9 Available Filtration Grades (micron)
Average 30 28 24 14 7
(m /h)
3
Poor 28 26 22 10 5 Discs 5 10 20 50 100 130 200 400

Very Poor 26 24 20 7 3

Backflashing Head Loss Disc Filters 130 micron


0.35 200
Filtration Grades
400, 200, 130 100 50, 20 Seires
micron
Minimum 0.25 202
backflushing 1.5 bar DLP filter 1.5 bar DLP filter 1.5 bar DLP filter
Head Loss (bar)
203
pressureper filter
204
Minimum
backflushing flow 2.5 l/s 2.5 l/s 2.5 l/s 0.15 205
per filter 206

207

How to Choose Helix Automatic Equi­p­ment 0.10 208


1. Determine the required filtration grade (micron). 10 25 50 100 200
2. Establish the quality of the water. Flow (m3/h)
3. Calculate according to the following equation, the numbers of
filters required with the selected SERIES. 0.35 300
Series
Flow to filter in the installation
=
Head Loss (bar)

Number of filters 0.25


Max. Flow per filter 302

303
NOTE: The flow rate given by the filter conditions determines the frequency
of the backwashing. 304

0.15 305
Materials 306

Manifolds Hight Density Polyethylene 307


Housing Polyamide reinforced with fiberglass 0.10 308
Filtering element PP grooved discs 5 25 50 100 200 300
Sealing element NBR Flow (m3/h)

N. Filtering
Model Manifold surface F E D L W R T S H
filters [cm2]
202/3fX 2" x 2 3"= 90 mm 3240 272 204 575 698 700 491 257 272 1080

203/4fX 2" x 3 4"= 100 mm 4860 272 204 830 945 700 511 267 281 1100 H
H

204/6fX 2" x 4 6"= 150 mm 6480 272 204 1065 1220 700 561 292 307 1150
TT
205/6fX 2" x 5 6"= 150 mm 8100 272 204 1420 1542 700 561 292 307 1150 R
R S
S

206/6fX 2" x 6 6"= 150 mm 9720 272 204 1695 1817 700 561 292 307 1150

302/4fX 3" x 2 4"= 100 mm 3240 311 230 644 714 785 573 267 309 1162
LL
303/4fX 3" x 3 4"= 100 mm 4860 311 230 830 956 785 573 267 309 1162

304/6fX 3" x 4 6"= 150 mm 6480 311 230 1065 1220 785 623 292 334 1212
E
E

305/6fX 3" x 5 6"= 150 mm 8100 311 230 1420 1553 785 623 292 334 1212
W
w
FF
306/6fX 3" x 6 6"= 150 mm 9720 311 230 1695 1828 785 623 292 334 1212

306/8fX 3" x 6 8"= 200 mm 9720 311 230 1695 1848 785 633 320 355 1257

D
* Model dimensions are approximate, for accurate dimension please request custom drawings.

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Automatic Disc Filtration System


Helix Automatic 4DCL
Mayan Water-Tech's automatic filtration systems offer a highly efficient, modular, easy to
install, self cleansing water treatment solution. System features include: automatic disc
filtering elements, 3" or 4" flush valves, HDPE manifolds, custom built stands.
Technology
The Helix Automatic Disc Filtration System
backflushes one filtration unit at a time, while the rest
of the units continue to work,allowing for continuous
filtration.
Filtration stage: Water entering the filter enters
through the Helix device, generating a centrifical effect
that pushes particles in the water away from the
stacked discs. Water passes through the grooves on
the surface of the discs, leaving fine particles trapped
between the grooves.
Backflushing stage: Filtered water is introduced from
the reverse direction through the filtering element
structure, decompressing and separating the stacked
discs, which allows for perfect cleaning of the discs’
grooves.
Solids expelled from the discs are evacuated through
the drainage manifold. Filtration begins again with
compression of the
discs.
Backflushing is
controlled by
integrated drainage
valve and
a controller.
Self-cleaning filtering element - Maximum water savings
and efficiency in backwashing.
Large filtering area and wide range of filtration grades -
Discs from 5 to 400 microns adjust to variety of
applications.
Low maintenance - No tools required for maintenance.
The modular configuration allows design options
Maximum resistance with replaceable parts. based on customer preferences or available space.
Modularity - Versatility, compatibility. Allows for a wide Automatic operation is available in 110 VAC, 220
range of flow rates and configurations using a minimal VAC or 12 VDC.
number of components. Special options available for extreme pressures (low,
High-quality manufacturing - High-density polyethylene high) and water conditions (sea or saline water,
potable, acidic). Possibility to perform backwashing
manifolds for maximum resistance and durability.
with compressed air, minimizing water loss during
Easy transport and installation - Pre-assembled backwashing.
equipment; Small foot print.

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Automatic Disc Filtration System


Helix Automatic 4DCL
Filtration - Maximum flow per filter Optimal flow depends on water quality and filtration grade.
Helix automatic filtering surface area: 3,240 cm2 Standard filtration system working pressure 1.5-10 bar.
Quality Filtration
200-400 130 100 50 20
of Water Grades
micron
Available Filtration Grades (micron)
Good 56 52 48 34 18
Average 52 48 44 28 14 Discs 5 10 20 50 100 130 200 400
(m3/h)
Poor 48 44 40 20 10
Very Poor 44 40 36 14 6
Materials
Manifolds High Density Polyethylene
Backflashing
Housing Polyamide reinforced with fiberglass
Filtration Grades
400, 200, 130 100 50, 20, 10, 5 Filtering element PP grooved discs
micron
Minimum Sealing element NBR
backflushing 1.5 bar 1.5 bar 1.5 bar Backflushing valve Plastic
pressureper filter
Minimum
backflushing flow 5 l/s 5 l/s 5 l/s Head Loss Screen Filters 130 micron
per filter Number
0.50
of units:

How to Choose Helix Automatic Equi­p­ment 3


4
1. Determine the required filtration grade (micron). 0.25
Head Loss (bar)

5
2. Establish the quality of the water.
6
3. Calculate according to the following equation, the numbers of
7
filters required with the selected SERIES.
0.12 8
9
Flow to filter in the installation
Number of filters = 10
Max. Flow per filter 11
0.06 12
NOTE: The flow rate given by the filter conditions determines the frequency 75 150 300 600 800
of the backwashing. Flow (m3/h)

N. Filtering
Model filters Manifold area [cm2]
F E D L R T S H

4DCL4/6FX 4" x 4 6"-150 12960 888 277 1145 1305 605 300 1188 1705

H
H

4DCL4/8FX 4" x 4 8"-200 12960 928 277 1195 1300 645 320 1248 1785
S

4DCL5/6FX 4" x 5 6"-150 16200 888 277 1420 1580 605 300 1188 1705

4DCL5/8FX 4" x 5 8"-200 16200 928 277 1470 1580 645 320 1248 1785
LL
4DCL6/8FX 4" x 6 6"-150 19440 928 277 1745 1855 645 320 1248 1785

4DCL7/8FX 4" x 7 8"-200 22680 928 277 2259 2343 645 320 1248 1785

E
E

4DCL7/10FX 4" x 7 10"-250 22680 978 277 2259 2346 700 350 1328 1890 W
W

4DCL8/10FX 4" x 8 10"-250 25920 978 277 2474 2561 700 350 1328 1890

4DCL9/10FX 4" x 9 10"-250 29160 978 277 2749 2833 700 350 1328 1890
DD

4DCL10/10FX 4" x 10 10"-250 32400 978 277 3024 3108 700 350 1328 1890

4DCL10/12FX 4" x 10 12"-300 32400 1043 277 3024 3112 773 390 1433 2025

4DCL11/12FX 4" x 11 12"-300 35460 1043 277 3299 3387 773 390 1433 2025

4DCL12/12FX 4" x 12 12"-300 38880 1043 277 3574 3662 773 390 1433 2025 F
F

R
* Model dimensions are approximate, for accurate dimensions please request custom drawings.
R

TT

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Automatic Hydraulic Screen Filter - LCA Series

Automatic screen filter with hydraulic command system. A wide range of filtration degrees
offers a high performance solution; suitable for a wide range of applications.

Environmentally Friendly - Minimal water loss


during flushing process.

Wide Range of Filtration Degrees -


80-1,000 Microns.

Versatility - Inlet/Outet range from 2"-8".

Resistance - Temperature resistance up to 60 °C.

Large Filtration Surface Area - Up to


erase - pto 7,200 cm2 .

Resistance - Stainless steel screen offering high


Durability - against corrosion.

Easy Installation - Plug and play.

Technology
Mayan automatic screen filters provide an uninterrupted supply of
clean filtered water without interruption during the flushing cycle.

Filtration Process - The water flows through the inlet(1) and enters
the inside of the screen filter.
The water then passes through the screen(2) while the particles get 5
trapped on the inside of the screen element. The filtered water
continues to flow to the outlet(3).

Flushing Process - When the pressure differential (DP) between


inlet and outlet reaches a pre-selected level the flushing cycle starts. 2 3
4
A hydraulic valve opens in the drain port, which causes a suction
force in the inner nozzels(4) of the scanner. This coupled with the
helical movement of the nozzles up and down the screen sucks the
captured particles from the screen directing them to the drain port(5).

The length of the the flush cycle is pre-determined by the control


unit. When the cycle is complete the flush valve closes and the
1
flushing ends. The flushing process uses a minimal amount of water.

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Automatic Hydraulic Screen Filter - LCA Series

Dimensions
Model Inlet/Outlet Max Flow Filtration Flush Flow Flush Time Flush Volume
Flange m³/h Surface Area Rate (Seconds) (Liters)
Diameter (cm2) (l/s)

LCA 900/2 2" 50 25 0.7 8 5


900
LCA 900/3 3" 80 50 0.7 8 5

LCA 1600/3 3" 80 50 0.8 15 12.5


1,600
LCA 1600/4 4" 100 80 0.8 15 12.5

LCA 2400/4 4" 100 80 2,400 0.8 18 15.5

LCA 4800/6 6" 150 150 4,800 2.5 20 53

LCA 7200/6 6" 150 150 - - -


7,200
LCA 7200/8 8" 200 300 - - -

Materials of Construction
Housing-Lid Epoxy-polyester coated carbon steel Max Pressure - 10 (bar).
(S-2350-JR) Min. Pressure for Flushing - 2.5 (bar).
Filtration Screen Stainless Steel 316L screen with PVC or Max. Temp. - 60 °C.
molded PP support sturcture. Flow rate depends on water quality and filtration degree.
Scanner Stainless Steel 304 Option for flanged Inlets/Outlets on all model
Option for threaded Inlets/Outlets on 2" and 3" models.
Seals NBR
Additional Inlet/Outlet diameters may be provided upon request.
Drainage Valve Poly Propylene Drainage Valve - Threaded 1".

Dimensions
Dimensions (mm) Weight (kg)
Model Systems with Systems
L W D B S C E T w/o water w/o water
LCA 900 585 500 480 220 352 220 70 260 110 35
LCA 1600 720 500 480 250 427 220 70 260 136 45
LCA 2400 830 540 570 320 532 260 110 260 173 60
LCA 4800 1,100 540 570 470 807 260 110 260 252 81

Head Loss 125 (micron)


1
Head Loss (bar)

LCA 4.800

LCA 2.400
0.1
LCA 1.600

LCA 900

0.01
10 100 1000
Flow Rate (m3/hr)

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com


www.mayan-wt.com

Automatic Electric Screen Filter - LDB Series

Automatic Screen filter with electrical command system. A wide range of filtration degrees
offers a high performance solution; suitable for a wide range of applications.

Environmentally Friendly - Low water consumption


during flushing cycle.

Wide Range of Filtration Degrees -


10-1,000 microns (SS support) 80-1000 microns
(PVC or M.S. support).

Versatility - Inlet/Outlet from 2"-20".

Resistance - Temperature Resistance up to 60°C.

Large Filtration Surface Area - Up to 21,300 cm2.

Resistance - Screen is made from stainless steel


offering high durability against corrosion.

Easy Installation - Plug and Play.

Technology
Mayan automatic screen filters provide a continuous supply of clean
filtered water without interruption during the flushing cycle.

Filtration Process - The water flows through the inlet(1) and enters
the inside of the screen filter.
The water then passes through the screen(2) while the particles get
trapped on the inside of the screen element. The filtered water
continues to flow to the outlet(3).

Flushing Process - When the pressure differential (DP) between inlet 5


and outlet reaches a pre-selected value the flushing cycle initates.
A hydraulic valve opens in the drain port, which causes a suction
force in the inner nozzels(4) of the scanner. This coupled with the
helical movement of the nozzles up and down the screen sucks the 4 3

captured particles from the screen directing them to the drain port(5). 2

The length of the the flush cycle is pre-determined by the control unit.
When the cycle is complete the flush valve closes and the flushing
ends. The flushing process uses a minimal amount of water.
1

Mayan Watertech P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com
www.mayan-wt.com

Automatic Electric Screen Filter - LDB Series

Technical Data
Inlet/Outlet Max Filtration Flush Flush Flush Flush Valve Max Pressure - 10 (bar).
Flange Flow Surface Flow Time Volume Diameter
Model Diameter )m³/h( Area Rate )Seconds( )Liters( )inch( Min. Pressure for Flushing - 2 (bar).
(cm2) )l/s(
LDB 900/2 50 2" 25 900 0.7 8 5.0 1"
Max. Temp. - 60°C.
LDB 1600/3 80 3" 50 1,600 1.0 15 16.4 1" Engine - 1/4 HP, 220 VAC, 0.72 ampere.
LDB 2400/4 100 4" 80 2,400 1.0 18 18.5 1" Control Unit : 220 VAC (380 VAC available).
LDB 4800/6 150 6" 150 4,800 2.5 20 53 1"
LDB 7400/8 200 8" 300 7,400 4.4 25 108 2" Flow rate depends on water quality and
LDB 9800/8 200 8" 300 9,800 5.8 25 144 2" filtration degree.
LDB 12300/10 250 10" 500 12,300 7.2 25 180 2"
LDB 16100/10 250 10" 500 16,100 5.8 25 144 2"
All models are flanged.
LDB 20100/12 300 12" 600 20,100 7.2 25 180 2"
LDB 1000 S/2 50 2" 25 1,000 0.7 8 5.0 1"
LDB 1000 S/3 80 3" 35 1,000 0.7 8 5.0 1"
LDB 1800 S/3 80 3" 50 1,800 1.0 15 16.4 1" Materials
LDB 2700 S/4 100 "4 80 2,700 1.0 18 18.5 1"
LDB 5400 S/6 150 "6 150 5,400 2.5 20 53 1" Housing-Lid Epoxy-polyester coated
LDB 5400 S/8 200 "8 300 5,400 2.5 20 53 1" carbon steel (S-2350-JR)
LDB 8000 S/8 200 "8 300 8,000 4.4 25 108 2"
LDB 10600 S/10 250 "10 500 10,600 5.8 25 144 2"
Filtration Screen Stainless Steel 316L screen
LDB 13200 S/10 250 "10 500 13,200 7.2 25 180 2" PVC or molded PP support
LDB 13200 S/12 300 "12 600 13,200 7.2 25 180 2" structure.
LDB 16500 S/12 300 "12 600 16,500 5.8 25 144 2" Scanner Stainless Steel 304
LDB 16500 S/14 350 "14 800 16,500 5.8 25 144 2"
LDB 21300 S/14 350 "14 800 21,300 7.2 25 180 2" Seals NBR
LDB 21300S/16 400 "16 1200 21,300 7.2 25 180 2" Drainage Valve Poly Propylene

Dimensions
Dimensions (mm) Weight (kg)
Model Systems Systems
L W D B S C E T M with water w/o water
LDB 900 900 522 574 220 352 220 71 258 1,150 103 40
LDB 1600 970 522 574 250 427 220 71 258 1,250 121 45
LDB 2400 1,090 565 645 320 532 260 112 256 1,350 190 60
LDB 4800 1,365 565 645 470 807 260 112 256 1,620 283 86
LDB 7400 2,045 740 825 600 1,176 350 350 408 2,620 795 270
LDB 9800 2,320 715 825 900 1,451 350 350 408 2,900 953 308
LDB 12300 2,590 715 825 900 1,722 350 350 408 3,440 1,096 334
LDB 16100 2,335 865 975 900 1,478 400 400 408 3,000 1,323 460
LDB 20100 2,620 865 975 930 1,760 400 400 408 3,455 1,546 521
LDB 1000S 900 522 574 220 352 220 71 258 1,150 116 52
LDB 1800S 970 522 574 250 427 220 71 258 1,250 131 54
LDB 2700S 1,090 565 645 320 532 260 112 256 1,250 207 75
LDB 5400S 1,365 565 645 470 807 260 112 256 1,620 523 304
LDB 8000S 2,045 740 825 600 1,176 350 350 408 2,620 891 357
LDB 10600S 2,320 715 825 900 1,451 350 350 408 2,900 1,022 371
LDB 13200S 2,590 715 825 900 1,722 350 350 408 3,440 1,179 409
LDB 16500S 2,335 865 975 900 1,478 400 400 408 3,000 1,427 554
LDB 21300S 2,620 865 975 930 1,760 400 400 408 3,455 1,712 672

Head Loss 125 (micron)


1
Head Loss (bar)

0.1 LDB 4800 LDB 16100

LDB 2400 LDB 12300


LDB 7400
LDB 1600
LDB 900 LDB 20100
LDB 9800
0.01
10 100 1000

Flow Rate (m3/hr)

P.O.Box 343, Kfar Tavor, 1524100, Israel T +972.4.6772166 F +972.4.6772682 E office@mayan-wt.com