You are on page 1of 15
FINISHED PLAN HELGA SELMER F-10 TEST RECORD OF INSULATION RESISTANCE This.technical document is the property of Kawasaki Shipbuilding Corporation and may not be copied, nor disclosed to any third party without the prior written consent of Kawasaki Shipbuilding Corporation. WG No, 6TEGGO4 MANAGER a SCALE —— | JOBNe, —— ‘CHIEF i ea fi emate KAWASAKI CHECKED SHIPBUILDING CORPORATION SAKAIDE JAPAN DRANK Sa Aibete SHIP DESIGN DEPARTMENT DATE JON. 3, 2004 (amniss2) 15 SHEETS INCL COVER me 21N1552 ==} 50,000-DWT MOTOR BULK CARRIER _ | eR #0 za RESULT OF ONBOARD TEST BR ee FOR INSULATION RESISTANCE BR a (ELECTRIC PART) ee w” w” a HELGA SELMER a) ae cee sty x _ [SCALE JJOBNO. 21N1552 3 AL Lattipsabed 2 o et KAWASAKI SHIPBUILDING a a CHECKED fathuro _ CORPORATION & - di INSPECTION SECTION craw , QUALITY ASSURANCE DATE 2004. 5.11 DEPARTMENT KAWASAKI SHIPBUILDING CORPORATION (14) SHEETS INCL. COVER TEST PROCEDURE OF INSULATION RESISTANCE 1. In General 1.1 The measurement of insulation resistance is to be carried out in the presence of the surveyor and Owner's inspector. 1.2 Measuring equipment Rated voltage Equipment. S50V to 3, 300¥ D.C. 1,000V megger below — 500V D.C. 5007 megger 1.3 Semi-conductors and other electronic components are to be disconnected or short-circuited before applying test voltage in order to avoid the electrical damage. 1.4 If the measured resistance of grouped circuit is below allowable value, the circuit is to be separated and the resistance of each individual circuit is to be measured. It is to be confirmed that the resistance of each individual circuit is in allowable value. Otherwise the correction is to be made on the particular circuit to remove the cause of the low insulation resistance. 2 Rule and Regulation : NV 3. The method of Measurement, 3.1 Power circuit 3.1.1. Generator circuit The resistance is to be measured between conductor and earth with ACB in the OFF position. 3.1.2. Bus bar of main switchboard The resistance is to be measured between bus and earth with all ACB and disconnecting switches in the OFF position, 3.1.3. Feeder circuit . The resistance is to be measured between each conductor and earth, between conductors, with both of feeder breaker on switchboard and branch breaker on dist. board in OFF position, Primary and secondary circuit of transformer is to be measured between conductor and earth only. 3.1.4, Sub-cireuit of motor and other equipment (1) The resistance of the following circuits are to be measured between conductor and earth with the disconnecting device in OFF position in starter, switch box and distribution board. (a) Motor circuits (b) Circuits for electric heater and small motor equipment when there is no disconnecting device on the equipment. (2) The resistance of the following circuits are to be measured betiveen each conductor and earth and the minimum value of each insulation resistance is to be recorded. (a) Circuits between distribution board or G.S.P. and starter. (b) Receptacle circuit ; The resistance is to be measured in the condition of the portable equipment is disconnected by plugging-out. (c) Cireuits for electric heaters and small motor equipment when disconnecting device is on the equipment. 3.2, Lighting circuits Measuring method of main lighting circuits are to be same as in item 3.1.3. . ‘The resistance of the lighting sub-circuits are to be measured between conductor and earth under the condition of all switch in the circuit being switched on. 4, Remarks Insulation resistance of a circuit is to be IMM or more as a rule. & BF kh & Sade RESULT OF INSPECTION ee SLE Job No. APF: SCC Shipping Company aaa 21N1552 Owner (Warshall Islands) Limited |Name HELGA SELMER ze ars RSH aa Electric cable & apparatus No.of Piooe” a On board REF : ‘i le = 8 - Tnwpect ton Unsulation resistance tes oe April 29th 2004 Condition Woather Fine Humidity 53% Atmos. temp — 23 °C Lighting sys. 100V | Conmunicat. sys. 100 V | Power system 440 V Note : Method of insulation resistance test 1) Cable and apparatus for power and lighting circuit Measure insulation resistance between all insulated poles and earth and poles. : 2) Intercommunication circuit and final subcircuit of lighting Measure insulation resistance the cables and apparatus in connection ‘The circuit to be disconnected and remeasure the insulation resistance test result shows less than specified value (1.0 2 MQ) 3) Instrument : Measured by DC 500 V MEGGER Maker : YOKOGAWA “Registered No. EM220024 Effect. Period : 2004. 12 Unit : MQ Cire. No. Description Co | are Wo. Feeder panel) Pi01_ | Group starter for F.0.6 L.0. purifier = 100 P102__| Group starter for Floor starboard = 100 P103_ | No.1 Engine RM power dist, board = 100 Pi04 | Group starter for Prov. ref. compressor = 100 P105 | Boiler control panel = 100 P106 | Group starter for Accommodation fan = 100 PI07 | Group starter for FWD deck nachinory =. 100 P108_ | Group starter for APT deck machinery = 100 Pi09 | Group starter for FWD deck machinery ea 100 Pil0_ [No.1 General service transforner 7aevA[ 100 PIil_| Ballast & spare cooling sea water pump 35 100 Pil2 | Emergency switch board a 100 Pil4 | No.1 Deck crane 100 PLIS [No.3 Deck crane a 100 P120__| Water mist fire pump unit 15 100 KAWASAKI SHIPBUILDING CORPORATION INSPECTION SECTION QUALITY ASSURANCE DEPARTMENT KOBE SHIPYARD Unit : MQ Insulation Cire. No. Description ee yerane (Wo. 2 Feeder panel) P201_| Group starter for F.0.& L.0. purifier = 100 202 | Group starter for Floor port = 100 204 | Group starter for 2nd deck = 100 205 | Galley power dist. board = 100 P206 | W/E manoeuver & protection system = 100 P207 | Group starter for FWD deck machinery = 100 208 | Group starter for APT deck machinery 7 100 209 | Group starter for Air condition plant = 100 P210__| Group starter for Work shop = 100 P2ii_| Ballast pump 55. 100 P2i2 | No.2 Steering gear i 100 P213 | No.2 Deck crane = 100) pala | No.4 Deck crane = 100 P2i5 | No.2 General service transformer 75KVA| 100 (Wain switch board) DGL No.1 Main diesel generator 480 100 DGI-EX | Exciter for above = 100 DGI-H_ | Space heater for above 0.4 100 Dez, No.2 Main diesel generator 480 100 DG2-EX | Exciter for above = 100 DG2-H_ | Space heater for above 0.4 100 DGB) No.3 Main diesel generator 480 100 DG3-EX | Exciter for above = 100 DG3-H__| Space heater for above 0.4 100) (No.1 Vital group starter panel) 1PGSI-i'| No. 1 F. 0. booster pump 16 100 1PGS2-U| No.1 F. 0. circulating pump aa 100 1P6S3-U| No. 1 Stern tube L. 0. pump 0.75 100) 1PGS5-M | No. 1 Wain L. 0. pump 55 100 1P636-M | No.1 G/E priming L. 0. pump 0.9 100 1P6S7-M | No.3 G/E priming L. 0. pump 0.9 100 1PGS8-M | No.1 Main cooling fresh water pump 1 100 1PGS9-M| Aux. cooling sea water pump 16 100 1PGS10-M| No:1 Fire & general service pump 30 100 1Pesit-u| No. 1 Feed pump 5.5 100 1p6s12-4| No. 1 W/E aux, blower 35.5) 100 1PGsit-| Purifier station exhaust fan 0.2 100 1P6S15-K| No.1 Main air compressor 30 100 Unit _: MO Cire. No, Description ra | Jnsulation (No.2 Vital group starter panel) 2PGS1-M | No. 2 F.0, booster pump 15 100 2GS2-M | No.2 F.0. circulating pump 3.7 100 2PCS3-M | No.2 Stern tube L. 0, pump 0.16 100 2PcS5-I€ | No.2 Main L. 0. pump 88 100 2PGS6-M | No.2 6/E priming L. 0. pump 0.9 100 2pcs7-W | Boiler F. 0. booster pump 04 100 2GS8-M | No.2 Wain cooling fresh water pump ul 100 2ecs9-it | Wain cooling sea water pump 37 100 2PCS10-M| No.2 Fire & general service pump 30 100 2PGSLI-M| No.2 Feed pump 5.5 100 aPGS12-U | No. 2 W/E aux, blower 35.6 100 2POS13-M| No.2 Wain air compressor 30 100 2PCSi-U | No.2 Engine room vent. fan 1 100 (FWD deck machine group starter panel) PLO7-M | No.1 B/H pump for deck machinery 45 100 PLO7-H | Space heater for above 0.08 100 207-M | No.2 E/H pump for deck machinery 45 100 P207-H | Space heater for above 0.08 100 1P109-K | No. 1 E/H pump for hatch cover 37 100 1P109-H | Space heater for above 0.07 100 2pi09-X( | No.2 E/H pump for hatch cover 37 100 2P109-H! | Space heater for above 0.07 100 '3P109 | FWD space service transformer rskva| 100 4P109 | Electric arc welder = 100 (0.8 L-0 purifier group starter panel) iPt0i-W | No. 1 F. 0, purifier 5.5 100 1Pl01-P1| Control trans. for F.0.purifier control panel| — 100 1p201- | No. 2 F. 0. purifier 5.5, 100 api0i-i | F.0. transfer pump uw 100 2p201-M | D.0. transfer pump 2.2 100 spi01-M | L.0. purifier 5.5 100 3p201-M | Aux, L..0, purifier LS 100 4P101-U | L. 0. purifier feed pump 0.75) 100 4P201-U | Aux.L. 0. purifier feed pump 0.75 100 (Work shop group starter panel) 1P210-M | Universal machine tool Pa) 100 2p210-M | Grinder 0.75 100 3P210 | WE over head crane 19/04) 100 4P210_| WE exhaust valve grinder machine e.a/0.1| 100 Unit : MQ Cire. No. Description sa | Insulation @nd deck group starter panel) 1P204- |'No. I Fresh water’ hyd. pump 37 100 2p204-M | No.2 Fresh water hyd. pump BT 100 apzod-it | Drinking water hyd. pump 3.7 100 a204-M | Hot water circulating pump o4 100 (AFT dock machinery group starter panel) P108-a | No.3 E/H pump for deck machinery 30 100 Pl08-H | Space heater for above 0.08 100 P208-M | No.4 E/H pump for deck machinery 30 100 P208-H | Space heater for above 0.08 100 (Prov. ref. compressor group starter panel) 1P104-M | No.1 Provision ref. unit, 3.7 100 2P104-M | No.2 Provision ref. unit 37 100 (Prov. ref. control panel) iLi-ii | Diffuser fan (meat RD 0.05 100 111-12 | Defrost, drain pipe & pan heater (neat RIO = 100 ati | Diffuser fan (fish RD 0.05 100 2Li1-H2 | Defrost, drain pipe & pan heater (Fish Ri ee 100 3L11-M | Diffuser fan(vegitable Ru) 0.05 100 Lil-_| Door heater (fish & meat RM) i 100 (Accommodation fan group starter panel) 1P106-M | No.1 Exhaust fan(sanitary space) 04 100 2P106-M | No. 2 Exhaust fan (galley) 0.75 100 3P106-M | No, 3 Exhaust fan(sanitary space) 0.2 100 5P106- | No.4 Exhaust fan (dry prov. store) 0.2 100 6P106_| Accommodation ladder winch ($)&(P) is/is| 100 7106 | Life, Life & rescue boat davit winch 18/3.7| 100 8P106_| Wachinery parts davit rs/i.5| 100 97106 | Heater (drying room) 2.0 100 10P106 | Galley air conditioner 3.7/0.8 100 Goiler control panel) Pi0s-Wi | Forced draft fan & F. 0. pump 2.2 100 Pu0s-W4 | F.0. heater 4.0 100 (No. 1 Deck crane control panel) Wain hydraulic oi] pump 125 100 Oil cooler fan 5.5 100 Servo pump 16 100 100 Volt. control circuit = 100 Unit : MQ Cire. No, Description ta | Tnsulation (Wo. 2 Deck crane control panel) Main hydraulic oi] pump 125 100 Oil cooler fan 5.5 100 Servo pump 15 100 100 Volt. control circuit = 100 (Wo. 3 Deck crane control panel) Main hydraulic of pump 125 100 Oil cooler fan 5.5 100 Servo pump 1.6 100 100 Volt. control cireuit = 100 Wo. 4 Deck crane control panel) Main hydraulic oil pump 125 100 Oil cooler fan 5.5 100 Servo pump Ls 100 100 Volt. control cireuit oa 100 (ir conditioning plant control panel) ‘Air condition. ref. compressor 22 100 ‘Air condition. fan UL 100 (Wo. 1 Engine RM power dist. board) 1P103_| Waste oil incinerator control panel = 100 2P103 | Bngine control room air conditioner 3770.8] 100 3P103_| No.6 Exhaust fan (steering gear room) 0.2 100 (Waste oil incinerator control panel) Forced draft fan 1.5 100 Waste of] pump O4 100 Cooling fan 75 100 (Floor port group starter panel) 1P202-M | Bilge pump 16 100 ap202-M | Sludge pump 15 100 3P202-M | WE turning gear 2.2 100 4P202- | Sewage treatment unit x75] 100 (Bloor starboard group starter panel) iPi02- | Air cooler chemical cleaning pump 2.2 100 sPlo2- | 1.0. transfer pump 2.2 100 aP102-M | Fresh water generating plant control panel |rs/o7s| 100 Unit : MQ Cire, No. Description nar | pasulation (AC 440 volt. galley power dist. board) 1P205_| Blectric disposer 2 100 2P205 | Electric cooking range 23 100 3P205_| Electric soup boiler 5.0 100 (AC 100 volt. engine RM section board) Li__| 1-1 Lighting dist. board = 100 12 [1-2 Lighting dist. board = 100 13 _| 1-3 Lighting dist. board = 100 14__| L-4 Lighting dist. board = 100 15 | L-5 Lighting dist, board = 100 16 [1-6 & IL-6 Lighting dist. board = 100 Lt | Galley power dist. board = 100 L9__| Ship's laundry power dist. board om 100 L10_| Crew's mess power dist. board = 100 Lil_| Prov.ref. control panel = 100 Ta1_| 1-21 Lighting dist. board = 100 122_| 1-22 Lighting dist. board = 100 123__| Wain switch board(space heater) = 100 NL__| Navigation light indicator = 100 (AC 100 volt. galley power dist. board) IL7 | Electric rice cooker (1) 1.0 100 2L7_| Electric rice cooker(2) 14 100 3LT_| Electric moat chopper & moat slicer caer] 100 4L7_| Electric refrigerator(1) & toaster fozsro.ee] 100 @L7_| Electric water boiler 2.0 100 71 | Blectric refrigerator(2) & toaster fezzro.ee] 100 8L7_[ Hot ‘plate (pantry) 10 100. 9L7__[ Receptacle for hot plate = 100 10L7_| Receptacle for hot plate om 100 LIL? | Receptacle for hot plate = 100 (AC 100 volt. crew’ s mess power dist. board) 1L10_| Electric water boiler 2.0 100 2L10_| Electric refrigerator & toaster azaaee] 100 3L10__| Hot plate 1.0 100 4110 | Receptacle for hot plate = 100 5L10_| Receptacle for hot plate = 100 €L10_| Receptacle for hot plate = 100 7L10_| Receptacle for general use = 100 (AC 100 volt. ship’ s laundry power dist. board) 1L9 | Blectric washing machine = 100 Unit: MQ Ciro. No. Description rer | Pasulation 219 __| Blectric washing machine = 100 319__| Blectric washing machine = 100 4L9 | Receptacle for iron = 100 (Guergency switch board) EG | Buergency diesel generator 80 100 EGY | Exciter for above = 100 BG-H_| Space heater For above o.oorf 100 EPI__| No.1 Steering gear u 100 EP2 | Bnergency fire pump 30 100 EP4__| No.1 Emergency service transformer sexval 100 EP4A | No.2 Bergency service transformer sexval 100 EPS | Battery switch board = 100 EP6 | No.1 Engine room fan (reversible) uw 100 EP7__| No.1 Wain air compressor = 100 EP8__| Electric arc welder (eng. work shop) ia 100, (AC 100 Volt. emergency Feeder panel) ENL | Navigation light indicator = 100 BLi__| Bl-I Bnergoncy light dist. board i 100 BL3__| BL-3 Bmergoncy light dist. board i 100 EL4 | El-4 Emergency light dist. board = 100. EL5_| Radio rack console at uly FL6 | Tnstrunont & alarm system dist. board = 100 BL?__| Interior communication dist. board = 100 EL8 | Battery charger for B/G engine starter = 100 BLO | E/R monitoring & alarm system = 100 GA-A_| General alarm system = 100 FA-A_| Fire alarm detecting system = 100 Gattery switch board) BLIA | Battery light (emergency generator room) = 100 BLIB_| Battery light (near life boat) = 100 avigation Light indicator) NLIA_| Fore mast head light = 100 NL2A_| Fore mast head light = 100 NLIB_ | After mast head Light = 100 NL2B_| After mast head light = 100 NLIC_| Starboard side light = 100 NL2C_| Starboard side light = 100 NLID_| Port side light = 100 NL2D_| Port side light = 100 NLIE_| Stern light = 100 Unit : MQ Cire. No. Description kW Insulation Resistance NL2E_[ Stern light = 100 NLIF_| Anchor light = 100 NLIG | Not-Under-Connand Light = 100 (Signal light control panel) Hip-siii| Steering head Light = 100 #LiD-S4i | Suez canal signal light = 100 #LiD-S51 | Suez canal signal Light = 100 ELID-S61 | Suez canal signal Light = 100 HLip-sisi| Suez canal stern red light = 100 (El Flood light dist-bord) LIA | 500 watt Flood light Wav. bridge deck) = 100 LIB | 700 watt Mercury lamp (Nav. bridge deck) = 100 Lic [700 watt Mercury lamp (Nav. bridge deck) = 100 LID | 400 watt Mercury lanp(B deck aft. center) = 100 LIE | 500 watt Flood light (B deck after) = 100 LiF | 500 watt Flood light (Nav. bridge deck) = 100 Lil = 100 Liy = 100 Lik = 100 (G2 C deck lighting dist. board) L2A = 100 128 | Wheel house room heater (S) 10 100 12C_| Wheel house room heater (P) 1.0 100 12D = 100 L2E = 100 LaF = 100 126 = 100 Lait = 100 12] = 100 12K = 100 L2L_| Electric washing machine (officer’ s laundry) [ — 100 L2M | Electric washing nachine(officer’ s laundry) | — 100 L2N | Electric dryer (officer's laundry) i 100 L2P_| Electric dryer (officer's laundry) = 100 12a | Receptacle for iron(officer’ s laundry) = 100 12k | Receptacle for general use(officer’s laundry | — 100 (3 B deck Lighting dist, board) L3A = 100 138 = 100 13C = 100 10 Unit_: Ma circ. No. Description i Lad = 100 L3E. = 100 LaF = 100 eG = 100 L3H | Sterilizer (hospital) = 100 13]__| Battery charger for life boat = 100 (4A deck Lighting dist. board) LAA = 100 Lab = 100 Lac = 100 Lad = 100 LAE = 100 LaF = 100 LAG = 100) LaH_| Space heater for life boat davit = 100 (C5 Upper deck Lighting dist. board) 15h = 100 15 = 100 150 = 100 LoD = 100 Loe = 100 Lor = 100 L5G = 100 L5H__| Receptacle (#5 cargo hold) a 100 LB] = 100 (-6_No.4 Grane house Lighting dist. board) L6A__| Receptacle (#3 & #4 cargo hold) = 100 L6B__| Receptacle (#4 & #5 cargo hold) = 100 L6C = 100 i) = 100 (iL-6_No.2 Grane house Lighting dist. board 1L6A_| Receptacle (#1 & #2 cargo hold) = 100 1L6B_| Receptacle (#2 & #3 cargo hold) = 100 IL6C = 100 ied = 100 (G21 No.1 Engine room lighting dist. board) 121A = 100 L21B = 100 L2ic = 100 ut Unit: MQ Cire. No, Description ter | Fasuation 12D = 100 L21E = 100 L2iF_| Space heater (steer. gear, emerg. fire pump) = 100 L216 = 100 ([-22 No.2 Engine room lighting dist. board) L228 = 100 L228 = 100 1220 = 100 L220 = 100 L228 = 100 L22F = 100 1226 = 100 L22H_| Receptacle = 100 L223 _| Receptacle = 100 L22K_| Receptacle = 100 (E41 Upper deck fore Lighting dist, board) Lala = 100 LAB = 100. LAIC = 100 LAID = 100 LAIE = 100 Lair = 100 Laig | Suez canal search Light 3.0 100 (BL-1 Emergency light dist. board) ELIA = 100 ELIC | Window wiper = 100 ELID = 100 ELIE = 100 ELIF = 100 ELIG = 100 ELIA = 100 (EL-8 Emergency light dist. board) ELBA = 100 ELSB = 100 EL3G = 100 EL3D = 100 ELSE = 100 ELSE = 100 EL3G = 100 12 Unit : WO Cire. No. Description rar | jasulation (EL-4 Emergency light dist. board) FLAA = 100 ELAB = 100 ELAC = 100 BLD = 100 (.C.& Navigation system dist, board) ‘F-A_[ Auto. exchanger telephone = 100 DA-A_ | Loud speaker talk-back & PA system = 100 RA__| Rudder angle indicator = 100 Du | Dimmer circuit = 100 GS [C02 Fire extinguishing system i 100 Le-A_| Gyro compass = 100 Lp-A_| Steering gear hyd. lock alarm = 100 ¥i_| Electro magnetic log = 100 ES | Echo sounder = 100 HE | Anono meter = 100 CE-A_| Electric clock = 100 W | Whistle control = 100 RERI-A | No. 1 Radar = 100 RERI-A | No. 2 Radar = 100 RB__| Broadcast receiving antenna systen = 100 RSI-A | Satellite communication system(standard-B) | — 100 RA Weather facsimile = 100 VOR-AI | Voyage data recorder = 100 WoR-A2 | Voyage data recorder = 100 HA-A | Water ingress alarm system = 100 DEW | Dewater system of FWD space = 100 Cnstrunent & alarm system dist. board) DLG-7604| Hot water heater temperature control = 100 BSC__| Bilge separator = 100 ve2-4 | W/E F.0.disch. filter control system = 100 MB-A_ | Engine telegraph system = 100 DLG-410A| Excess steam dump valve control = 100 AL__| Engincer call system = 100 E-A__| Engine room call system = 100 NA | Propeller shaft revolution indicator = 100 Receptacle for general use = 100 LFA-Al | Water mist extinguishing system = 100 wy

You might also like