1.2 DATABASE
1.2.1 FILE EXPORT
1.2.2 FILE IMPORT
1.2.3 CREATE VERSION
1.2.3 LOAD VERSION
1.2.4 DATABASE VALIDATION
1.2.5 DATABASE MANAGEMENT
1.4 CONFIGURATION
1.4.1 GENERAL CONFIGURATION
1.4.2 OBJECT
1.4.3 ALARM TYPE
1.4.4 DIGITAL TYPE
1.4.5 FLAGS
1.4.6 PLANT PARTITIONING
1.6 OBJECT
1.6.2 DIGITAL TEXT
1.6.3 ANALOG TEXT
1.7 SYSTEM
1.7.1 SYSTEM OVERVIEW
1.7.2 USER MANAGEMENT
1.7.3 USER CONFIGURATION
1.7.4 USER RIGHT
1.4.3. Configuration
Manages the General configuration settings for the system. The configuration setting
defined under this Menu Item are global and is applicable to the entire Project.
General Configuration: Configures the TOP Banner as to be displayed in
HMI.
Objects: Define the Global setting for the system objects:
o Alarms Types
o Digital Types
o Flags
o Plant Partitioning
1.4.5. Object
Under this Menu Item user defines all the information for configuration of the SCADA
Tags (both physical and software tags). All system information in the form of I/O
Tags (Digital / Analog) and its association with Alarm / Events / History can be
configured in this section.
Digital Text: Define the template for the Alarm text for Digital Input points
according the Tag value and quality.
Analog Text: Define the template for the Alarm text for Analog Input points
according the Tag value and quality.
Alarm Standard: Define the Alarm condition association with Tag and
association with History / Event Log.
Digital Output Command Standard: Define the template for handling of the
digital output tags and the relationship between the raw and engineering
values.
Digital Output Reply Standard: Define the template for handling of the
digital output command and association is Digital Input response.
Define the interlock conditions and its association / logics with I/O Tags
Physical Analog Input: Define the Analog Input Tags which are to be
acquired through communication channels.
Physical Analog Output: Define the Analog Output Tags which are used to
for control through communication channels.
Physical Digital Input: Define the Digital Input Tags which are to be
acquired through communication channels.
Physical Digital Output: Define the Digital Output Tags which are used to
for control through communication channels.
Functional Software Analog Input: Define the Analog Input Tags which are
to be managed internally by SCADA software logical implementations or
by user actions.
Functional Software Digital Input: Define the Digital Input Tags which are
to be managed internally by SCADA software logical implementations or
by user actions.
1) I/O List
2) Interlock Conditions
3) HMI Views
This option is used to export the file of EWS. The exported file is saved with the
extension (.ews)
Click Browse button .
Enter the name of the file to be saved.
Click on save option and than click on OK.
File import option import any file with extension (.ews) to EWS software. This
is shown in above view.
SOUND UPLOAD: The following menu item is used to upload required sound
in the SCADA configuration. Followings are the steps to upload the sound file:-
Select the sound file and click open button. Sound id must be provided to
upload sound file.
Press upload button to add sound file in the list.
In order to update the added file, select the file from the list.
Use Update Selected button to update the selected file.
Use Delete Selected button to delete the added file
IMAGE UPLOAD: The following menu item is used to upload required image
in the SCADA configuration. Followings are the steps to upload the image file:-
Select the image file and click open button. Image id must be provided to
upload image. Press upload button to add image in the list.
In order to update the added file, select the file from the list.
Use Update Selected button to update the selected file.
Use Delete Selected button to delete the added file.
In general configuration buttons for local mode and remote mode are
designed.
If user wants to send command from control room then plant should be
set in remote mode by pressing remote mode button and if user wants to
change manually from plant then local mode is set.
When local mode is set then command can’t be sent from the control
room. To send the command from the control room it has to set in remote
mode.
DIGITAL TYPES: Digital type describes numbers of states for Digital Input or
Digital Output.
Single DI can have two states i.e. 0-1
Double DI can have four states i.e. 0-3
FLAGS:
MAIN MENU DESIGN: In main menu design we design our main menu
display.
In view management we design side menu buttons that are to be displayed in the
HMI view.
The button which is selected from the view list is to be focused in the side menu
list.
Up till now we have made buttons for our HMI view but which button is linked
to which view (as partition list is made) that is decided in menu action.
It is used to see all the previous alarm in a single view or page by page. Pages
are displayed on the basis of Time, Date and Year.
Custom view dialog can be designed using the nine general shapes . Step to
design a custom shape are as the following:
1. Click on the text (Aa) on the right corner of custom shape menu. Rectangle
shape box for writing text will appear in designing window.
2. Text property windows will appear below designing window. Set different
properties as per the design requirement.
3. Set coordinates and Press update button to save the changes.
For the user to define the custom shape property option is given.
ELEMENTS:
The option element is used to design the different states of custom shapes like
as shown in the above view.
Name: Enter the view element name.
Custom Shapes: Select the shape from the list.
ID: Enter the ID number for the selected custom shape.
Click on the add button.
Queue all the similar custom shapes with different ID no. under the same
Element name.
ELEMENT PROPERTY:
Element Property list: Select the element property from the list.
Object type: Select the digital type (Physical/Software/All digital)
Plant Partition List: Select the plant name linked to that specific element
property.
Object List: Select the object from the list which corresponds to both element
property and plant partition.
OBJECT TEXT:
Enter the values for the width and height required for the HMI views.
HMI view which is visible to user is designed in Design View GUI. Using
various shapes given in right side and by using custom shapes or elements made
before is used for making views.
1. Select shape form the right hand side menu for e.g. select rectangle.
2. Set X and Y parameters to place rectangle on the screen.
3. Press update button.
SELECTION MENU:
Circuit Title: - Choose the circuit title or plant partition from the list and
associate it with its view id. All the inputs belong to this partition would be
displayed in this view.
Rows per page: Number of Rows that are to be displayed in the event view.
The user can set maximum of 500 rows per page.
History view GUI displays the history log of respective plant partition.
Rows per page: Number of Rows that are to be displayed in the history view
dialog. The user can set maximum of 500 rows per page.
Device status GUI graphically displays list of filtered inputs with their current
status with respect to plant partition. The dialog is providing with list of part
partition and for options to filter inputs accordingly.
Circuit title: Choose the circuit title from the list and associate it with its view
id.
DIGITAL TEXTS:
Digital text represents the current status of digital Input (Physical or Software)
ANALOG TEXTS:
ALARM STANDARDS:
When the control of one object is dependant on the other interlocking conditions
are set.
Name: Enter the view object name for the physical input.
Max & Min value: Enter correspond minimum value and maximum value for
analog input.
Recordable: Values coming from the site are visible to user and stored in the
database if ‘Yes’ option is selected.
Click on the add button so that it can be listed.
Name: Enter the view object name for the physical output.
Max & Min value: Enter correspond minimum value and maximum value for
analog output.
Name: Enter the view object name for the physical digital input.
Circuit Title List: Select the name of the plant from the list.
Digital text: Select the digital text from the list.
Alarm Standard: Select the alarm corresponds to digital text.
Digital type: Select the digital type from the list.
Physical digital output is the output sent to field by the user through HMI.
Name: Enter the view object name for the physical digital output.
Interlock Standard: Select the corresponding interlock standard from the list.
Name: Enter the view object name for the software analog input.
Recordable: Values coming from the site are visible to user and stored in the
database if ‘Yes’ option is selected.
Max & Min value: Enter correspond minimum value and maximum value for
software analog input.
Action: Select the option to set value or the flag.
Name: Enter the view object name for the software analog input.
Partition Plant: Select the plant from the list.
Action: Select the option to set value or the flag.
Alarm Standard: Select the corresponding alarm standard.
Parameters List: Select the name of the parameter from the list as made in
function list.
Object Type: Select the object type from the list.
Circuit Title List: Select the plant from the list.
Object List: Select with object correspond to object type and the plant.
Click on the update button and than on the Select/update function linking.
After creating the software objects we have to link the proper specified object to
function list and the input parameters within the specified circuit title.
It is used to link the digital output object to digital output standard for the
purpose of acknowledgement of the digital output.
USER MANAGEMENT: In this dialog rights are to the user for accessing the
HMI view.
B) USER RIGHTS:
PROTOCOL CONFIGURATION:
a) SERIAL PORTS
d) AI ACQUISITION
f) DI CONFIGURATION:
g) AI CONFIGURATION:
k) AO CONFIGURATION:
SUPERVISORY SETTINGS: