Professional Documents
Culture Documents
1
Wiring Diagram – “Fail Secure” Electric Lock, 3rd Party Power Supply
2
Wiring Diagram – “Fail Secure” Electric Strike, PoE Power Supply, Wi-Fi
3
4
Secure Open Door Wiring
• GSC3570 Inside
• GDS37xx Outside
• Other accessories/sensors
GSC3570 Connection & Wiring Diagrams - “Fail Secure” Electric Strike, POE Power Supply
WiFi
GSC3570 Connection & Wiring Diagrams - “Fail Secure” Electric Strike, POE Power Supply
AIN1
AIN2
AIN3
GND
IN+
POE power supply
802.3af 12.5W
POE Switch
Back Doorbell
(Manual open door
not illustrated)
GSC3570 Interface table
GSC3570 INTERFACE TABLE
Jack Pin Signal Colour Function Remark
1 COM1 Orange
1 Relay output,normal open or close, max
2 NO1 Yellow Alarm Out
125VAC/0.5A or max DC 30V/2A
3 NC1 Green
Alarm isolated input, for voltage signal detection,
Alarm In IN+ connect the sensor's signal output, please
4 IN+ White
(Active) connect the GND to Alarm device's GND or
Negative of power . Active voltage range 9-15V
Voltage reference for IN+,Switch signal
J3 J1 5 GND Black Alarm GND
J2 reference for AIN (1/2/3)
J1
6 AIN1 Blue
Alarm input, for button/door contacts switch signal
Alarm In
7 AIN2 Brown detection,Please connect the Switch/button to
(Passive)
J4 AIN(1/2/3) and GND
8 AIN3 Gray
9 GND Black DC12V recommend, input voltage rang 9-15V,
Power Supply
10 +12V Red Current at least 1A @12V