NETWORK CLOCK-REFERENCE DATA Page 1 of 9

PRINTOUT DESCRIPTION         1/190 83-CNT 212 2424 Uen D

NETWORK CLOCK-REFERENCE DATA

1   Format
1.1   Printout

1.1.1   Format 1
NETWORK CLOCK-REFERENCE DATA

CLKREF SCX PRI FDL AFDL ACL STATE FCODE


/ \
|/ \ |
||ext | |
|+gps + scx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| . . . . . . . . |
| . . . . . . . . |
| . . . . . . . . |
|/ \ |
||ext | |
|+gps + scx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
\ /
[NONE]
[EOT DURING PRINTOUT]
END

1.1.2   Format 2
NETWORK CLOCK-REFERENCE DATA

CLKREF SMX PRI FDL AFDL ACL STATE FCODE


/ \
|/ \ |
||ext | |
|+gps + smx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| . . . . . . . . |
| . . . . . . . . |
| . . . . . . . . |
|/ \ |
||ext | |
|+gps + smx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
\ /
[NONE]

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 2 of 9

[EOT DURING PRINTOUT]


END

1.1.3   Format 3
NETWORK CLOCK-REFERENCE DATA

CLKREF SCX PRI FDL AFDL ACL STATE FCODE


/ \
|/ \ |
||ext | |
|+gps + scx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| . . . . . . . . |
| . . . . . . . . |
| . . . . . . . . |
|/ \ |
||ext | |
|+gps + scx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| |
|DYNAMIC DATA |
| |
|SCX CLKMODE CLKINPUT CURFCV AVGFCV |
| / \ |
|scx clkmode [clkinput] |curfcv avgfcv| |
| \ / |
|CLKREF DFREQ ERATE RFD SSM INFO |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
| . . . . . . |
| . . . . . . |
| . . . . . . |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
| |
|SCX CLKMODE CLKINPUT CURFCV AVGFCV |
| / \ |
|scx clkmode [clkinput] |curfcv avgfcv| |
| \ / |
|CLKREF DFREQ ERATE RFD SSM INFO |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
| . . . . . . |
| . . . . . . |
| . . . . . . |
|/ \ |
||ext | |

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 3 of 9

|+gps + [dfreq] [erate] [rfd] [ssm] [info] |


||sdip| |
|\ / |
\ /
[NONE]
[EOT DURING PRINTOUT]
END

1.1.4   Format 4
NETWORK CLOCK-REFERENCE DATA

CLKREF SMX PRI FDL AFDL ACL STATE FCODE


/ \
|/ \ |
||ext | |
|+gps + smx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| . . . . . . . . |
| . . . . . . . . |
| . . . . . . . . |
|/ \ |
||ext | |
|+gps + smx pri fdl [afdl] acl state [fcode]|
||sdip| |
|\ / |
| |
|DYNAMIC DATA |
| |
|SMX CLKMODE CLKINPUT CURFCV AVGFCV |
| / \ |
|smx clkmode [clkinput] |curfcv avgfcv| |
| \ / |
|CLKREF DFREQ ERATE RFD SSM INFO |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
| . . . . . . |
| . . . . . . |
| . . . . . . |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
| |
|SMX CLKMODE CLKINPUT CURFCV AVGFCV |
| / \ |
|smx clkmode [clkinput] |curfcv avgfcv| |
| \ / |
|CLKREF DFREQ ERATE RFD SSM INFO |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 4 of 9

| . . . . . . |
| . . . . . . |
| . . . . . . |
|/ \ |
||ext | |
|+gps + [dfreq] [erate] [rfd] [ssm] [info] |
||sdip| |
|\ / |
\ /
[NONE]
[EOT DURING PRINTOUT]
END

1.2   Parameters
acl Alarm class identifier

A1
Critical alarm class

A2
Major alarm class

A3
Minor alarm class

afdl Automatic Frequency Deviation Limit (FDL). Limit for maximum permitted relative frequency
deviation. Expressed in units of 1E-4 ppm.

If the FDL value is AUTO, it indicates that automatic FDL is enabled and the automatically
calculated FDL value is printed in the AFDL column. See the Application Information for block
NCADM .

avgfcv Average frequency control value. This is the frequency control value for the timing unit
oscillator calculated over a period of approximately one hour.

Value range: 0-65535 (low < 7000, normal 18000 – 46000, high > 57000).

clkinput Timing unit clock input

The Timing unit clock input is the synchronization source currently set as input to the timing
unit oscillator.
Note: If the timing unit clock input indicates a clock-reference of type EXT or GPS on one
timing unit, then the other timing unit will be indicating the Reference Transfer Link (RTL) as
timing unit clock input.

clkmode Timing unit clock mode

FAILURE
Timing unit hardware failure.

FREERUN
Free running

IDLE
Idle

LOCKED
Locked. The timing unit oscillator is locked to the synchronization source indicated by
clkinput.

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 5 of 9

LOTR
Loss of tracking

HOLDOVR
Holdover

SYNC1
Synchronizing stage 1

SYNC2
Synchronizing stage 2

SYNC3
Synchronizing stage 3

UNAVAIL
Unavailable. The timing unit is unavailable.

WARMUP
Warm-up

curfcv Current frequency control value for the oscillator on timing unit.

Value range: 0-65535 (low < 7000, normal = 18000 - 46000, high> 57000).

dfreq Detected frequency:

1
1 Hz

1544
1544 kbit/s

2048
2048 kHz

4096
4096 kHz

10000
10000 kHz

155520
155520 kbit/s

erate Error rate

For clock-references of type EXT and GPS, this value indicates the percentage of failed
measurements during a period of approximately one minute. For clock-references of type
SDIP, this value indicates the percentage of lost, invalid or corrupted packets during a period
of approximately one minute.

ext External clock-reference

Expressed as EXT-n where:

n
Clock-reference number

fcode Fault Code

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 6 of 9

The clock-reference is externally blocked. This fault code is only valid for clock-
references of type SDIP. It indicates that the SDIP used as clock-reference is in a
blocked state.

2
The timing unit is unavailable.

3
An error in the communication with timing unit occurred

4
The clock-reference signal is lost.

5
The clock-reference signal has exceeded the permitted error rate.

6
The clock-reference signal has exceeded the limit for frequency deviation (FDL).

7
Timing unit locking error. Signal is present but the timing unit is unable to lock to this
clock-reference.

fdl Frequency Deviation Limit (FDL)

Limit for maximum permitted relative frequency deviation. Expressed in units of 1E-4 parts per
million (ppm).

If FDL value is AUTO, it indicates that automatic FDL is enabled and the automatic FDL value
is printed in the AFDL column. See the Application Information for block NCADM.

gps Global Positioning System (GPS) clock-reference

Expressed as GPS-n where:

n
Clock-reference number

info Optional additional information


pri Priority

The lowest number has the highest priority.

rfd Relative frequency deviation. Expressed in units of 1E-4 ppm.

The relative frequency deviation is measured for a period of 1000 seconds.

scx System Control Switch (SCX). Expressed as A, B or A&B.

SCX-A is located in the left side of the APZ magazine.


SCX-B is located in the right side of the APZ magazine.

smx System control and Main Switch (SMX). Expressed as A, B or A&B.

SMX-A is located in the left side of the APZ magazine.


SMX-B is located in the right side of the APZ magazine.

sdip Synchronous Digital Path (SDIP) clock-reference

See the Application Information for block SDIPST.

ssm Synchronization Status Message (SSM)

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 7 of 9

Only valid for clock-references of type SDIP. Expressed in 4-bit binary format. Value range:
0000–1111.

state Blocking state of the clock-reference

ABL
Automatically blocked. This state indicates that the clock-reference is automatically
blocked due to a fault.

EX
Executive. This state is only used for the executive clock-reference.

EX/S
Executive but fault suspected. This state is only used for executive clock-references of
type SDIP. It indicates that the clock-reference is fault free on one timing unit but that a
fault is detected by the other timing unit.

MBL
Manually blocked

SB
Standby. This state is only used for clock-references of type SDIP. It indicates that the
clock-reference is deblocked but in standby because another clock-reference, situated
on the same Switching Network Terminal (SNT), is already deblocked and working.

UPD
Updating. This state is used for 1-2 minutes after deblocking when the clock-reference
is verified to be fault free before it is taken into service.

WO
Working

WO/S
Working but fault suspected. This state is only used for clock-references of type SDIP. It
indicates that a clock-reference of type SDIP is fault free on one timing unit but that a
fault is detected by the other timing unit.

EOT DURING PRINTOUT


The operator has cancelled the printout.

NONE
No data existed to be printed.

2   Function
2.1   Format 1
This printout is received as an answer printout to command NCDAP when the timing unit is SCX. It lists the
static connection data and blocking states for all connected clock-references.

2.2   Format 2
This printout is received as an answer printout to command NCDAP when the timing unit is SMX. It lists the
static connection data and blocking states for all connected clock-references.

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 8 of 9

2.3   Format 3
This printout is received as an answer printout to command NCDAP when the timing unit is SCX and when
the optional parameter DETAIL is specified. It lists the static connection data, the blocking states and the
dynamic supervision data for SCX and all connected clock-references.

2.4   Format 4
This printout is received as an answer printout to command NCDAP when the timing unit is SMX and when
the optional parameter DETAIL is specified. It lists the static connection data, the blocking states and the
dynamic supervision data for SMX and all connected clock-references.

3   Action
This printout requires no action.

4   Printout Type
Answer printout

5   Printout Block
NCADM

6   Glossary
APZ AXE Data Processing System
FDL Frequency Deviation Limit
GPS Global Positioning System
Hz Hertz
kbit/s Kilo bits per second
kHz Kilo Hertz
ppm parts per million, 1E-6
RTL Reference Transfer Link
SCX System Control Switch
SDIP Synchronous Digital Path
SMX System control and Main Switch
SNT Switching Network Terminal
SSM Synchronization Status Message

7   References
7.1   Command Descriptions
NCDAP Network Clock-Reference Data, Print

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021
NETWORK CLOCK-REFERENCE DATA Page 9 of 9

7.2   Application Information


NCADM
SDIPST

Legal | © Ericsson AB 2013, 2015-2016

http://localhost:9032/alexserv?ID=26681&DT=om&TI=NETWORK+CLOCK-REFE... 06/05/2021

You might also like