Microbial reduction in cooling towers is paramount in regulatory climate. Improving the water
quality in the cooling loop is a simple, cost effective method of realizing efficiency gains.
Mesan offers pre-installed basin sweeping piping systems for our cooling towers to work
with VAFTM filtration systems to reduce Legionella contamination of building water systems
and make water treatment more effective.
1
COMMON DIFFICULTIES
Legionnaires’ Disease
• Serious form of pneumonia which can be fatal
• Legionellosis is caused by the bacteria Legionella
• Humans can only be infected through the respiratory system by
inhaling very small droplets (mist) of infected water in the range of
1 to 5 microns (droplet size)
Scaling
Scale is caused by the precipitation of mineral particles especially
calcium carbonate in water to form a hard deposit on heating
transfer surfaces. The formation of scale greatly affects cooling tower
performance and increases maintenance cost. 0.25mm scaling or
fouling will result in 10% reduction of heat transfer efficiency.
(ASHRAE Systems and Equipment Handbook)
Corrosion
Deposits from corrosion also form blockage of pipes which reduce
normal water flow, foul heat exchange surfaces, and reduce cooling
tower performance.
Bacteria
Cooling tower basins are good habitats for microbiological organisms.
Apart from accelerating the corrosion process and reducing system
life, biological activities also contribute to health problems such as
Legionnaires' disease.
100.0%
90.0%
80.0%
Low Heat Flux Coil
70.0%
60.0%
50.0%
High Heat Flux Coil
40.0%
0 0.002 0.004 0.006
Clean Tube 1/32'' Scale 1/16'' Scale 3/32'' Scale
(0.8 mm) (1.6 mm) (2.4 mm)
Fouling Factor & Approximate Scale Thickness On Coil
“Cooling tower operation and maintenance for improved energy efficiency” – CTI / ASHRAE
2
Cooling Tower Filtration Systems
FILTRATION SY
CENTRIFUGAL SEPARATORS
How it works
VAFTM brand Hydrocyclone Separators are effective in removing
suspended particles from any flow stream of water where the specific
gravity (density) of the particle(s) is heavier than the fluid it is in; the
more significant the difference in gravity between the water and the
particle, the greater the efficiency of the removal process.
MAX
98%
MANGANESE 7.4
LCS-Series Standard features include basic painte
manual
90%purge valve. Options include auto purge and
GRAVEL 3.0
without pump and pump control.
Tower Flow Rate
FLOW RATE RANGE
LIMESTONE, 2.9
MARBLE
80% 3
Tonnage gpm m /hr no pump
ALUMINUM 2.7
SAND
2.6 300 100 23 LCS100
400
70% 150 34 LCS150
COAL ASH 2.0 500 200 45 LCS200
1000 300 68 LCS300
SILT 1.2 1800
60% 500 114 LCS500
WATER 1.0
3
For 0%
Separator withflushing water wastage, use recovery vessel with separator
Recovery vessel
Flush
Recovery Vessel • Carbon (epoxy coated), 304 stainless
Outlet Gate ISO Valve
steel or 316 stainless steel material
Separator • 10 bar (150 psi) pressure rating
• Low pressure drop
Isolation
Ball Valve
• Quick swing closure with eye nuts
Inlet • Viton seals - lid and basket
• Differential, drain and vent ports
Pump Starter • Adjustable support legs
Strainer
• 316 stainless steel strainer basket
LCS-Series Standard features include basic painted steel skid, VHS separator, isolation valve and
manual purge valve. Options include auto purge and bag recovery vessel. Also available with or
without pump and pump control.
4
Cooling Tower Filtration Systems
How it works
Dirty water enters the filter through the inlet, then flows to the inside of the fine screen and passes
through the fine screen from the inside out. Dirt is collected on the inside surface of the fine screen.
The clean filtered water then exits through the filter outlet. when a pressure differential across the
screen increases to a maximum of 0.5bar (7psi).10 to 15 second flush cycle automatically initiated
and it cleans screen in one pass, meanwhile filter still remains online.
Filter area
LCF-Series self-cleaning screen filters with cleaning nozzles
• Screens act as a barrier to all particulate
• Remove both organic and inorganic
particulate down to 10 micron
• Least flush waste to self-clean
• Zero flush waste when considering
cooling tower blowdown requirements
5
LCF-Series automatic self-cleaning filter skid
LCF-Series Standard features include: basic painted steel skid,
V-200P automatic filter, isolation valve, flushing control and
diaphragm flush valve. Optional bag recovery vessel may also be
added. Also available with or without pump and pump control.
Tower Skid Flow Rate Model Pump
Tonnage gpm 3
m /hr no pump with pump HP/kW
300 50 11 LCF200 LCF200-5 5 / 3.7
500 100 23 LCF200 LCF200-5X 5 / 3.7
700 150 34 LCF200 LCF200-7.5 7.5 / 5.5
* wattages may vary depending on pump selection.
3 4
6
CTI Series
MXH SERIES MXL SERIES MFD SERIES MXC SERIES MCC SERIES MHD SERIES
Cross Flow Cross Flow Counter Flow Closed Circuit Counter Flow Cross Flow Induced Draft
Induced Draft Induced Draft Forced Draft Cross Flow Induced Draft Induced Draft Single Inlet Horizontal Discharge
GB Series
MSX-R SERIES MST-1000 SERIES MST-3000 SERIES MST-7100 SERIES MST-2000 SERIES MKT SERIES
Cross Flow Induced Draft Cross Flow Induced Draft Cross Flow Induced Draft Closed Circuit Counter Flow Induced Draft Counter Flow Induced Draft
Single Inlet Horizontal Discharge Single Air Inlet Cross Flow Induced Draft
www.mesanct.com
sales@mesanct.com
Founded in Hong Kong in 1972, MESAN is a pioneer cooling tower manufacturer in the green
movement. MESAN delivers environmentally-conscious and cost effective cooling to the industrial,
refrigeration and HVAC markets. From plume-abatement, energy efficiency, noise reduction to
water filtration system, we offer sustainable cooling solutions for green builders.