Professional Documents
Culture Documents
♦ 1 to 14 outputs
♦ Standard or Configurable
♦ No Minimum Load
♦ Rapid Connection
♦ Wide Range Input
♦ EN61000-3-2 Compliant
♦ Class B Conducted
♦ Low Leakage Medical Versions
Typical Applications
Computer Peripherals, Telecoms, Industrial Equipment, Office Automation, Instrumentation, Test &
Measurement, OEM Applications etc.
INPUT
Input Voltage 85 – 264VAC, 120 – 360VDC (DC input Alpha 600 & 1000 only)
Power Factor Typically > 0.95¹
Inrush Current < 50A
Fuse Internal fuse (no user access)
Input Frequency 47 to 63Hz
Isolation Input to Output 3kVRMS Input to Ground 1.5kVRMS
Leakage Current <1.1mA 260VAC 50Hz²
Note 1 Reduced PFC >255VAC
Note 2 See Input Filter Options for low leakage versions
OUTPUT
SAFETY APPROVALS
WARRANTY 3 Years
Max.
Part Number O/P 1 O/P 2 O/P 3 O/P 4
Power
Volts Amps Volts Amps Volts Amps Volts Amps
CA400 5A 300W 5V 60A
CA400 5S 400W 5V 80A
CA400 12F 396W 12V 33A
CA400 24G 400W 24V 16.6A
CA400 5A 12C 12C 400W 5V 60A 12V 16A 12V 16A
CA400 5A 12/12E 24N 400W 5V 60A 12V 8A 12V 8A 24V 5A
CA600 5APP 5APP 600W 5V 120A
CA600 24G 600W 24V 25A
CA600 5A 12C 12C 600W 5V 60A 12V 16A 12V 16A
CA600 5A 3.3Q 12C 12C 600W 5V 60A 3.3V 25A 12V 16A 12V 12A
CA600 5A 24D 12/12E 600W 5V 60A 24V 8A 12V 6A 12V 6A
CA1000 B/S 5A 12F 12F 1000W 5V 60A 12V 33A 12V 20A
CA1000 12C 5A 3.3R 12F 1000W 5V 60A 3.3V 60A 12V 20A 12V 16A
You can configure your own combination of outputs by following the tables below or visit
www.lambda-gb.com / clips.htm and try our Rapid Selector online to instantly configure an
Alpha of your choice.
18/02/00 – Issue 3
Input filter
option
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7
CA
CA1000 only
Converter Primary
power Secondary option available on Slot 1 to 5 (7)
options
output
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Alpha 400 and 600
Slot 7
Slot 6
Slot 5
Slot 4
Slot 3
Slot 2
Slot 1
Alpha 1000
NOTE : Module derating applies in Slot 4 and 5 when used in Alpha 400 and 600 Consult Technical
Sales for details.
18/02/00 – Issue 3
Adjustment Range
Line Regulation
Output Current
Remote Sense
Output Noise
Single
connected)
No of Slots
Output
Options
A 5V 4.5-5.5V 60A 0.5V 6.26-7.0V 1% 2% <0.5% <0.5% 2 PP,PA,INH,MF
B 5V 4.5-5.5V 25A 0.5V 6.0-7.0V 1% 2% <0.5% <0.5% 1 PP.PA,INH,MF
1%,Vo≥10V 2%,Vo≥10V
¬
C¬ 12V 5-15V 16A 1V 16.8-18.1V <0.5% <0.5% 1 PP,PA,INH,MF
2%,Vo<10V 3%,Vo<10V
D 24V 18-28V 8A 1V 33.4-36.2V 1% 2% <0.5% <0.5% 1 PP,PA,INH,MF
F 12V 9-15V 33A 1V 16.8-18.1V 1% 2% <0.5% <0.5% 2 PP,PA,INH,MF
G 24V 17.5-28V 25A 1V 33.5-40.0V 1% 2% <0.5% <0.5% 2 PP,PA,INH,MF
-
J- 36V 36-48V 10A 1V 51.0-58.0V 1% 2% <0.5% <0.5% 2 INH,MF
K 24V 18-28V 15A 1V 32.8-35.0V 1% 2% <0.5% <0.5% 2 MF
¯
L¯ 2V 1.8-2.7V 25A 0.5V 3.7-4.1V 50mV 100mV 25mV 50mV 1 MF
M 12V 5-15V 8A 1V 16.8-18.1V 1% 2% <0.5% <0.5% 1 PP,PA,INH,MF
®
N® 24V 18-31V 5A 1V 33.4-36.2V 1% 2% <0.5% <0.5% 1 PP,PA,INH,MF
Q 3.3V 2.7-3.4V 25A 0.5V 4.26-4.6V 1% 2% <0.5% <0.5% 1 PP,PA,INH,MF
R 3.3V 2.7-3.4V 60A 0.5V 4.26-4.6V 1% 2% <0.5% <0.5% 2 PP,PA,INH,MF
S 5V 2.5-5.2V 85A 0.5V 6.26-7.0V 1% 2% <0.5% <50Mv 2 PA,MF
¯
T¯ 2V 1.8-2.7V 60A 0.5V 3.7-4.1V 50mV 100mV 25mV 50mV 2 MF
Z 5V 4.5-5.5V 25A 0.5V 5.7-6.0V 1% 2% <0.5% <0.5% 1 PP,PA,INH,MF
NOTES:
Load Regulation
Line Regulation
Output Voltage
Output Current
Remote Sense
Over Voltage
No of Slots
Twin
Protection
Output
Options
Preset
BW)
KHz
18/02/00 – Issue 3
Specifications:
Notes
1. The ‘AC Fail’ signal is generated a minimum of 5mS before the PSU output goes out of specification.
2. If the AC input voltage falls to a level where it approaches the operational threshold, there will be repetitive
operation of the power fail indication. Below this threshold a constant indication of power failure occurs.
PSU INHIBIT INPUT - A TTL compatible control input referenced to the auxiliary supply 0 volts.
- ‘LOW’ ≤.8 volts at 5mA = PSU INHIBITED
- ‘HIGH’ ≥ 2.0 volts or open-circuit = PSU ON
AUXILIARY SUPPLY - Output – 5 volts ± 5% at 50mA maximum Load regulation: better than 1%
18/02/00 – Issue 3
PP: Parallel for Power: The outputs of PA: Parallel for Redundancy: This allows
individual modules are connected together by modules in the same or different power
bus-bars in order to give higher current supplies to be connected in N+1 redundancy.
outputs. The modules are factory pre-set and Please contact the Sales Office for an
must not be re-adjusted by the user. The only Application Note and availability.
limitation is that the modules must be adjacent.
No output signals are provided as part of the The option integrates Remote Sense with the
PP Option. Check for availability. Parallel signal (‘Star point’) and a TTL
compatible open collector Module Good signal,
(electrically similar to ‘AC fail’), used for
identifying a faulty module in a parallel
combination.
18/02/00 – Issue 3
CONNECTOR MOULDINGS
Pt No
AC INPUT 88537
DC OUTPUT
SINGLE SLOT SINGLE O/P 88538
SINGLE SLOT TWIN O/P 88539
DUAL SLOT SINGLE O/P 88540
CONNECTION DETAILS
18/02/00 – Issue 3
Alpha 400
Alpha 600
18/02/00 – Issue 3
Alpha 1000
18/02/00 – Issue 3
AUSTRIA ITALY
LAMBDA ELECTRONIC GmbH LAMBDA ELECTRONICS s.r.l.
Via Gewerbering 6, D85659 Via Fratelli Gracchi, 36-20092 Cinisello Balsamo (MI) Italy
Telephone: +43 2 256 65584 Telephone: +39 2 6604 0540
Facsimile: +43 2 256 64412 Facsimile: +39 2 6604 0650
BELGIUM JAPAN
MULDER-HARDENBERG N.V. NEMIC LAMBDA KK,
Hoge Weg 129, Stabroek 2940, Belgium 1-11-15 Higashigotanda, Shinagawa-Ku, Tokyo 141
Telephone: +32 3 6601320 Telephone: +81 3 3447 4411
Facsimile: +32 3 6649901 Facsimile: +81 3 3447 7784
CANADA KOREA
LAMBDA ELECTRONICS (CANADA) INC., NEMIC LAMBDA
16829B Hymus Boulevard, Kirkland, Quebec, 6F Sungok Bldg, 4-1 Soonae-Dong, Boondang-Gu
Canada, H9H 344 Sungnam-Shi, Kyonggi-Do, KOREA
Telephone: +1 514 6958330 Telephone: +82 2 556 1171 (2)
Facsimile: +1 514 6958168 Facsimile: +82 2 555 2706
DENMARK SINGAPORE
LAMBDA SCANDINAVIA NEMIC LAMBDA (S) PTE LTD
Soebakken 24, DK-3450 Alleroed, Denmark 1008 TOA Payoh North #07-06, Singapore 1231
Telephone: +45 4 817 6839 Telephone: +65 251 7211
Facsimile: +45 4 817 6819 Facsimile: +65 250 9171
FRANCE SWEDEN
LAMBDA COUTANT SA, LAMBDA SCANDINAVIA
BP 77, 91943 Les Ulis Cedex, France. Hörnåkersvägen 8, S-183 65 Täby, Sweden
Telephone: +33 1 60121487 Telephone: +46 8 630 0695
Facsimile: +33 1 60122794 Facsimile: +46 8 630 1228
FINLAND SWITZERLAND
LAMBDA SCANDINAVIA CL ELECTRONICS GmbH,
P.O. Box 54, Koskelontie 13, FIN-02921 Postfach 162, CH-8165, Oberweningen, Switzerland
Espoo, Finland Telephone: +41 1 8561923
Telephone: +358 9 452 66 525 Facsimile: +41 1 8561892
Facsimile: +358 9 452 66 568
GERMANY USA
LAMBDA ELECTRONICS GmbH, LAMBDA ELECTRONICS INC,
Postfach 1367, D-77844 Achern, Germany 515 Broad Hollow Road Melville L.I., New York 11747-
Telephone: +36 1 459 8010 3700, U.S.A
Facsimile: +36 1 459 8019 Telephone: +1 516 6944200
Facsimile: +1 516 2930519
HUNGARY
ENER-GOM INDUSTRIAL AND TRADING LTD
Koranyi Sandor U. 3/B, Budapest
Hungary, H-1089
Telephone: +36 1 459 8010
Facsimile: +36 1 459 8019
Coutant Lambda Ltd, Telephone – Head Office +44 (0) 1271 856600
Kingsley Avenue, Telephone – UK Sales +44 (0) 1271 856666
Ilfracombe, Telephone – Export Sales +44 (0) 1271 856699
Devon Facsimile – +44 (0) 1271 864894
EX34 8ES. Email - intouch@lambdaeu.com
United Kingdom Website Address - http://www.lambda-gb.com
While every effort is made to ensure accuracy, we cannot accept responsibility arising from errors or changes to this specification. Coutant Lambda Ltd reserves the right to
amend this data in line with ongoing product development.
18/02/00 – Issue 3