Nokia Central and Edge Data Center Solutions

Juho Jaakkola
Datacenter evengelist
1 © Nokia 2016
Nokia Solutions and Networks
Agenda for this session

• Layered architecture
• Nokia data center solution
• Technology evolution path

2 © 2018 Nokia
Comprehensive portfolio and expertise

Mobile Fixed IP / Optical Nokia Global Nokia Nokia


Networks Networks Networks Software Services Technologies Bell Labs

3 © 2018
NokiaNokia
2016 Public
Top technology talent

• 37,000 R&D professionals


• EUR 119 billion on R&D over 20 years
• Innovation + social impact
4 © 2018
NokiaNokia
2016 Public
Unrivalled track
record of innovation

1300+ 9 3 2 2 1
Patent applications Nobel Prizes Turing Prizes Grammys Emmys Oscar
(in 2017)

5 © Nokia 2016 Public


Megatrends are changing the world,
and the ways we connect with it

Network, Internet Augmented Human Social & trust Digitalization


compute of Things intelligence & machine economics & ecosystems
& storage interaction

Broadband Connectivity for Human assistance Virtual and Sharing economy Digitalization of
everywhere, a trillion things and task automation augmented and digital currencies services, operations,
distributed at machine scale reality, making trust and network and
cloud, near reshaping how security essential supply chain
infinite storage we interact with

6 © 2018 Nokia
Managing the lowest latency/cost trade off with a layered architecture

Edge data centers Central data centers

Lowest latency / high throughput


Signaling driven

Far edge Aggregated edge Regional Central Public


7 © 2018 Nokia
Managing the lowest latency/cost trade off with a layered architecture
Datacenter portfolio for all deployments from Far Edge to HyperScale
Edge data centers Central data centers

Lowest latency / high throughput


Signaling driven
Compact OpenRack or Full size/compact OpenRack Full size OpenRack
Open Edge 19” Rack-mount or Open or 19” Rack-mount
Edge or 19” Rack-mount
Sites 100-1000’s 10-100’s <10 2-3
Footprint Smallest Small Large Large
Power budget Low Medium Medium - High High

Far edge Aggregated edge Regional Central

8 © Nokia 2018
Nokia Datacenter Solution offering

Services
Cloud-Native VNFs, E2e Solutions and OSS
Security Management

Cloud Security

Nokia CloudBand Network Security

Cloud Infrastructure SW Nuage Networks Endpoint


Security
SDN Controller
AirFrame Hardware
IP Router NetGuard
Rackmount, Open Compute
(OCP), Open Edge (OE) Inter DC Networking Build-in Endpoint Security

Modular Data Center


Containerized Data Center

9 © Nokia 2018
AirFrame Datacenter : Scalable Compute from A Single Server to Hyper Scale

AirFrame OpenRack AirFrame Rack-mount AirFrame OpenEdge


Standard 19” Open Compute proposed
OpenRack v2 rack-mount architecture for far edge
compliant high server and deployments (fits to 19” wide,
density server and storage systems 600mm deep rack)
storage systems
(21”)

Hyper Scale Efficiency with Open Compute Easy scalability for datacenters with OCP benefits to small edge cloud
Project (OCP) Rack Mount configuration deployments

10 © Nokia 2018
Optimal server form factor for every use case
From ultra-compact to hyperscale

Rack-mount Open Open


Rack Edge
Open Edge OpenRack
780 mm 720 mm 430 mm

210 mm

Rackmount

170 mm
440 mm

11 © 2018 Nokia
OCP delivers industry Green datacenters
Power Usage Effectiveness

leading density per rack


(PUE) measures how efficiently
a Data Center uses energy

and Lean operations


Top 3 OCP benefits:
Low PUE reduces OPEX and emissions
1. Improve footprint efficiency
OCP Data Center
2. Green datacenters consumes 35% less
No special tools required
energy than a traditional
3. Operational efficiency Data Center Simpler hardware tasks, 4x
faster to perform than on
traditional servers
Improves floor space
High Rack Efficiency 25K servers /operative
utilization

Hot
aisle
Cool
aisle
Reduction in number of 50% improved density* All operation from cool aisle
12 © Nokia 2018 racks required*
Nokia is Platinum member of OCP and OCP Solution provider

Recognizing OCP Products • Nokia AirFrame OR18 rack is fully ORv2 compliant -
OR18 servers and JBOD are in process of being
contributed as ”OCP Inspired” during 2H 2018
Products that comply 100% with Products that comply 100% with an Worldwide Delivery, Service,
an OCP accepted specification and OCP accepted specification and are Support Network
the design files are open sourced available from a Gold, Silver or
and available. Platinum member of OCP
• Contribution process has been started for AirFrame
OE19 chassis for ”OCP Accepted” and OE19 server for
”OCP Inspired” status, targeted to close by early 2019

• In July ’18, OCP community elected new lead for OCP


Telco project
OCP-Accepted™ or OCP-Inspired™ Products demonstrate • Co-lead by Craig White /Nokia AirFrame R&D
Efficiency, Openness, Impact,& Scale together with Sumitra Bhojan /AT&T

13 © Nokia 2016
OCP is enjoying high adoption rate driven by multiple verticals
”Telco OCP spend will surpass Non-Board* hyperscalers in 2021”

“Growth rate of OCP Non-Board*


revenue in high double digits out to
2021” à $6Bn market in 2021

“Telcos increase POCs in 2017,


production trials ramp in 2018, scale
deployments 2019+”

* Report excluded OCP Board members Facebook, Microsoft and Rackspace, including them would approximately double the market
14 © Nokia 2018
Managing the lowest latency/cost trade off with a layered architecture
Datacenter portfolio for all deployments from Far Edge to HyperScale
Edge data centers Central data centers

Lowest latency / high throughput


Signaling driven
Compact OpenRack or Full size/compact OpenRack Full size OpenRack
Open Edge 19” Rack-mount or Open or 19” Rack-mount
Edge or 19” Rack-mount
Sites 100-1000’s 10-100’s <10 2-3
Footprint Smallest Small Large Large
Power budget Low Medium Medium - High High

Far edge Aggregated edge Regional Central

15 © Nokia 2018
Anatomy of Edge
Architectural requirements for edge computing
Performance Scalability Security Operability

• Space and resource • SW and HW need • Physical security • Remote


constraints to scale • Data locality deployment and
• Support for • Flexible scalability maintenance
• Government
workload based from one to many compliance • Fully automation
accelerators e.g. • From single node via API
SmartNIC’s to multiple racks • HW agnostic
• Energy efficiency

16 © 2018 Nokia
Imperceptible latency – Shift to ‘human’ control changes everything

High-Frequency trading 0.25


Service latency requirements (in ms) Light propagation in optical fiber
Electric grid control 1
(km)
Autonomous vehicles 2 8 10000
Cloud RAN 4
1000
Vestibulo-ocular reflex 7

Edge cloud
Haptic VR & tele-operation 5 20 100

Cloud-assisted driving 10 100 10


BW-efficient 360° video 10 40

Hi-Res cloud gaming 20 90 0.1 1 10 100 RTT

Central cloud
(ms)
Sprint start 120

4K video streaming 50 1900


Max tolerable networking delay
VoIP/video conferencing 100 50
Max application delay for processing
Web page load 150 1000
Human response times (for reference)
150 4000
IM chat & bots

Radical shift in network architecture needed to deliver required latency


17 © 2018 Nokia
AirFrame open edge server: 5G performance in compact size
First x86 solution designed to fully support edge / far-edge cloud deployments

ARCHITECTURE Environmental
Ultra-small footprint • 19” compatible: fits in any 600mm cabinet • Full NEBS compliancy,
• Compact form factor: ranging from 2RU to 5RU high chassis seismic zone 4 [GR-63-Core,
• Sleds either 1RU or 2RU high GR-1089-Core]
• Fully front-operated (cabling, open rack-like • Extended operating
tool less serviceability) temperature range:
-5C..+45C [ETSI EN300 019-
• Support for high end accelerators
1-3 Class 3.2]
• High availability: No SPOFs, redundant fans, hot swap storage
• Redundant fans; air flow configurable front to rear/rear to front

DIMENSIONS POWER MANAGEMENT FLEXIBLE


• 133.5 (3RU) x 444 x 460 mm (H • 2N redundant AC & DC • All sleds managed through • Memories, disks and NICs
x W x D) power supplies single interface in RMC unit from common AirFrame
• Ca. 20.0 kg / 44.1 lbs. (Chassis • Power fed to sleds through • On board BMC portfolio
with PSU’s and RMC) backplane (in server sleds)
• 400W per 1U sled

18 © 2018 Nokia
Nokia AirFrame open edge server acceleration

Cloud RAN Machine


• 4G/5G L1/L2 real- Learning/Artificial
time acceleration Intelligence
• 100% better • Video analytics
performance
• Image recognition
• 10x faster

Content
acceleration
• Encoding,
enriching, More data center
transcoding capacity per m2
• 30x faster

19 © 2018 Nokia
Automation with Nokia data center system manager
Common management centralized and distributed data centers
• Single view and operation over data centers
Open data center • Real-time data for automated operations
management solution • Increase utilization of servers and improve power efficiency
1. Vendor-agnostic hardware • Analytics for smart capacity planning for future workloads
management • Automated datacenter deployment using Ansible
2. Open south-bound and north-
bound APIs (Redfish, Customer trial in Europe: OpenRack automated deployment with
IPMI,RESTful etc.) AirFrame Datacenter Management

Firmware
Mgmt switch Allocate mgmt Inventory data Configure leaf Deep inspection OS image
update for all
configuration IP to servers collection switches of server nodes servers deployments

• 2 min • 0,5 min • 2 min • 2 min • 10 min • 10 min • Length depending


on image

• With parallelism, in less than 30 minutes, rack is ready for cloud installation
• Mostly automated, few manual steps, less errors
• Manual deployment would easily be a full-day task

20 ©©
Nokia
20172017
Nokia
Nokia AirFrame and Mika concept
Applying a digital assistant to data center management

21 © Nokia 2018
Technology evolution plan
Compute Storage and networking Power, cooling and
mechanics
Ultra-high density compute High density JBOD solution Neutral heat emission solution
• Up to 96 servers in one rack, 50kW • 45 hot swappable drives in 2OU • Rear-door cooler
power
Compact OpenRack
Single-socket edge servers NVME over fabric • ¾ Height OpenRack
• For high IO & small memory
requirements (e.g. edge dataplane • Sharing centralised NVME
resources over Ethernet Legacy telco site support
applications)
• -48V power feed
• Subchassis structure (19”/21”)
• Intel XEON / AMD EPYC
200/400G Networking High Voltage DC power feed
• 400VDC
Ice Lake servers with NVDIMM
• Half-width servers 1OU and 2OU Acceleration options
• Up to 64 servers in one rack 48V rack power distribution
• Power utilization optimization • PCIe Turbo FPGA acceleration • Enabler for higher power ratings
• High performance fans per rack
• PCIe / iNIC IPSEC acceleration
• TDP up to 215W / CPU
• Up to 75W PCIe card Open Rack v2 seismic zone 4
• Seismic kit as an option
22 © 2017 Nokia
23 © Nokia 2018
AirFrame powering both telco and IT / Enterprise use cases
80 AirFrame commercial customers

5
3 7
2 2
3 2
2

2
AirFrame Rackmount
AirFrame OpenRack
AirFrame non-cloud
OpenRack trials
Public references

24 © Nokia 2018