You are on page 1of 64

3 79'-0" 5 6 6'

1' 1 2 4
+100' Roof Top Level

FG FG&SD FG&SD FG
+94'-6" Roof Beam Level

10'-0" 10'-0"

3'-6"
+82'-0" Roof Floor Level

11'-0"
FG
FG&W1 FG&W2 FG&W2 FG&W1 NOTE
+71'-0" Sixth Floor Level

ELEVATION REVISION ER 9.7

11'-0"
FG
FG&W1 FG&W2 FG&W2 FG&W1
+60'-0" Fifth Floor Level
OWNER

11'-0"
DIGICOM
FG
FG&W1 FG&W2 FG&W2 FG&W1 CFG
+49'-0" Fourth Floor Level

PROJECT SEVEN STORE ED R.C BUILDING WITH

11'-0"
FG
PENTHOUSE BASEMENT
CFG FG&W1 FG&W2 FG&W2 FG&W1
+38'-0" Third Floor Level

_
BLOCK NO.

11'-0"
FG
FG&W2 FG&W2 CFG _
+27'-0" Second Floor Level
FG&W1 FG&W1 LOT NO.

TOWN SHIP -

11'-0"
FG
CFG FG&W1 FG&W2 FG&W2 FG&W1
+16'-0" First Floor Level
SUBJECT
GF-FG1 GF-FG2 Main Entrance GF-FG3 FRONT SIDE ELEVATION

13'-0"
+3'-0" Ground Floor Level
SCALE 1/16" = 1'-0" SHEET NO.

3'-0"
±0'-0" Pavement Level

DATE 26.9.2020 01

8'-0"
-8'-0" Basement Floor Level L.S-

1 FRONT SIDE ELEVATION


A- SCALE: 1/16" = 1' - 0"
6' 6 5 4 3 2 1 1'

+100' Roof Top Level

+94'-6" Roof Beam Level

F F

+82'-0" Roof Floor Level

11'-0"
21'-3"
[6472.20]
W2 W2
NOTE
+71'-0" Sixth Floor Level

ELEVATION REVISION ER 9.7

11'-0"
F

+60'-0" Fifth Floor Level W2

OWNER

11'-0"
F
DIGICOM

+49'-0" Fourth Floor Level W2

PROJECT SEVEN STORE ED R.C BUILDING WITH

11'-0"
F F PENTHOUSE BASEMENT

+38'-0" Third Floor Level W2

_
BLOCK NO.

11'-0"
F
_
+27'-0" Second Floor Level W2 LOT NO.

TOWN SHIP -

11'-0"
F F

+16'-0" First Floor Level W2


SUBJECT
BACK SIDE ELEVATION

13'-0"
F

+3'-0" Ground Floor Level W2


SCALE 1/16" = 1'-0" SHEET NO.

3'-0"
±0'-0" Pavement Level

DATE 26.9.2020 02
8'-0"
-8'-0" Basement Floor Level L.S-

1 BACK SIDE ELEVATION


A- SCALE: 1/16" = 1' - 0"
A' A B C D D'
4'-0" 20'-0" 20'-0" 20'-0" 6'

+100' Roof Top Level

FG&SD2 FG&SD2 FG&SD2


+94'-6" Roof Beam Level
W2

12'-6"
17'
+82'-0" Roof Floor Level

FG&SD3 FG&SD3 FG&SD3 FG&SD3

11'-0"
NOTE
+71'-0" Sixth Floor Level

FG&SD3 FG&SD3 FG&SD3 FG&SD3 ELEVATION REVISION ER 9.7

11'-0"
+60'-0" Fifth Floor Level
OWNER

11'-0"
DIGICOM

9'-8"

9'-8"
FG&W7 FG&W4
+49'-0" Fourth Floor Level

PROJECT SEVEN STORE ED R.C BUILDING WITH

11'-0"
PENTHOUSE BASEMENT
FG&W5 FG&W6
+38'-0" Third Floor Level
18'-9" _
BLOCK NO.

11'-0"
9'-8"

FG&W7 FG&W4 _
+27'-0" Second Floor Level
LOT NO.

TOWN SHIP -

11'-0"
FG&W5 FG&W6
+16'-0" First Floor Level
SUBJECT
LEFT SIDE ELEVATION

13'-0"
+3'-0" Ground Floor Level
SCALE 1/16" = 1'-0" SHEET NO.

3'-0"
±0'-0" Pavement Level

DATE 26.9.2020 03
-5'-0" Pavement Level 8'-0"
-8'-0" Basement Floor Level L.S-

1 LEFT SIDE ELEVATION


A- SCALE: 1/16" = 1' - 0"
D' D C B A A'
6' 20'-0" 20'-0" 20'-0" 4'-0"

+100' Roof Top Level

FG&SD2 FG&SD2 FG&SD2


+94'-6" Roof Beam Level
W2

12'-6"

17'
+82'-0" Roof Floor Level

FG&SD3 FG&SD3 FG&SD3 FG&SD3

11'-0" NOTE
+71'-0" Sixth Floor Level

FG&SD3 FG&SD3 FG&SD3 FG&SD3 ELEVATION REVISION ER 9.7


11'-0"

+60'-0" Fifth Floor Level


OWNER
11'-0"

DIGICOM
FG&W5 FG&W6 FG&W5
+49'-0" Fourth Floor Level
17'-7" 18'-9"
PROJECT SEVEN STORE ED R.C BUILDING WITH
11'-0"

PENTHOUSE BASEMENT
9'-8"

9'-8"
FG&W3 FG&W4 FG&W7
+38'-0" Third Floor Level

_
BLOCK NO.
11'-0"

FG&W5 FG&W6 FG&W5


_
+27'-0" Second Floor Level
LOT NO.

TOWN SHIP -
11'-0"

FG&W3 FG&W4 FG&W7


+16'-0" First Floor Level
SUBJECT
RIGHT SIDE ELEVATION
13'-0"

FG&W8
+3'-0" Ground Floor Level
SCALE 1/16" = 1'-0" SHEET NO.
3'-0"

±0'-0" Pavement Level

DATE 26.9.2020 04
8'-0"

-5'-0" Pavement Level

-8'-0" Basement Floor Level L.S-

1 RIGHT SIDE ELEVATION


A- SCALE: 1/16" = 1' - 0"
6' 20'-0" 20'-0" 20'-0" 4'-0"
D' D C B A A'

+100' Roof Top Level

5'-0"
4 Angle Color Roofing with
+94'-6" Roof Beam Level
4"x2" Lip Channel Purlin and
6"x3" I Section Rafther &

10'-11"
8"x8" H Section Prop Column

3'-6"
+82'-0" Roof Floor Level 25 G RC Concrete Floor Slab

Riser : 6"

11'-0"
Thread : 10.5"
Waist : 5"
NOTE
+71'-0" Sixth Floor Level 25 G RC Concrete Floor Slab

Riser : 6"
ELEVATION REVISION ER 9.7

11'-0"
Thread : 10.5"
Waist : 5"

+60'-0" Fifth Floor Level 25 G RC Concrete Floor Slab


OWNER
Riser : 6"

11'-0"
Thread : 10.5" DIGICOM
Waist : 5"

+49'-0" Fourth Floor Level 25 G RC Concrete Floor Slab

Riser : 6"
PROJECT SEVEN STORE ED R.C BUILDING WITH

11'-0"
Thread : 10.5" PENTHOUSE BASEMENT
Waist : 5"

+38'-0" Third Floor Level 25 G RC Concrete Floor Slab


_
BLOCK NO.
Riser : 6"

11'-0"
Thread : 10.5"
Waist : 5"
_
+27'-0" Second Floor Level
LOT NO.
25 G RC Concrete Floor Slab

Riser : 6" TOWN SHIP -

11'-0"
Thread : 10.5"
Waist : 5"

5'-6"
+16'-0" First Floor Level 25 G RC Concrete Floor Slab SUBJECT
CROSS SECTIONAL DETAIL
Riser : 6"
5'-3"

13'-0"
Thread : 10.5"
Waist : 5"

6'-6"
+3'-0" Ground Floor Level -0"
25 G RC Concrete Floor Slab
13' SCALE 1/16" = 1'-0" SHEET NO.

3'-0"
±0'-0" Pavement Level

Riser : 6" 5'-3" DATE 26.9.2020 05


Thread : 10.5"

8'-0"
Waist : 5"
5'-6"

-8'-0" Basement Floor Level L.S-


4'-0"

Lift Pit Lift Pit 3'-0" THICK MAT FOOTING

2" Thick (1:3:6) Lean Concrete


9" Thick Hard Core
3'-0"

1 CROSS SECTIONAL DETAIL


A- SCALE: 1/16" = 1' - 0"
13'-321" 13'-1021" 13'-7"
3'-7" 13'-1021"
[4051] [4229] [4140] 10'-3"
[1092] [4229]

[1156]
3'-921"
[3454]

[3454]

[3454]

[3454]
11'-4"

11'-4"

11'-4"

11'-4"

[2870]

[2819]
9'-5"

9'-3"
[1257]
4'-121"
Facade fix Glass 1
NOTE
Main Entrance GF Fix Glass 1 GF Fix Glass 2 GF Fix Glass 3 Cantilever fix Glass
Stair Case Glass
1 Unit 4 Units 12 Units
1 Units 1 Units 1 Units FG - 6 Units CFG D W
FG&W1
GF-FG1 GF-FG2

13'-7"
17'-7" 18'-421" 18'-9" 17'-7" 18'-421" OWNER
[4140] [5359] [5601] [5715] [5359] [5601] DIGICOM
[2921]
[2819]

[2718]
8'-11"
9'-7"
9'-3"

FG&W3 - 2 Units PRO ECT SEVEN STOREYED R.C BUILDING WITH


Facade fix Glass 2
FG&W4 - 4 Units FG&W7 - 4 Units FG&W5 - 6 Units FG&W6 - 4 Units PENTHOUSE + BASEMENT
12 Units
FG&W2

BLOC NO.

LOT NO.
17'-7"
[5359]

TOWN SHIP
[3353]
11'-0"

6'-0"
5'-0"

2'-0" SUB ECT


FRONT SIDE ELEVATION
1'-6"

FG&W8 - 1 Unit F - 40 Units W2 - 16 Units

8'-6" 7'-6" 8'-6"


SCALE
8'-0"
DATE . .
10'-0"

10'-0"

10'-0"

7'-0"

2'-0"
L.S
1'-6"

FLW - 20 Units
FG&SD2 - 6 Units FG - 2 Units FG&SD - 2 Units FG&SD3 - 16 Units
115'-0"

20'-0" 75'-0" 20'-0"

7'-6"
Septic tank
29'-0"

12'-0"

Car Parking Area


Area - 6983 Sft Car Parking Area

NOTE
-3' Level -3' Level Concrete Work
f 'c = 2,5000 psi (28-days)
D3 Store f y = 50,000 psi
Room
D3
W/C (Male) W/C (Female)

D3 D3 OWNER
W2

-0' Level

W2
Fence Line

Fence Line
104'-0"

PROJECT SE EN STOREYED R.C BUILDING WITH


7'-0" PENTHOUSE BASE ENT
60'-0"

Area - 4,500 Sft

8'-0"
W2
-0' Level _
BLOCK NO.

pitch
drainage _
LOT NO.

UP DN
TOWN SHIP -

-0' Level -0' Level


SUBJECT
BUILDING LAYOUT PLAN

-3' Level
-3' Level SCALE 3/32" = 1'-0" SHEET NO.
Ground Tank

10'-0"
15'-0"

18'-0" DATE

L.S-
60'-0"
Signwork area Fence Line

20'-0"
21'-0" 21'-0"
Building Area - 45,002 Sft BUILDING LAYOUT PLAN
1
A-3 SCALE: 3/32" = 1' - 0"
Road Area - 6,983 Sft
1 1 2 3 4 5 6 6'

-3' Level -3' Level


D'

4'-0"
16'-3" 16'-0" 10'-6" 16'-0" 16'-3"
D NOTE
Concrete Work
f 'c = 2,5000 psi (28-days)
f y = 50,000 psi

20'-0"
OWNER

Drive Way PROJECT SE EN STORE ED R.C BUILDIN


60'-0"

20'-0"
-8' Level -11' Level -8' Level WITH PENTHOUSE BASEMENT

Drive Way _
BLOCK NO.

B LOT NO.
_
UP

TOWN SHIP -

20'-0"
CCTV
Room
SUBJECT
BASEMENT

4'-0"
A' SCALE 1/16" = 1'-0" SHEET NO.
-3' Level -3' Level
L.S- DATE
75'-0"

Area - 4977 Sft

1 BASEMENT
A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
GB3 GB3 GB3 GB3 GB3
D

GB2
GB2
S2 S2

AB1
NOTE

GB1

GB1
GB2 GB2
S2 GB1 S2 Concrete Work

GB2
S2

GB2

20'-0"
GB4

GB4
f 'c = 2,500 psi (28-days)
GB4

GB4
S2 S2 f y = 50,000 psi
GB2 GB2 GB3 GB3

GB4
AB1
GB2

GB2
OWNER
S1 S1
S2
C
GB3 GB3 GB3 GB3 GB3 GB3

PROJECT SE EN STORE ED R.C BUILDING WITH

20'-0"
60'-0"

PENTHOUSE BASEMENT
GB4

GB4
GB4

GB4

GB4

GB4
S2 S2 S2 S2 S2
_
BLOCK NO.

GB3 GB3 GB3 GB3 GB3 _


B LOT NO.
S1
GB2
TOWN SHIP -

S2

20'-0"
GB4

GB4
GB4

GB4

GB4

GB4
SUBJECT
S2 S2 S2 GROUND FLOOR BEAM &
SLAB PLAN
GB3
GB3 GB3 GB3 GB3
A SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
A' DATE

L.S-
75'-0"

1 GROUND FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
FB3 FB5 FB3 FB5 FB3
D
FB2 FB2

FB2
FB2
S2 S2

AB1
NOTE
FB2 FB2
S2 S2 Concrete Work

FB2
S2

20'-0"
FB2
f 'c = 2,500 psi (28-days)

FB4

FB4
FB4

FB4
FB1

FB1
FB2 S2 FB2 f y = 50,000 psi
S2
FB3 FB2 FB2 FB3

AB1

FB4
FB2

FB2
OWNER
S1
S2
C
FB2 FB3 FB5 FB3 FB3 FB5 FB3 FB2

PROJECT SE EN STORE ED R.C BUILDIN WITH


60'-0"

20'-0"
PENTHOUSE BASEMENT
FB1

FB1
FB4

FB4
FB4

FB4

FB4

FB4
FB2 FB2
S2 S2 S2 S2 S2
_
BLOCK NO.

FB3 FB3 FB3 FB3 FB3 _


B LOT NO.
FB2 S1 FB2
FB2
TOWN SHIP -

20'-0"
FB1

FB1
FB4

FB4
FB4

FB4

FB4

FB4
SUBJECT
FB2 S2 S2 S2 S2 FB2 FIRST,SECOND AND THIRD
FLOOR BEAM & SLAB PLAN
FB3 FB3 FB3 FB3 FB3

FB2 FB2
A SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
A' DATE

L.S-
75'-0"

83'-0"

1 FIRST,SECOND AND THIRD FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
FB3 FB5 FB3 FB5 FB3
D
FB2 FB2

FB2
FB2
S2 S2

AB1
NOTE
S1 FB2 FB2 S1
S2 Concrete Work

FB2
S2

20'-0"
FB2
f 'c = 2,500 psi (28-days)

FB4

FB4
FB4

FB4
FB1

FB1
FB2 S2 S2 FB2 f y = 50,000 psi
S2
FB2 FB2 FB3

AB1

FB4
FB2

FB2
S1 S1 OWNER
S1
S2
C
FB2 FB3 FB5 FB3 FB3 FB5 FB3 FB2

S1 S1 PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

PENTHOUSE BASEMENT
FB1

FB1
FB4

FB4
FB4

FB4

FB4

FB4
FB2 FB2
S2 S2 S2 S2 S2
_
BLOCK NO.
S1 S1
FB3 FB3 FB3 FB3 FB3 _
B LOT NO.
FB2 S1 FB2
FB2
TOWN SHIP -
S1 S1

20'-0"
FB1

FB1
FB4

FB4
FB4

FB4

FB4

FB4
SUBJECT
FB2 S2 S2 S2 S2 FB2 FOURTH FLOOR BEAM &
SLAB PLAN
S1 S1
FB3 FB3 FB3 FB3 FB3

FB2 FB2
A SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
A' DATE

L.S-
75'-0"

83'-0"

1 FOURTH FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
FB3 FB5 FB3 FB5 FB3
D
FB2 FB2

FB2
FB2
S2 S2

AB1
NOTE
FB2 FB2
S1 S2 S2 S1 Concrete Work
S2

FB2
S2 S2

20'-0"
FB2
f 'c = 2,500 psi (28-days)

FB4

FB4
FB4

FB4
FB1

FB1
FB4
FB2 FB2 f y = 50,000 psi
FB2 FB2 FB2 FB2
FB2 FB2

FB2

FB2
OWNER
FB1

FB1
S2 S2 S2 S2
FB5 S2
FB5
C
FB2 FB3 FB3 FB3 FB3 FB2
S2 S2
FB2

FB2
S1 FB1 FB1 S1
S2 S2 S2 S2 PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

S2 S2 PENTHOUSE BASEMENT
FB1

FB1
FB4
FB4
FB2 FB2 FB3 S2 S2 FB3 FB2 FB2
S2
FB4
FB4

FB4

FB4
FB1 FB1 _
FB2

FB2
BLOCK NO.
S1 S2 S2 S2 S2 S1

FB3 S2 FB3 S2 FB3 _


B LOT NO.
FB2 FB4 S1 FB4 FB2
FB1

FB1
FB2
S2 S2 S2 S2
TOWN SHIP -
FB2 FB2 FB2 FB2

20'-0"
FB1

FB1
FB4

FB4
FB4

FB4

FB4

FB4
SUBJECT
S2 S2 FIFTH AND SIXTH FLOOR
S1 S2 S2 S1 BEAM & SLAB PLAN
FB2 FB3 FB3 FB3 FB3 FB3 FB2
A SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
A' DATE

L.S-
75'-0"

1 FIFTH FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

4'-0"
FB3 FB5 FB3 FB5 FB3
FB2

FB2
FB2

FB2
S2 S2

AB1
NOTE

AB1
FB2 FB2
S1 S2 S2 S1 Concrete Work

FB2
S2

FB2

20'-0"
FB4
FB4

f 'c = 2,500 psi (28-days)

FB4

FB4
FB4

FB1
FB2 FB2 S2 S2 f y = 50,000 psi
FB2 FB2
FB2 FB2
AB1

FB2
FB2
OWNER
FB1

S2 S2

FB1
S2 S2
FB5 S2
FB5

FB2 FB3 FB3 FB3 FB2


FB3
S2 S2
FB2

FB2
S1 S1
S2 S2 S2 S2 PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

PENTHOUSE BASEMENT
FB1

FB4
FB4

FB1
FB2 FB2 FB3 FB3 FB2 FB2
S2 S2 S2
FB4
FB4

FB4

FB4
_
FB2

FB2
S1 BLOCK NO.
S2 S2 S2 S2 S1
FB3 S2 FB3 S2 FB3 _
LOT NO.
FB2 FB4 S1 FB4 FB2
FB1

FB2

FB1
S2 S2 S2 S2
AB1

TOWN SHIP -
FB2 FB2 AB1
FB2 FB2

20'-0"
FB1

FB4
FB4

FB4

FB1
FB4

FB4

FB4
SUBJECT
S2 S2 FIFTH AND SIXTH FLOOR
S1 S2 S2 S1 BEAM & SLAB PLAN
FB2 FB3 FB3 FB3 FB3 FB3 FB2
SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
DATE

L.S-
75'-0"

1 SIXTH FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"
RB1 RB1 RB1 RB1 RB1
D'

4'-0"
RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2
RS1 RS1 RS1 RS1 RS1 RS1 RS1 RS1
RB3
D
RB2 RB2

RB2
RB3 RB4 RB4 RB3

RB2
RS2 RS2 9'-9" 6'-6"
NOTE

AB1
RS1 RB2 RB3 RS1
RS2 Concrete Work

RB2
RB2

20'-0"
RS2 f 'c = 2,500 psi (28-days)

RB4

RB4
RS2
RB4

RB4
AB2

AB2
RB4
RB1

RB1
RS2
RB3 RS2 f y = 50,000 psi
RB2 RB2
AB1 AB1 RB2 RB3 AB1 AB1 AB1 AB1

RB2

RB2
RS1 RS1 RS1 OWNER
RS2

C
RB2 RB3 RB5 RB3 RB3 RB5 RB3 RB2

AB1 AB1 AB1 AB1


RS1 RS1 PROJECT SE EN STORE ED R.C BUILDIN WITH
AB2

AB2
68'-0"

60'-0"

20'-0"
PENTHOUSE BASEMENT
RB1

RB1
RB4

RB4
RB4

RB4

RB4

RB4
RB2 RB2
RS2 RS2 RS2 RS2 RS2
_
AB1 AB1 AB1 AB1 BLOCK NO.
RS1 RS1
RB3 RB3 RB3 RB3 RB3 _
B LOT NO.
RB2 RS1 RB2
RB2
TOWN SHIP -
AB2

AB2
RS1 RS1

20'-0"
RB1

RB1
RB4

RB4
RB4

RB4

RB4

RB4
SUBJECT
RB2 RS2 RS2 RS2 RS2 RB2 ROOF FLOOR BEAM & SLAB
PLAN
RS1 RS1
RB3 RB3 RB3 RB3 RB3
A SCALE 1/16" = 1'-0" SHEET NO.
RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2

RB2
RB2 RB2

4'-0"
RS1 RS1 RS1 RS1 RS1 RS1 RS1 RS1 RS1

A' DATE
RB1 RB1 RB1 RB1 RB1

L.S-
75'-0"
83'-0"

1 ROOF FLOOR BEAM & SLAB PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
RTB1 RTB1 RTB1 RTB1 RTB1
D

RTB1

RTB1
NOTE

RTB2

RTB2
RTB1

RTB1
Concrete Work

20'-0"
f 'c = 2,500 psi (28-days)
RTB2

RTB4

RTB4

RTB4

RTB2
RTB3 RTB3
f y = 50,000 psi

RTB1

RTB1
RTB2

RTB2
OWNER
RTB1 RTB1
C
RTB3 RTB1 RTB3
RTB1
PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

RTB1 RTB1
RTB2

RTB2

RTB2

RTB2

RTB2

RTB2
PENTHOUSE BASEMENT

_
BLOCK NO.

RTB1 RTB1 RTB1 RTB1 RTB1 _


B LOT NO.

TOWN SHIP -

20'-0"
RTB1 RTB1
RTB2

RTB2

RTB2

RTB2

RTB2

RTB2
SUBJECT
ROOF BEAM PLAN

RTB1 RTB1 RTB1 RTB1 RTB1


A
SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
A' DATE

L.S-
75'-0"

1 ROOF BEAM PLAN( roofing )


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
D

NOTE
Concrete Work

20'-0"
f 'c = 2,500 psi (28-days)
f y = 50,000 psi

OWNER

PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

PENTHOUSE BASE ENT

_
BLOCK NO.

_
B LOT NO.

TOWN SHIP -

20'-0"
SUBJECT
BASE PLATE

SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
DATE

L.S-
75'-0"

1 BASE PLATE PLAN (overhead tank)


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
10'-3"
D

NOTE
Concrete Work

20'-0"
f 'c = 2,500 psi (28-days)
f y = 50,000 psi

OWNER

DETAIL-1

PROJECT SE EN STORE ED R.C BUILDIN WITH


58'-021"

20'-0"
60'-0"

PENTHOUSE BASE ENT

_
BLOCK NO.

_
B LOT NO.

TOWN SHIP -

20'-0"
SUBJECT
PURLIN PLAN

[609.60]
2'-0"
SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
DATE

L.S-
75'-0"

1 PURLIN PLAN( roofing )


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"


10'-3" 10'-3"
[3124.20] [3124.20]
D'

4'-0"
D

NOTE
Concrete Work

20'-0"
f 'c = 2,500 psi (28-days)
f y = 50,000 psi

OWNER

PROJECT SE EN STORE ED R.C BUILDIN WITH

20'-0"
60'-0"

PENTHOUSE BASE ENT

_
BLOCK NO.

_
B LOT NO.

TOWN SHIP -

20'-0"
SUBJECT
RAFTER PLAN

SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
DATE

L.S-
75'-0"

1 RAFTER PLAN( roofing )


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4'-0" 16'-3" 16'-0" 10'-6" 16'-0" 16'-3" 4'-0"

D'

4'-0"
D

NOTE
Concrete Work

20'-0"
f 'c = 2,500 psi (28-days)
f y = 50,000 psi

11'-7" OWNER
[3535.40]
C

PROJECT SE EN STORE ED R.C BUILDING WITH


68'-0"

20'-0"
PENTHOUSE BASE ENT

_
BLOCK NO.

_
B LOT NO.

Slope Slope Slope


TOWN SHIP -

20'-0"
SUBJECT
ROOFING PLAN

SCALE 1/16" = 1'-0" SHEET NO.

4'-0"
DATE

L.S-
75'-0"

1 ROOFING PLAN( roofing )


A- SCALE: 1/16" = 1' - 0"
COLUMN SCHEDULE

REINFORCEMENT
TYPE SIZE REMARK CLEAR COVER
MAIN TIE

18" x 18" 12 - 20 mm Ø 10 mm Ø @ 6" c/c Basement to Fourth Floor 1.5"

C-1 16" x 16" 10 - 20 mm Ø 10 mm Ø @ 6" c/c Fourth Floor to Sixth Floor 1.5"

NOTE
14" x 14" 8 - 20 mm Ø 10 mm Ø @ 6" c/c Sixth Floor to Roof Floor 1.5"

fcu = 3625 psi. (G-25) 28days cube strength


18" x 20" 14 - 25 mm Ø 10 mm Ø @ 6" c/c Basement to Second Floor 1.5"
Use ACI standard hooks and bends
16" x 18" 12 - 20 mm Ø 10 mm Ø @ 6" c/c Second Floor to Fourth Floor 1.5" unless otherwise specified.
C-2
16" x 16" 10 - 20 mm Ø 10 mm Ø @ 6" c/c Fourth Floor to Sixth Floor 1.5" fy = 60000 psi.

14" x 14" 8 - 20 mm Ø 10 mm Ø @ 6" c/c Sixth Floor to Roof Floor 1.5"


PROJECT
20" x 20" 16- 25 mm Ø 10 mm Ø @ 6" c/c Basement to Second Floor 1.5"
7-STOREYED
10 mm Ø @ 6" c/c Second Floor to Fourth Floor 1.5"
PENTHOUSE+BASEMENT
18" x 18" 14- 20 mm Ø
R.C.C. BUILDING
C-3
16" x 16" 12- 20 mm Ø 10 mm Ø @ 6" c/c Fourth Floor to Sixth Floor 1.5"
OWNER
14" x 14" 10- 20 mm Ø 10 mm Ø @ 6" c/c Sixth Floor to Roof Floor 1.5"

BLOCK NO. -

LOT NO. -

TOWN SHIP

C-1 ( 18"x 18" ) C-1 ( 16"x 16" ) C-1 ( 14"x 14" ) SHEET NO.
12 - 20 mm Ø 10 - 20 mm Ø 8 - 20 mm Ø
TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c
Basement to Fourth Floor Fourth Floor to Sixth Floor Sixth Floor to Roof Floor SCALE 1 : 18

DATE

REVISED

DRAWING TITLE

C-2 ( 16"x 16" ) C-1 ( 14"x 14" )


C-2 ( 18"x 20" ) C-2 ( 16"x 18" )
10 - 20 mm Ø 8 - 20 mm Ø SCHEDULES
14 - 25 mm Ø 12 - 20 mm Ø TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c
TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c Sixth Floor to Roof Floor
Fourth Floor to Sixth Floor
Basement to Second Floor Second Floor to Fourth Floor

DRAWN BY. CHECKED BY.

Project No. ##

C-3 ( 18"x 18" ) C-2 ( 16"x 16" ) C-1 ( 14"x 14" )


C-3 ( 20"x 20" ) 14 - 20 mm Ø 12 - 20 mm Ø 10 - 20 mm Ø
16 - 25 mm Ø TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c TIES 10 mmØ @ 6" c/c
TIES 10 mmØ @ 6" c/c Second Floor to Fourth Floor Fourth Floor to Sixth Floor Sixth Floor to Roof Floor
Basement to Second Floor
MAT SCHEDULE

REINFORCEMENT

TYPE SIZE DEPTH PARALLEL TO PARALLEL TO REMARK


BELOW NGL
SHORT SIDE LONG SIDE

20mmØ Steels @ 6" c/c 20mmØ Steels @ 6" c/c Top Layer
NOTE
Mat Footing 68'-0"x83'-0"x3'-0" 8'-0"

20mmØ Steels @ 6" c/c 20mmØ Steels @ 6" c/c Bottom Layer fcu = 3625 psi. (G-25) 28days cube strength

Use ACI standard hooks and bends


unless otherwise specified.

MAT BEAM SCHEDULE fy = 60000 psi.

SUPPORTS MIDDLE STIRRUP PROJECT


TYPE SIZE Torsion Steels REMARK
7-STOREYED
TOP BOTTOM TOP BOTTOM within 2H Mid-Span
PENTHOUSE+BASEMENT
R.C.C. BUILDING
MB 24" x 30" 6 - 20mm Ø 6 - 20mm Ø 6 - 20mm Ø 6 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c
OWNER

BLOCK NO. -

SLAB,STAIR,RAMP SCHEDULE LOT NO. -

MIDDLE SUPPORTS TOWN SHIP


TYPE THICKNESS LOCATION CLEAR COVER REMARK
TOP BOTTOM BOTTOM TOP CONTINUOUS TOP DISCONTINUE
SHEET NO.
SHORTER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C General Arrangement
S-2 4.5" 0.75" ( See Detail Arrangement Plan )
SCALE 1 : 18
LONGER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C Two Way Floor Slab

DATE
SHORTER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C General Arrangement
S-1 4.5" 0.75" ( See Detail Arrangement Plan ) REVISED
LONGER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C One Way Floor Slab
DRAWING TITLE
SHORTER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C General Arrangement
RS-2 4.0" 0.75" ( See Detail Arrangement Plan )
LONGER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C Two Way Roof Floor Slab
SCHEDULES

SHORTER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C General Arrangement
RS-1 4.0" 0.75" ( See Detail Arrangement Plan )
LONGER SPAN 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C 10mm Ø @6" C/C One Way Roof Floor Slab
DRAWN BY. CHECKED BY.
VERTICAL STEEL 16mm Ø @ 7" C/C
General Arrangement
W-1 9" 1.5" ( See Detail Arrangement Plan )
HORIZONTAL STEEL 12mm Ø @ 7" C/C Shear Wall Project No. ##

MAIN STEEL 16mm Ø @ 7" C/C


General Arrangement
Ramp 9" ( See Detail Arrangement Plan )
DISTRIBUTION STEEL 12mm Ø @ 7" C/C Ramp Slab

MAIN SPAN 12mm Ø @ 3.0" C/C 12mm Ø @ 3.0" C/C 12mm Ø @ 3.0" C/C 12mm Ø @ 3.0" C/C 12mm Ø @ 3.0" C/C
General Arrangement
Stair 5.0" 1" ( See Detail Arrangement Plan )
DISTRIBUTION Distribution Steel 10mm Ø @ 6" C/C For Top & Bottom Layers Main Stair
TYPE

GB-1

GB-2
SIZE
13B
GROUND BEAM SCHEDULE

9" x 12"

12" x 14"
TOP
SUPPORTS

3 - 16mm Ø

4 - 20mm Ø
BOTTOM

3 - 16mm Ø

3 - 20mm Ø
TOP
MIDDLE

3 - 16mm Ø

3 - 20mm Ø
BOTTOM

3 - 16mm Ø

4 - 20mm Ø
Torsion Steels

-
within 2H

10 mm Ø @ 4" c/c

10 mm Ø @ 4" c/c
STIRRUP

Mid-Span

10 mm Ø @ 6" c/c

10 mm Ø @ 6" c/c
CLEAR COVER

1.5

1.5
NOTE

fcu = 3625 psi. (G-25) 28days cube strength

GB-3 12" x 16" 4 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5 Use ACI standard hooks and bends
unless otherwise specified.

GB-4 12" x 20" 5 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 5 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5 fy = 60000 psi.

Lintel 9" x 12" 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø - 6.5 mm Ø @ 6" c/c 6.5 mm Ø @ 6" c/c 1.5
PROJECT

7-STOREYED
PENTHOUSE+BASEMENT
R.C.C. BUILDING
FLOOR BEAM SCHEDULE
OWNER
SUPPORTS MIDDLE STIRRUP
TYPE SIZE Torsion Steels CLEAR COVER
BOTTOM BOTTOM Mid-Span BLOCK NO. -
TOP TOP within 2H

LOT NO. -
FB-1 9" x 12" 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5
TOWN SHIP
FB-2 12" x 14" 3 - 20mm Ø 3 - 20mm Ø 3 - 20mm Ø 3 - 20mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

5 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 5 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5 SHEET NO.
FB-3 12" x 16"

FB-4 12" x 20" 5 - 20mm Ø 5 - 20mm Ø 5 - 20mm Ø 5 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5 SCALE 1 : 18

DATE
FB-5 14" x 20" 6 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 6 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

REVISED
AB1 6" X 4" 2 - 16mm Ø 1.5
DRAWING TITLE
AB2 9" X 16" 4 - 20mm Ø 3 - 20mm Ø 3 - 20mm Ø 4 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

SCHEDULES
ROOF BEAM SCHEDULE

SUPPORTS MIDDLE STIRRUP


TYPE SIZE Torsion Steels CLEAR COVER DRAWN BY. CHECKED BY.
TOP BOTTOM TOP BOTTOM within 2H Mid-Span

RB-1 9" x 9" 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5 Project No. ##

RB-2 9" x 12" 3 - 20mm Ø 3 - 20mm Ø 3 - 20mm Ø 3 - 20mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

RB-3 12" x 16" 4 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø - 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

RB-4 12" x 18" 6 - 20mm Ø 4 - 20mm Ø 4 - 20mm Ø 6 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5

RB-5 12" x 20" 7 - 20mm Ø 5 - 20mm Ø 5 - 20mm Ø 7 - 20mm Ø 2 - 16mm Ø 10 mm Ø @ 4" c/c 10 mm Ø @ 6" c/c 1.5
UP DN

DRAWING NO: ISSUE /DATE: REMARK:


PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

D'
D

B
UP DN

A
A'
DRAWING NO: ISSUE /DATE: REMARK:
PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

UP DN

DRAWING NO: ISSUE /DATE: REMARK:


PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

UP DN

DRAWING NO: ISSUE /DATE: REMARK:


PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

D'
D

B
UP DN

A
A'
DRAWING NO: ISSUE /DATE: REMARK:
PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

UP DN

DRAWING NO: ISSUE /DATE: REMARK:


PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

D'
D

B
UP DN

A
A'
DRAWING NO: ISSUE /DATE: REMARK:
PROJECT TITLE :
REVISION
THIS DRAWING IS SOLE
PROJECT OWNER : TOTAL AREA : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
1' 1 2 3 4 5 6 6'

D'
D

A
A'

DRAWING NO: ISSUE /DATE: REMARK:


PROJECT TITLE :
REVISION
TOTAL AREA :
THIS DRAWING IS SOLE
PROJECT OWNER : REVISION /DATE:
COPYRIGHT OF CITIZENS ID ,LTD
PLOT DATE: THE DRAWING IS NOT TO SCALE
DRAWING TILE :
AND SHOULD BE CHECKED ON SITE.
SCALE : DRAWN BY : FILE NAME : CHECKED BY:
115'-0"
20'-0" 75'-0" 20'-0"
25'-6"

NOTE
Concrete Work
f 'c = 2,5000 psi (28-days)
f y = 50,000 psi
OWNER
_
Fence Line

Fence Line
PROJECT SEVEN STOREYED R.C BUILDING WITH
106'-0"

BUILDING AREA PENTHOUSE + BASEMENT


_

22'-821"
BLOCK NO.
_
LOT NO.
SEE DETAIL 1
TOWN SHIP -
SUBJECT
EXPANSION JOINT PLAN
SCALE 3/32" = 1'-0" SHEET NO.
DATE
11'-6" L.S-
20'-0" 75'-0" 20'-0"
EXPANSION JOINT PLAN
26'-0" 20'-0" 26'-0"
+4'-0" Ground Floor Level
TYPICAL PARAMETER RETAINING WALL TOP LEVEL +1'-0" Pavement Level
6'' Thk G30 Concrete
Arm of RCC retaining wall under ramp slab
17 Degree (12":4") ±0'-0" Pavement Level
18" Thk; RCC footing
12" Thk; Key of footing
-8'-0" Pavement Level -8'-0" Basement Floor Level
9" Thk; Brick Retaining Wall 9" Thk; Brick Retaining Wall
RAMP SECTION
NOTE
Concrete Work
f 'c = 2,500 psi (28-days)
f y = 50,000 psi
Ø10mm @ 10'' C/C
Ø16mm Dowel @ 12'' C/C
OWNER
Plastic Sleeve
_
121 ''

12'' 12''

6''
3''
Seelant filled joint PROJECT SEVEN STOREYED R.C BUILDING WITH
PENTHOUSE + BASEMENT
EXPANSION JOINT DETAIL
_
BLOCK NO.
_
LOT NO.
TOWN SHIP -
Ø10mm @ 10'' C/C
Ø16mm Dowel @ 12'' C/C Epoxy Grouting
SUBJECT
Epoxy Grouting RAMP DETAIL

121 ''
12'' 6''

6''

3''
16mm Tie Bar SCALE 1/16" = 1'-0" SHEET NO.
Seelant filled joint
Ø20mm Drill Hole
DATE
SECTION
L.S-
JOINT DETAIL 1(Basement Slab to Ramp)
4'-0"
8'-0"

NOTE
Concrete Work
f 'c = 3,200 psi(G-30) (28-days)
f y = 50,000 psi
PIT DRAINAGE RETAINING WALL PLAN OWNER
_
PROJECT SEVEN STOREYED R.C BUILDING WITH
PENTHOUSE + BASEMENT
_
BLOCK NO.
_
LOT NO.
1'-0'' 4'-0" TOWN SHIP -
12'' Thk; RC Wall
BASEMENT LEVEL
Vert. Ø16mm@ 6''c/c
SUBJECT

6'-0"
Hor. Ø12mm@ 6''c/c
1'-0" SHEET NO.
12'' Mat Foundation SCALE
3'' Thk; Lean Concrete
DATE

1'-0''
L.S-
PIT DRAINAGE RETAINING WALL SECTION
9''x9'' RC Beam
Ø16mm @ 4 Nos NGL
4'-0"

Tie Ø6.5mm@6'' c/c


Ø12mm@6'' c/c(Both Way)
9'' Thk; Footing
3'' Thk; Lean Concrete
ISO FOOTING PLAN
NOTE
Concrete Work
f 'c = 3,200 psi(G-30) (28-days)
20'-0" f y = 50,000 psi
10'-0" 10'-0"
OWNER
Ø16mm @ 2 Nos ( Top & Bot)
_
Ø6.5mm@6''c/c (Stirrup)
C1 C1 C1
PROJECT SEVEN STOREYED R.C BUILDING WITH
PENTHOUSE + BASEMENT
GROUND BEAM SECTION _
BLOCK NO.
_
LOT NO.
TOWN SHIP -
COLUMNS SCHEDULE
9"
SUBJECT
9"
LEVEL
9inx9in
4-Ø16mm (Main Steel)
1-6.5mmØ@ 6inc/c (Tie)
LEVEL C1
TYPE
SCALE SHEET NO.
GROUND BEAM SCHEDULE Clear Cover = 1.5"
DATE
Size Steel Reinforcement Torsion Steel Shear Reinforcement (Stirrup)
Type
(inxin) Position Left End Support Mid Span Right End Support (Additional) Within 2h Mid Span
Remark
L.S-
Top 2-Ø16mm 2-Ø16mm 2-Ø16mm
GB1 9x9 - 6.5mmØ@6"c/c 6.5mmØ@6"c/c -
Bottom 2-Ø16mm 2-Ø16mm 2-Ø16mm
STEEL SCHEDULE
1'-0"
Vert. Ø16mm@ 8'' c/c
Hor & Vert Ø3'' weep hole @ 3' c/c NGL NOTE
Hor. Ø16mm@ 6'' c/c
Concrete Work
f 'c = 3,200 psi(G-30) (28-days)

8'-0"
f y = 50,000 psi

3'-6"
Vert.Ø16mm@ 4'' c/c(up to 3'-6'') Ø16mm@ 4'' c/c(Outer Bar) OWNER
_
1'-6'' BASEMENT LEVEL 1'-6"

3'-0"
1'-6"
PROJECT SEVEN STOREYED R.C BUILDING WITH
RW BASE

1'-0"
Ø12mm@ 10'' c/c PENTHOUSE + BASEMENT
2'-0" 1'-3" 3'-2"
6'-9" _
BLOCK NO.
_
LOT NO.
TOWN SHIP -
SUBJECT
TYPICAL PARAMETER RETAINING WALL SECTION FOR BASEMENT LEVEL
SCALE SHEET NO.
DATE
L.S-
3'' Thk; Sill Beam NOTE
Concrete Work
f 'c = 3,200 psi(G-30) (28-days)
f y = 50,000 psi
9''x9'' RC Column(C1)
3'' Thk; Sill Beam
10mm@2nos (Top & Bot)
1
2 '' Thk; 1:4 Cement Mortor
OWNER

7'-0"
_

3'-6"
PROJECT SEVEN STOREYED R.C BUILDING WITH
PENTHOUSE + BASEMENT
NGL
_
BLOCK NO.

8'-0"
_
RC RETAINING WALL LOT NO.
TOWN SHIP -
SUBJECT
BASEMENT LEVEL
SCALE SHEET NO.
TYPICAL 4 21 '' THK; BRICK FENCE WALL DETAIL DATE
L.S-
20'-0" 75'-0" 20'-0"
NOTE
Concrete Work
f 'c = 2,5000 psi (28-days)
f y = 50,000 psi
OWNER
_
PROJECT SEVEN STOREYED R.C BUILDING WITH
75'-0"

3'-0" 4'-0" 4'-0" 3'-0"


12'-8" PENTHOUSE + BASEMENT
_
8'-0"

8'-0"

8'-0"
BLOCK NO.
_
LOT NO.
TOWN SHIP -
SUBJECT
BUILDING LAYOUT PLAN
SCALE 3/32" = 1'-0" SHEET NO.
20'-0" 75'-0" 20'-0" DATE
L.S-
RETAINING WALL PLAN
COLUMNS SCHEDULE Clear Cover = 2"
9"
9"
LEVEL
9inx9in
4-Ø16mm (Main Steel)
1-6.5mmØ@ 6inc/c (Tie)
LEVEL C1
TYPE
BEAM SCHEDULE
Clear Cover = 2" NOTE
Size Steel Reinforcement Torsion Steel Shear Reinforcement (Stirrup) Concrete Work
Type Remark
(inxin) Position Left End Support Mid Span Right End Support (Additional) Within 2h Mid Span f 'c = 3,200 psi(G-30) (28-days)
Top 2-Ø16mm 2-Ø16mm 2-Ø16mm f y = 50,000 psi
GB1 9x9 - 6.5mmØ@6"c/c 6.5mmØ@6"c/c -
Bottom 2-Ø16mm 2-Ø16mm 2-Ø16mm
OWNER
_
PARAMETER RETAINING WALL SCHEDULE Clear Cover = 2"
Thickness
Type Layer Steel Reinforcement
(in) PROJECT SEVEN STOREYED R.C BUILDING WITH
Horizontal 16mmØ@ 6in c/c each face PENTHOUSE + BASEMENT
WALL 12 to 18 Vertical(Back Fill Side) 16mmØ@ 4in c/c each face
16mmØ@ 4in c/c each face _
Vertical(Other Side) BLOCK NO.
_
LOT NO.
PIT DRAINAGE RETAINING WALL SCHEDULE Clear Cover = 2"
Type
Thickness
Layer Steel Reinforcement TOWN SHIP -
(in)
Horizontal 12mmØ@ 6in c/c each face
WALL 12 SUBJECT
Vertical 16mmØ@ 6in c/c each face
MAT FOOTINGS SCHEDULE SCALE SHEET NO.
Footing Clear Cover = 3"
Size Steel Reinforcement
Type Layer Remark DATE
Length Width Thickness Short Direction Long Direction
Top 16mmØ @ 6in C/C 16mmØ @ 6in C/C L.S-
F1 10'-0'' 6'-0'' 12"
Bottom 16mmØ @ 6in C/C 16mmØ @ 6in C/C
EMERGENCY STEEL STAIR

STRUCTURAL DRAWING

SEPT;,2020
STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

ADDITIONAL EMERGENCY
STEEL STAIR
STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

ADDITIONAL EMERGENCY
STEEL STAIR
STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

ADDITIONAL EMERGENCY
STEEL STAIR
A B C D

2
F1 F1 F1 F1

Foundation Plan

STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

ADDITIONAL EMERGENCY
STEEL STAIR

A B C D

Retaining Wall Plan


A B C D

SC1 B1 SC1 B1 SC1 B1 SC1


2
D-2
STB
D-7
STB

B1

B1

B1

B1
D-1
1
GB3 GB3 GB3

Ground Beam Plan B1-300mm x 300mm


SC1-300 x 300mm STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

A B C D ADDITIONAL EMERGENCY
STEEL STAIR

SC1 x SB1 SC1 D-4 SC1 SB1 SC1


2 SB1
Angle-1 Angle-1
STB
STB

SB1

SB1
Angle-1
SB1

Angle-1
SB1

D-5

DS
DS

SB1
Angle-1

Angle-1
Angle-1

SB2
DS

DS

Angle-1 Angle-1
D-6
1 FB5
C2 FB3 C2 FB5
D-3 x

Stair Landing Beam Plan(1st FL. & Roof FL.)


SB1-UB-150mm x 75mm X 14 kg/m
SB2/STB-UB-150mm x 75mm X 14 kg/m
SC1-UC-200mm x 100mm X 18.2 kg/m
Angle-1-75mm x 75mm X 3.4 kg/m
FOUNDATION SCHEDULE
Size (ft) REINFORCEMENT

Type TOP BAR BOTTOM BAR REMARK


L B H SHORTER LONGER SHORTER LONGER
(mm) (mm) (mm) DIRECTION DIRECTION DIRECTION DIRECTION
F1 1000 1000 225 - - T12 @ 150mm c/c T12 @ 150mm c/c Sqare Footing

SUMMARY FOR COLUMN DETAIL STRUCTURAL STRENGTH:


Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)
COLUMN TYPE FOUNDATION GROUND FLOOR TO
TO GROUND FLOOR ROOF FLOOR
ADDTIONAL EMERGENCY
STEEL STAIR

SIZE
&
SC1 DETAIL

MAIN STEEL 8-16mm Ø Rebar

2Ties -10mm Ø @ 150mm UC 200mm X 100mm X 18.2 kg/m


TIES
(clear spacing)
BEAM SCHEDULE
MAIN REINFORCEMENT SIDE BAR REMARK
STIRRUP
TYPE SIZE (mm) END-SPAN (LEFT) MID-SPAN END-SPAN (RIGHT) OR
TOP BOTTOM TOP BOTTOM TOP BOTTOM TORSION WITHIN 2h MID-SPAN
GROUND
LEVEL
GB1 (300x300) 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ 3-16mmØ - 1-8mmØ@100mmc/c 1-8mmØ@150mmc/c
SB1 UB 150X75X14 kg/m
SB2 UB 150X75X14 kg/m
STB UB 150X75X14 kg/m
Angle-1 L-75mmX75mmX3.4kg/m

SLAB SCHEDULE

Type Thickness
(mm)

Wire Mesh 3
STRUCTURAL STRENGTH:
Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)

ADDITIONAL EMERGENCY
B STEEL STAIR
4nos. M20 G8.8BOLT
G.F.L 8mm Fillet
weld all round
12mm thk: base plate
Detail - 2
0-Level Scale 1:16

SC1
UC 200X100X18.2kg/m

8mm Fillet weld all round

12mm thk: base plate

Section a-a
1 2 1 2

Existing RC Column

T16 PENETRATION
WITH EPOXY Wire Mesh with 3mm thick;

SB2

B1 SB1
C2 SC1
FB5
DECKING SLAB
Ground Beam Section(D-1) SECTION X-X

M20 dia; HILTI


CHEMICAL BOLT
A M20 dia; HILTI
B
CHEMICAL BOLT 8 nos. M16-G8.8 bolt
8mm thk; all
8mm thk; all round welding
round welding
8mm thk; all round welding
12mm thk; steel plate 10mm thk; steel plate STRUCTURAL STRENGTH:
12mm thk; steel plate Fy=36ksi ,Fu =58 ksi(Steel Member)
A SB1 SB1 f'c =2500psi ,fy= 40000psi(RC Member)
A A
Existing RC Beam
B
SC1

SECTION 3A-3A ADDITIONAL EMERGENCY


DETAIL-3(D-3) DETAIL-4(D-4) SECTION 4A-4A STEEL STAIR

C B
10mm thk; steel plate
10mm thk; steel plate
SB1 SB2
4 nos. M16-G8.8 bolt
4 nos. M16-G8.8 bolt 4 nos. M16-G8.8 bolt
8mm thk; all round welding 4 nos. M16-G8.8 bolt
8mm thk; all round welding
8mm thk; all round welding
A A SB1
8mm thk; all round welding

10mm thk; steel plate


C SB1
B 10mm thk; steel plate
SECTION 5A-5A
SECTION 5B-5B
SECTION 4B-4B SECTION 4C-4C DETAIL-5(D-5)

FB3 FB3 STB


4 nos. M20-G8.8 bolt
A SB2 8mm thk; all round welding
M16 dia; HILTI M16 dia; HILTI
CHEMICAL BOLT CHEMICAL BOLT
8mm thk; all round welding 12mm thk; steel plate
8mm thk; all round welding
SB2
12mm thk; steel plate 12mm thk; steel plate
B1
A
DETAIL-6(D-6) SECTION 6A-6A
DETAIL-7(D-7)
B C 6 nos. M16-G8.8 bolt

12mm thk; steel plate

UC 200X100

DETAIL-8(D-8)
FL. COLUMN SPLICE

SB1 ALL ROUND FILLET


WELDING
D-7
6mm thk; ALL ROUND WELDING
UC 200X100

STRUCTURAL STRENGTH:
6 nos. M16-G8.8 bolt Fy=36ksi ,Fu =58 ksi(Steel Member)
f'c =2500psi ,fy= 40000psi(RC Member)
12mm thk; steel plate

Angle 62X62X4 mm THK;


ADDITIONAL EMERGENCY
STEEL STAIR

UC 200X100

SECTION 8A-8A
(STB)
2NOs. UB 150X75 x14 kg/m

FL.
ALL ROUND FILLET
WELDING SB1
STAIR SECTION
Ø100mm Sprinkler Pipe T/A
1' 1 2 3 4 5 6 6'

Ø25
Ø50 Ø25
Ø25 Ø25 Ø50 Ø50 Ø40 Ø40 Ø40

Ø32
Ø40

Ø25
Ø80

Ø25
Ø25 Ø25 Ø32 Ø25 Ø25

Ø80
Ø25 Ø25 Ø32 Ø25 Ø25

Ø80
Ø25 Ø25 Ø32 Ø25 Ø25

Ø80
Ø50
D3

Ø25

Ø25

Ø25

Ø32
UP
Ø25

Ø25 Ø25

Ø50

Ø25
Ø25

Ø25

Ø25

Ø25
Ø32

Ø25
Ø40 Ø40 Ø40

-3' -3'
Level Level

1 BASEMENT
A- SCALE: 1/16" = 1' - 0"
412'-9" 406'-5" 266'-8" 406'-5"
412'-9"

275'-1" 302'-5" 70'-3"

508'-0"
S
1524'-0"

UP DN

508'-0"
412'-9" 406'-5" 266'-8" 406'-5" 412'-9"

1 GROUND FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
412'-9" 406'-5" 266'-8" 406'-5" 412'-9"

182'-0" 190'-8" 275'-1"


D'

101'-7"
D

157'-2"
269'-0"
87'-10"

508'-0"
S

203'-2"

2"
234'-111
C
1524'-0"

508'-0"
UP DN

508'-0"
A

101'-7"
A'
2108'-212"

1 1st & 3rd FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953


D'

1219
D

1901
6096

6096
S

C
18288

6096
B
UP DN

6096
A

1219
A'

25298

1 2nd & 4th Floor Plan


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953


D'

1219
C1 C1
3301 3301 1016
D

6096
S

C
18288

6096
B
UP DN

6096
C1 C1
A

1222
A'

25298

1 FIFTH FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4953 4877 3200 4877 4953

D'

1219
D

S
S

6096
S

C
S

S
18288

6096
S S

B
UP DN

6096
S

1222
A'

25298

1 SIXTH FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
247'-8" 406'-5" 1
266'-82" 406'-5" 247'-8"

D'
D
Legends
S
Sprinkler Point

Fire Hose Reel


C
Landing Valve

E- Bell & Manual Call pnt

S
Smoke Detector

1
A
266'-82" 406'-5" 247'-8"

247'-8" 406'-5"

A'

1 PENTHOUSE FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
412'-9" 406'-5" 266'-8" 406'-5"
412'-9"

275'-1" 302'-5" 70'-3"

CU-GF-02
FAL 300x200 C/W CU-GF-01
CU-GF-03
FAL 300x200 C/W INS SCREEN FAL 300x200 c/w INSECT SCREEN
INS SCREEN
Ø100 PVC Ø100 PVC

FAF-G-01
300 CMH EAF-GF-03
Ø100 PVC FAG 200x200 EAF-GF-01
80 CMH
EAF-GF-02
80 CMH 80 CMH
EAF-GF-04
80 CMH
EAF-GF-05
80 CMH
C/W V.D
FAD 150 mm
FCU-GF-02
3.52KW

FCU-GF-03
3.52KW

508'-0"

508'-0"
FCU-GF-01 FCU-GF-09 KITCHEN HOOD By Owner
4.5KW 4.5KW
Ø100 PVC KEAD

FCU-GF-07
7.1KW

Ø100 PVC

90'-6"
1524'-0"

FCU-GF-06 FCU-GF-08
7.1KW 4.5KW

FCU-GF-04
5.6KW
AIR CURTAIN BY OTHER

DN

FCU-GF-05
5.6KW

508'-0"
RISER WALL BY OTHER FAD 350x350
SLAB OPENING BY OTHER

FAG 200x200 C/W V.D


@300 CMH
UP
412'-9" 406'-5" 266'-8" 406'-5" 412'-9"

1 GROUND FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953

2184 2288 3301


D'

1219
FAL 300x200 C/W FAL 300x200 C/W FAL 300x200 c/w INSECT SCREEN
INS SCREEN INS SCREEN
Ø100 PVC Ø100 PVC D

1886
FAF-1F-01
300 CMH
Ø100 PVC FAG 200x200 EAF-1F-01 EAF-1F-02 EAF-1F-03 EAF-1F-04 EAF-1F-05

3228
80 CMH 80 CMH 80 CMH 80 CMH 80 CMH
FAD Ø150mm C/W V.D

6096
1054

CU-1F-01
FCU-1F-01 FCU-1F-11 FCU-1F-10
FCU-1F-02
4.5KW 4.5KW 5.6KW
4.5KW

2438

CU-2F-01
2820
Ø100 PVC

T/A

C
FCU-1F-09
7.1KW

FCU-1F-06
5.6KW
Ø100 PVC
18288

6096
FCU-1F-03
9KW

Ø100 PVC

@300 CMH
UP DN

Ø100 PVC

6096
FCU-2F-07 FCU-2F-08
FCU-1F-04 FCU-1F-05 5.6KW 5.6KW
5.6KW 5.6KW

FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

1219
A'

25298

1 FIRST FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953


D'

1219
FAL 300x200 C/W FAL 300x200 C/W FAL 300x200 c/w INSECT SCREEN
INS SCREEN INS SCREEN
Ø100 PVC Ø100 PVC D

1901
FAF-2F-01
300 CMH EAF-2F-01 EAF-2F-02 EAF-2F-03 EAF-2F-04 EAF-2F-05
Ø100 PVC FAG 200x200 80 CMH 80 CMH 80 CMH 80 CMH 80 CMH

FAD Ø150mm C/W V.D

6096

6096
FCU-2F-01
4.5KW FCU-2F-02
4.5KW FCU-1F-11
4.5KW

FCU-2F-10
5.6KW
Ø100 PVC
T/B

C
Ø100 PVC

FCU-2F-06 FCU-2F-09
5.6KW 7.1KW
18288

6096
FCU-2F-03
9KW

B
Ø100 PVC

UP DN

FCU-2F-07 FCU-2F-08
5.6KW 5.6KW

6096
FCU-2F-04 FCU-2F-05
5.6KW 5.6KW

FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

1219
A'

25298

1 SECOND FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4953 4877 3200 4877 4953

D'
2184 2288 3301

1219
FAL 300x200 C/W FAL 300x200 C/W FAL 300x200 c/w INSECT SCREEN
INS SCREEN INS SCREEN
Ø100 PVC Ø100 PVC D
FAF-3F-01
300 CMH FAG 200x200
Ø100 PVC

3228
EAF-3F-01 EAF-3F-02 EAF-3F-03 EAF-3F-04 EAF-3F-03
EAF-3F-05
C/W V.D 80 CMH 80 CMH 80 CMH 80 CMH 80 CMH
FAD Ø150mm

6096
CU-3F-01
FCU-3F-01 FCU-3F-02
4.5KW 4.5KW FCU-3F-11
4.5KW 1054
2438

CU-4F-01
2312
FCU-3F-10
Ø100 PVC

229
5.6KW

T/A
4316 C

229

229

229
229
FCU-3F-09
7.1KW

FCU-3F-06 Ø100 PVC


FCU-3F-03 5.6KW
9KW
18288

6096
229
B
229

229
Ø100 PVC
@300 CMH
UP DN
FCU-3F-07
5.6KW
FCU-3F-05 FCU-3F-08
5.6KW 5.6KW
FCU-3F-04
5.6KW

6096
FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

1219
A'

25298

1 THIRD FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953


D'

1219
FAL 300x200 C/W FAL 300x200 C/W FAL 300x200 c/w INSECT SCREEN
INS SCREEN INS SCREEN
Ø100 PVC Ø100 PVC D

1901
FAF-1F-01
300 CMH EAF-4F-04 EAF-4F-05
FAG 200x200 80 CMH 80 CMH

3228
EAF-4F-01 EAF-4F-02
80 CMH EAF-4F-03
Ø100 PVC Ø100 PVC C/W V.D 80 CMH 80 CMH 80 CMH
FAD Ø150mm

6096
FCU-4F-01 FCU-4F-02
4.5KW FCU-4F-11
4.5KW 4.5KW
3451 2390 3451

Ø100 PVC FCU-4F-10


5.6KW
T/B

C
FCU-4F-09
9KW

Ø100 PVC
18288

6096
FCU-4F-08
5.6KW

FCU-4F-03
9KW

204

203
Ø100 PVC
@300 CMH
UP DN

6096
FCU-4F-06 FCU-4F-07
FCU-4F-04 5.6KW 5.6KW
5.6KW FCU-4F-05
5.6KW

FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

1219
A'

25298

1 FOURTH FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'

4953 4877 3200 4877 4953


D'

1219
C1 C1
FAL 300x200 C/W FAL 300x200 C/W FAL 300x200 c/w INSECT SCREEN 3301 3301 1016
INS SCREEN INS SCREEN
Ø100 PVC Ø100 PVC D
FAF-1F-01
300 CMH

FAD Ø150mm
Ø100 PVC EAF-5F-01 EAF-5F-02 EAF-5F-03 EAF-5F-04 EAF-5F-05
80 CMH 80 CMH 80 CMH 80 CMH 80 CMH
FCU-5F-02
4.5KW

6096
FAL 300x200 c/w INSECT SCREEN
FCU-5F-01
4.5KW FCU-5F-10
4.5KW

CU-5F-01

FAF-1F-01
300 CMH
Ø100 PVC
FAD Ø150mm
C

Ø100 PVC
18288

6096
FCU-5F-08
4.5KW
FCU-5F-09
7.1KW

FCU-5F-03
7.1KW

Ø100 PVC
B
UP DN

6096
FCU-5F-05
FCU-5F-06 FCU-5F-07
FCU-5F-04 4.5KW
4.5KW 4.5KW
4.5KW

FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

C1 C1
A

1222
A'

25298

1 FIFTH FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
4953 4877 3200 4877 4953
FAL 300x200 c/w INSECT SCREEN CU-6F-11
D'

1219
CU-6F-01 CU-6F-05

CU-6F-06 D
FCU-6F-01
5.28KW KITCHEN HOOD By Owner FAF-6F-01
300 CMH

FAD Ø150mm

FAG 200x200 C/W V.D

6096
FCU-6F-06
3.6KW FCU-6F-05
2.64KW

EAF-6F-01
160 CMH

FCU-6F-11
5.42KW CU-6F-07
Ø100 KEAD
CU-6F-02
Ø100 PVC CU-6F-08
EAF-6F-02
200 CMH Ø100 PVC
CU-6F-03
Ø100 KEAD EAF-6F-07
Ø100 KEAD 160 CMH

KITCHEN HOOD By Owner C

FCU-6F-07
5.42KW
FCU-6F-02 KITCHEN HOOD By Owner
5.28KW
18288

6096
FCU-6F-03
5.28KW FCU-6F-08
KITCHEN HOOD By Owner 2.64KW

EAF-6F-06
180 CMH

KITCHEN HOOD By Owner

Ø100 KEAD
EAF-6F-05
160 CMH
B
CU-6F-09
Ø100 PVC
EAF-6F-03 @300 CMH
CU-6F-04 200 CMH UP DN Ø100 KEAD CU-6F-10

Ø100 PVC

EAF-6F-04
160 CMH

6096
FCU-6F-10
FCU-6F-09 3.52KW
3.6KW

FCU-6F-04
5.28KW FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

1222
A'

25298

1 SIXTH FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
2972 4877 3200 4877 2972

FAL 300x200 c/w INSECT SCREEN


D'

T/A
T/A
D
FAF-PF-01
300 CMH
EAF-PF-01 EAF-PF-02
240 CMH 240 CMH
FAD Ø150mm

FAG 200x200 C/W V.D

2100
T/A

FCU-PF-08
FCU-PF-01 5.41KW FCU-PF-05
8.21KW 8.21KW

T/A T/A

FCU-PF-02 FCU-PF-04 FCU-PF-06


8.21KW 8.21KW 8.21KW

T/A

178
T/A
T/A

B
178

FCU-PF-03 FCU-PF-07
8.21KW 8.21KW

FAD 350x350
RISER WALL BY OTHER
SLAB OPENING BY OTHER

A
2972 4877 3200 4877 2972
A'

1 PENTHOUSE FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"
1' 1 2 3 4 5 6 6'
247'-8" 406'-5" 266'-81
2" 406'-5" 247'-8"

D'
D

FAF -RF-01
3000CMH

Fresh Air Intake with SS Mesh

SLAB OPENING BY OTHER

A
266'-81
2" 406'-5" 247'-8"

247'-8" 406'-5"

A'

1 ROOF FLOOR PLAN


A- SCALE: 1/16" = 1' - 0"

You might also like