You are on page 1of 3

Treatability Study Report/ Analysis Report

Description of Sample : Vashista Produced Water Sample


Date of Sampling : 12/06/21 Sample Receipt Date : 26/06/21
Sample Collected by : ONGC Sample Quantity : 100 Liters
Date of Testing : 26/06/21 Packing/Seal :
Sampling procedure :

Company Name : ONGC - KAKINADA


Company Reference No : Project No : 120
Report No : 01 Sample Inward No :
Sample Series Number : 01 Report Issue Date :

Parameters Raw Sample TBFS & TBT Plasma MVR Test Methods Remarks
CMS Oxidation Outlet
Outlet Outlet
pH 8.3 8.3 8.2 4.7 IS 3025 (PART-11)
TDS (mg/L) 40743 40111.46 41355 190 IS 3025 (PART-16)
TSS (mg/L) 190 140 80 Nil IS 3025 (PART-17)
O & G (mg/L) 87.2 6 0.8 Nil IS 3025 (PART-39)
COD (mg/L) 1700 1500 600 BDL IS 3025 (PART-58)
T.H (mg/L) 1900 1900 900 - IS 3025 (PART-21)
Total Alkalinity 900 690 - - IS 3025 (PART-23)

Remarks:______________________________________________________________

_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
____________________________________________

For Saroj Tiny Tech India Pvt. Ltd.

Chemist Lab In-charge Authorized Signatory


Test Method and Observation

Treatment Technology

 Tinny Bubble Flotation System


 Ceramic Membrane System
 TBT Plasma Oxidation
 Evaporation

Process Flow Diagram

Raw Effluent

TBT

CMS

TBT Plasma Sub Surface


Oxidation Disposal

MVR

Surface
Disposal

For Saroj Tiny Tech India Pvt. Ltd.

Chemist Lab In-charge Authorized Signatory


Reference Photos

For Saroj Tiny Tech India Pvt. Ltd.

Chemist Lab In-charge Authorized Signatory