NO. PROBLEM CAUSED BY REMARK
1 Production Delay Legalitation at Health Ministry is need very long time Printing Packaging delay
Import part ( cannula ) in Red Line when custom clearance 2 month
Machine also in Red Line when custom clearance 2 month
Registration for CE Marking & FDA need long time 6 -12 month
Too many internal procedure for validation ( too many protocolers ) 3 years
No technical support from mother company ( Nipro Japan ) Study on my own
Mistake in design Mold
2 High Rejection in automatic process Performance machine is bad ( rejection until 30% ) in test 8 hours
Performance machine is bad in high speed No Acceptance Test before machine delivery
Difficult to get new spare parts purchase
3 COGM and COGS is not actual Establishement Bill of Material only copy from Nipro Thailand but it is not Cost variance in inventory also in accounting process
COGM : Cost of Good Manufacturing update follow actual process
COGS : Cost of Good Sales
2 Extruder Intype 2