ALARM SYSTEMS

CONTENTS

Alarm Systems

Chapter 20.1

DESCRIPTION................................................................................... 20.1-1
BASIC ALARM SYSTEM INTERCONNECTION DIAGRAMS . 20.1-2
Basic Alarm System - Without Alarm Status................................. 20.1-2
Basic Alarm System - With Alarm Status...................................... 20.1-3
ENHANCED ALARM SYSTEM INTERCONNECTION
DIAGRAMS ..................................................................................... 20.1-4
Enhanced Alarm System - Without Status ..................................... 20.1-4
Enhanced Alarm System - With Alarm Status............................... 20.1-5
Enhanced Alarm System for Medium/High
Security Interconnection Diagram ................................................. 20.1-6

STRAPPING ....................................................................................... 20.1-7

TEST TOOLS ..................................................................................... 20.1-7

ADJUSTMENTS ................................................................................ 20.1-7

INTERNAL CABLES ........................................................................ 20.1-8


ALARMS OUTPUT CONNECTOR ............................................... 20.1-8
SECURITY ENCLOSURE DOOR SWITCH HARNESS -
BASIC AND ENHANCED.............................................................. 20.1-9
SECURITY ENCLOSURE DOOR SWITCH HARNESS -
ENHANCED FOR MEDIUM/HIGH SECURITY .......................... 20.1-9
VIBRATION SENSOR HARNESS................................................. 20.1-9
COMPOSITE ALARM HARNESS ............................................... 20.1-10
Harness for Cerberus Unit 009-0005020 ..................................... 20.1-10
Harness for Seismic Detector 009-0010985................................. 20.1-10
Harness for Seismic Detector 009-0011573................................. 20.1-11
Harness for Seismic Detector 009-0022894................................. 20.1-11
SILENT ALARM HARNESS........................................................ 20.1-12
NCR — CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
JUNE 2008 20.1-i
ALARM SYSTEMS

TROUBLESHOOTING INFO ..........................................................20.1-12

CONNECTOR ASSIGNMENT........................................................20.1-13
ALARM TERMINATION PANEL - BASIC
WITHOUT STATUS ......................................................................20.1-13
Silent Alarm Connector, J1...........................................................20.1-13
Door Switch Connector, J2...........................................................20.1-13
Alarm Output Connector, J3.........................................................20.1-13
Vibration Sensor Connector, J4 ...................................................20.1-14
ALARM TERMINATION PANEL - BASIC WITH STATUS .....20.1-14
Silent Alarm Connector, J1...........................................................20.1-14
Door Switch Connector, J2...........................................................20.1-14
Alarm Output Connector, J3.........................................................20.1-15
Vibration Sensor Connector, J4 ....................................................20.1-15
ALARM TERMINATION PANEL - ENHANCED
WITHOUT STATUS ......................................................................20.1-16
Silent Alarm Connector, J1...........................................................20.1-16
Door Switch Connector, J2...........................................................20.1-16
Alarm Output Connector, J3.........................................................20.1-16
Composite Attack Connector, J4 ..................................................20.1-17
ALARM TERMINATION PANEL - ENHANCED
WITH STATUS ..............................................................................20.1-17
Silent Alarm Connector, J1...........................................................20.1-17
Door Switch Connector, J2...........................................................20.1-17
Alarm Output Connector, J3.........................................................20.1-18
Composite Attack Connector, J4 ..................................................20.1-18
I/O PANEL ALARM OUTPUT CONNECTOR............................20.1-19

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-ii JUNE 2008
ALARM SYSTEMS

CONTENTS

Chapter 20.1

Alarm Systems

DESCRIPTION
The alarm system provides an interface between a series of alarm
sensors and an external environment, such as a Bank’s existing
alarm scheme.
There are three types of alarm systems:
z Basic
z Enhanced
z Enhanced for medium/high security.
For the first two systems there is a further option of status
reporting. This feature reports the status of the alarm signals to the
ATM application program. The enhanced alarm system for medium/
high security is supplied with status reporting as standard.
A silent alarm, operated by a special combination lock, is an
option with the basic and enhanced systems.
If the silent alarm is not fitted, the following turnaround plug
(NCR part number 445-0591539) will be installed in connector J1
on the alarm termination panel:
z 1 x 009-0006439, connector 2 x 3 plug
z 2 x 009-0006427, terminal #18 (female)
z 50 mm x 006-5830020, wire #18 white.

6 5 4

3 2 1

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-1
ALARM SYSTEMS

BASIC ALARM SYSTEM INTERCONNECTION DIAGRAMS

Basic Alarm System - Without Alarm Status


The following block diagram shows the signal paths in the basic
alarm system without alarm status:

NOTE: * Fitted with the turnaround plug if the silent alarm is not
present.

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-2 JUNE 2008
ALARM SYSTEMS

Basic Alarm System - With Alarm Status


The following block diagram shows the signal paths in the basic
alarm system with alarm status:

NOTE: * Fitted with the turnaround plug if the silent alarm is not
present.
NCR — CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
JUNE 2008 20.1-3
ALARM SYSTEMS

ENHANCED ALARM SYSTEM INTERCONNECTION


DIAGRAMS

Enhanced Alarm System - Without Status


The following block diagram shows the signal paths in the
enhanced alarm system without alarm status:

NOTE: *Fitted with the turnaround plug if the silent alarm is not
present.

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-4 JUNE 2008
ALARM SYSTEMS

Enhanced Alarm System - With Alarm Status


The following block diagram shows the signal paths in the
enhanced alarm system with alarm status:

NOTE: * Fitted with the turnaround plug if the silent alarm is not
present.
NCR — CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
JUNE 2008 20.1-5
ALARM SYSTEMS

Enhanced Alarm System for Medium/High


Security Interconnection Diagram
The following block diagram shows the signal paths in the
enhanced alarm system for medium/high security:

NOTE: * The turnaround plug is always fitted on this alarm sys-


tem.

NOTE: ** This diagram shows the original Cerberus Unit, see


details of subsequent seismic detectors starting at page 20.10.
NCR — CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
20.1-6 JUNE 2008
ALARM SYSTEMS

STRAPPING
None.

TEST TOOLS
A spring gauge (Chatillon, NCR part number 603-9000057 or an
equivalent) is required for the vibration detector adjustment
procedure.

ADJUSTMENTS
The vibration detector will normally be adjusted for optimum
performance by the representative of the alarm company
responsible for connecting the ATM to a local alarm system (they
have the expertise and local knowledge to adjust the unit for a
particular site). For test purposes, however, NCR presets the unit to
an initial adjustment as follows:

z Using a spring gauge, centred level with the contact in the


direction of the arrow, adjust the screw until the force necessary
to open the contact is approximately 5 g. Recommended range
is 5 g minimum to 25 g maximum.
z If a gauge is not available an approximate adjustment can be
made as follows:
z Loosen the adjustment screw until the contact is open
z Tighten the screw until the contact is just closed
z Tighten the screw a further one eighth (1/8) of a turn. (This
is the equivalent of the 5 g setting.)

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-7
ALARM SYSTEMS

INTERNAL CABLES

ALARMS OUTPUT CONNECTOR

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-8 JUNE 2008
ALARM SYSTEMS

SECURITY ENCLOSURE DOOR SWITCH HARNESS -


BASIC AND ENHANCED

SECURITY ENCLOSURE DOOR SWITCH HARNESS -


ENHANCED FOR MEDIUM/HIGH SECURITY

VIBRATION SENSOR HARNESS

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-9
ALARM SYSTEMS

COMPOSITE ALARM HARNESS

Harness for Cerberus Unit 009-0005020

+ 12V_RTN
+ 12V_RTN

Harness for Seismic Detector 009-0010985


Production of the Cerberus unit 009-0005020 and associated test
transmitter ceased in 1995. The replacement seismic detector 009-
0010985 and test transmitter 009-0010986 are connected as shown
below:

Terminal
strip
2
9
Seismic Detector 009-0010985

3
7
14
11
10
1

15

009-0010986

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-10 JUNE 2008
ALARM SYSTEMS

Harness for Seismic Detector 009-0011573


Production of the seismic detector 009-0010985 ceased in 1997. The
test transmitter 009-0010986 is still used. The replacement seismic
detector 009-0011573 is connected to the test transmitter 009-
0010986 as shown below:

Terminal
strip
2
9

Seismic Detector 009-0011573


15
14
11
10

009-0010986

Harness for Seismic Detector 009-0022894


Production of the seismic detector 009-0011573 ceased in 2006. The
test transmitter 009-0010986 is still used. The replacement seismic
detector 009-0022894 is connected to the test transmitter 009-
0010986 as shown below:

Terminal
strip
2
9
Seismic Detector 009-0022984

15
14
11
10

009-0010986

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-11
ALARM SYSTEMS

SILENT ALARM HARNESS

TROUBLESHOOTING INFO
None.

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-12 JUNE 2008
ALARM SYSTEMS

CONNECTOR ASSIGNMENT

NOTE: The connector assignment for the enhanced alarm system


for medium/high security is the same as the enhanced with sta-
tus alarm system.

ALARM TERMINATION PANEL - BASIC WITHOUT STATUS

Silent Alarm Connector, J1

N/C 4 1 N/C
SAL_CM 5 2 N/C
SAL_NO 6 3 SAL_NC

Door Switch Connector, J2

DAL_CM 3 1 N/C
DAL_NC 4 2 DAL_NO

Alarm Output Connector, J3

N/C 1 2 DAL_NO
N/C 3 4 DAL_CM
N/C 5 6 DAL_NC
N/C 7 8 SAL_NO
N/C 9 10 SAL_CM
N/C 11 12 SAL_NC
N/C 13 14 CAL_NC
N/C 15 16 CAL_CM
N/C 17 18 N/C
N/C 19 20 N/C
N/C 21 22 N/C
N/C 23 24 N/C
N/C 25 26 N/C
N/C 27 28 N/C
N/C 29 30 N/C

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-13
ALARM SYSTEMS

Vibration Sensor Connector, J4

N/C 1 2 N/C
N/C 3 4 N/C
N/C 5 6 N/C
N/C 7 8 N/C
N/C 9 10 N/C
VIB+HEAT 11 12 N/C
N/C 13 14 N/C
N/C 15 16 CAL_CM

ALARM TERMINATION PANEL - BASIC WITH STATUS

Silent Alarm Connector, J1

N/C 4 1 N/C
+12V 5 2 N/C
N/C 6 3 SREL

Door Switch Connector, J2

+12V 3 1 N/C
DREL 4 2 N/C

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-14 JUNE 2008
ALARM SYSTEMS

Alarm Output Connector, J3

TAL_NC 1 2 DAL_NO
TAL_CM 3 4 DAL_CM
N/C 5 6 DAL_NC
N/C 7 8 SAL_NO
N/C 9 10 SAL_CM
N/C 11 12 SAL_NC
N/C 13 14 CAL_NC
CSTS_CM 15 16 CAL_CM
DSTS_CM 17 18 CAL_NO
SSTS_CM 19 20 CSTS_NC
TSTS_CM 21 22 DSTS_NC
N/C 23 24 SSTS_NC
N/C 25 26 TSTS_NC
N/C 27 28 +12V
GND 29 30 N/C

Vibration Sensor Connector, J4

N/C 1 2 N/C
N/C 3 4 N/C
N/C 5 6 N/C
N/C 7 8 N/C
N/C 9 10 N/C
VIB 11 12 N/C
N/C 13 14 N/C
N/C 15 16 GND

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-15
ALARM SYSTEMS

ALARM TERMINATION PANEL - ENHANCED WITHOUT


STATUS

Silent Alarm Connector, J1

N/C 4 1 N/C
SAL_CM 5 2 N/C
SAL_NO 6 3 SAL_NC

Door Switch Connector, J2

DAL_CM 3 1 N/C
DAL_NC 4 2 DAL_NO

Alarm Output Connector, J3

TAL_NC 1 2 DAL_NO
TAL_CM 3 4 DAL_CM
TAL_NO 5 6 DAL_NC
TAL_OUT 7 8 SAL_NO
TAL_IN 9 10 SAL_CM
N/C 11 12 SAL_NC
N/C 13 14 CAL_NC
CSTS_CM 15 16 CAL_CM
DSTS_CM 17 18 CAL_NO
SSTS_CM 19 20 CSTS_CN
TSTS_CM 21 22 DSTS_CN
CTST_OP 23 24 SSTS_NC
CTST_OUT 25 26 TSTS_NC
CTST_IN 27 28 +12V
GND 29 30 N/C

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-16 JUNE 2008
ALARM SYSTEMS

Composite Attack Connector, J4

N/C 1 2 +12V
N/C 3 4 N/C
N/C 5 6 CTST_OP
N/C 7 8 CTST_OUT
N/C 9 10 CTST_IN
N/C 11 12 CAL_NC
TAL_OUT 13 14 N/C
TAL_CM 15 16 GND

ALARM TERMINATION PANEL - ENHANCED WITH STATUS

Silent Alarm Connector, J1

N/C 4 1 N/C
+12V 5 2 N/C
N/C 6 3 SREL

Door Switch Connector, J2

+12V 3 1 N/C
DREL 4 2 N/C

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-17
ALARM SYSTEMS

Alarm Output Connector, J3

TAL_NC 1 2 DAL_NO
TAL_CM 3 4 DAL_CM
TAL_NO 5 6 DAL_NC
TAL_OUT 7 8 SAL_NO
TAL_IN 9 10 SAL_CM
N/C 11 12 SAL_NC
N/C 13 14 CAL_NC
CSTS_CM 15 16 CAL_CM
DSTS_CM 17 18 CAL_NO
SSTS_CM 19 20 CSTS_NC
TSTS_CM 21 22 DSTS_NC
CTST_OP 23 24 SSTS_NC
CTST_OUT 25 26 TSTS_NC
CTST_IN 27 28 +12V
GND 29 30 N/C

Composite Attack Connector, J4

N/C 1 2 +12V
N/C 3 4 N/C
N/C 5 6 CTST_OP
N/C 7 8 CTST_OUT
N/C 9 10 CTST_IN
N/C 11 12 CAL_OUT
TAL_OUT 13 14 N/C
GND 15 16 GND

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-18 JUNE 2008
ALARM SYSTEMS

I/O PANEL ALARM OUTPUT CONNECTOR


The alarm output connector, located on the ATM I/O connector
panel, has the following arrangement of pins which are allocated for
basic and enhanced systems as shown in the diagram:

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
JUNE 2008 20.1-19
ALARM SYSTEMS

NCR — CONFIDENTIAL AND PROPRIETARY


Use pursuant to Company Instructions
20.1-20 JUNE 2008