Dimension
L * W * H
278 * 177.8 * 63.5 (2U) mm
10.9 * 7 * 2.5 (2U) inch
UL62368-1 IEC62368-1
EN62368-1
■ Features ■ Applications
AC input 180~264VAC Factory control or automation apparatus
Built-in active PFC function Test and measurement instrument
High efficiency up to 93% Laser related machine
Forced air cooling by built-in DC fans UV curing equipment
Output voltage / current programmable Fish lamp
Active current sharing up to 7200W(2+1) Burn-in facility
Built-in remote ON-OFF control /
auxiliary power / power OK signal
Protections: Short circuit / Overload / Over voltage
/ Over temperature / Fan failure
Optional conformal coating
5 years warranty
■ Description
CSP-3000 is a 3KW single output enclosed type AC/DC power supply. This series operates for 180~264VAC
input voltage and offers the models with the DC output mostly demanded from the industry. Each model is
cooled by the built-in fan with fan speed control, working for the temperature up to 70℃. Moreover,
CSP-3000 provides vast design flexibility by equipping various built-in functions such as the output
programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
PFC O.V.P.
CONTROL O.L.P.
PWM
DETECTION
O.T.P. CONTROL CIRCUIT P OK
REMOTE RC
LOAD CONTROL
SHARING
CS
FAN
AUX RECTIFIERS
POWER & AUX POWER
FILTER (12V/0.4A)
100
100
90
80
80
LOAD (%)
LOAD (%)
70 60
60 50
40
50
20
40
94
92
90
EFFICIENCY (%)
88
86
84
82
80
78
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
◎ CSP-3000-120 ◎ CSP-3000-250
130V 260V
1.36A, 250V 9A,250V
12A, 250V
125V
2.4A, 120V 15A,120V
240V
120V 25A,120V
220V
115V
110V 200V
105V 180V
17A, 176.5V
100V 30A,100V
160V
95V
140V
90V 30A,90V
2.4A, 90V 17A, 125V
85V 120V
1.36A, 125V
80V 100V
0A 5A 10A 15A 20A 25A 30A 35A 0A 3A 6A 9A 12A 15A 18A
Recommended High Performance Region Allowed Operational Region Recommended High Performance Region Allowed Operational Region
◎ CSP-3000-400
430V
0.8A, 400V 5.25A,400V 7.5A, 400V
400V
370V
340V
10A,300V
310V
280V
250V
220V
190V
0.8A, 200V 10A,200V
160V
130V
100V
0A 1.5A 3A 4.5A 6A 7.5A 9A 10.5A 12A 13.5A 15A
Function Manual
1. Output Voltage/Current Programming
※ Mode Setting
CN1:
CONDITION MODE FUNCTION
PIN6
PIN5
PV/PC MODE CHOSE
CN1
PV/PC SET(SVR2)
max.
PIN8
PIN7 PV/PC SET PIN6
PIN5 PV/PC ADJUST
CN2
100 100
OUTPUT CURRENT SET (%)
OUTPUT VOLTAGE SET (%)
80 Non-Linear 80 Non-Linear
MODEL 120V 250V 400V MODEL 120V 250V 400V
40 40
20 20
(V) (V)
2 4 6 8 10 2 4 6 8 10
◎ For fast output response, it is recommended to adjust through CN2 terminal PIN5/PIN6,
applying additive 10V PWM signal(frequency range 500Hz~1KHz).
Vout
OUTPUT VOLTAGE / CURRENT ADJ. (%)
100
80 Non-Linear
60
40
MODEL 120V 250V 400V
V
0.8 4 6 8 10
2.Remote ON-OFF
※ Remote ON-OFF is activated by the configuration with respect to CN1 as shown in the following diagram.
PIN3 RC
PIN1 RCG
CN1
AUX
1KΩ 12V
RC
Internal
12V typ.
SW
RCG
AUXG
AUX
1KΩ RC
Internal
12V typ.
RCG
SW
AUXG
AUX
1KΩ
1KΩ RC
Internal
12V typ. SW
RCG
AUXG
◎ Connection Method
Example 2.2(A) Example 2.2(B) Example 2.2(C)
Power supply output ON SW Open(open) SW Open(open) SW Close(short)
SW Logic
Power supply output OFF SW Close(short) SW Close(short) SW Open(open)
PIN9(P-OK-GND) PIN4(P-OK-GND-2)
PIN7(P-OK) PIN2(P-OK-2)
CN1
Function Description Output of alarm(P OK, Relay Contact) Output of alarm(P OK2, TTL Signal)
The signal is "Low" when the power supply is above Low Low
80% of the rated output voltage, or, say, Power OK (0.5V max at 500mA) (0.5V max at 10mA)
P OK
The signal turns to be "High" when the power supply
High or open High or open
is under 80% of the rated output voltage, or, say,
(External applied voltage, 500mA max.) (External applied voltage, 10mA max.)
Power Fail
P OK P OK2
R R
V 0.1uF V
Fig. 3.2 Internal circuit of P OK (Relay, total is 10W) Fig. 3.3 Internal circuit of P OK2 (Open collector method)
4.Current Sharing
CSP-3000 has the built-in active current sharing function and can be connected in parallel, up to 3 units, to provide higher output power as exhibited below :
※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
※ Difference of output voltages among parallel units should be less than 0.2V(Can Fine tune by SVR1).
※ The total output current must not exceed the value determined by the following equation:
Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9
※ When out current<( 50% rate current)×(Number of unit),
the current shared among units may not be fully balanced.
+V
-V
+V
No.2(Slave) Load
-V
+V
-V
No.3(Slave)
+V
-V
Mechanical Specification
Case No.982B Unit:mm
278
236.3 27
12.5
63.5
CN1 CN2
38
1 1
10 8 6 4 2 8642
236.3 27 19max.
7.9
4-M4 L=5mm
16
1 1
13
OUTPUT
177.8
Air flow
162
direction
INPUT
10
13
1 1
16max.
1 2
7 8
Mating Housing FJY 3521-1000204-1803 or equivalent
1 2 Terminal FJY 256-210000-22119 or equivalent
Installation Manual
Please refer to : http://www.meanwell.com/manual.html