Professional Documents
Culture Documents
LED Lighting
Headquarters:
5F, No.113, Zhongcheng Rd, Tucheng Dist,
New Taipei City 236, Taiwan
Tel: 886-2-2268-9570 Fax: 886-2-2268-9571
2017 September
Company History ● ISO9001 ● 100W and 40W Explosion- ● Capital increased to USD 3.44 million ● 8 products certified by ATEX, GB and IECEx
● Established ISO14001 proof certified
● Passed ATEX factory inspection ● 2 Products passed UL60079 recognition
Certified ● Explosion-proof patent ● Relocated and expanded production ● Add optical testing machine to enhance QC
granted
● Applying for global trademark and patent ● 5 products were granted
缺圖 CR Explosion-proof
certificates
2002
➤➤➤➤ ➤ ➤2011
➤ ➤ ➤ 2011
➤ ➤ 2011
➤ ➤ ➤ 2012
➤ ➤ 2013 2013
➤➤➤➤➤➤ ➤➤➤2014
➤➤➤2015
➤➤➤2016
➤ ➤ 2017
➤➤➤➤➤
● Office relocated ● Changed company type ● 3 products received TS ● 7 items received TS certificate (Taiwan) ● Automatic Production
and raised capital certificate (Taiwan) ● 1 item certified by KOSHA ● Automatic inspection
● 3 products received ATEX, ● 3 items certified by ABS ● Set up office in Houston
GB, IECEx certificates ● UL844 certification received ● Explosion-proof LED Lightings
● QAN/QAR certificates were sold to North America.
A1 A2
www.tht-ex.com www.tht-ex.com
Safety Is Your Top Priority
Services and Advantages
-150
-/+180
150
Customized mounting bracket as per request.
Optical report, IES file -120 120
293.9
5723.94110603737lm
166.0
0 0
158.9
-90 90
-60 60
1.0m
1210.75 / 2071.77 lx 3.18 m Ø234.0
-30 30 UNIT: cd
0
2070
C0/180
LM80 report with driver circuit available.
C90/270
4.0m 1242
(underwater 1 meter ~ 1000 meters) available.
75.67 / 129.49 lx 12.7 m
(cd)
828
72 ~ 1000 hours salt water spray
5.0m
Height
48.43 / 82.87 lx
Eavg / Emax
15.9 m
414
testing passed products available.
Beam angle: 115.64˚ at 50%
0.0
All accessories and screws are
made by stainless steel.
-180 -135 -90 -45 0 45 90 135 180 Angle ( ° )
A3 A4
www.tht-ex.com www.tht-ex.com
Safety Is Your Top Priority
Quality Management
THT-EX has countless experience in R&D, Design and Manufacturing of reliable
products intended for use in Harsh and Hazardous applications. As well our
reliable and hardworking Engineering team includes Certified and Professional
engineers specialized in explosion-proof products that makes the development
very proficient. Now various autonomous management systems that are critical
to the company’s operation are implemented such as but not limited to Quality
Management System, ERP, Drawings and Document Management, Instrument
and Equipment verification system, Control, SOP and SIP. Through all of the ▲ Light Intensity Distribution ▲ Frozen Tester ▲ Salt Water Spray Tester
mentioned undertakings and maintaining such strict compliance will continuously
keep us committed and determined to our intent of providing safe and reliable
explosion-proof products to all of our valued customers and business partners.
Test Equipment
▲ Lux Meter
▲ Thermal Imagers ▲ Hydraulic ▲ Direct Pressure
▼ Environmental Simulator Pressure Tester Leak Tester
(-40°C∼+150°C) ▲ Impact Test Machine
▲ Laser Marker
▲ 2.5D Tool
Microscope
▲ Burn in Test ▲ Integrating Sphere ▲ Waterproof Function Test ▲ Automatic Assembly Machine ▲ 3D Printer
A5 A6
www.tht-ex.com www.tht-ex.com
Safety Is Your Top Priority
TM-21 Projection for THT-ACLED-20W-220V with Driver Inside the Test Chamber Life time
Same as LED chips Limited by Capacitor
(> 60,000hrs) (5,000∼10,000hrs)
1.2
Both AC/DC
2 year 17,520hrs
Power Input AC power only
are applicable
95% at 55˚C
92% at 85˚C
1 88% at 105˚C
1 year 8,760hrs
Volume Small Large
97% at 55˚C
0.8 96% at 85˚C
% Luminous Flux at 55˚C Total Power
% Luminous Flux
L70: 80,000hrs
A7 A8
www.tht-ex.com www.tht-ex.com
Safety Is Your Top Priority
Benefits of Explosion-proof
TS Taiwan ATEX E.U.
LED Lighting
● Small volume and light weight.
● Longer lifetime, over 50,000 GB China UL N.A.
hours.
● IP67 68, Salt water spray
testing 72~1,000 hours passed. KOSHA Korea NOM Mexico
● No driver and so without trans-
form loss.
THT-EX 60W
● AC in design with simple wiring, ABS Explosion-proof certificate for marine
HPS 100W fewer components and lower
malfunction rate.
CR Explosion-proof certificate for CR Classification Society
Replacement wattage
HPS wattage of THT-EX lighting Reference condition
A9 A10
www.tht-ex.com www.tht-ex.com
Safety Is Your Top Priority
Explosion-proof Certifications
IECEx (International Electrotechnical Commission) ABS (Exp. certificate for marine) KOSHA (Korea)
•Certified product item:392• •Certified product item:68• •Certified product item:18•
A11 A12
www.tht-ex.com www.tht-ex.com
OUR TEAM THT-EX
Product Index
● C.W.: 5000K ± 10% ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10% ● W.W.: 3000K ± 10%
Certifications Certifications
Model Product picture Voltage Watt. Color IP Rating Page Model Product picture Voltage Watt. Color IP Rating Page
24 40
110 24 50 W.W.
W.W.
L1203 120
20 ● ● ● ● ● ● IP67/68 1 L1219C 110 60 ● ● ● IP67/68 43
220 C.W. 220 70 C.W.
277 80
480
24 24 10 W.W.
110
W.W. L1239 110 ● IP67/68 49
P1202 120
40 ● ● ● ● ● ● IP67/68 5 220 20 C.W.
220 C.W.
277 Red
480 24
Yellow
L1219D 110 10 Blue ● ● ● ● IP67/68 52
24 40 W.W. 220
● ● ● ● ● 9 Green
L1105 110
60 C.W.
IP67/68
220
L1219A 220 10 Red ● ● ● ● IP67/68 57
120 24 W.W.
L1105S 36 ● IP67/68 13
220 50 C.W. 10
L1219A 220 Green ● ● ● ● IP67/68 62
20
110
120 40 W.W. L1320
L1319 ● ● ● ● IP67/68 17 110 10
220 60 C.W. Emergency C.W. ● IP67/68 67
277 Lighting 220 20
24 30 W.W. 110 10
L1303C 110 60 ● IP67/68 21 L1601 220 20
W.W.
● IP67/68 69
220 90 C.W. Light Tube C.W.
277 40
24 60
110 65 110 13 W.W.
W.W. L1605A 14 ● IP67/68 73
∼
L1102 120
220
75
80 ● ● ● ● ● ● ● IP67/68 25 220 16 C.W.
C.W.
277 95
480 100
110 23 W.W.
L1605B ● IP67/68 76
120 50 W.W. 220 27 C.W.
L1102S ● IP67/68 29
220 95 C.W.
110 4
24 E1215 C.W. ● IP67/68 79
220 8
110 110 W.W.
L1217 120
220 120 ● ● ● ● ● ● IP67/68 33 EXP. Cable
C.W.
277 140 Gland N/ A N/A N/ A ● IP67/68 81
480
(Long Type)
50
110 60 W.W.
37 EXP. ● ●
L1219B 70
● ● ● ● IP67/68 Junction ● IP67/68 83
220 C.W. A A
type type
80 Box A type B type
I THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. II
L1203 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
20W
Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram
Certifications:
-120 120
• Zone 21 • Zone 22 • IP 67 / 68
• Class I, Division 2, -60 60
Groups A, B, C, D
187.8 • Class II, Division 2, -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
UNIT: cd
Groups F and G 0 ANGLE (DEG)
Dimension in Millimeters C0/ 180
AVERAGE BEAM ANGLE (50%) : 111.20 DEG
C90 /270
Electrical Ratings
Voltage 24V/110V/120V/220V/277V/480V AC Optical Information
Applicable Area
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT • Oil Refinery Complex
5000K ± 10% (Cool White)
Wattage (Amps) 20W ( 0.04A ~ 0.83A ) • Petrochemical Complex
Operating Temperature - 20°C ~ + 40°C > 80 (Warm White)
CRI • Painting Facility
> 70 (Cool White)
Power Factor > 0.95 • Transporting Natural Gas
≧ 90 (Warm White)
Lum/Watt. • Transporting Liquefied
≧ 100 (Cool White)
Raw Materials Petroleum Gas
≧ 110° (Warm White) • Offshore Platform
Housing Aluminum Alloy Beam Angle
≧ 110° (Cool White)
(Oil and Natural Gas)
Screws Stainless Steel
IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
1 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 2
THT-EX L1203
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 90°(H90) Straight Electrical Tube (P90) Oil Tank (O)
[ Pendant Mount ] Wall Mount 90° (W90) Mobility type (M)
Ø145.0
157.6
275.0
267.9
409.0
Ø264.0
192.8
187.8
16.2
107.3
26.1
209.8
93.5 182.0 93.5
179.0
20.0
Stanchion 25° (S25) Stanchion 90° (S90) Ø123.0
[ Bending Electrical Tube ] [ Bending Electrical Tube ]
Tripod (TA)
Angle adjustable
93.
5
25°
272.2
259.2
236.9
90
°
285.2 251.0
3 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 4
P1202 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications:
-120 120
Upper Entry
Applicable Location Environmental
-90 0 0 90
Ratings
178.0
• Zone 1 • Zone 2
• Zone 21 • Zone 22 • NEMA 6/6P
203.0 130.0 • Class I, Division 2 • IP 67/68 -60 60
Side Entry
Group A, B, C, D
97.5
• Zone 1, AEx d IIB + H 2 -30 30 -180 -135 -90 -45 0 45 90 135 180
0 UNIT: cd
203.0 • Zone 21, AEx tb IIIC ANGLE (DEG)
264.5 C0 / 180
AVERAGE BEAM ANGLE (50%) : 102.20 DEG
Dimension in Millimeters C90 / 270
Electrical Ratings
Optical Information
Voltage 24 V/110 V/120 V/220 V/277 V/480 V AC Applicable Area
3000K ± 10% (Warm White)
Frequency 50Hz/60Hz CCT • Oil Refinery Complex
5000K ± 10% (Cool White)
Wattage (Amps) 40W ( 0.08A ~ 1.67A ) • Petrochemical Complex
Operating Temperature - 20°C ~ + 40°C > 80 (Warm White)
CRI • Painting Facility
Power Factor > 70 (Cool White)
> 0.95 • Transporting Natural Gas
≧90 (Warm White)
Lum/Watt. • Transporting Liquefied
Raw Materials ≧100 (Cool White)
Petroleum Gas
Housing Aluminum Alloy ≧110° (Warm White) • Offshore Platform
Beam Angle
Screws Stainless Steel ≧110° (Cool White) (Oil and Natural Gas)
Tempered Glass IEC Standards impact - resistant > 4 Joule IES Files Available upon request
5 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 6
THT-EX P1202
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Stanchion 25° (S25) Straight Electrical Tube (P90) Ceiling (C90)
[ Pendant Mount ] [ Pendant Mount ] [ Bending Electrical Tube ]
18.0
25°
60.0
3.0
60.0 399.0
115.0
145.0
145.0
83.0
275.0
227.5
203.0
396.9
59.0
25°
130.0
130
83.0
.0 268.8
130.0
132.5
25°
130
.0
130.0
90
(892)
°
(998.2)
200.0
145.0
Optional accessory:
60.0
802.3 698.8
Reflector
25°
7 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 8
L1105 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications:
-120 120
-60
241.0 Applicable Location
Applicable Location Applicable Area
Environmental Ratings
60
155.5 -90 0 0 90
• Oil Refinery Complex
•• Zone
Zone 1
1 •• Zone 2
Zone 2 • NEMA 6 / 6P -180 -144 -108 -72 -36 0 36 72 108 144 180
• Petrochemical Complex -30 30
•• Zone
Zone 21
21 •• Zone 22
Zone 22 • IP 67 / 68 Facility UNIT: cd
• Painting 0 ANGLE (DEG)
Ø184.5
C0 /180
• Transporting Natural Gas -60 60
C90 /270 AVERAGE BEAM ANGLE (50%) : 109.10 DEG
Environmental Ratings • Transporting Liquefied
• NEMA 6 / 6P Petroleum Gas -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
• Offshore Platform 0 UNIT: cd
• IP 67 / 68 ANGLE (DEG)
Dimension in Millimeters (Oil and Natural Gas) C0 / 180
C90 / 270 AVERAGE BEAM ANGLE (50%) : 109.10 DEG
Electrical Ratings
Voltage 24V/110V/220V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
5000K ± 10% (Cool White)
Wattage (Amps) 40W ( 0.18A ~ 1.6A )/60W ( 0.27A ~ 2.5A )
Operating Temperature -20°C ~ +40°C > 80 (Warm White)
CRI
> 70 (Cool White)
Power Factor > 0.95
≧ 90 (Warm White)
Lum/Watt.
≧ 100 (Cool White)
Raw Materials
≧ 110° (Warm White)
Housing Aluminum Alloy Beam Angle
≧ 110° (Cool White)
Screws Stainless Steel
IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
9 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 10
THT-EX L1105
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Pendant (P90) Stanchion 25° (S25) Stanchion 90° (S90)
175.0
275.0
318.2
372.0
241.0
455.5
324.5 25°
25° 200.0
295.0
90
Wall Mount 25° (W25) Wall Mount 90° (W90)
°
Ceiling (C90) Oil Tank (O)
470.0
370.0
50.0
20.0
3-Ø11.3
Ø290.0
15.0 Ø185.0
4-Ø5.3
289.0
30.0
259.0
25° °
90
Optional accessory:
343.5
Reflector 240.9
155.5
Ø371.0
Reflector
u Please refer to Page 94 for part number
11 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 12
L1105S THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications: 1266
-120 120
949
241.0 Applicable Location
Applicable Location Applicable Area
Environmental Ratings
155.5 -90 0 0 90
• Oil Refinery Complex
•• Zone
Zone 1
1 •• Zone
Zone 2
2 • NEMA 6 / 6P 633
• Petrochemical Complex
•• Zone
Zone 21
21 •• Zone
Zone 22
22 • IP 67 / 68 Facility
• Painting
Ø184.5
316
• Transporting Natural Gas -60 60
Environmental Ratings • Transporting Liquefied
• NEMA 6 / 6P Petroleum Gas -30 30
0.0
-180 -135 -90 -45 0 45 90 135 180
• IP 67 / 68 • Offshore Platform 0 UNIT: cd
ANGLE (DEG)
Dimension in Millimeters (Oil and Natural Gas) C0 / 180
C90 / 270 AVERAGE BEAM ANGLE (50%) : 113.29 DEG
Electrical Ratings
Voltage 120V/220V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
24W ( 0.2A、0.11A )/36W ( 0.3A、0.16A )/ 5000K ± 10% (Cool White)
Wattage (Amps)
50W ( 0.42A、0.23A ) > 80 (Warm Whit
Operating Temperature - 20°C ~ + 40°C CRI
> 70 (Cool White)
Power Factor > 0.95 70 ─ 80 (Warm White)
Lum/Watt.
80 ─ 85 (Cool White)
Raw Materials
≧ 110° (Warm White)
Housing Aluminum Alloy Beam Angle
≧ 110° (Cool White)
Screws Stainless Steel IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
13 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 14
THT-EX L1105S
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Pendant (P90) Stanchion 25° (S25) Stanchion 90° (S90)
175.0
275.0
318.2
372.0
241.0
455.5
324.5 25°
25° 200.0
295.0
90
Wall Mount 25° (W25) Wall Mount 90° (W90)
°
Ceiling (C90) Oil Tank (O)
470.0
370.0
50.0
20.0
3-Ø11.3
Ø290.0
15.0 Ø185.0
4-Ø5.3
289.0
30.0
259.0
25° °
90
Optional accessory:
343.5
Reflector 240.9
155.5
Ø371.0
Reflector
u Please refer to Page 94 for part number
15 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 16
L1319 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications: 1162
-120 120
871
Applicable Location Environmental
164
-90 0 0 90
• Zone 1 • Zone 2 Ratings 581
Electrical Ratings
Voltage 110 V/120 V/220 V/277 V Optical Information
Applicable Area
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT • Oil Refinery Complex
5000K ± 10% (Cool White)
Wattage (Amps) 40W ( 0.14A ~ 0.36A )/60W ( 0.22A ~ 0.55A ) • Petrochemical Complex
Operating Temperature - 20°C ~ + 55°C > 80 (Warm White)
CRI • Painting Facility
> 70 (Cool White)
Power Factor > 0.95 • Transporting Natural Gas
≧ 90 (Warm White)
Lum/Watt. • Transporting Liquefied
≧ 100 (Cool White)
Raw Materials Petroleum Gas
≧ 110° (Warm White) • Offshore Platform
Housing Aluminum Alloy Beam Angle
≧ 110° (Cool White)
(Oil and Natural Gas)
Screws Stainless Steel
IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
17 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 18
THT-EX L1319
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Stanchion 25° (S25)
Wall Mount 90° (W90)
[ Bending Electrical Tube ]
2
83.
100.0
152.5
125.0 60.0
8.2
130.0
110.0
90.0
449.6
656
Ø3 .5
30° 0
60° .0
90°
105.0
25°
656.5
(450.0)
[ Pendant Mount ]
(164.0)
100.0 130.0
125.0 60.0
8.2
656.5 105.0
130.0
110.0
90.0
208.2
Ceiling (C90)
Ø3
30° 0
60° .0
800.5
90°
21.5.0
772.5
719.5.0
105.0
8.5
60.0
90.0
35.0
94.5
656.5
656.5
19 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 20
L1303C THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
30W/60W/90W
Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram
Certifications: 2114
-120 120
1585
Applicable
Applicable Location Environmental
Location Applicable Area
Ratings
-90 0 0 90
• Zone • Oil Refinery Complex
• Zone 1 1 • Zone
• Zone 22 • NEMA 6 / 6P 1057
• Petrochemical Complex
Ø295.0
• Zone 2121
• Zone • Zone 2222
• Zone • IP• Painting
67 / 68 Facility
• Transporting Natural Gas -60 60 528
174.7
Electrical Ratings
Voltage 24 V/110 V/220 V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
Amps 0.14 A ~ 2.5 A 5000K ± 10% (Cool White)
Wattage 30W (24V not available)/60W/90W > 80 (Warm White)
CRI
Operating Temperature - 20°C ~ + 40°C > 70 (Cool White)
Power Factor > 0.95 ≧ 90 (Warm White)
Lum/Watt.
≧ 100 (Cool White)
Raw Materials ≧ 110° (Warm White)
Beam Angle
Housing Aluminum Alloy ≧ 110° (Cool White)
Screws Stainless Steel IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
21 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 22
THT-EX L1303C
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Pendant (P90) Stanchion 25° (S25) Stanchion 90° (S90)
75.0
25° NPT3/4"
293
232.0
232.0
25°
336.7
(300.0)
379.8
(474.7)
371.0
356.7
NPT1-1/2" NPT1-1/2"
Ø2
95.
0
Ø295.0
Ø2
95. Ø295.0
0 u Please refer to Page 97 for part number
Ø295.0
25°
75.0
75.0
Ø295.0
Ø2
95.
0 404.5
23 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 24
L1102 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications: 3828
-120 120
2871
Ø234.0 Applicable Location
-90 0 0 90
• Zone 1 • Zone 2 • Zone 21, AEx tb IIIC 1914
105.0
Group A, B, C, D 957
-60 60
Group B, C, D
• Class II, Division 1 Environmental Ratings
0.0
Group E, F, G • NEMA 6/ 6P -30 30 -180 -135 -90 -45 0 45 90 135 180
UNIT: cd
Dimension in Millimeters • Zone 1, AEx d IIB + H 2 • IP 67/68 0 ANGLE (DEG)
C0 / 180
AVERAGE BEAM ANGLE (50%) : 111.64 DEG
C90 / 270
Electrical Ratings
Voltage 24 V/110 V/120 V/220 V/277 V/480 V AC Optical Information
Frequency 50Hz/60Hz Applicable Area
3000K ± 10% (Warm White)
60W/65W/75W/80W/95W/100W CCT • Oil Refinery Complex
Wattage (Amps) 5000K ± 10% (Cool White)
0.125 ~ 4.16A • Petrochemical Complex
Operating Temperature -20°C ~ +40°C > 80 (Warm White)
CRI • Painting Facility
> 70 (Cool White)
Power Factor > 0.95 • Transporting Natural Gas
≧ 90 (Warm White) • Transporting Liquefied
Lum/Watt.
Raw Materials ≧ 100 (Cool White)
Petroleum Gas
Housing Aluminum Alloy ≧ 110° (Warm White) • Offshore Platform
Beam Angle
Screws Stainless Steel ≧ 110° (Cool White) (Oil and Natural Gas)
Tempered Glass IEC Standards impact - resistant > 4 Joule IES Files Available upon request
25 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 26
THT-EX L1102
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Stanchion 25° (S25) Stanchion 90° (S90)
[ Pendant Mount ] Tripod Adjustable (TA) Rotatable (RO)
[ Pendant Mount ] [ Bending Electrical Tube ] [ Bending Electrical Tube ]
235.0
2.3
2
3.
19
127.7
281.7
235.0
322.0
120.0
25° 234.0
90
45 °
251.0 25° °
Wall Mount 25° (W25) Wall Mount 90° (W90) Ceiling (C90) 200.0
285.6 242.8
375.0
3.0
347.0 Height and angle adjustable
305.0
267.3
230.0
105.0
253.2
275.0
25°
90
°
942.0
432.9
(942.0)
(1048.2)
(698.8)
Optional accessory:
Reflector (802.3)
127.5±1
97.5
Ø420.0 Ø370.0
698.8 could be added if specified
Optional wheel accessory
Reflector A Reflector B
u Please refer to Page 91, 92 for part number
27 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 28
L1102S THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications: 1432
-120 120
1074
Ø234.0 Applicable Location Applicable Area
-90 0 0 90
• Oil Refinery Complex
• Zone 1 • Zone 2 716
• Petrochemical Complex
105.0
• Zone 21 • Zone 22
• Painting Facility
188.7
Electrical Ratings
Voltage 120 V/220 V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
5000K ± 10% (Cool White)
Wattage (Amps) 50W ( 0.23、0.42A ) /95W ( 0.43、0.79A )
Operating Temperature -20°C ~ +40°C > 80 (Warm Whit
CRI
> 70 (Cool White)
Power Factor > 0.95
70 ─ 80 (Warm White)
Lum/Watt.
75 ─ 90 (Cool White)
Raw Materials
≧ 110° (Warm White)
Housing Aluminum Alloy Beam Angle
≧ 110° (Cool White)
Screws Stainless Steel
IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
29 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 30
THT-EX L1102S
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90) Stanchion 25° (S25) Stanchion 90° (S90)
[ Pendant Mount ] Tripod Adjustable (TA) Rotatable (RO)
[ Pendant Mount ] [ Bending Electrical Tube ] [ Bending Electrical Tube ]
235.0
2.3
2
3.
19
127.7
281.7
235.0
322.0
120.0
25° 234.0
251.0 90
45 °
25° °
Wall Mount 25° (W25) Wall Mount 90° (W90) Ceiling (C90) 200.0
285.6 242.8
375.0
3.0
347.0 Height and angle adjustable
305.0
267.3
230.0
105.0
253.2
275.0
25°
90
°
942.0
432.9
(942.0)
(1048.2)
(698.8)
Optional accessory:
Reflector (802.3)
127.5±1
97.5
Ø420.0 Ø370.0
698.8 could be added if specified
Optional wheel accessory
Reflector A Reflector B
u Please refer to Page 89 for part number
31 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 32
L1217 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications:
-120 120
Applicable Location
155.4
-90 0 0 90
• Zone 1 • Zone 2 • Zone 1, AEx d IIB + H 2
Ø278.0 • Zone 21 • Zone 22 • Zone 21, AEx tb IIIC
290.4
• Class I, Division 2 -60 60
243.7
• Class II, Division 2 • NEMA 6/6P -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
Electrical Ratings
Voltage 24 V/110 V/120 V/220 V/277 V/480 V AC Optical Information
Applicable Area
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT • Oil Refinery Complex
110W ( 0.5A ~ 4.58A )/120W ( 0.25A ~ 5A )/ 5000K ± 10% (Cool White)
Wattage (Amps) • Petrochemical Complex
140W (0.29A ~ 1.17A ) > 80 (Warm White)
CRI • Painting Facility
Operating Temperature - 20°C ~ + 40°C > 70 (Cool White)
• Transporting Natural Gas
Power Factor > 0.95 ≧ 90 (Warm White)
Lum/Watt. • Transporting Liquefied
≧ 100 (Cool White)
Petroleum Gas
Raw Materials ≧ 110° (Warm White)
Beam Angle • Offshore Platform
Housing Aluminum Alloy ≧ 110° (Cool White) (Oil and Natural Gas)
Screws Stainless Steel IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
33 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 34
THT-EX L1217
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Straight Electrical Tube (P90) Ceiling (C90) Triangle Stand (TSA)
Angle adjustable
268.0
220.0
172.0
10.0
268.0
268.0
70.0
368.4
243.7
70.0 272.0
342.6
Ø2
78.
25°
0
Ø278.0
287.6
Ø278.0
Stanchion 90° (S90) Stanchion 25° (S25)
[ Bending Electrical Tube ] [ Bending Electrical Tube ]
u Please refer to Page 90 for part number
366.5 442.8
275.0
25°
155
.4
455.4
155.4
0
78.
Ø2
Ø278.0
°
90
Ø278.0
Petrochemical
35 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 36
L1219B THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Net Weight: 9.5 kg Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram
Certifications:
-120 120
Ratings
Ø189.0
Petroleum Gas -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
Electrical Ratings
Optical Information
Voltage 110V/220V AC
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
Amps 0.2 ~ 0.8A 5000K ± 10% (Cool White)
Wattage 50W/60W/70W/80W > 80 (Warm White)
CRI
Operating Temperature - 20°C ~ + 40°C > 70 (Cool White)
Power Factor > 0.95 ≧ 90 (Warm White)
Lum/Watt.
≧ 100 (Cool White)
Raw Materials ≧ 110° (Warm White)
Beam Angle
Housing Aluminum Alloy ≧ 110° (Cool White)
Screws Stainless Steel IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
37 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 38
THT-EX L1219B
Standard Product (Tall Top Cover) With Accessory “Guard” (Tall Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° ( W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
459.6
395.0
417.9
480.5
25°
25°
402.6
°
90
362.3
Stanchion 25° (S25) Stanchion 90° (S90) Hanging Mount 90° (H90)
Stanchion 25° (S25G) Stanchion 90° (S90G) Hanging Mount 90° (H90G)
175.0
445.0
481.0
460.3
300.0
Ø1
542.4
89.
0
503.4
.0
189
200.0 189.0 Ø189.0
90
Pendant (P90) Ceiling (C90) °
25°
275.0
91.0
275.0
250.0
59.0
220.0
637.4
353.4
Reflector
Ø189.0
Optional accessory:
Ø371.0
Reflector
39 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 40
THT-EX L1219B
Standard Product (Short Top Cover) With Accessory “Guard” (Short Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° (W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
25° 25°
259.0
259.0 25° 259.0
259.0
259.0
466.98
489.0
369.0
391.0
25°
Pendant (P90) Stanchion 25° (S25) Hanging Mount 90° (H90) Pendant (P90G) Stanchion 25° (S25G) Hanging Mount 90° (H90G)
173.0
415.68
436.0
505.0
482.89
25°
25°
41 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 42
L1219C THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Net Weight: 9.5 kg Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram
Certifications:
-120 120
Ratings
Ø189.0
Petroleum Gas -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
Electrical Ratings
Optical Information
Voltage 24V (80W only)/110V/220V AC
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
Amps 0.2 ~ 0.8A 5000K ± 10% (Cool White)
Wattage 40W/50W/60W/70W/80W > 80 (Warm White)
CRI
Operating Temperature - 20°C ~ + 40°C > 70 (Cool White)
Power Factor > 0.95 ≧ 90 (Warm White)
Lum/Watt.
≧ 100 (Cool White)
Raw Materials ≧ 110° (Warm White)
Beam Angle
Housing Aluminum Alloy ≧ 110° (Cool White)
Screws Stainless Steel IES Files Available upon request
Tempered Glass IEC Standards impact - resistant > 4 Joule
43 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 44
THT-EX L1219C
Standard Product (Tall Top Cover) With Accessory “Guard” (Tall Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° ( W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
459.6
395.0
417.9
480.5
25°
25°
402.6
°
90
362.3
Stanchion 25° (S25) Stanchion 90° (S90) Hanging Mount 90° (H90)
Stanchion 25° (S25G) Stanchion 90° (S90G) Hanging Mount 90° (H90G)
175.0
445.0
481.0
460.3
300.0
Ø1
542.4
89.
0
503.4
.0
189
200.0 189.0 Ø189.0
90
Pendant (P90) Ceiling (C90) °
25°
275.0
91.0
275.0
250.0
59.0
220.0
637.4
353.4
Reflector
Ø189.0
Optional accessory:
Ø371.0
Reflector
45 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 46
THT-EX L1219C
Standard Product (Short Top Cover) With Accessory “Guard” (Short Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° (W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
25° 25°
259.0
259.0 25° 259.0
259.0
259.0
466.98
489.0
369.0
391.0
25°
Pendant (P90) Stanchion 25° (S25) Hanging Mount 90° (H90) Pendant (P90G) Stanchion 25° (S25G) Hanging Mount 90° (H90G)
173.0
415.68
436.0
505.0
482.89
25°
25°
47 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 48
L1239 THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
-/+180
Net Weight: 1.8kg Gas distribution
氣體分 station
配站
-150 150
0˚
90˚
180 ˚
Certifications:
-120 120
• Petrochemical Complex
• Zone 21 • Zone 22
• Painting Facility
192.4
115.0
183.4 • Transporting Natural Gas -60 60
Environmental
96.5
• Transporting Liquefied
Ratings Petroleum Gas -30 30 -180 -144 -108 -72 -36 0 36 72 108 144 180
115.0 • NEMA 6 /6P • IP 67/ 68 • Offshore Platform 0 UNIT: cd
ANGLE (DEG)
Dimension in Millimeters (Oil and Natural Gas) 0 ˚ ( 110.09˚ )
90 ˚ ( 109.65˚ )
180 ˚ ( 110.39˚ )
Electrical Ratings
Voltage 24V/110V/220V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
Wattage (Amps) 10W ( 0.05A ~ 0.42A )/20W ( 0.09A ~ 0.83A ) 5000K ± 10% (Cool White)
49 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 50
L1239 L1219D
Standard Product Warning Light
Dimensions and Mounting (Mounting Code) (Flashing Type or Rotating Type)
Hanging Mount 90°(H90) Wall Mount 25° (W25) Wall Mount 90° (W90)
Ø3
5.0
14.5
180.0 180.0
70.0
L.P.G. factory
192.4
50.0
50.0
Certifications::
96.5
203.5
.0
96.5
Ø3
• Zone 1 • Zone 2
5.0
14.5
• Petrochemical Complex
• Zone 21 • Zone 22
115.0 • Painting Facility
Environmental • Transporting Natural Gas
8.5
70.0
395.0 Ratings • Transporting Liquefied
Ø189.0
Petroleum Gas
• NEMA 6 / 6P • Offshore Platform
Pendant (P90) Stanchion 25° (S25) Stanchion 90° (S90)
Dimension in Millimeters • IP 67 / 68 (Oil and Natural Gas)
Electrical Ratings
96.
Voltage 24V/110V/220V AC
5
96.5
115.0
Operating Temperature - 20°C ~ + 40°C
25°
°
90
Raw Materials
Housing Aluminum Alloy
96.5
99.0
Optical Information
u Please refer to Page 93 for part number
Color Red/Yellow/Blue/Green
51 THT-EX reserves the right to make changes at any time in order to supply the best product possible. 44 THT-EX reserves the right to make changes at any time in order to supply the best product possible. 52
14
THT-EX L1219D
Standard Product (Tall Top Cover) With Accessory “Guard” (Tall Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° ( W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
50.0
259.0 259.0
25° 25°
459.6
417.9
480.5
395.0
25° 25°
°
90
402.6
362.3
Stanchion 25° (S25) Stanchion 90° (S90) Hanging Mount 90° (H90) Stanchion 25° (S25G) Stanchion 90° (S90G) Hanging Mount 90° (H90G)
175.0
460.3
Ø1
445.0
481.0
542.4
89.
0
503.4
300.0
Ø189.0
90
.0
189 °
189.0 25°
200.0
91.0
275.0
250.0
275.0
637.4
614.6
330.6
353.4
59.0
220.0
Ø189.0
53 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 54
THT-EX L1219D
Standard Product (Short Top Cover) With Accessory “Guard” (Short Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° (W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
25° 25°
259.0
259.0 25° 259.0
259.0
259.0
466.98
489.0
369.0
391.0
25°
Pendant (P90) Stanchion 25° (S25) Hanging Mount 90° (H90) Pendant (P90G) Stanchion 25° (S25G) Hanging Mount 90° (H90G)
173.0
415.68
436.0
505.0
482.89
25°
25°
u Please refer to Page 97 for part number (Please specify either “falsh” or “rotate” type while place order)
55 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 56
L1219A THT-EX
Warning Light Standard Product (Tall Top Cover)
(Steady on) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25)
259.0 25°
Net Weight: 8 kg
459.6
395.0
L.P.G. factory
25°
Certifications:
402.6
Ø189.0
Petroleum Gas
• NEMA 6 / 6P
445.0
481.0
• Offshore Platform
369.0 • IP 67 / 68 (Oil and Natural Gas)
Dimension in Millimeters
300.0
Electrical Ratings .0
189
Voltage 220V AC 189.0
200.0
Frequency 50Hz/60Hz
Wattage (Amps) 10W ( 0.05A ) Pendant (P90) Ceiling (C90)
Operating Temperature - 20°C ~ + 40°C
Power Factor > 0.95
275.0
Raw Materials
Housing Aluminum Alloy 614.6
330.6
Screws Stainless Steel
59.0
Globe: Tempered Glass IEC Standards impact - resistant > 4 Joule 220.0
Optical Information
Color Red Ø189.0
57 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 58
THT-EX L1219A
With Accessory “Guard” (Tall Top Cover) Standard Product (Short Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° ( W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G) Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25)
50.0 25°
259.0 259.0
25° 259.0
466.98
417.9
369.0
480.5
25°
°
90 25°
362.3
415.68
460.3
Ø1
542.4
89.
482.89
0
503.4
Ø189.0
90
° 25°
25°
250.0
637.4
353.4
marine application
59 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 60
L1219A L1219A
With Accessory “Guard” (Short Top Cover)
Emergency Eyewash
Dimensions and Mounting (Mounting Code) (Steady on)
Wall Mount 25° (W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
25°
25° 259.0
259.0
259.0
Net Weight: 8 kg
489.0
L.P.G. factory
391.0
Certifications:
189.0
Ø189.0
Petroleum Gas
436.0
• NEMA 6 / 6P
505.0
• Offshore Platform
369.0
• IP 67 / 68 (Oil and Natural Gas)
Dimension in Millimeters
Raw Materials
Housing Aluminum Alloy
Screws Stainless Steel
Globe: Tempered Glass IEC Standards impact - resistant > 4 Joule
61 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 14
62
THT-EX L1219A
Standard Product (Tall Top Cover) With Accessory “Guard” (Tall Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° ( W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
50.0
259.0 259.0
25° 25°
459.6
417.9
480.5
395.0
25° 25°
°
90
402.6
362.3
Stanchion 25° (S25) Stanchion 90° (S90) Hanging Mount 90° (H90) Stanchion 25° (S25G) Stanchion 90° (S90G) Hanging Mount 90° (H90G)
175.0
460.3
Ø1
445.0
481.0
542.4
89.
0
503.4
300.0
Ø189.0
90
.0
189 °
189.0 25°
200.0
91.0
275.0
250.0
275.0
637.4
614.6
330.6
353.4
59.0
220.0
Ø189.0
63 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 64
THT-EX L1219A
Standard Product (Short Top Cover) With Accessory “Guard” (Short Top Cover)
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Wall Mount 25° (W25) Wall Mount 90° (W90) Hanging Mount 25° (H25) Wall Mount 25° (W25G) Wall Mount 90° (W90G) Hanging Mount 25° (H25G)
25° 25°
259.0
259.0 25° 259.0
259.0
259.0
466.98
489.0
369.0
391.0
25°
Pendant (P90) Stanchion 25° (S25) Hanging Mount 90° (H90) Pendant (P90G) Stanchion 25° (S25G) Hanging Mount 90° (H90G)
173.0
415.68
436.0
505.0
482.89
25°
25°
65 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 66
L1320 THT-EX
Standard Product
Emergency Lighting
Dimensions and Mounting (Mounting Code)
10W
(Steady on) Wall Mount - Type A (WAD)
322.5
65.0
259.0
23.5
8.5
36.0
20W
X°
3
148
72.
.2
Net Weight: 5 kg Energy technology factory 318.0 X = 0°, 22.5°, 45°, 67.5°, 90°
62.5
80.0
80.0
340.7 • Zone 21 • Zone 22 • Petrochemical Complex
318.0
• Painting Facility 8.5
• Transporting Natural Gas 318.0
Environmental
• Transporting Liquefied
148.2
36.0
65.0
198.3
Electrical Ratings
148.2
72.3
8.5
Voltage 110 V/220V AC
Wattage 10W(Steady on)/20W 23.5 318.0
Raw Materials
148.2
80.0
62.5
97.3
72.3
Housing Aluminum Alloy
Screws Stainless Steel 8.5 318.0
Tempered Glass IEC Standards impact - resistant > 4 Joule
u Please refer to Page 95 for part number
67 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 68
L1601 THT-EX
Explosion-proof light tube
Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram
-/+180
150 585
-150 C0/180
Reflector ① C90/270
468
-120 120
351
-90 0 0 90
Reflector ② 234
Field installation
-60 60 117
Certifications:
0.0
-30 30
-180 -135 -90 -45 0 45 90 135 180
0 UNIT: cd
Raw Materials
Housing Aluminum Alloy
Screws Stainless Steel
Lighting Tube PC
69 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 70
THT-EX L1601
Standard Product Standard Product
Dimensions and Mounting (Mounting Code) Dimensions and Mounting (Mounting Code)
Hanging Mount 90°(H90R) Tripod (TA)
Reflector 1 A
Length of A (mm) Length of A (mm)
8.2
L :1293 L :479
20.0
M:704 M:891
S :408 S :601
200.0
A
164.0
Reflector 2 95.0
8.2
80.0
86.0
90.5
244.8 281.1
32.0
A
Length of A (mm)
L :1293
M:704
S :408
A 205.0
20.0
100.0
8.2
Reflector 2
32.0
100.5
100.5
80.5
A Field Installation
71 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 72
L1605A THT-EX
In accordance with special application requirement, THT-EX is able to offer
higher specifications on Explosion-proof LED lighting devices, includes
Certifications: 150
-120 120
113
Applicable
ApplicableLocation
Location Applicable Area
Environmental Ratings
-90 0 0 90
• •Zone • Oil Refinery Complex
Zone21 • Zone 2 • NEMA 6 / 6P 75.2
• Petrochemical Complex
• Zone
• Zone2121 • Zone 2222
326.0
• Zone • IP 67 / 68 Facility
• Painting
• Transporting Natural Gas -60 60 37.6
Environmental • Transporting Liquefied 0.0
Electrical Ratings
Voltage 110 V ~ 220 V AC Optical Information
Frequency 50Hz/60Hz 3000K ± 10% (Warm White)
CCT
Amps 0.06 A ~ 0.16 A 6500K ± 10% (Cool White)
Wattage 13W/14W/16W > 80 (Warm White)
CRI
Operating Temperature - 20°C ~ + 40°C > 80 (Cool White)
Power Factor > 0.9 IES Files Available upon request
Raw Materials
Housing Aluminum Alloy
Screws Stainless Steel
Tempered Glass IEC Standards impact - resistant > 4 Joule
73 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 74
L1605A L1605B
Standard Product
Dimensions and Mounting (Mounting Code)
Hanging Mount 25°(H25) Hanging Mount 90°(H90)
4-Ø
8.2 25°
18.0 ± 0.2 173.0±0.2
8.2
124.0±0.2
4-Ø
4-Ø 86.0±0.2
10 60.0±0.2
.2
(450.0)
Ø3
5.0
(464.0)
50.0 ± 0.2
173.0±0.2
124.0±0.2
86.0±0.2
60.0±0.2
18.0 ± 0.2
50.0 ± 0.2
Net Weight: 7kg
.2
4-Ø .0
Field installation
10
5
Ø3
Certifications:
Ø191.8
8.2
124.0±0.2 124.0±0.2
• Zone
• Zone2121 • Zone 2222
326.0
• Zone • IP 67 / 68 Facility
4-Ø
4-Ø
86.0±0.2
60.0±0.2
86.0±0.2
60.0±0.2
• Painting
• Transporting Natural Gas
Environmental • Transporting Liquefied
326.0
18.0 ± 0.2
50.0 ± 0.2
50.0 ± 0.2
.2
.2
4-Ø .0
4-Ø .0
10
10
5
5
Ø3
Ø3
• Offshore Platform
Ø191.8 • NEMA 6/ 6P • IP 67/ 68
Dimension in Millimeters (Oil and Natural Gas)
25°
Ø191.8
(346.0)
Electrical Ratings
Stanchion 25° (S25) Stanchion 90° (S90) Pendant (P90)
Voltage 110 V/220 V AC
264.9 Frequency 50Hz/60Hz
Amps 0.1 A ~ 0.245 A
(266.0)
Wattage 23W/27W
232.0
232.0
(547.0)
(450.0)
NPT1-1/2″ NPT1-1/2″
Raw Materials
(394.0) Housing Aluminum Alloy
200.0 Ø191.8
Screws Stainless Steel
Tempered Glass IEC Standards impact - resistant > 4 Joule
u Please refer to Page 98 for part number
75 THT-EX
為reserves
了 提 供 the更right
好 to的make
產 品changes
, 久 鑫at保
any留time
隨 in
時order
變 更 to supply
修 正 the best的product
設 計 權 利。 possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 76
14
THT-EX L1605B
In accordance with special application requirement, THT-EX is able to offer
Standard Product
higher specifications on Explosion-proof LED lighting devices, includes Dimensions and Mounting (Mounting Code)
Lighting can be started at low temperature -60°C Hanging Mount 25°(H25) Hanging Mount 90°(H90)
IP rating IP68
4-Ø
8.2 25°
18.0 ± 0.2 173.0±0.2
8.2
124.0±0.2
4-Ø
4-Ø 86.0±0.2
10 60.0±0.2
.2
(450.0)
Ø3
Polar Luminous Intensity Distribution Luminous Intensity Distribution Diagram 5.0
(464.0)
50.0 ± 0.2
173.0±0.2
124.0±0.2
86.0±0.2
60.0±0.2
18.0 ± 0.2
50.0 ± 0.2
.2
4-Ø .0
-/+180
10
5
Ø3
150 146
-150 C0/180
C90/270
117
-120 120
Ø191.8
87.6
Wall Mount 25° (W25) Wall Mount 90° (W90)
0 0 90
8.2
8.2
124.0±0.2 124.0±0.2
4-Ø
4-Ø
86.0±0.2 86.0±0.2
60.0±0.2 60.0±0.2
-60 60 29.2
326.0
18.0 ± 0.2
18.0 ± 0.2
50.0 ± 0.2
50.0 ± 0.2
.2
.2
4-Ø .0
4-Ø .0
0.0
-30 30
10
10
5
5
-180 -135 -90 -45 0 45 90 135 180
Ø3
Ø3
0 UNIT: cd
ANGLE (DEG)
C0 /180
C90 /270 AVERAGE BEAM ANGLE (50%) : 225.47 DEG 25°
Ø191.8
(346.0)
(266.0)
> 80 (Warm White)
232.0
232.0
CRI
> 80 (Cool White)
(381.0)
(547.0)
(450.0)
IES Files Available upon request
NPT1-1/2″ NPT1-1/2″
(394.0)
200.0 Ø191.8
77 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 78
E1215 THT-EX
Standard Product
Explosion-proof Exit Sign
Dimensions and Mounting (Mounting Code)
Ceiling (C90) Wall Mount (W90)
383.0 .5
Ø8
393.5
100.0
8.5
356.5
235.5
Certifications:
88.0
467.3
467.3 Applicable Location Applicable Area 467.3
Electrical Ratings
Voltage 100 V ~ 240V
Frequency 60Hz Equipment allocation
Wattage 4W or 8W Explosion-proof Lighting at subsea 1000 meters
Operating Temperature - 20°C ~ + 40°C
Power Factor 0.4 ~ 0.5
Charging Time 48 hours
Lighting Time 90 minutes
Raw Materials
Housing Aluminum Alloy Test conducted by Undersea Lab. of National Sun Yat-Sen University
Screws Stainless Steel Acknowledgement: Support and assistant from National Sun Yat-Sen University and DWTEK ROV
Exit Sign plate Acrylic Co. Ltd. on the Explosion-proof LED Lighting test.
79 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 80
EXP Cable Gland THT-EX
Long-Type
Product Description Without Connector
• Certificated Protection: Ex d II Gb X ▼ Without Socket Set Screw ▼ With Socket Set Screw
(Applicable Location: IIA, IIB, IIC)
• Material: Stainless Steel
• Operation temperature: -20°C ~ + 40 °C
• Thread Standards:
G
K
A
E
G
K
A
E
ISO- I EC/EN 60423, IEC/EN 50262
PF- JIS B 0202 B F
B F
NPT- ANSI B2.1
Entry Thread Cable Acceptance Gland Length Hexagon Entry Thread Cable Acceptance Gland Length Hexagon
Across Across
Part
Parl Number Thread Length “E” “F” Dimensions Part
Parl Number Thread Length “E” “F” Dimensions
Flats “G” Flats “G”
Size “A” “B” Max Min (less entry) ”K” Size “A” “B” Max Min (less entry) ”K”
Without Socket Set Screw ╱ With Socket Set Screw Without Socket Set Screw ╱ With Socket Set Screw
THT-2GM020UXd*0807 M20 19.7mm 8.0mm 7.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GG034UXd*0605 G3/4” 19.5mm 6.0mm 5.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GM020UXd*1009 M20 19.7mm 10.0mm 9.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GG034UXd*0807 G3/4” 19.5mm 8.0mm 7.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GM020UXd*1211 M20 19.7mm 12.0mm 11.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GG034UXd*8575 G3/4” 19.5mm 8.5mm 7.5mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GG012UXd*0807 G1/2” 19.7mm 8.0mm 7.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GG034UXd*0908 G3/4” 19.5mm 9.0mm 8.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GG012UXd*1009 G1/2” 19.7mm 10.0mm 9.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GG034UXd*1009 G3/4” 38 ╱ 46mm
19.5mm 10.0mm 9.0mm 67.3mm 28.5mm
THT-2GG012UXd*1211 G1/2” 19.7mm 12.0mm 11.0mm 66.7mm 23.0 mm 32 ╱ 40mm
THT-2GG034UXd*1211 G3/4” 19.5mm 12.0mm 11.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*0605 NPT3/4” 18.0mm 6.0mm 5.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GG034UXd*1413 G3/4” 19.5mm 14.0mm 13.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*0807 NPT3/4” 18.0mm 8.0mm 7.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GG034UXd*1615 G3/4” 19.5mm 16.0mm 15.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*8575 NPT3/4” 18.0mm 8.5mm 7.5mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GM025UXd*0605 M25 19.5mm 6.0mm 5.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*0908 NPT3/4” 18.0mm 9.0mm 8.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GM025UXd*0807 M25 19.5mm 8.0mm 7.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*1009 NPT3/4” 18.0mm 10.0mm 9.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GM025UXd*8575 M25 19.5mm 8.5mm 7.5mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*1211 NPT3/4” 18.0mm 12.0mm 11.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GM025UXd*0908 M25 19.5mm 9.0mm 8.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN034UXd*1413 NPT3/4” 18.0mm 14.0mm 13.0mm 67.3mm 28.5 mm 38 ╱ 46mm
THT-2GN034UXd*1615 NPT3/4” 18.0mm 16.0mm 15.0mm 67.3mm 28.5 mm 38 ╱ 46mm THT-2GM025UXd*1009 M25 19.5mm 10.0mm 9.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN012UXd*0807 NPT 1/2" 18.0mm 8.0mm 7.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GM025UXd*1211 M25 19.5mm 12.0mm 11.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN012UXd*1009 NPT 1/2" 18.0mm 10.0mm 9.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GM025UXd*1413 M25 19.5mm 14.0mm 13.0mm 67.3mm 28.5mm 38 ╱ 46mm
THT-2GN012UXd*1211 NPT 1/2" 18.0mm 12.0mm 11.0mm 66.7mm 23.0 mm 32 ╱ 40mm THT-2GM025UXd*1615 M25 19.5mm 16.0mm 15mm 67.3mm 28.5mm 38 ╱ 46mm
*— A : With Socket Set Screw Sleeve and connector are available upon request. *— A : With Socket Set Screw Sleeve and connector are available upon request.
B : Without Socket Set Screw B : Without Socket Set Screw
81 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 82
EXP Junction Box THT-EX
A Type, Without Bottom Entry A Type, With Bottom Entry
Specification Specification
• Applicable location: Zone 1, Zone 2, Zone 21, Zone 22 • Applicable location: Zone 1, Zone 2, Zone 21, Zone 22
• Material: Aluminum Alloy • Material: Aluminum Alloy
• Electrical Spec: 600V×15A, 600V×20A (Taiwan only) • Electrical Spec: 600V×15A, 600V×20A (Taiwan only)
• Entry: 1~ 4 Flank entries are available • Entry: With bottom entry and 1~ 4 Flank entries are available
• Thread: G1/2 &G3/4 (Taiwan only) , M20×1.5, M25×1.5, NPT1/2, NPT3/4 • Thread: G1/2&G3/4(Taiwan only) , M20×1.5, M25×1.5, NPT1/2, NPT3/4
• Waterproof Rating: IP68 • Waterproof Rating: IP68
• Certificated Protection: TS (Ex d IIC T6, Ex tD A21 T85°C), • Certificated Protection: TS (Ex d IIC T6, Ex tD A21 T85°C),
IECEx (Ex eb IIC T5 Gb, Ex tb IIIC T100°C Db), IECEx (Ex eb IIC T5 Gb, Ex tb IIIC T100°C Db),
ATEX (II 2 G Ex eb IIC T5 Gb, II 2 D Ex tb IIIC T100°C Db) ATEX (II 2 G Ex eb IIC T5 Gb, II 2 D Ex tb IIIC T100°C Db)
Entry Picture Size (Dimension in Millimeters) Thread Part Number Entry Picture Size (Dimension in Millimeters) Thread Part Number
G1/2 THT-2JG01201241000 G1/2 THT-2JG01201241D00
G3/4 THT-2JG03401241000 G3/4 THT-2JG03401241D00
1
122
122
79
bottom
79 Ø37
Ø37
NPT1/2 THT-2JN01201241000 Entry NPT1/2 THT-2JN01201241D00
Ø92 Ø92
NPT3/4 THT-2JN03401241000 NPT3/4 THT-2JN03401241D00
G1/2 THT-2JG01201241A00 G1/2 THT-2JG01201241E00
G3/4 THT-2JG03401241A00 G3/4 THT-2JG03401241E00
2
M20×1.5 THT-2JM02001241A00 M20×1.5 THT-2JM02001241E00
2 + Ø4.3
Ø4.3 M25×1.5 THT-2JM02501241A00 M25×1.5 THT-2JM02501241E00
bottom
79
111
79
Entry Ø37
Ø37 NPT1/2 THT-2JN01201241A00 NPT1/2 THT-2JN01201241E00
Ø92 NPT3/4 THT-2JN03401241E00
NPT3/4 THT-2JN03401241A00 Ø92
79
111
Entry
79
79
111
Entry
79
83 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 84
EXP Junction Box THT-EX
B Type, Without Bottom Entry B Type, With Bottom Entry
Specification Specification
• Applicable location: Zone 1, Zone 2, Zone 21, Zone 22 • Applicable location: Zone 1, Zone 2, Zone 21, Zone 22
• Material: Aluminum Alloy • Material: Aluminum Alloy
• Electrical Spec: 600V×20A • Electrical Spec: 600V×20A
• Entry: 1~4 Flank entries are available • Entry: With bottom entry and 1~4 Flank entries are available
• Thread: G1/ 2, G3/ 4, M20×1.5, M25×1.5, NPT 1 / 2, NPT 3 / 4 • Thread: G1 /2, G3 /4, M20×1.5, M25×1.5, NPT1 /2, NPT3 /4
• Waterproof Rating: IP68 • Waterproof Rating: IP68
• Certificated Protection: Ex d IIC T6, Ex tD A21 T85°C • Certificated Protection: Ex d IIC T6, Ex tD A21 T85°C
Entry Picture Size (Dimension in Millimeters) Thread Part Number Entry Picture Size (Dimension in Millimeters) Thread Part Number
G1/2 THT-2JG01201241H00 G1/2 THT-2JG01201241L00
G3/4 THT-2JG03401241H00 G3/4 THT-2JG03401241L00
1
126
126
74
106
M25×1.5 THT-2JM02501241H00 bottom M25×1.5 THT-2JM02501241L00
74
152
152
74
bottom
106
74
Entry
NPT1/2 THT-2JN01201241I00 NPT1/2 THT-2JN01201241M00
Ø92 NPT3/4 THT-2JN03401241I00 Ø92 NPT3/4 THT-2JN03401241M00
126 126
G1/2 THT-2JG01201241J00 G1/2 THT-2JG01201241N00
G3/4 THT-2JG03401241J00 G3/4 THT-2JG03401241N00
3
152
M20×1.5 THT-2JM02001241J00 M20×1.5 THT-2JM02001241N00
152
3 + Ø1
Ø1
M25×1.5 THT-2JM02501241J00 bottom 00 M25×1.5 THT-2JM02501241N00
74
00
106
Entry
74
152
M20×1.5 THT-2JM02001241K00 M20×1.5 THT-2JM02001241P00
152
4 Ø1
+ Ø1
00
00 M25×1.5 THT-2JM02501241K00 bottom M25×1.5 THT-2JM02501241P00
74
106
Entry
74
85 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 86
Part Number
Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10%
87
64 THT-EX reserves the right to make changes at any time in order to supply the best product possible. 88
Part Number
Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10% Part Number
Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10%
Model No. Certifications Watt. Volt. Color Part Number Model No. Certifications Watt. Volt. Color Part Number
Model No. Certifications Watt. Volt. Color Part Number Model No. Certifications Watt. Volt. Color Part Number
Class I, W.W. THT-2LA60WZ5*W1102 24V W.W. THT-2LA60Wd5*W1102
Div. 1
120V (UL844) C.W. THT-2LA60WZ5*C1102 60W 110V
Zone 1, W.W. THT-2LA60Wd5*W1102 220V C.W. THT-2LA60Wd5*C1102
60W 277V Zone 21
(UL60079) C.W. THT-2LA60Wd5*C1102 Ex db IIC T5 Gb 110V W.W. THT-2KA65Wd5*W1102
480V Class I, W.W. THT-2LA60WZ4*W1102 Ex tb IIIC T95˚C Db 65W
Div. 2 220V C.W. THT-2KA65Wd5*C1102
(UL844) C.W. THT-2LA60WZ4*C1102
120V Class I, W.W. THT-2KA65WZ4*W1102 110V W.W. THT-2KA75Wd5*W1102
65W Div. 2 75W
277V (UL844) C.W. THT-2KA65WZ4*C1102 220V C.W. THT-2KA75Wd5*C1102
• NFPA 70 (UL844) 120V Class I, W.W. THT-2KA75WZ4*W1102
L1102
75W Div. 2 II 2 G Ex db IIC T5 Gb 24V W.W. THT-2LA80Wd5*W1102
Class I, Division 1 277V (UL844) C.W. THT-2KA75WZ4*C1102 II 2 D Ex tb IIIC T95˚C Db
Class I,
80W 110V
Group B, C, D W.W. THT-2LA80WZ5*W1102 220V C.W. THT-2LA80Wd5*C1102
Div. 1
Class II, Division 1 120V (UL844) C.W. THT-2LA80WZ5*C1102
Group E, F, G Zone 1, W.W. THT-2LA80Wd5*W1102 110V W.W. THT-2KA95Wd5*W1102
80W 277V Zone 21 95W
(UL60079) C.W. THT-2LA80Wd5*C1102 220V C.W. THT-2KA95Wd5*C1102
• NFPA 70 (UL60079) 480V Class I, Ex d IIB+H 2 T5...T4 Gb
W.W. THT-2LA80WZ4*W1102 24V W.W. THT-2LA100d5*W1102
Zone 1, AEx d IIB+H2 Div. 2 DIP A21 T A 110˚C
Zone 21, AEx tb IIIC
(UL844) C.W. THT-2LA80WZ4*C1102 100W 110V
120V Class I, W.W. THT-2KA95WZ4*W1102 220V C.W. THT-2LA100d5*C1102
• UL1598 95W Div. 2
277V (UL844) C.W. THT-2KA95WZ4*C1102
L1102 • Class I, Division 2 Class I,
Div. 1
W.W. THT-2LA100Z5*W1102 Green THT-EX1219GESA11
Group A, B, C, D (UL844) C.W. THT-2LA100Z5*C1102
120V
Zone 1, W.W. THT-2LA100d5*W1102 Ex d IIB+H 2 T6 Gb Red THT-EX1219RESA11
100W 277V Zone 21
(UL60079) C.W. THT-2LA100d5*C1102 Ex tb IIIC T60˚C...T80˚C
480V Class I, W.W. THT-2LA100Z4*W1102 10W 220V
Div. 2
(UL844) C.W. THT-2LA100Z4*C1102 Green THT-EX1219GESB11
24V
110V W.W. THT-2LA60Wd5*W1102 II 2 G Ex d IIB+H 2 T6 Gb
60W Red THT-EX1219RESB11
220V II 2 D Ex tb IIIC T60˚C...
(COB) 277V
C.W. THT-2LA60Wd5*C1102
L1219A 80˚C Db
480V
Green THT-EX1219GESA12
24V
W.W. THT-2LA80Wd5*W1102 20W 220V
80W 110V Ex d IIB+H 2 T6 Gb
220V Green THT-EX1219GESB12
(COB) 277V DIP A21 TA 60˚C...80˚C
Ex d IIC T5 Gb C.W. THT-2LA80Wd5*C1102
480V
Ex tb IIIC T100˚C Db Green THT-2LA10Wd62G1219
24V 10W 220V
W.W. THT-2LA100d5*W1102
100W 110V Red THT-2LA10Wd62R1219
220V
(COB) 277V Ex d IIB + H 2 T6
C.W. THT-2LA100d5*C1102 20W 220V Green THT-2LA20Wd62G1219
480V Ex tD A21 T85˚C
Ordering information: Part number + mounting code *— 1:110V 2 : 220V 3 : 24V Ordering information: Part number + mounting code *— 1 : 110V 2 : 220V 3 : 24V
6 : 120V 9 : 277V C: 480V
91 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 92
Part Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10% Part Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10%
Model No. Certifications Watt. Volt. Color Part Number Model No. Certifications Watt. Volt. Color Part Number
Model No. Certifications Watt. Volt. Color Part Number Model No. Certifications Watt. Volt. Color Part Number
110V W,W, THT-EX1219WCCA51 110V W.W. THT-EX1219WCTA41
50W 220V W.W. THT-EX1219WECA51 40W 220V W.W. THT-EX1219WETA41
Tall top Tall top
Cover 110V C.W. THT-EX1219CCCA51 110V C.W. THT-EX1219CCTA41
Cover
Ex d IIB + H 2 T5...T4 Gb 220V C.W. THT-EX1219CECA51 220V C.W. THT-EX1219CETA41
Ex tb IIIC T90˚C...T105˚C 110V W.W. THT-EX1219WCCB51 110V W.W. THT-EX1219WCTB41
50W 40W
220V W.W. THT-EX1219WECB51 220V W.W. THT-EX1219WETB41
Short top Short top
Cover 110V C.W. THT-EX1219CCCB51 Ex d IIB + H 2 T6…T4 Gb 110V C.W. THT-EX1219CCTB41
Cover
220V C.W. THT-EX1219CECB51 Ex tb IIIC T65˚C...T105˚C 220V C.W. THT-EX1219CETB41
II 2 G Ex d IIB + H2 T5... 60W 110V W.W. THT-EX1219WCCA5A 50W 110V W.W. THT-EX1219WCTA4A
T4 Gb; II 2 D Ex tb IIIC
70W 220V W.W. THT-EX1219WECA5A 60W
T90˚C...105˚C Db 220V W.W. THT-EX1219WETA4A
80W 70W
Tall top
110V C.W. THT-EX1219CCCA5A 110V C.W. THT-EX1219CCTA4A
Tall top
Cover 220V C.W. THT-EX1219CECA5A Cover 220V C.W. THT-EX1219CETA4A
L1219B
60W 110V W.W. THT-EX1219WCCB5A 110V W.W. THT-EX1219WCTB4A
50W
70W 220V W.W. THT-EX1219WECB5A
Ex d IIB + H 2 T5...T4 Gb 60W 220V W.W. THT-EX1219WETB4A
80W L1219C II 2 G Ex d IIB + H2 T6…
DIP A21 TA 90˚C...105˚C Short top 110V C.W. THT-EX1219CCCB5A 70W
110V C.W. THT-EX1219CCTB4A
T4 Gb, II 2 D Ex tb IIIC Short top
Cover 220V C.W. THT-EX1219CECB5A
T65˚C...105˚C Db Cover 220V C.W. THT-EX1219CETB4A
W.W. THT-2LA50Wd52W1219
50W 220V 24V W.W. THT-EX1219WATA42
C.W. THT-2LA50Wd52C1219
110V W.W. THT-EX1219WCTA42
W.W. THT-2LA60Wd52W1219 80W
60W 220V 220V W.W. THT-EX1219WETA42
C.W. THT-2LA60Wd52C1219 Tall top
Cover
24V C.W. THT-EX1219CATA42
W.W. THT-2LA70Wd52W1219
Ex d IIB + H 2 T5 Gb 70W 220V 110V C.W. THT-EX1219CCTA42
Ex tb IIIC T135˚C Db C.W. THT-2LA70Wd52C1219
220V C.W. THT-EX1219CETA42
W.W. THT-2LA80Wd52W1219 Ex d IIB + H 2 T6...T4 Gb
80W 220V 24V W.W. THT-EX1219WATB42
C.W. THT-2LA80Wd52C1219 DIP A21 T A 65˚C...105˚C
110V W.W. THT-EX1219WCTB42
10W 110V 80W 220V W.W. THT-EX1219WETB42
C.W. THTE1320ANCCAA0
Steady on 220V Short top
24V C.W. THT-EX1219CATB42
L1320 Cover
Ex d IIC T6 Gb 110V 110V C.W. THT-EX1219CCTB42
20W C.W. THTE1320ZNCCAB0
Ex tb IIIC T85˚C Db 220V 220V C.W. THT-EX1219CETB42
Ordering information: Part number + mounting code Ordering information: Part number + mounting code
95 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 96
Part Number
Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10% Part Number
Number ● W.W.: 3000K ± 10% ● C.W.: 5000K ± 10%
Model No. Certifications Watt. Volt. Color Part Number Model No. Certifications Watt. Volt. Color Part Number
Red THT-EX1219RAWA01 110V W.W. THTH1601DNHW1A0
220V W.W. THTH1601DNHW2A0
Yellow THT-EX1219YAWA01 277V W.W. THTH1601DNHW9A0
10W 24V 10W
Ex d IIB + H 2 T6 Gb 110V C.W. THTH1601DNHC1A0
Blue THT-EX1219BAWA01
Ex tb IIIC T55˚C
220V C.W. THTH1601DNHC2A0
Green THT-EX1219GAWA01 277V C.W. THTH1601DNHC9A0
∼
110V W.W. THTE1303CABW1F0 220V C.W. THTE1605BBFCAA6
220V W.W. THTE1303CABW2F0 W.W. THTE1605ABGW2B3
L1303C 60W 23W 220V
Ex d IIC T6 X
24V C.W. THTE1303CABC3F0 C.W. THTE1605ABGC2B3
Ex tD A21 IP67 T85˚C
110V C.W. THTE1303CABC1F0 W.W. THTE1605ABGW1B7
110V
220V C.W. THTE1303CABC2F0 C.W. THTE1605ABGC1B7
W.W. THTE1303CABW1I0
L1605B 110V W.W. THTE1605BBGW1B7
110V Ex nR IIC T5 Gc 27W
C.W. THTE1303CABC1I0 220V W.W. THTE1605BBGW2B7
90W Ex tb IIIC T100˚C Db
W.W. THTE1303CABW2I0 110V C.W. THTE1605BBGC1B7
220V
C.W. THTE1303CABC2I0 220V C.W. THTE1605BBGC2B7
Ordering information: Part number + mounting code Ordering information: Part number + mounting code
97 THT-EX reserves the right to make changes at any time in order to supply the best product possible. THT-EX reserves the right to make changes at any time in order to supply the best product possible. 98
CLASS I Flammable Gases, Vapors or Liquids
Area Classification International Protection Techniques (Equipment Protection Levels)
Division 1: Zone 0: Zone 1: Applicable Certification Documents
Where ignitable concentrations of where ignitable concentrations Where ignitable concentrations Protection Techniques
flammable gases, vapors or liquids of flammable gases, vapors or of flammable gases, vapors or Area (Equipment Protection Levels) IECEx System Europe USA Canada
can exist all of the time or some of liquids are present continuously liquids are likely to exist under Zone 0 • Intrinsic safety,"ia"(Ga) IEC 60079-11 EN 60079-11 UL 60079-11 CSA 60079-11
the time under normal operating or for long periods of time under normal operating conditions. • Encapsulation,"ma"(Ga) or IEC 60079-18 EN 60079-18 UL 60079-18 CSA 60079-18
conditions. normal operating conditions. "m" for CAN
• Class I,Div 1 intrinsic safety — — UL 913 CSA 157
Division 2: Zone 2: Zone 1 • Flameproof,"d"(Gb) IEC 60079-1 EN 60079-1 UL 60079-1 CSA 60079-1
Where ignitable concentrations of where ignitable concentrations of • Pressurization,"px" or "py"(Gb) IEC 60079-2 EN 60079-2 ISA 60079-2 CSA 60079-2
flammable gases, vapors or liquids flammable gases, vapors or liquids or "p" fo4 CAN
are not likely to exist under normal are not likely to exist under normal • Powder filling,"q" (Gb) IEC 60079-5 EN 60079-5 UL 60079-5 CSA 60079-5
operating conditions. operationg conditions. • Oil immersion,"o" (Gb) IEC 60079-6 EN 60079-6 UL 60079-6 CSA 60079-6
• Increased safety,"e"(Gb) IEC 60079-7 EN 60079-7 UL 60079-7 CSA 60079-7
• Intrinsic safety,"ib"(Gb) IEC 60079-11 EN 60079-11 UL 60079-11 CSA 60079-11
Groups Temperature Classes • Encapsulation, "mb" (Gb) or IEC 60079-18 EN 60079-18 UL 60079-18 CSA 60079-18
Division 1 and 2: Zone 0, 1 and 2: Division 1 and 2: Zone 0, 1 and 2: "m" for CAN
T1 (≤450°C) T1 (≤450°C) • Any Zone 0 technique See above See above See above See above
A (acetylene) IIC (acetylene & hydrogen) • Any Class I, Div 1 technique — — See USA See CAN
T2 (≤300°C) T2 (≤300°C)
B (hydrogen) IIC (acetylene & hydrogen) CID1 tech. CID1 tech.
T2A (≤280°C) —
C (ethylene) IIB (ethylene) Zone 2 • Pressurization,"pz"(Gc) or IEC 60079-2 EN 60079-2 ISA 60079-2 CSA 60079-2
T2B (≤260°C) —
D (propane) IIA (propane) "n" for CAN
T2C (≤230°C) —
• Intrinsic safety,"ic"(Gc) or IEC 60079-11 EN 60079-11 UL 60079-11 CSA 60079-11
T2D (≤215°C) —
"n" for CAN
T3 (≤200°C) T3 (≤200°C) • Encapsulated,"nC"(Gc) — — — CSA 60079-15
T3A (≤180°C) — • Enclosed-break,"nC"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
T3B (≤165°C) — • Energy-limited,"nL"(Gc) — — — CSA 60079-15
T3C (≤160°C) — • Hermetically-sealed,"nC"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
T4 (≤135°C) T4 (≤135°C) • Nonincendive,"nC"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
T4A (≤120°C) — • Non-sparking,"nA"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
T5 (≤100°C) T5 (≤100°C) • Restricted breathing,"nR"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
T6 (≤85°C) T6 (≤85°C) • Sealed,"nC"(Gc) IEC 60079-15 EN 60079-15 UL 60079-15 CSA 60079-15
• Encapsulation,"mc"(Gc) or IEC 60079-18 EN 60079-18 UL 60079-18 CSA 60079-18
North American Protection Techniques "n" for CAN
• Any Zone 0 or 1 technique See above See above See above See above
Applicable Certification Documents • Any Class 1, Div 1 or 2 — — See USA CID1 See CAN CID1
technique or CID 2 tech. or CID2 tech.
Area Protection Techniques USA Canada
Note 1: Zone 0,1 and 2 general requirements are contained in UL 60079-0 (USA), CSA 60079-0 (Canada) and
Div.1 • Intrinsic safety UL 913 CSA 157
IEC / EN 60079-0 (IECEx System & Europe).
• Explosionproof UL 1203 CSA 30
Note 2: Zone 0, 1 and 2 intrinsically safe system requirements are contained in ISA 60097-25 (USA & Canada)
• Purged/pressurized (Type X or Y) NFPA 496 NFPA 496
and IEC/EN 60079-25 (IECEx System & Europe).
• Any Class I, Zone 0 technique See USA Zone 0 tech. See CAN Zone 0 tech. Note 3: Special requirements for equipment installed in Zone 0 (Ga) areas are contained in ISA 60079-26 (USA)
Div.2 • Hermetically-sealed ISA 12.12.01 CSA 213 and IEC/EN 60079-26 (IECEx System & Europe).
• Nonincendive ISA 12.12.01 CSA 213 Note 4: Equipment Protection Levels (EPLs) are used to provide additional details regarding the level of protection
• Non-sparking ISA 12.12.01 CSA 213 against ignition in explosive atmospheres.EPLs are designated by a letter "G" for Gas, "D" for Dust or "M"
• Purged / pressurized (Type Z) NFPA 496 NFPA 496 for Mining, followed by a letter "a" for "very high", "b" for "high" or "c" for “enhanced” level of protection.
• Sealed ISA 12.12.01 CSA 213 Note 5: Under the ATEX Directive (94/9/EC), the marking of Categories is additionally required. ATEX Categories
are similar to EPLs in function and designation as follows, ATEX Category 1G, 2G, 3G, 1D, 2D, 3D, M1,
• Any Class I, Division 1 technique See above See above
M2 = EPL Ga, Gb, Gc, Da, Db, Dc, Ma, Mb respectively.
• Any Class I, Zone 0,1 or 2 technique See USA Zone 0,1 or 2 tech. See CAN Zone 0,1 or 2 tech.
Note 6: INMETRO certification requirements are determined by Portaria 179 as of 18 May 2010, with the associated
Note: Class I, Division 1 intrinsically safe system requirements are contained in UL913(USA) and CSA157(Canada). Brazilian NBR Ex standards harmanized with the comparable IEC Ex standards noted above.
99 100
CLASS II Combustible Dusts
Area Classification International Protection Techniques (Equipment Protection Levels)
Division 1: Zone 20: Zone 21: Applicable Certification Documents
Where ignitable concentrations of Where ignitable concentrations of Where ignitable concentrations of Protection Techniques
combustible dust can exist all of combustible dust or ignitable fibers combustible dust or ignitable fibers Area (Equipment Protection Levels) IECEx System Europe USA Canada
the time or some of the time under / flyings are present continuously / flyings are likely to exist under
Zone 20 • Enclosure, "ta" (Da) IEC 60079-31 EN 60079-31 ISA 60079-31 —
normal operating conditions. or for long periods of time under normal operating conditions. • Intrinsic safety, "ia" (Da) IEC 60079-11 EN 60079-11 UL 60079-11 —
normal operating conditions. • Encapsulation, "ma" (Da) IEC 60079-18 EN 60079-18 UL 60079-18 —
Division 2: Zone 22: • Any Class II, Div 1 technique — — See USA CIID1 —
tech.
Where ignitable concentrations of Where ignitable concentrations of
combustible dust are not likely to combustible dust or ignitable fibers Zone 21 • Enclosure, "tb" (Db) or "t" for USA IEC 60079-31 EN 60079-31 ISA 60079-31 —
exist under normal operating /flyings are not likely to exist under • Pressurization, "p" (Db) IEC 61241-4 EN 61241-4 ISA 61241-2 —
conditions. normal operating conditions. • Intrinsic safety, "ib" (Db) IEC 60079-11 EN 60079-11 UL 60079-11 —
• Encapsulation, "mb" (Db) IEC 60079-18 EN 60079-18 UL 60079-18 —
Groups Temperature Classes • Any Zone 20 technique See above See above See above —
• Any Class II, Div 1 technique — — See USA CIID1 —
Division 1 and 2: Zone 20, 21 and 22: Division 1 and 2: Zone 20, 21 and 22: tech.
E (metal dust — Div. 1 only) IIIC (conductive dust) T1 (≤ 450°C) None. Zone 22 • Enclosure, "tc" (Dc) IEC 60079-31 EN 60079-31 ISA 60079-31 —
F (carbonaceous dust) IIIB (non-conductive dust) T2 (≤ 300°C) Note: For Zone 20, 21 • Pressurization, "p" (Dc) IEC 61241-4 EN 61241-4 ISA 61241-2 —
G (non-conductive dust) IIIB (non-conductive dust) T2A (≤ 280°C) and 22, equipment • Intrinsic safety, "ic" (Dc) IEC 60079-11 EN 60079-11 UL 60079-11 —
— IIA (combustible flyings) T2B (≤ 260°C) shall be marked to • Encapsulation, "mc" (Dc) IEC 60079-18 EN 60079-18 UL 60079-18 —
T2C (≤ 230°C) show the operating • Any Zone 20 or 21 technique See above See above See above —
T2D (≤ 215°C) • Any Class II, Div 1 or 2 technique — — See USA CIID1 —
temperature
T3 (≤ 200°C) or CIID2 tech.
(maximum surface
T3A (≤ 180°C)
temperature) Note 1: Zone 20, 21 and 22 general requirements are contained in UL 60079-0 or ISA 61241-0 (USA), and IEC/EN
T3B (≤ 165°C)
60079-0 or IEC 61241-0 (IECEx System & Europe).
T3C (≤ 160°C)
Note 2: Equipment Protection Levels (EPLs) are used to provide additional details regarding the level of protection
T4 (≤ 135°C)
against ignition in explosive atmospheres.EPLs are designated by a letter "G" for Gas, "D" for Dust or "M"
T4A (≤ 120°C)
for Mining, followed by a letter "a" for "very high", "b" for "high" or "c" for "enhanced" level of protection.
T5 (≤ 100°C) Note 3: Under the ATEX Directive (94 /4 /EC), the marking of Categories is additionally required. ATEX Categories
T6 (≤ 85°C) are similar to EPLs in function and designation as follows, ATEX Category 1G, 2G, 3G, 1D, 2D, 3D, M1,
M2 = EPL Ga, Gb, Gc, Da, Db, Dc, Ma, Mb respectively.
North American Protection Techniques
Note 4: INMETRO certification requirements are determined by Portaria 179 as of 18 May 2010, with the associated
Applicable Certification Documents Brazilian NBR Ex standards harmanized with the comparable IEC Ex standards noted above.
101 102
Explanation of IP Rating Ex Protection Concepts - Electrical
The IP Rating, Ingress Protection Rating, sometimes also interpreted as International Protection In areas where explosive atmospheres can occur despite the explosion protection measures
Rating, classifies and rates the degree of protection provided against the intrusion of solid objects employed, only explosion- proof electrical equipment may be used. Explosion proof electrical
(including body parts like hands and fingers), dust, accidental contact, and water in mechanical equipment can be manufactured to IEC protection type levels.
casings and with electrical enclosures. Types of protection for electrical apparatus in hazardous areas:
1st Digit Protection from solid objects 2nd Digit Protection from moisture Electrical Symbol Typical Zone Diagram IEC Standard Basic concept of protection
ia 0, 1, 2
3 Protected against solid Protected against
objects greater than 4 splashing water. Intrinsic safety ib 1, 2 IEC 60079-11
Limit the energy of
2.5mm ic 2
sparks and surface
Type ‘n’ temperatures
nL 2 IEC 60079-15
4 Protected against solid Protected against (energy limitation)
5 water jets.
objects greater than
1.0mm
Quartz/sand filled q 1, 2 IEC 60079-5 Quench the flame
Protect against
6 p 1, 2
heavy seas.
Dust protected px 1, 2
5 Pressurised IEC 60079‐2
py 1, 2
pz 2
Protected against
the effects of Type ‘n’
7 nC 2
immersion between (sealing & hermetic sealing)
IEC 60079‐15
150mm to 1m. Type ‘n’
nR 2 Keep the flammable
(restricted breathing)
6 Dust tight Protected against
gas out
continuous
8 ma 0, 1, 2
submersion at IEC 60079‐18
Encapsulation
specified depth.
mb 1, 2
Example: IP 6 7
2nd Digit ― Protected against the effects of immersion between 150mm to 1m. Oil immersion o 1, 2 IEC 60079‐6
Code Letter 1st Digit ― Dust tight
103 104
Explosion-proof
LED Lighting