You are on page 1of 62

NPSH IN FEET

110
250mm IMPELLER DIAMETER 9 13/16"
45
100 50
245
HE
AD
CA
40 240 PA
90 CIT
Y

5H
235

P
35 80 230 40

7.5
225
220

HP
215
3H

30 70
210
P

205
200
60 30
25

50

FP FPX FPR

Sanitary Centrifugal Pumps


Performance Curves
Table of Contents
Introduction.........................................................................................................................2

Pump basics..........................................................................................................................4

Selecting a pump..................................................................................................................5

Pump inquiries application data sheet................................................................................7

How to calculate required pressure.....................................................................................8

Determining net positive suction head (NPSH)..................................................................8

Specific gravity and viscosity chart......................................................................................9

Conversion factors..............................................................................................................10

Vapor pressure chart..........................................................................................................10

Tubing friction loss chart...................................................................................................11

Fristam centrifugal pump options.....................................................................................12

Pump Performance Curves: 1750 RPM Pump Performance Curves: 3500 RPM
FP/FPX Composites...................... 14 FP/FPX Composite........................ 35
FPR Composites............................ 16 FPR Composites............................ 36
701 ................................................ 18 702 ................................................ 38
711 ................................................ 19 712 ................................................ 39
721 ................................................ 20 722 ................................................ 40
3521............................................... 21 3522............................................... 41
731 ................................................ 22 732 ................................................ 42
3531............................................... 23 1732............................................... 43
741 ................................................ 24 3532............................................... 44
1741............................................... 25 742 ................................................ 45
3541............................................... 26 1742............................................... 47
751 ................................................ 27 3542............................................... 49
3451............................................... 28 752 ................................................ 50
3551............................................... 29 3452............................................... 51
1051............................................... 30 3552............................................... 52
1151............................................... 31
1161............................................... 32
4001............................................... 34

Dimensional Drawings
FP Single Flange..........................................................................................................54
FP Double Flange.........................................................................................................55
FPX Single Flange........................................................................................................56
FPX Double Flange......................................................................................................57
FPR Single Flange........................................................................................................58
FPR Double Flange......................................................................................................59
FPR 4001......................................................................................................................60

1
Fristam Pride
Fristam is a global manufacturer of sanitary centrifugal and positive displacement pumps,
mixers and blenders respected for unmatched performance, reliability, and technical superiority.

Fristam manufactured its first pump in 1931. Today, Fristam equipment is used by many of the
world’s top dairy, beverage, brewing, bio-pharmaceutical, and food processing companies.

High Lifetime Value


The solid design, precise machining, and robust construction of a
Fristam pump ensures efficiency and operational reliability. Fristam
pumps simply run better and last longer.

Quality Control
Fristam Pumps USA designs, manufactures, and assembles its pumps
in the United States. Each component is carefully checked from raw
material through final assembly.

The result of this effort is a pump worthy of the valuable product your
company produces. To achieve the highest level of quality, Fristam offers
the most comprehensive testing and documentation packages in the
sanitary pump industry.

2
Experience and Expertise
Over the past 100 years, Fristam has built its reputation with experience, attention
to detail, and a willingness to adapt to changing needs. Fristam’s strong applications
engineering capabilities make it the most reliable source for straight, smart answers to
process needs.

Fast Delivery, New Solutions


Manufacturing in the United States ensures Fristam customers
receive prompt delivery, not lead times measured in months.

Additionally, if a new production challenge arises, Fristam is


responsive and able to develop new solutions quickly.

Dedicated Support
Fristam’s dedication and quality service do not end with your initial
purchase. An international network of manufacturing facilities, sales
offices and distribution supports Fristam’s commitment to customer
satisfaction.

Why Customers Choose Fristam


“simply better pumps”
“reliable, dependable”
“high standard for sanitization and performance”
“knowledgeable people who help solve problems”

3
Pump Basics: Background Information
Pump Series – FP, FPX, or FPR
The FP, FPX, and FPR Series pumps are manufactured
of 316L stainless steel and have the same pump head.
The FP incorporates a heavy-duty pedestal flange between the

22
2
72

35
motor and pump head. The FPX is a motor mounted pump

PRESSURE
used for standard duties. The FPR has a front-loading seal for
easy changeout and may be used in place of either the FP or
FPX. Double seals are only available in the FP and FPR. The
FP is used for vacuum withdrawal, high temperature, high
viscosity, aseptic processes and

FPR 3522
FPR 722
other demanding applications.

Pump Model/Housing Size


Fristam offers both volute and non-volute (circular) housings
in many sizes to best match different process needs. The
700 and 1700 series pumps are non-volute and designed
VOLUME
for lower capacities. Their shorter, steeper curves provide
better efficiencies on low flows and superior accuracy when
used with control devices. The 1050, 1150, 3400 and 3500 Figure 1
series pumps are volute high capacity pumps. Their long, Horsepower
flat curves provide greater capacity and an ability to provide Horsepower must be matched to a given duty or duties. The
steady discharge pressure over a wide flow range. requirements are determined by individual curves. Enough
horsepower must be supplied to handle the most demanding
Speed duty, often the duty requiring the most flow, pressure or the
Pumps are sized using two standard speeds, 1750 and pumping of the heaviest product.
3500 RPM. Speed selection is determined when selecting
a housing. The last digit of the Fristam model number Net Positive Suction Head (NPSH)
003.p3 fig.1
indicates the speed. All models ending in 1 are 1750 RPM. All Product must be forced into a centrifugal pump for it to
models ending in 2 are 3500 RPM. function properly. This force is called NPSH. Your process
must have sufficient NPSH available to meet or exceed the
Efficiency NPSH required.
The efficiency of centrifugal pumps varies over the individual
curve. The most efficient point of two curves is illustrated in Seals
Figure 1. When sizing, it is helpful to select a pump whose Fristam offers a wide selection of seals. Most processes
curve puts the duty point as close to this bend in the curve require a standard single seal of chrome oxide coated
as possible. stainless steel on carbon. More difficult applications will
require harder seal materials such as silicon carbide.
Impeller Size Double seals are used when a flush is required, where
Within a given housing, the impeller diameter will determine abrasion or stickiness is a problem, for vacuum withdrawal
the flow and pressure produced. Pressure results from the or if a sterile barrier is required between the process
velocity achieved within the pump. The highest velocity and atmosphere.
occurs at the tip of the impeller and is directly proportional
to the square of the impeller diameter. At a given speed,
a larger diameter impeller will impart more velocity and
produce more pressure.
4
Selecting a Fristam Pump: A Step by Step Guide
Special Considerations Example
All curves are based on 70°F water. If your process involves As an example, size a pump to pump 50 gallons per minute
products under vacuum, with high viscosity, high specific and generate 135 feet of head. In the composite shown
gravity, high temperatures, undissolved solids or entrained in Figure 2, find the intersection point of 50 GPM on the
air there are special considerations which affect pump bottom of the graph and 135 feet on the side. The pump
selection. In such cases, please consult Fristam Pumps or curve directly above the duty point is the 722. In this
your local Fristam distributor. example, model 742 (the next size larger) might also be
considered. A quick review of the duty point on their
Selecting a Pump Model From the individual curves reveals the 722 will be more efficient than
the 742.
Composite Curves
Composite curves appear at the beginnings of the low- and
high-speed sections. To select the correct pump model Considering Speed and Efficiency
from the composite curves, find the desired flow rate along If both pumps are the same speed, consider which will be
the bottom scale and the desired pressure on the left-hand more efficient based on the information discussed in Figure
vertical scale. Find the point where the vertical line from the 1. If both a high and low speed pump can handle the duty,
flow rate and a horizontal line from the pressure intersect. the high speed will generally be more economical, but the
The curve immediately above this point will be most low speed model may have a lower NPSH requirement.
suitable.
Choosing Impeller Size and Horsepower
Figure 2 Having chosen a pump model based
on the first two steps, find the specific
OF HEAD

FPR 3500 RPM Composite Curve curve for the pump model chosen.
FEET
BAR

450
To determine the impeller diameter
13 and horsepower move vertically from
12 400 the flow and horizontally from the
pressure or head desired. Find the
11
350 intersecting point.
10
752
9 300 The next higher curve indicates
8
the correct impeller diameter. The
250 diagonal line immediately to the right
PRESSURE

7
of the intersection identifies the motor
6 200 horsepower required.
742
5
1742
150
4

3 100

2
50 722
1 712
702
0 0
GPM 0 50 100 150 200 250 300 350 400 450

LPM 0 200 400 600 800 1000 1200 1400 1600

CAPACITY 1265000206 Rev. A


RD 2/08

5
Example Seal Selection: Single or Double
Using our previous example of 50 gallons per minute and 135 Many applications require only single seals. Double seals
feet of head, we can determine from Figure 3 that the impeller are recommended for applications involving:
diameter should be 145 millimeters (5.7 inches). The motor • Abrasive products
required is 5 horsepower. • Sticky products
• Vacuum >14” Hg
Checking NPSH (Net Positive Suction Head) • Temperature regulation
To assure there is sufficient product pressure at the inlet of
the pump the suction conditions need to be checked. The Seal Selection: Materials
NPSH required can be determined by finding the point on Recommended seal material configurations:
the individual pump curve where the vertical line from the • Simple transfer applications: FR-N-(K)*
desired flow rate intersects the NPSH curve. From this point, • Sticky applications: FR-C-(N)*
a horizontal line to the right will intersect the NPSH scale at • Pharmaceutical applications, chlorine, brine: C-C-(N)*
the net positive suction head required.* * rotating seal, stationary seal, (flush/double seal)

The procedure for determining the NPSH available is N = Carbon


described in the “How To Calculate Required Pressure” section C = Silicon Carbide
of this book. When the NPSH available is determined, it must FR = Chrome Oxide Coated Stainless Steel
meet or exceed the NPSH required for the pump to function K = Ceramic
properly. If the NPSH available is
insufficient, a change to the inlet Figure 3
HEAD (FT)

conditions, an enlarged inlet or


PSI

another pump selection may be 150

required. 145mm IMPELLER DIAMETER 5 1


1/16"
60 140

140

Example
135
A 722 pumping 50 GPM against 120
50
135 feet of head will require 130

6 feet or more of NPSH. The 125 HE


AD
100
installation must provide at least
CA
120
PA
40
5 HP

6 feet of head.
CIT
7 1/

115
2H
P

80

Elastomers
110
3 HP

30
Viton is the standard seal
2 HP

60
elastomer and BUNA is standard
for the cover gasket. Other
20
materials and combinations 40
are available to meet your
application or process needs.
10
20 10
NPSH IN FEET

NPSH REQUIRED

0 0
0 20 40 60 80 100 120 140 150
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000 70,000 75,000
CAPACITY

*Please note that the NPSH values shown are for full size impellers. Smaller impellers may require somewhat greater NPSH.

6
Pump Inquiry Data Sheet
The following information is required to properly process an inquiry:
Requested by______________________________________________________ Date___________________________________
Customer________________________________________________________________________________________________
Address__________________________________________________________________________________________________
Telephone___________________________________ Fax__________________ Email___________________________________
Description of product to be pumped__________________________________________________________________________
________________________________________________________________________________________________________
Temperature___________ Specific Gravity______________________________ or Density_________________________ lb./gal.
Viscosity____________________________________ Centipoise (CPS) or other
Desired Flow Rate____________________________GPM or lb./hr.
*Discharge Head_____________________________ ft. or PSI

Suction Conditions
Is the pump withdrawing from a vacuum?_________Yes__________No
If so, how much?_____in. Hg.
Is the product level on the inlet side of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. of size of valves in suction piping:
_____________________ No.___________________ Size (in.)
_____________________ No.___________________ Size (in.)
Other equipment in the suction piping________________________________________________________________________
________________________________________________________________________________________________________

*If you do not know the desired discharge head, please provide the following:
Discharge Conditions
Is the final destination of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. and size of valves in discharge piping:
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
Other equipment and the drop or pressure requirement (PSI) in the discharge piping__________________________________
________________________________________________________________________________________________________

7
How To Calculate Required Pressure
Example:
Find the head under these conditions: Pump is drawing
299.2 ft.
from an open tank to discharge through a heat exchanger
into an open tank that is 20 ft. above the pump. The supply
is 8 ft. above the pump. 50 GPM flow is required. Outlet Open Tank
1 1/2" Pipe Water 62

Solution: 20 ft. Tank


Heat
System Head
The total head of a system against
180
1. Height to be pumped is 20 ft. minus 8 ft. =12.0 ft. Exchanger which a pump must operate is made
up of the following components:
Inlet
8 ft. 1 1/2" Pipe 1. Static Head
2. Friction loss from pipe is 2. Difference of pressures
existing on the liquids
(8 ft. + 10 ft. + 20 ft. + 299.2 ft. = 337.2 ft.) 3. Friction
337.2 x .25 ft./ft. =84.3 ft. 10 ft.

3. Friction loss from 3 elbows is = 0.6 ft. = 0.6 ft.

4. *Heat Exchanger loss 2.31 times 16.5 PSI =38.1 ft.

The Total Head Loss is . . . . . . . . . . . . . . . . . . . . 135.0 ft.


*Heat Exchanger information supplied by manufacturer.

Determining Net Positive Suction Head (NPSH)


Fristam pumps are well known for requiring less net The pump model required is a 722 with a 145 mm impeller
positive suction head (NPSH) available than other sanitary (see Selecting a Fristam Pump). From the actual pump
centrifugal pumps. However, due to the hydraulic principles curve or from the example in Selecting a Fristam Pump, we
involved, some level of NPSH is still required in order for see that the NPSH required is 3 feet.
the pump to run efficiently and without cavitating.
Assuming 10 feet of 1 1/2 inch line and one elbow in the
The NPSH required for each Fristam pump model has been suction line, 8 feet of height of liquid above the pump
determined by careful testing. The results of these tests are center line and pumping 180°F water from an open tank,
illustrated by the NPSH curve under the performance curves we can compute the NPSH available.
for each pump model.
NPSH available = Physical height of liquid + atmospheric
To determine the NPSH available, first add the physical pressure - friction losses - vapor pressure (see “Vapor
height of the liquid above the centerline of the pump inlet Pressure Chart”).
to the pressure above the liquid (in an open tank this is
atmospheric pressure). From this total, subtract the friction NPSH available = 8 ft. + 33.9 ft. - 4.7ft. - 17.3 ft. = 19.9 ft.
losses of the line and fittings on the suction side and the
vapor pressure of the liquid at the operating temperature. Since the NPSH available of 19.9 feet is greater than
The remainder is the NPSH available. This number must the NPSH required 3 feet, the pump has sufficient NPSH
meet or exceed the NPSH required in order for the pump to available to run properly.
function properly. As an example, figure the NPSH available
and required to pump 50 GPM and generate 135 feet water
column of pressure.

8
Specific Gravity and Detailed information is available on viscosity correction factors. Contact
Fristam Pumps for details. The following viscosities may vary, depending

Viscosity for Various Liquids upon products, formulas, and processes used by processors.

Product SP. Visc. Temp Condition Product SP. Visc. Temp Condition
Gr. (cps) °F Gr. (cps) °F

Acetone 0.80 1 70 Milk–Sweetened 1.25 2000 50


Acid: Condensed 500 150
Acetic 1.01 1 100 5% Milk of Magnesia 1.08 200 70
Citric 1.02 1 140 10%
Lactic 1.10 1 140 Oils:
Nitric 1.02 18 70 Butter 0.90 40 70
Alcohol: Corn 0.93 150 60
Ethyl 0.82 1.4 70 Frying 0.90 10 400
Methyl 0.79 0.6 70 Lard 0.96 165 80
Alum 1.33 80 40 50% Conc. Mineral 0.93 150 70
Olive 0.92 110 60
Barbecue Sauce 1.10 150 70 33° Brix Peanut 0.92 100 60
Beer 1.02 1 40 Soybean 0.93 95 60
Beverage Concentrate 1.26 80 80 Vegetable 0.92 40 100
Blood 1.00 5 20
Brine 1.10 to 1 40 Sodium Chloride 1.20 Paint Solvents 0.90 10 70
1.20 Paper Coatings 1.05 400 70 35% TS
Butter–Melted 0.95 90 90 Paraffin 0.90 9 140
Buttermilk 1.04 20 40 Pear Puree 1.30 4000 160 Thixotropic
Perfume 0.95 1 70
Carbon Tetrachloride 1.59 1 70 Pie Filling 1.20 200 140
Catsup 1.15 100 60 Propylene Glycol 1.02 20 30 50%
Chocolate Bar Coating 1.08 65 120
Cream 0.99 20 40 40% Fat Sauce–Apple 2000 71
800 190
Dye, Water Base 1.10 10 70 Salad Dressing 0.96 5000 75
Shampoo 1.00 350 70
Egg—Whole 1.04 68 40 Sorbitol 1.30 150 70 75%
Egg Yolk 1.12 400 68 Soup, Clear 1.00 20 160
200 86 Spaghetti Sauce 1.10 200 140
Ethylene Glycol 1.10 18 70 Syrups:
Corn 1.39 240 180 40° Be
Fat–Animal Melted 0.90 43 110 Dextrose 1.35 280 180 77° Brix
HFCS 42 1.35 160 70 42% TS
Glaze–Donut 1.22 55 120 HFCS 55 1.35 800 70 55% TS
Invert 1.38 800 80 76° Brix
Honey 1.30 230 100 81.2° Brix Maple 1.37 600 68
1500 70 Sugar 1.33 220 80 68° Brix
Soft Drink 1.26 80 80
Ice Cream Mix 1.15 300 40 Varies
Ink, Printer’s 1.20 520 130 Toulene 0.87 1 70
Tomato Paste 1.14 150 75 11% TS
Juice–Single Strength: 1.14 100 180 11% TS
Apple, Clear 1.05 20 140 1.14 1500 200 17% TS
Cranberry 1.03 10 140
Grape 1.05 25 140 Varnish 0.90 125 100
Orange 1.05 20 140 Vinegar 1.01 1 70
Tomato 1.03 180 140
Water 1.00 1 70 Includes WFI
Juice–Concentrate: Wax, Liquid 1.00 75 70
Apple 1.36 600 50 Thixotropic Whey:
Cranberry 1.03 250 100 Thixotropic Acid/Sweet 1.06 2 100
Grapefruit 1000 38 Thixotropic Condensed 1.11 20 100 27% TS
Orange 1.32 5000 38 Thixotropic 1.20 800 40 40% TS
1.20 400 130 50% TS
Liqueurs 1.15 10 70 1.20 550 65 50% TS
1.24 1500 65 60% TS
Margarine 0.93 50 120 Sweetened 1.20 900 55 50% TS
Milk–Whole 1.03 1 40% TS 1.24 600 145 60% TS
Milk–Concentrated 1.10 1000 50 40% TS Salt 1.06 2 80
1.30 100 131 75% TS Wort 1.05 100 150
Milk–Concentrated 1.20 20 110 45% TS
Skim 1.10 95 70 30% TS Yeast–Brewer’s
Milk–Evaporated 1.17 60 70 48% TS Fermenting 1.10 150 40 20% TS
Milk–Skim Condensed 1.20 20 110 45% TS Yeast Slurry 1.10 270 45 35% TS
Yogurt Mix 1.03 20 40

9
Conversion Factors
Length Pressure (continued)
Meters x 3.281 = Feet Atmosphere x 33.9 = Feet of Water
Centimeters x 0.394 = Inches PSI x 2.31 = Feet of Water
Millimeters x 0.0394 = Inches Inches of Hg. x 1.13 = Feet of Water

Mass Flow
Kilograms x 2.2 = Lbs. Lbs. Of Water/Hour x 0.002 = GPM
Gallons Of Water x 8.34 = Lbs. Lbs. Of Fluid/Hour x 0.002 = GPM
Cubic Feet of Water x 62.4 = Lbs. Specific Gravity
Pounds x 0.454 = Kilograms Cu. Meter/Hour x 4.4 = GPM
Kg. Of Water/Minute x 0.264 = GPM
Volume Liters/Minute x 0.264 = GPM
Liter x 0.264 = Gallon GPM x 3.785 = Liters/Minute
Cubic Feet x 7.48 = Gallon
Lbs. Of Water x 0.119 = Gallon Power
Imperial Gallon Liquid HP = GPM x Head ft. x Specific Gravity
(British) x 1.2 = Gallon (U.S.) 3960
U.S. Gallon x 3.785 = Liter
BHP = GPM x Head ft. x Specific Gravity
Pressure 3960 x Pump Efficiency
Feet of Water x 0.433 = PSI
Inches of Hg. x 0.491 = PSI Viscosity
Atmosphere x 14.7 = PSI Centipoise = Centistokes
Meters of Water x 1.42 = PSI Specific Gravity
Kilograms/sq.
Centimeter x 14.22 = PSI Centistokes x 4.64 = SSU (Approx.)
Bar x 14.7 = PSI
Temperature
(1.8 X °C) + 32 = °F
.555 (°F – 32°) = °C
Degrees Kelvin – 273.2 = Degrees Centigrade

Vapor Pressure Chart


VAPOR PRESSURE OF WATER
50

40

30

PRESSURE
(psia)
20

10

0
0 32 50 100 150 200 250 300
TEMPERATURE (F)

10
Loss of Head Due to Friction in Feet per Foot of Stainless
Steel Tubing and in Feet for Sanitary Fittings
Notes:
1. Flow Elbows—R/D = 1.5 A
2. Flow Through Tees—Flow A
to B Port C capped off.
C B
3. Test Medium—Water at 70°F
4. 16 gauge tubing was used for the measurements when the outer diameter (O.D.)
was between 1" - 3" and 14 gauge tubing was used with the 4" O.D. measurement.

*Calculated data for estimating purposes only. Consult your tubing manufacturer with specific questions.

Capacity in O.D. - 1″ O.D. - 1.5″ O.D. - 2″ O.D. - 2.5″ O.D. - 3″ O.D. - 4″


U.S. G.P.M. I.D. - .870″ I.D. - 1.370″ I.D. - 1.870″ I.D. - 2.370″ I.D. - 2.870 ″ I.D. - 3.834″
Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee
2 .01 .01 .1
4 .025 .02 .2
5 .035 .025 .25
10 .12 .06 .4 .02 .01 .15 .005 .015 .1
15 .25 .1 .8 .04 .02 .25 .013 .02 .15
20 .43 .22 1.5 .06 .03 .3 .02 .025 .2 .005 .02 .1 .003 .02 .06
25 .66 .4 2.3 .08 .04 .4 .025 .03 .25 .006 .03 .15 .004 .03 .08
30 .93 .7 3.3 .105 .06 .55 .035 .05 .3 .008 .05 .2 .005 .04 .1
35 1.22 1.25 5.2 .135 .09 .8 .04 .06 .4 .011 .06 .25 .006 .05 .13
40 .17 .11 1.0 .05 .08 .5 .015 .07 .3 .007 .06 .15
45 .21 .16 1.3 .063 .1 .6 .02 .09 .35 .008 .065 .18
50 .25 .2 1.6 .073 .12 .7 .022 .1 .4 .01 .07 .2
60 .34 .35 2.2 .1 .18 .9 .03 .12 .45 .015 .08 .25
80 .57 .76 3.7 .16 .3 1.5 .05 .15 .55 .02 .1 .4
100 .85 1.35 5.8 .23 .44 2.3 .075 .18 .6 .03 .11 .5 .008 .04 .1
120 1.18 2.05 9.1 .32 .64 3.3 .105 .21 1.0 .04 .13 .6 .01 .05 .15
140 .42 .85 4.5 .14 .23 1.25 .05 .16 .8 .013 .06 .2
160 .54 1.13 5.8 .17 .28 1.6 .07 .2 1.1 .015 .07 .25
180 .67 1.45 7.4 .205 .31 2.0 .08 .21 1.3 .02 .08 .3
200 .81 1.82 9.0 .245 .35 2.5 .1 .26 1.6 .025 .09 .4
220 .95 2.22 11.0 .29 .41 3.0 .12 .3 1.9 .028 .1 .5
240 1.10 2.63 13.5 .34 .48 3.7 .14 .33 2.2 .035 .11 .55
260 .39 .53 4.5 .165 .39 2.5 .04 .115 .6
280 .45 .61 5.3 .19 .42 2.8 .045 .12 .65
300 .515 .7 6.2 .22 .5 3.1 .05 .13 .7
350 .68 1.05 8.5 .28 .67 4.1 .07 .15 .9
400 .86 1.55 11.0 .36 .88 5.2 .085 .18 1.2
450 1.05 2.25 13.5 .44 1.1 6.6 .105 .2 1.5
500 .54 1.4 8.0 .13 .23 1.75
550 .64 1.7 9.5 .15 .27 2.1
600 .75 2.05 10.2 .175 .3 2.5
650 .87 2.41 13.0 .2 .34 2.8
700 1.0 2.8 15.0 .23 .4 3.4
750 .26 .43 3.8
800 .3 .5 4.4
850 .33 .56 5.0
900 .37 .62 5.7
950 .41 .7 6.3
1000 .45 .8 7.0
1100 .53 1.06 8.6

11
Fristam Centrifugal Options and Ordering Matrix

MODEL SEAL MATERIALS


1750 3500 1st – Rotating
RPM RPM 2nd – Stationary
FITTING TYPE 3rd – Flush (Double) Seal [FP and FPR only]
701 702 C – Clamp*
711 712 B – Bevel seat Single Seal
721 722 F – 150# flange FR-N – Chrome oxide SS vs. carbon*
3521 3522 3F – 300# flange C-C – Silicon carbide vs. silicon carbide
731 732++ N – NPT FR-C – Chrome oxide SS vs. silicon carbide
–– 1732++ I – I-Line (female)
3531 3532 Double Seal [FP and FPR only]
X – Other (specify) FR-N-K – Chrome oxide SS vs. carbon vs. ceramic*
741 742
1741 1742 C-C-K – Silicon carbide vs. silicon carbide vs. ceramic
3541 3542 FR-C-K – Chrome oxide SS vs. silicon carbide vs. ceramic
751+ 752+
3451 3452
3551 3552
1051 ––
1151++ ––
1161 ––
4001+ ––
+ FPR only * Standard
++ FP/FPX only

Preferred Ordering
Sequence (sample) FPR 3541 205 3x2.5 C FR-N-K VB 15-EP-SF

OTHER OPTIONS
PUMP SERIES
25 – 25 Ra
FP
20 – 20 Ra
FPX
15 – 15 Ra
FPR
EP – Electropolish
ELASTOMERS PV – Passivation
1st – seal (Viton®*) LF – Low ferrite
2nd – cover gasket (Buna*) SF – Stainless steel flange
PORT SIZE TC – Tungsten carbide coating
IMPELLER SIZE V – Viton®
1st – Inlet (in.) B – Buna AS – Aseptic
Impeller diameter (mm)
2nd – Outlet (in.) E – EPDM JH – Jacketed housing
X – Other (specify) CD – Casing drain
BB – Bearing block mounted
AL – Adjustable base with legs
X – Other (specify)

Fristam Centrifugal Specialty Pumps


• Water for Injection
• Aseptic
• Jacketed Housing

12
Pharmaceutical Options
All standard stainless steel components are 316L. Special castings are available
in low-ferrite stainless steel or high-performance alloys such as Hastelloy® and
AL-6XN®. Class VI elastomers are standard for pharmaceutical applications, with
perfluoroelastomers available. Seal materials include stainless steel, ceramic,
silicon carbide, and tungsten carbide.

Electropolishing and enhanced internal surface finishes to 15 Ra are available


on most products.

Casing drain and mounting options provide complete drainability critical for
long-term system cleanliness. Pumps can be easily configured for steam-in-
Comprehensive
place sterilization, with no external cooling devices required.
Documentation Package
Water For Injection (WFI) Pumps Certified Drawings
Fristam is the industry leader for WFI and other high-purity service. Fristam Mill Certification
WFI centrifugal pumps are a precision adaptation of our FP, FPX, and FPR Physical Certifications
pumps. They feature an advanced seal design that protects product sterility, Material Verification
saves valuable product and provides for long seal life. Conformance
Warranty Statement
Fristam pioneered a pressurized double seal flush system that ensures product Certified Finish
sterility and saves valuable product by maintaining positive pressure in the Passivation of Pump
critical seal area. The internal seal design provides extra cooling and lubrication Stainless Steel Tag
on the front seal face to significantly extend seal life and provide for more Paper Location Tag
system uptime. Certified Welding
Hydrostatic Test
Numerous seal and piping configurations, including single seal piping, are Dynamic Seal Test
available to meet your processing requirements. Short Run Test
Performance Test
NPSH Test
Witness Test
Vibration Test
Ferrite Test
Saline Test
Seismic Calculation

13
FP/FPX Performance Curves
Models: 1750 RPM (Composite A)
OF HEAD

FP and FPX 1750 RPM Composite Curves


FEET
BAR

3 100

75

2
PRESSURE

1741
50

1 741

3451
25

3541
731

721
711 3531
3521
701
0 0
GPM 0 50 100 150 200 250 300 350 400

LPM 0 200 400 600 800 1000 1200

CAPACITY 9/23/02
1265000074
RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
14
FP/FPX Performance Curves
Models: 1750 RPM (Composite B)
OF HEAD

FP and FPX 1750 RPM Composite Curves


FEET
BAR

6 200

175
5

150

1161
4
125
PRESSURE

3 100

1151

75
2

50

1
1051
25 3551

0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800

LPM 0 800 1600 2400 3200 4000 4800 5600 6400

CAPACITY 9/23/02
1265000073
RD 2/08
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
15
FPR Performance Curves
Models: 1750 RPM (Composite A)
OF HEAD

FPR 1750 RPM Composite Curve


FEET
BAR

125

3 100

75
751
PRESSURE

1741
50

1 741
25

731
721
711
0
701
0
GPM 0 20 40 60 80 100 120 140 160 180 200

LPM 0 100 200 300 400 500 600 700

CAPACITY 1265000197 Rev. A


RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
16
FPR Performance Curves
Models: 1750 RPM (Composite B)
OF HEAD

FPR 1750 RPM Composite Curve


FEET
BAR

6 200

175
5

150
4001
1161
4
125
PRESSURE

3 100

75
2

50

1
1051
25 3451 3551
3541

3521 3531
0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800

LPM 0 800 1600 2400 3200 4000 4800 5600 6400

CAPACITY 1265000196 Rev. A


RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
17
FP/FPX/FPR Performance Curves
Model: 701 (1750 RPM, Inlet 1.5”, Outlet 1.5”)
HEAD (FT)
PSI

20

8
18

100mm IMPELLER
16 DIAM
ETE
R3
15
95 /16
"

6 14
90

85
12
1/3

80
HP

10
1/
4
4 HP
75
HE
AD

8
CA
PA
CIT
Y

2
4
NPSH IN FEET

2 NPSH REQUIRED 10

0 0
0 4 8 12 16 20 24 28 32 36 40
GPM
LBS./HR. 4,000 8,000 12,000 16,000 20,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
18
FP/FPX/FPR Performance Curves
Model: 711 (1750 RPM, Inlet 2”, Outlet 1.5”)
HEAD (FT)
PSI

30
130mm IMPELLER
DIAMETER
5 1/8"
12 125

120
25
115 HE
AD
CA

1/2
10 PA

HP
1 10

CI
TY
105
20
1 00
1/4
HP

3/4
15

HP
6

10 10
4

2 5 5 NPSH IN FEET

NPSH REQUIRED

0 0
0 10 20 30 40 50 60
GPM
LBS./HR. 5,000 10,000 15,000 20,000 25,000 30,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
19
FP/FPX/FPR Performance Curves
Model: 721 (1750 RPM, Inlet 2”, Outlet 1.5”)
HEAD (FT)
PSI

40

145mm IMPE
16 LLER DIA
METER
5 11/1
6"
140
35
135
14
13 0
30
125 HE
AD
3/4

12
HP

1 20

CA
PA
CI
25

TY
115
10
110
1/2

1HP
HP

20
8

15
6

10
4

2 5 5
NPSH IN FEET

NPSH REQUIRED
0 0
0 10 20 30 40 50 60 70 80
GPM
LBS./HR. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
20
FP/FPX/FPR Performance Curves
Model: 3521 (1750 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

40

16 145mm IMPELLER DIAM


ETER 5 1
1/16"
35
140
14
135
30

12 130

HE
AD
CA
25
125

PA
1 1/2

CI
10

TY
HP
120
1 HP

20
3/4 H

8 115
P
1/2 H
P

15
6

10
4

2 5 10
NPSH IN FEET

NPSH REQUIRED

0 0
0 25 50 75 100 125 150 175 200
GPM
LBS./HR. 12,500 25,000 37,500 50,000 62,500 75,000 87,500 100,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
21
FP/FPX/FPR Performance Curves
Model: 731 (1750 RPM, Inlet 2”, Outlet 1.5”)
HEAD (FT)
PSI

50
175mm IM
PELLER
DIAME
20 170 TER 6
7/8"
165
160
3/4

155
HP

40 150
1/2
HP

15
1H
P

HE
AD

CA
30

PA
CIT
Y
1 1/
2H
P
10

20

5
10 10
NPSH IN FEET

NPSH REQUIRED

0 0
0 20 40 60 80 100
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
22
FP/FPX/FPR Performance Curves
Model: 3531 (1750 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

55 175mm IMPELLLER D
IAMETER 6
7/8"
170
50
165
20
160

155

40

3H
150

P
145
2H
P

15 140
11
/2 H

135

HE
P

AD
30

CAP
130

ACI
1H

TY
P

10

20

5
10 20 NPSH IN FEET

10

NPSH REQUIRED
0 0

GPM 0
50 100 150 200 250 275
LBS./HR. 25,000 50,000 75,000 100,000 125,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
23
FP/FPX/FPR Performance Curves
Model: 741 (1750 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

30 70
205mm IMPELLER
DIAMETER
2 00 8 1/16"
195
190
11 2H
185 /2 P
60 HP
25 180
175 H
1H

1 70
P

EA
D
165

CA
PA
50

CIT
Y
20

3 HP
40

15

30

10

20

5
10 10
NPSH IN FEET

5
NPSH REQUIRED

0 0
0 20 40 60 80 100 120 140
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000 70,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
24
FP/FPX/FPR Performance Curves
Model: 1741 (1750 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

90

35 80 205mm IMPELLER DIAMETER 8 1/16"


200
195 HEA
DC
70 190 APA
30 CIT
Y
185
2H
P

1 80
3H
P

60 175
11

5H
/2 H

25 170

P
P

1 65

50

20

40

15

30

10
20 10

5
10 5
NPSH IN FEET

NPSH REQUIRED

0 0
0 20 40 60 80 100 120 140 160 180
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
25
FP/FPX/FPR Performance Curves
Model: 3541 (1750 RPM, Inlet 3”, Outlet 2.5”)
HEAD (FT)
PSI

80

205mm IMPELLER DIAMETER 8 1/1


6"
30 70
200

195

190 HE
60 AD
25 185 CA
PA
C IT
180 Y
175
50 5H
170 P
20
165
3H

160
P

40
155
1 50
15

30

10
20 20

5
10 10 NPSH IN FEET

NPSH REQU
IRED

0 0
0 50 100 150 200 250 300 350 400
GPM
LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000 175,000 200,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
26
FPR Performance Curves
HEAD (FT)
Model: 751 (1750 RPM, Inlet 3”, Outlet 2”)

NPSH IN FEET
PSI

110
250mm IMPELLER DIAMETER 9 13/16"
45
100 50
245
HE
AD
CA
40 240 PA
90 CIT
Y

5H
235

P
35 80 230 40

7.5
225
220

HP
215
3H

30 70
210
P

205
200
60 30
25

50
20

40 20

15
30

10
20 10

NPSH REQUIRED
5
10

0 0

GPM 0 20 40 60 80 100 120 140 160


LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
27
FP/FPX/FPR Performance Curves
Model: 3451 (1750 RPM, Inlet 3”, Outlet 2”)
HEAD (FT)
PSI

120
50

45
100
250mm IMPELLE
R DIAME
40 TER 9 1
245 3/16"
240
235
35 80 230
225
HE
220 AD
30 CA
5H

215 PA
CI
P

TY
210
60 205
25
3H

200
P

195
2H
P

20

40
7 1/
2H

15
P

10
20 20 NPSH IN FEET

5
10
NPSH REQUIRED

0 0
0 50 100 150 200 250 300
GPM
LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
28
FP/FPX/FPR Performance Curves
Model: 3551 (1750 RPM, Inlet 3”, Outlet 2.5”)
HEAD (FT)
PSI

130
55

120
50

110 250mm IMPELLER


DIAMETER
245 9 13/16
45 "
240
100
235
40 230
90 225
220 HE
AD
35 215
10 H

80
210

CA
P

PA
205
7 1/

C
ITY
2H

30 70 20 0
P

195
5H
P

60
25

50
20 15 H

40
P

15

30

10
20 40
NPSH IN FEET

5
10 20
NPSH REQUIRED
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650
GPM
LBS./HR. 50,000 100,000 150,000 200,000 250,000 300,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
29
FP/FPX/FPR Performance Curves
Model: 1051 (1750 RPM, Inlet 4”, Outlet 4”)
HEAD (FT)
PSI

120
50
280mm
IMPEL
LER D
275 IAME
T ER
45 11"
270
100
265
40 260
255

35 250
80
245

240
20 H

HE
30 AD
P
15 H

CA
P

PA
10 H

CI
60
P

TY
7 1/

25
2H
P

20

40

15

10
20 20 NPSH IN FEET

5
10
D
NPSH REQUIRE
0 0
0 150 300 450 600 750 900
GPM
LBS./HR. 75,000 150,000 225,000 300,000 375,000 450,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
30
FP/FPX Performance Curves
Model: 1151 (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
HEAD (FT)
PSI

200

80
180

70 160

60 140
IMPELLER DIAMETER 11"
280mm
275
120 270
50 HEA
265 DC
10

15

260 APA
HP

HP

CIT
20

255 Y
HP

100 250
25

40
245
HP

HP
40 240 30
HP

80

30

60

20
40 20

10
NPSH IN FEET

20 10
ED
NPSH REQUIR

0 0
0 200 400 600 800 1000
GPM
LBS./HR. 100,000 200,000 300,000 400,000 500,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
31
FP/FPX Performance Curves
Model: 1161 (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
HEAD (FT)
PSI

200

80 320mm IMPELLER DIAMETER 12


180 5/8"
315
310
305
70 160 300 HE
AD
CA
20

295 PA
25

CIT
HP

50
Y
HP

290

HP
140
30
60

40
HP
285

HP
120
50

100
40

80

30

60

20
40 20

10
NPSH IN FEET

20 10
ED
NPSH REQUIR

0 0
0 200 400 600 800 1000
GPM
LBS./HR. 100,000 200,000 300,000 400,000 500,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
32
FPR Performance Curves
Model: 1161 (1750 RPM, Inlet 4”, Outlet 4”)
feet FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
psi

200

80 IMPELLER
320 DIAMETER
175 315
310
70 305 HE
300 AD
CA
5 PA
150 29 CITY
50 HP
290
60 40 HP
285
20 HP
280 25 HP
125 275 15 HP 30 HP
270
50
265
260
255 10 HP
100 24550
2
40 240
Head

75
30

feet
50 20
20

NPSH
10 25 10
NPSH REQUIRED

0 0 0
gpm 0 100 200 300 400 500 600 700 800 900 1000

lbs /hr 0 50,00 100,000 150,000 200,000 250,000 300,00 350,000 400,000 450,000 500,000

Capacity
1265000208
Rev. A

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
33
FPR Performance Curves
HEAD (FT)
Model: 4001 (1750 RPM, Inlet 6”, Outlet 4”)
PSI

200

PELLER DIAMETER 14 13/16


80 360mm IM "
180
350

340 HEA
70 D CAP
160 A CI
330 TY

320
140

75
60

60
310 50

HP
HP
40

HP
HP

300
120
50 290

280
100
40

80

30

60

20
40 20

10 QUIRED
NPSH RE
NPSH IN FEET
20 10

0 0
0 400 800 1200 1600 2000
GPM
LBS./HR. 100,000 200,000 300,000 400,000 500,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
34
FP/FPX Performance Curves
Models: 3500 RPM (Composite)
OF HEAD

FP and FPX 3500 RPM Composite Curves


FEET
BAR

450

420

12
390

360

10 330
3552
300

8 270
PRESSURE

240

210
6
1742
180
742
150
4 3452
120
732 1732
90
3532
3542
2
60 722

30
702 712 3522
0 0
GPM 0 50 100 150 200 300 400 500 600 700 800 900 1000 1100 1200 1300

LPM 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800

CAPACITY 6/18/1998
il-0364.eps
RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
35
FPR Performance Curves
Models: 3500 RPM (Composite A)
OF HEAD

FPR 3500 RPM Composite Curve


FEET
BAR

450
13

12 400

11
350
10
752
9 300

8
250
PRESSURE

6 200
742
5
1742
150
4

3 100

2
50 722
1 712
702
0 0
GPM 0 50 100 150 200 250 300 350 400 450

LPM 0 200 400 600 800 1000 1200 1400 1600

CAPACITY 1265000206 Rev. A


RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
36
FPR Performance Curves
Models: 3500 RPM (Composite B)
OF HEAD

FPR 3500 RPM Composite Curve


FEET
BAR

12 400

11

350
10

9 300
3552
8
250
7
PRESSURE

6 200

5
150
4

3 100
3532 3452
2 3542
50
1
3522
0 0
GPM 0 100 200 300 400 500 600 700 800

LPM 0 400 800 1200 1600 2000 2400 2800

CAPACITY 8/25/04
1265000205
RD 2/08

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
37
FP/FPX/FPR Performance Curves
Model: 702 (3500 RPM, Inlet 1.5”, Outlet 1.5”)
HEAD (FT)
PSI

90

35

75

30

100mm I
M PELLER
D IAMET
E R 3 15
60 /16"
25 95

90

20 85
45
11

80 HE
3/4

/2
1H

HP
HP

AD
P

15
1/2

CA

75
PA
HP

CI
TY

30

10

15
5
NPSH IN FEET

6
4
NPSH REQUIRED
2
0 0 0

GPM 0 10 20 30 40 50 60
LBS./HR. 5,000 10,000 15,000 20,000 25,000 30,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
38
FP/FPX/FPR Performance Curves
Model: 712 (3500 RPM, Inlet 2”, Outlet 1.5”)
HEAD (FT)
PSI

120
50

130mm IMPELLER DI
AMETER 5 1/4
45 "

100 125

40 120
3H
P

115 HE
35 AD
80
2H

CA
P

PA
110

CIT
Y
30

60
25

5H
P
20

40

15

10
20 10 NPSH IN FEET

5
IRED 5
NPSH REQU

0 0
0 20 40 60 80 100 120
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
39
FP/FPX/FPR Performance Curves
Model: 722 (3500 RPM, Inlet 2”, Outlet 1.5”)
HEAD (FT)
PSI

150

145mm IMPELLER DIAMETER 5 1


1/16"
60 140

140

135
120
50
130

125

HE
AD
100

CA
120

PA
40
5 HP

CIT
7 1/

Y
115

2H
P
80
110
3 HP

30
2 HP

60

20

40

10
20 10
NPSH IN FEET

NPSH REQUIRED

0 0
0 20 40 60 80 100 120 140 150
GPM
LBS./HR. 10,000 20,000 30,000 40,000 50,000 60,000 70,000 75,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
40
FP/FPX/FPR Performance Curves
Model: 3522 (3500 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

160

145mm IMPELLE
R DIAME
TER 5
11/16
"
60 140 140

135

10
120
50 130 HP
71
/2 H

125
P

HE
100

AD
5H

CA
P

40

PA
120

CIT
Y
3H

80
P

115
15
HP
30

60

20
40

10
20 40
NPSH IN FEET

20
NPSH REQUIRED
0 0
0 50 100 150 200 250 300 350 400
GPM
LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000 175,000 200,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
41
FP/FPX Performance Curves
Model: 732 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
HEAD (FT)
PSI

200

80
165mm IM
PELLER D
IAMETER
175 6 1/2"
160

70 155
HEA
DC
150 150 APA
CIT
Y

10
HP
60 145

140
71
/2

125
HP

135
50
130
5H
P

100 125
40
120
3H

75
P

30

50 10
20

25 5
10
NPSH IN FEET

QUIRED
NPSH RE

0 0
0 25 50 75 100 125 150 175 200
GPM
LBS./HR. 12,500 25,000 37,500 50,000 62,500 75,000 87,500 100,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
42
FP/FPX Performance Curves
Model: 1732 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
HEAD (FT)
PSI

225

90 210
PELLER DIAMETER 6 1/2"
165mm IM

80 160
180
10 H

155
15 H
P
7 1/2

70
P
150 HE
HP

AD
CA
150 PA
145 CIT
Y

20 H
60

P
140

120
50

40
90

30

60 30

20

30 15
10
NPSH IN FEET

NPSH REQUIRED

0 0
0 50 100 150 200 250 300 350 375
GPM
LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000 175,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
43
FP/FPX/FPR Performance Curves
Model: 3532 (3500 RPM, Inlet 2.5”, Outlet 2”)
HEAD (FT)
PSI

225
175mm IMPELLER DIAMET
ER 6 7/8"
90 170
200
165
80
160
175
155
70 HE
150 AD
150 C
145

25 H

AP
AC
P
20 H
60

I TY
140

30 H
15 H
125 135
71

P
P
/2 H

50
P

10 H

130
5H
P

100
40

75
30

50 50
20

10 25 25
NPSH IN FEET

NPSH REQUIRED
0 0

GPM 0 50 100 150 200 250 300 350 400 450


LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000 175,000 200,000 225,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
44
FP/FPX Performance Curves
Model: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
HEAD (FT)
PSI

300

120
205mm IMPELLER DIAM
ETER 8 1/16"
110 200
250
195
10
HP

190
100 HEA

15
185 DC
APA

HP
CIT
71

180 Y
/2
HP

90 175

20
200

HP
170
80

70
150
60

50

100
40

30

50 10
20
NPSH IN FEET

10 5
ED
NPSH REQUIR
0 0
0 30 60 90 120 150 180
GPM
LBS./HR. 15,000 30,000 45,000 60,000 75,000 90,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
45
FPR Performance Curves
Model: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)
feet FPR model 742 covers the range of both the FP/FPX 732 and 742
psi

300

120
205 IMPELLER DI
AM ETER
200
250
195
HEA
190 DC
100 APA
CIT
185 Y
180
175 15 HP
10 HP
200170

80 165 20 HP
160 7.5 HP
155
150 150
145 5 HP
60
Head

140
135
130 3 HP
100 125
40 120

feet
50 10
20
NPSH
5

UIRED
NPSH REQ
0 0 0
gpm 0 25 50 75 100 125 150 175 200

lbs /hr 0 12,500 25,000 37,500 50,000 62,500 75,000 87,500 100,000

Capacity
8/25/04
1265000207
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
46
FP/FPX Performance Curves
Model: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
HEAD (FT)
PSI

350
150

140
205mm IMPELLER DIAME
TER
130 300 8 1/
200 16"

120 195
190
110
250 185
15 H

180
40 H

100
P

30 H
20 H
10 H

25 H

175
P
P
P

HE 50 HP

90
AD

170
200
CA
PA
CIT

80
Y

70
150
60

50

100
40

30

50 20
20
NPSH IN FEET

10 10
IR E D
NPSH REQU
0 0
0 100 200 300 400 500 600 700
GPM
LBS./HR. 50,000 100,000 150,000 200,000 250,000 300,000 350,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
47
FPR Performance Curves
Model: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)
feet FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
psi

350

140
IMPELLER DIAMETER
205
300
200
HE
120 195 AD
CA
PA
190 C ITY
250185
25 HP
30 HP
100 180
40 HP
20 HP
175
170 15 HP
200 5
16
10 HP
80 160
155 50 HP
150
Head

7.5 HP
150 145
60
140

100
40

50 feet
20
20
NPSH
10
NPSH REQUIRED
0 0 0
gpm 0 50 100 150 200 250 300 350 400 450 500

lbs /hr 0 25,000 50,000 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000

Capacity
8/26/04
1265000209
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
48
FP/FPX/FPR Performance Curves
HEAD (FT)
Model: 3542 (3500 RPM, Inlet 3”, Outlet 2.5”)
PSI

300

205mm IMPELLER
120 DIAMETER
280 8 1/16"
200
110
195

240
100 190

185 HE
A

40
90

HP

DC
180

AP
30
200

AC
HP
175

ITY
25

80
170
HP
20

50
165
HP

HP
70 160
160
15
HP

155
60
150
10
HP

120
50

40

80
30

20
40 25
NPSH IN FEET

10 E D
NPSH REQUIR

0 0
0 100 200 300 400 500 600 700 750
GPM
LBS./HR. 50,000 100,000 150,000 200,000 250,000 300,000 350,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
49
FPR Performance Curves
HEAD (FT) Model: 752 (3500 RPM, Inlet 3”, Outlet 2”)
PSI

500 100

200 250mm IMPELLER DIAME


450 TER 9 13/16 90
"
245 HEA
180 D CAP
ACI
400 240 TY 80
235
160
230
350 70
225

50
40
220

HP
140

HP
215
30

300 210 60
HP

205
15

25

120
H

20

HP

200
P

HP

250 50
100

200 40
80

150 30
60

100 20
40

IRED
NPSH REQU
NPSH IN FEET

20 50 10

0 0

GPM 0 50 100 150 200 250 300 350


LBS./HR. 25,000 50,000 75,000 100,000 125,000 150,000 175,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
50
FP/FPX/FPR Performance Curves
HEAD (FT)
Model: 3452 (3500 RPM, Inlet 3”, Outlet 2”)
PSI

400
170 250
mm
IMP
160 245 ELL
ER
DIA
240 ME
350 TER
150 235 91
3/1
6 "
140 230

225
130 300
220
120 215
HE
40 H

DA
P

210
CA

110
30 H

PA

250
25 H

CI
P

205
TY
P

100
20 H

200
P

90
50 HP

195
15 H

200
P

80

70
150
60

50
100
40

30

20 50
NPSH IN FEET

10 20
NPSH REQUIRED
0 0
0 100 200 300 400 500 600 700 800
GPM
LBS./HR. 50,000 100,000 150,000 200,000 250,000 300,000 350,000 400,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
51
FP/FPX/FPR Performance Curves
HEAD (FT)
Model: 3552 (3500 RPM, Inlet 3”, Outlet 2.5”)
PSI

500

200
250mm IMPELLER DIAMETER 9 13/1
6"
245
180
HEAD
400 240 CAP
ACIT
Y

75
235

HP
160 230
225 60
220 HP
50

140
HP

215
300 210
40

205
HP
25

120
HP

200
30
HP

195

100

200
80

60

100 50
40
NPSH IN FEET

20 25

NPSH REQUIRED

0 0
0 150 300 450 600 750
GPM
LBS./HR. 75,000 150,000 225,000 300,000 375,000
CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
52
53
FP Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

D
H B OUTLET
C
198
J (7.80")

ØK
ØG
INLET
180
(7.09")

210
98 (8.27")
(3.88")
180 ADJ. LEGS
36(1.42") X 16(.63") SLOT (7.09") F
(4 PLACES) (OPTIONAL)
356 38 (1.50")
(14.00") E MAX. ADJ.
203
(8.00")

1265000384 REV-

DIMENSIONS IN MILLIMETERS (INCHES) DIMENSIONS IN


PUMP MODEL INLET OUTLET MOTOR HP MOTOR MILLIMETERS (INCHES)
A B C D E F ØG
FRAME
108 44.5 108.5 146.5 154.5 186.5 150 1750 RPM 3500 RPM H J ØK
FP 701 / 702 1.5" 1.5" (4.25") (1.75") (4.27") (5.77") (6.08") (7.34") (5.90") 115 236 157
0.5 HP 56C (4.53") (9.29") (6.19")
144 58 113 150 158 190 185
FP 711 / 712 2" 1.5" (5.67") (2.28") (4.45") (5.90") (6.22") (7.48") (7.28") 115 236 157
0.75 HP 0.75 HP 56C (4.53") (9.29") (6.19")
170 79 113 150 158 190 230
FP 721 / 731 / 722 2" 1.5" (6.69") (3.11") (4.45") (5.90") (6.22") (7.48") (9.06") 115 236 157
1 HP 56C (4.53") (9.29") (6.19")
195 96 101 141 149 181 270
FP 741 / 732 / 742 2.5" 2" (7.68") (3.78") (3.98") (5.55") (5.87") (7.13") (10.63") 115 252 157
1 HP 1.5 HP 143TC (4.53") (9.94") (6.19")
FP 1741 / 1732 / 200 91 104 150.5 158.5 190.5 270
2.5" 2" (7.87") (3.58") (4.09") (5.93") (6.24") (7.50") (10.63")
1742 133 259 183
1.5 HP 145TC (5.22") (10.19") (7.19")
190 80 118 162 170 202 230
FP 3521 / 3522 2.5" 2" (7.48") (3.15") (4.64") (6.38") (6.69") (7.95") (9.06") 133 284 183
2 HP 2 HP 145TC (5.22") (11.19") (7.19")
191 95 115.5 162 170 202 260
FP 3531 / 3532 2.5" 2" (7.52") (3.74") (4.55") (6.38") (6.69") (7.95") (10.24") 133 284 183
3 HP 145TC (5.22") (11.19") (7.19")
211 115 118 162 170 202 290
FP 3541 / 3542 3" 2.5" (8.31") (4.53") (4.64") (6.38") (6.69") (7.95") (11.42") 133 313 216
3 HP 182TC (5.23") (12.31") (8.50")
211 140 114 158 166 198 350
FP 3451 / 3452 3" 2" (8.31") (5.51") (4.49") (6.22") (6.54") (7.80") (13.78") 152 348 216
5 HP 5 HP 184TC (6.00") (13.68") (8.50")
152 386 216
7.5 HP 184TC (6.00") (15.18") (8.50")
189 388 263
7.5 HP 7.5 HP 213TC (7.46") (15.27") (10.34")
189 388 263
10 HP 215TC (7.46") (15.27") (10.34")
189 416 263
10 HP 15 HP 215TC (7.46") (16.40") (10.34")
1265000385 REV-

54
FP Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

J L D
H B OUTLET
C

INLET A
BALDOR

ØK

250 ØE
(9.84")

290
M (11.42")

ADJ. BASE
300 (OPTIONAL)
19(.75") X 35(1.38") SLOT (11.81") F N
(4 PLACES) 559 300
(22.00") E (11.81")

1265000386 REV-

DIMENSIONS IN MILLIMETERS (INCHES) MOTOR HP MOTOR DIMENSIONS IN MILLIMETERS (INCHES)


PUMP MODEL INLET OUTLET
A B C D E F ØG 1750 RPM 3500 RPM FRAME H J ØK L M N
250 170 167 202.5 254 317.5 406 133 313 216 200 117 44.5
FP 1051 4" 4" (9.84") (6.69") (6.57") (7.97") (10.00") (12.50") (15.98") *3 HP 182TC (5.23") (12.31") (8.50") (7.87") (4.62") (1.75")
250 170 110.5 146 197.5 261 406 189 388 263 200 117 44.5
FP 1151 4" 4" (9.84") (6.69") (4.35") (5.75") (7.78") (10.28") (15.98") *5 HP 213TC (7.46") (15.27") (10.34") (7.87") (4.62") (1.75")
250 170 110.5 146 197.5 261 406 189 388 263 200 117 44.5
FP 1161 4" 4" (9.84") (6.69") (4.35") (5.75") (7.78") (10.28") (15.98") **7.5 HP 213TC (7.46") (15.27") (10.34") (7.87") (4.62") (1.75")
250 170 111 146 197.5 261 406 189 416 263 200 117 44.5
FP 1161 6" 4" (9.84") (6.69") (4.37") (5.75") (7.78") (10.28") (15.98") **10 HP 215TC (7.46") (16.40") (10.34") (7.87") (4.62") (1.75")
195 96 101 143.5 195 258.5 270 220 415 263 200 98*** 38****
FP 742 2.5" 2" (7.68") (3.78") (3.98") (5.65") (7.68") (10.18") (10.63") 15 HP 254TC (8.67") (16.33") (10.34") (7.87") (3.88") (1.50")
200 91 104 153 204.5 268 270 239 499 336 200 98*** 38****
FP 1732 / 1742 2.5" 2" (7.87") (3.58") (4.09") (6.02") (8.05") (10.55") (10.63") 20 HP 256TC (9.42") (19.66") (13.25") (7.87") (3.88") (1.50")
191 95 115.5 164.5 216 279.5 260 225 491 263 200 98 38
FP 3532 2.5" 2" (7.52") (3.74") (4.55") (6.48") (8.50") (11.00") (10.24") 20 HP 256TC (8.88") (19.34") (10.34") (7.87") (3.88") (1.50")
211 115 118 164.5 216 279.5 290 333 588 395 200 117 44.5
FP 3542 3" 2.5" (8.31") (4.53") (4.64") (6.48") (8.50") (11.00") (11.42") 25 HP 284TC (13.12") (23.13") (15.56") (7.87") (4.62") (1.75")
211 140 114 160.5 212 275.5 350 333 588 395 200 98 38
FP 3452 3" 2" (8.31") (5.51") (4.49") (6.32") (8.35") (10.85") (13.78") 25 HP 284TSC (13.12") (23.13") (15.56") (7.87") (3.88") (1.50")
231 140 119 170.5 222 285.5 350 333 588 395 200 117 44.5
FP 3551 / 3552 3" 2.5" (9.09") (5.51") (4.68") (6.71") (8.74") (11.24") (13.78") 30 HP 286TC (13.12") (23.13") (15.56") (7.87") (4.62") (1.75")
333 588 395 200 98 38
30 HP 286TSC (13.12") (23.13") (15.56") (7.87") (3.88") (1.50")
333 588 395 220 117 44.5
40 HP 324TSD (13.12") (23.13") (15.56") (8.66") (4.62") (1.75")
333 588 395 220 117 44.5
40 HP 324TSD (13.12") (23.13") (15.56") (8.66") (4.62") (1.75")
333 588 395 220 117 44.5
50 HP 326TSD (13.12") (23.13") (15.56") (8.66") (4.62") (1.75")
333 588 395 220 117 44.5
50 HP 326TSD (13.12") (23.13") (15.56") (8.66") (4.62") (1.75")
* 3551 ONLY
1265000387 REV-
** 3551, 1051 & 1151 ONLY
*** 117 (4.62") FOR 1051, 1151 & 1161
**** 44.5 (1.75") FOR 1051, 1151 & 1161

55
FPX Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

F N D
C J B
OUTLET

A
ØE
ØG
H
INLET
98 ADJ. LEGS
ØP (3.88") (OPTIONAL)

K M
38 (1.50")
Q MAX. ADJ. L il-0657

DIMENSIONS IN MILLIMETERS (INCHES) MOTOR HP MOTOR DIMENSIONS IN MILLIMETERS (INCHES)


PUMP MODEL INLET OUTLET
A B C D ØE 1750 RPM 3500 RPM FRAME F ØG H J K L M N ØP Q
108 44.5 108.5 146.5 150 281 183 89 133 102 140 70 120 8.7 356
FPX 701 / 702 1.5" 1.5" (4.25") (1.75") (4.27") (5.77") (5.90") 1 HP 1.5 HP 143TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
144 58 113 150 185 281 183 89 133 102 140 70 120 8.7 356
FPX 711 / 712 2" 1.5" (5.67") (2.28") (4.45") (5.90") (7.28") 1.5 HP 145TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
170 79 113 150 230 281 183 89 133 102 140 70 120 8.7 356
FPX 721 / 731 / 722 2" 1.5" (6.69") (3.11") (4.45") (5.90") (9.06") 2 HP 2 HP 145TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
195 96 101 141 270 313 183 114 132 140 191 89 140 10.3 356
FPX 741 / 732 / 742 2.5" 2" (7.68") (3.78") (3.98") (5.55") (10.63") 3 HP 182TC (12.31") (7.19") (4.50") (5.21") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
200 91 104 150.5 270 348 183 114 132 140 191 89 140 10.3 356
FPX 1741 / 1732 / 1742 2.5" 2" (7.87") (3.58") (4.09") (5.93") (10.63") 3 HP 182TC (13.69") (7.19") (4.50") (5.21") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
190 80 118 162 230 347 216 114 152 140 191 89 140 10.3 356
FPX 3521 / 3522 2.5" 2" (7.48") (3.15") (4.64") (6.38") (9.06") 5 HP 184TC (13.68") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
191 95 115.5 162 260 386 216 114 152 140 191 89 140 10.3 356
FPX 3531 / 3532 2.5" 2" (7.52") (3.74") (4.55") (6.38") (10.24") 5 HP 184TC (15.18") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
211 115 118 162 290 386 216 114 152 140 191 89 140 10.3 356
FPX 3541 / 3542 3" 2.5" (8.31") (4.53") (4.64") (6.38") (11.42") 7.5 HP 184TC (15.18") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
211 140 114 158 350 388 263 133 189 140 216 108 140 10.3 356
FPX 3451 / 3452 3" 2" (8.31") (5.51") (4.49") (6.22") (13.78") 7.5 HP 213TC (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
231 140 119 168 350 388 263 133 189 140 216 108 140 10.3 356
FPX 3551 3" 2.5" (9.09") (5.51") (4.68") (6.61") (13.78") 10 HP 10 HP 215TC (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
436 263 133 189 140 216 108 140 10.3 356
15 HP 215TC (17.15") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
447 263 159 225 210 254 121 169 13.5 406
15 HP 254TC (17.59") (10.34") (6.25") (8.88") (8.25") (10.00") (4.75") (6.65") (17/32") (16.00")
491 263 159 225 254 254 121 169 13.5 406
20 HP 256TC (19.34") (10.34") (6.25") (8.88") (10.00") (10.00") (4.75") (6.65") (17/32") (16.00")
499 336 159 239 254 254 121 169 13.5 406
20 HP 256TC (19.66") (13.25") (6.25") (9.42") (10.00") (10.00") (4.75") (6.65") (17/32") (16.00")
1265000540

56
FPX Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

H Q D
C L B OUTLET

INLET A
BALDOR

ØJ

K ØE

117.5
ØR (4.62")
ADJ. LEGS
(OPTIONAL)
M P 44.5 (1.75") N il-0661
S MAX. ADJ.

MOTOR HP
PUMP MODEL INLET OUTLET DIMENSIONS IN MILLIMETERS (INCHES) MOTOR DIMENSIONS IN MILLIMETERS (INCHES)
A B C D ØE 1750 RPM 3500 RPM FRAME H ØJ K L M N P Q ØR S
250 170 167 202.5 406 388 263 133 189 140 216 108 200 10.3 470
FPX 1051 4" 4" 7.5 HP 213TC
(9.84") (6.69") (6.57") (7.97") (15.98") (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 416 263 133 189 178 216 108 200 10.3 470
FPX 1151 4" 4" 10 HP 215TC
(9.84") (6.69") (4.35") (5.75") (15.98") (16.40") (10.34") (5.25") (7.46") (7.00") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 447 270 159 226 210 254 121 200 13.5 444
FPX 1161 4" 4" 15 HP 254TC
(9.84") (6.69") (4.35") (5.75") (15.98") (17.59") (10.62") (6.25") (8.88") (8.25") (10.00") (4.75") (7.87") (17/32") (17.50")
250 170 111 146 406 499 320 159 239 254 254 121 200 13.5 470
FPX 1161 6" 4" 20 HP 256TC
(9.84") (6.69") (4.37") (5.75") (15.98") (19.66") (12.60") (6.25") (9.42") (10.00") (10.00") (4.75") (7.87") (17/32") (18.50")
200 91 104 153 270 588 367 178 333 241 279 121 200 13.5 444
FPX 1742 2.5" 2" 25 HP 284TC
(7.87") (3.58") (4.09") (6.02") (10.63") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
191 95 115.5 164.5 260 588 367 178 333 241 279 121 200 13.5 444
FPX 3532 2.5" 2" 25 HP 284TSC
(7.52") (3.74") (4.55") (6.48") (10.24") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
211 115 118 164.5 290 588 367 178 333 279 279 121 200 13.5 444
FPX 3542 3" 2.5" 30 HP 286TC
(8.31") (4.53") (4.64") (6.48") (11.42") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
211 140 114 160.5 350 588 367 178 333 279 279 121 200 13.5 444
FPX 3452 3" 2" 30 HP 286TSC
(8.31") (5.51") (4.49") (6.32") (13.78") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
231 140 119 170.5 350 636 413 203 371 267 318 133 216 16.7 470
FPX 3552 3" 2.5" 40 HP 324TC
(9.09") (5.51") (4.68") (6.71") (13.78") (25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 267 318 133 216 16.7 470
40 HP 324TSC
(25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TSC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")

il-0660

57
FPR Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

P B
Outlet
L T D

A
Inlet

X
Ø V Adjustable Legs
(Optional) R
Z
Q S Y
W Max. Leg
Adjustment

MOTOR HP MOTOR
FRAME
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET 1265000202
A B Rev
C A D E
1750 RPM 3500 RPM
284 175 89 133 101.6 140 127 120 8.7 356 98 38 57.2 108 44.5 106.5 139.5 150
1 HP 1.5 HP 143TC FPR 701/702 1.5" 1.5"
11.18" 6.89" 3.5" 5.25" 4" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 4.25" 1.75" 4.19" 5.49" 5.91"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 144 58 113 145 185
1.5 HP 145TC FPR 711/712 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 5.67" 2.28" 4.45" 5.71" 7.28"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 170 79 113 145 230
2 HP 2 HP 145TC FPR 721/731/722 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 6.69" 3.11" 4.45" 5.71" 9.06"
340 221 114 149 114 191 108 169 10.3 356 98 38 69.9 195 96 101 136 270
3 HP 182TC FPR 741/742 2.5" 2"
13.39" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.68" 3.78" 3.98" 5.35" 10.63"
354 221 114 149 114 191 108 169 10.3 356 98 38 69.9 200 91 104 145.5 270
3 HP 182TC FPR 1741/1742 2.5" 2"
13.94" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.87" 3.58" 4.09" 5.73" 10.63"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 190 80 118 157.5 230
5 HP 184TC FPR 3521/3522 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.48" 3.15" 4.65" 6.2" 9.06"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 191 95 115.5 157.5 260
5 HP 184TC FPR 3531/3532 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.52" 3.74" 4.55" 6.2" 10.24"
423 221 114 149 140 191 108 169 10.3 356 98 38 69.9 211 115 118 157.5 290
7.5 HP 184TC FPR 3541/3542 3" 2.5"
16.65" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 4.53" 4.65" 6.2" 11.42"
403 260 133 187 140 216 108 169 10.3 356 98 38 88.9
7.5 HP 213TC
15.87" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
403 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
15.87" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
416 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
16.38" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
515 260 133 187 178 216 108 169 10.3 356 98 38 88.9
15 HP 215TC
20.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
499 327 159 244 210 254 102 169 13.5 406 98 38 108.0
15 HP 254TC
19.65" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"

1265000463

58
FPR Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

L T D
P B
Z C Outlet

Ø E

Inlet
M

Adjustable Legs R X
Ø V
(Optional)

Q S
Y
W Max. Leg
Adjustment

1265000203 Rev C

MOTOR HP MOTOR
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM FRAME
313 221 114 149 114 191 108 160 10.3 356 98 38 69.9 205 145 99 142 379
3 HP 182TC FPR 751/752 3" 2"
12.32" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.07" 5.71" 3.9" 5.59" 14.92"
348 221 114 149 114 191 108 160 10.3 356 98 38 69.9 211 140 114 160.5 350
3 HP 182TC FPR 3451/3452 3" 2"
13.7" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 5.51" 4.49" 6.32" 13.78"
347 221 114 149 140 191 108 160 10.3 356 98 38 69.9 230 140 119 170 350
5 HP 184TC FPR 3551/3552 3" 2.5"
13.66" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.06" 5.51" 4.69" 6.69" 13.78"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 167 202.5 406
5 HP 184TC FPR 1051 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 6.57" 7.97" 15.98"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 110.5 146 406
7.5 HP 184TC FPR 1161 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 4.35" 5.75" 15.98"
388 260 133 187 140 216 108 160 10.3 356 98 38 88.9
7.5 HP 213TC
15.28" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
388 260 133 187 178 216 108 160 10.3 356 98 38 88.9
10 HP 10 HP 215TC
15.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
436 260 133 187 178 216 108 160 10.3 356 98 38 88.9
15 HP 215TC
17.17" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
447 327 159 244 210 254 102 160 13.5 406 98 38 108
15 HP 254TC
17.6" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
491 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.33" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TSC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TSC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"

1265000463

59
FPR Double Flange Dimensional Drawing Model 4001

232 239.5
A [9.13"] [9.43"] 228.5
127.8 D [9.00"]
4" SANITARY [5.03"]
CLAMP

300.5
[11.83"]

440
C [ 17.32"]
6" SANITARY
CLAMP

ADJUSTABLE LEGS
K (OPTIONAL)
E G
4X ØH

J
44.4 [1.75"]
MAX. ADJ. F

1265000053
8/19/02

MOTOR MOTOR
A B C D E F G ØH J K
HP FRAME
636 418 203 371 267 317 133 16.7 470 117
40 HP 324TC
25" 16.5" 8" 14.6" 10.5" 12.5" 5.2" 0.7" 18.5" 4.6"
636 418 203 371 305 317 133 16.7 470 117
50 HP 326TC
25" 16.5" 8" 14.6" 12" 12.5" 5.2" 0.7" 18.5" 4.6"
684 470 229 380 286 355 149 16.7 508 127
60 HP 364TC
26.9" 18.5" 9" 15" 11.3" 14" 5.9" 0.7" 20" 5"
684 470 229 380 311 355 149 16.7 508 127
75 HP 365TC
26.9" 18.5" 9" 15" 12.2" 14" 5.9" 0.7" 20" 5"
782 520 254 477 349 406 168 20.6 508 127
100 HP 405TC
30.8" 20.5" 10" 18.8" 13.7" 16" 6.6" 0.8" 20" 5"

1265000054
1/28/2008

60
Positive
Centrifugal Displacement Mixing

Mission Statement
Fristam Pumps USA shall be the leader in
achieving total customer satisfaction by providing
the highest value hygienic pumping and mixing
solutions, and world class customer service.

Fristam Pumps USA


2410 Parview Road
Middleton, WI 53562
TEL: 1-608-831-5001
1-800-841-5001
FAX: 1-608-831-8467
Re-order #1050000103 www.fristam.com/usa
©2012 Fristam Pumps USA fristam@fristampumps.com

You might also like