Inlets:

PVP Inlet (PVG32/PVG16) – with maximum possible entries

01 PVPC 02 PVP/PVPM 03 04 PVPX


05 PVLP 06 Pressure1 07 08
09 10 11 12

PVP Inlet (PVG100) – with maximum possible entries

01 PVPC 02 PVP 03 PVPE/PVPD 04


05 06 Pressure1 07 08 PVPP
09 10 11 12

PVP Inlet (PVG120) – with maximum possible entries

01 02 PVP 03 PVPD/ PVPE/ PVPH 04


05 06 Pressure1 07 08
09 10 11 12

PVP Inlet (PVG20) – with maximum possible entries

01 02 PVP 03 04
05 PVLP20 06 Pressure1 07 08
09 10 11 12

PVP Inlet (PVG128/PVG256) – with maximum possible entries

01 02 PVP 03 04 PVPX
05 PVLP 06 Pressure1 07 08 PVPP
09 PVLP 10 11 12

EVP Inlet (ECO80) – with maximum possible entries

01 02 EVP 03 04 EVPX
05 06 Pressure1 07 08
09 10 11 12

Work Sections:
PVB32 Work – with maximum possible entries

PVE / PVHC /
PVE / PVHC / PVCover or
01 PVCover or 02 PVB / PVBZ 03 PVBS 04
PVM
PVM
05 PVLP or PVLA 06 LSa pressure 07 LSb pressure 08 PVLP or PVLA
09 PVDI 10 PVBD/ Multivalve 11 12 PVDI

PVB16 Work – with maximum possible entries

01 PVM 02 PVB16 03 PVBS16 04 PVE / PVHC / PVCover


05 PVLP or PVLA 06 07 LSab pressure 08 PVLP or PVLA
09 10 11 12

PVB100 work – with maximum possible entries

PVE / PVHC /
PVE / PVHC / PVCover or
01 PVCover or 02 PVB100 03 PVBS100 04
PVM
PVM
05 PVLP or PVLA 06 LSa pressure 07 LSb pressure 08 PVLP or PVLA
09 PVLP or PVLA 10 11 12 PVLP or PVLA
PVB120 Work – with maximum possible entries

01 PVM 02 PVB120 03 PVBS120 04 PVE / PVHC/ PVCover


05 PVLP or PVLA 06 LSa pressure 07 LSb/LSab pressure 08 PVLP or PVLA
09 10 11 Accessory Module 12

PVB20 Work – with maximum possible entries

01 PVM or PVML 02 PVB20 03 PVBS20 04 PVE / PVHC


05 PVLP or PVLA 06 LSa pressure 07 LSb pressure 08 PVLP or PVLA
09 10 11 12

PVB128 Work – with maximum possible entries

01 PVM 02 PVB128 03 PVBS128 04 PVE / PVHC / PVCover


05 PVLP or PVLA 06 LSa pressure 07 LSb pressure 08 PVLP or PVLA
09 PVLP or PVLA 10 11 12 PVLP or PVLA

PVB256 Work – with maximum possible entries

01 PVM 02 PVB256 03 PVBS256 04 PVE / PVHC / PVCover


05 PVLP or PVLA 06 LSa pressure 07 LSb pressure 08 PVLP or PVLA
09 PVLP or PVLA 10 11 12 PVLP or PVLA
13 PVLP or PVLA 14 15 16 PVLP or PVLA

EVB80 Work – with maximum possible entries

EVOS/EVM/EVME/ EVOS/EVM/EVME/EVH/
01 02 EVB 03 EVBS 04
EVH/ EVHC EVHC
05 PVLP or PVLA 06 07 08 PVLP or PVLA
09 10 11 Spool Accessory 12

Tank Modules:
PVT Tank (PVG100) – with maximum possible entries

01 02 PVT 03 04
05 PVLP or PVLA 06 07 08
09 10 11 12

PVT Tank (PVG120) – with maximum possible entries

01 02 PVT Upper Part 03 PVT Lower Part 04


05 06 07 08
09 10 11 12
Interfaces:
PVTI 100/32 Interface (PVG100) – with maximum possible entries

01 02 PVTI 03 04
05 PVLP or PVLA 06 07 08
09 10 11 12

PVGI (PVG128 / PVG256) – with maximum possible entries

01 02 PVGI 03 04
05 06 07 08
09 10 11 12

PVGI (PVG120) – with maximum possible entries

01 02 PVGI 03 PVT Lower Part 04


05 06 07 08
09 10 11 12

End Sections:
PVS End (PVG32/PVG16) – with maximum possible entries

01 02 PVS / EHPS 03 04
05 06 07 08
09 10 11 12

PVSI (PVG128 / PVG256) – with maximum possible entries

01 02 PVSI 03 04
05 06 07 08
09 10 11 12

EVO End (ECO80) – with maximum possible entries

01 02 EVO 03 04
05 06 07 08
09 10 11 12

Special Modules:
PVSK (PVG32/PVG16) – with maximum possible entries

PVE / PVHC / PVM PVE / PVHC / PVM /


01 02 PVSK/PVSKM 03 PVSKS (Spool) 04
/ PVCover PVCover
05 06 07 08
09 10 11 12

PVSP (PVG32/16) – with maximum possible entries

01 02 PVSP / PVSPM 03 PVSPC 04


05 PVLP / PVLA 06 Relief pressure 07 08
09 10 11 12

HIC – with maximum possible entries

01 02 HIC 03 04
05 PVLP / PVLA 06 07 08
09 10 11 12
PVAS/EVT (Field 18):
None-Combo (PVG32/16)
18 PVAS 1. PVAS / EVT 2. 3.

Non-Combo (PVG256/128)
PVAS PVAS
18 PVAS 1.
PVG256/128
2.
PVG256/128
3.

Combo (PVG256/128)
PVAS PVAS
18 PVAS 1.
PVG256/128
2.
PVG32/16
3.

Combo (PVG120)
PVAS
18 PVAS 1. PVAS PVG120 2.
PVG32/16
3.

Combo (PVG100)
PVAS
18 PVAS 1. PVAS PVG100 2.
PVG32/16
3.

Painting (Field 19):


Painting Material
19 Painting
Number

Customer Labels (Field 20+21)


If the customer wants to have their own text on the label, this can be done by specifying the text in fields 18 and/or 19. Max length is 13
characters, and no special characters.

Customer text on the product-label placed on the valve itself (this will replace the text PVG above the PVG number)
20 Customer Text on Group Label

Customer text on the shipping-label put on the cardboard-box, that the PVG is transported in
21 Customer Text on Packaging Label (Box)

Header of Specification:
Subsidiary / Dealer Specify when possible. Should be filled out with the same syntax as Customer
Customer Specify the customer
Application Specify the application
Danfoss Sold-To Party No. Specify all Sold-To’s that should be able to purchase this group. Separate by comma.
PVG No. Filled out by OFR
Customer Part No. Specify if relevant, maximum of 30 characters.
Revision No. Specify if relevant

Function of each Work Section:


Function of each section is optional for sections without software settings.
For sections with software settings the function fields are mandatory.

Other:
Comments can be written in the empty field in the header or at the bottom of the specification.