Introduction
The performance of protective coatings of paint and related products
applied to steel is significantly affected by the state of the steel surface
immediately prior to painting. The principal factors that are known to influ-
ence this performance are:
This is one of a number of parts of I S 0 8502 that specify tests for the as-
sessment of suiface cleanliness. In connection with such tests, there are
several methods for the extraction, for analysis, of soluble contaminants on
surfaces to be painted. Some of these methods are based on the swabbing
of comparatively large test surfaces. This technique provides average values of
the contamination present, but it may conceal localized concentrations of
IV
There are other methods, however, which use small cells for the liquid
used to remove and collect the surface contaminants. The cells (rigid or
flexible) are attached to test surfaces where soluble contaminants could
be expected, e.g. where pitting has occurred. This technique usually pro-
vides more accurate, point values of the contamination present.
This part of I S 0 8502 does not cover the subsequent An adhesive patch with a central compartment de-
analysis of the contaminants that have been dissolved signed to hold a solvent is attached to the surface
off. Methods of analysis suitable for field use are de- from which soluble contaminants are to be removed.
scribed in other parts of I S 0 8502. The solvent is injected into the compartment by
means of a syringe, and then sucked back into the
syringe. This operation is repeated a number of times.
The solvent (now containing contaminants dissolved
off the test surface) is then transferred to a suitable
2 Normative references vessel for analysis.
Table 1 - Standard patches 5.5 Inject the solvent, ensuring that it wets the
whole of the test surface (see figure 4).
Patch size Compartment area (mm2)
If necessary to avoid air remaining trapped in the
A-O155 155f 2 patch compartment, carry out the injection in two
A-O31 O 310f 3 steps as follows:
A-O625 625f 6
A-I 250 1250f13
A-2500 2 500 f 25 Inject half of the solvent. Evacuate the air through the
needle by reverse operation of the syringe. Remove
the needle from the patch. Holding the syringe with the
needle pointing upwards, expel the air. Re-insert the
4.2 Reusable syringe: needle into the compartment and inject the remainder
of the solvent.
max. cylinder volume: 8 ml
Max. needle diameter: 1 m m 5.6 After a suitable period of time, to be agreed be-
max. needle length: 50 m m tween the interested parties, suck the solvent back
into the syringe (see figure 5).
4.3 Solvent, chosen as a function of the surface
contaminants to be determined. For the determination NOTE 3 On unpitted blastcleaned areas, a period of 10 min
of water-soluble salts or other water-soluble contami- has been found satisfactory, as by then more than 90 % of
nants, use distilled or deionized water. the soluble salts have usually been dissolved.
4.4 Contact thermometer, accurate to 0,5"C and 5.7 Without removing the syringe needle from the
graduated at 0,5 O C intervals. patch, reinject the solvent into the compartment and
then suck the solvent back into the syringe cylinder.
Repeat until a t least four injection/sucking cycles have
been completed.
5.2 Press the adhesive side of the patch against the 5.9 During steps 5.3 to 5.8, it is essential that no
test surface (see figure 2) in such a way that the solvent be lost from the patch or syringe, due for
minimum amount of air is trapped in the compartment instance to inferior-quality materials or improper hand-
in the patch. ling of the materials. If any solvent is lost, the solution
obtained shall be rejected.
5.3 Fill the syringe (4.2) with solvent (4.3) (see
figure 3). 5.10 On completion of step 5.8, clean and rinse the
syringe so that it can be re-used. A bent needle is best
NOTE 2 The volume of solvent needed to fill the patch left as it is until it becomes necessary to straighten it
compartment is proportional to the compartment area, and or bend it further.
normally amounts to 2.6 x 1O4 mVmm2f 0.6 x I O 3 ml/mm2.
5.11 Record the temperature of the steel surface to
5.4 Insert the syringe needle a t an angle of about the nearest 0,5 O C using the contact thermometer
30" to the test surface near the outer edge of the (4.4).
2
COPYRIGHT International Organization for Standardization
Licensed by Information Handling Services
= 48539Q3 064400L T4b =
Q IS0 IS0 8502-6:1995(EI
3
COPYRIGHT International Organization for Standardization
Licensed by Information Handling Services
= 4851903 Ob44002 982
I S 0 8502-6:1995(E)
f-
4
COPYRIGHT International Organization for Standardization
Licensed by Information Handling Services
4853903 Ob44003 819 M
IS0 8502-6:1995(E)
Annex A
(normative)
A.3.5 Stopwatch.
Leakage of the solvent is more likely to occur when
the surface is unclean (e.g. covered by rust or moist-
ure) or when it is rough (e.g. due to pits remaining
after blast-cleaning).
A.4 Procedure
Leakage is also more likely to occur when the internal
pressure is high and of long duration. Perform the test in standard atmosphere 23/50 with
wide tolerances as defined in IS0 554.
These factors affecting leakage are intentionally exag- NOTE 6 The numerical values 23 and 50 refer to the tem-
gerated in the following leak test, which is intended perature in degrees Celsius and the relative humidity in
for type testing of adhesive patches having an elas- percent.
tomer film made of rubber.
A.4.1 Attach the adhesive patch (A.3.1) to the steel
NOTE 5 The test method may also be used for production plate (A.3.2) and use the syringe (A.3.3) to inject a vol-
testing, as well as checking deliveries of such patches. Fi- ume of water (A.3.4) as specified in table A.1.
nally, it may be used for comparisons and to predict poss-
ible difficulties in the contaminant-dissolution procedure
(clause 5). However, passing the test is no guarantee that a Table A.l
patch will function satisfactorily in practice under all circum-
stances. Patch size Volume of water injected (ml)
A-O1 55 0.8 f 0 , l
A-O3 1O 3.7 f 0 , l
A.2 Principle A-O625 5.5 f 0 , l
A-1 250 14,9 k 0 , l
A.3.2 Visually clean steel plate, of convenient size, A.4.5 If leakage does not occur within 20 min, the
e.g. 150 mm x 150 mm, originally of rust grade D, adhesive patch has passed the leak test.
5
COPYRIGHT International Organization for Standardization
Licensed by Information Handling Services
IS0 8502-6:1995E) 0 IS0
A.5 Test report c) the time required for leakage to occur, if less than
20 min;
The test report shall contain at least the following in-
formation: d) the point where leakage started;
a) the type of adhesive patch tested and its size; e) the date of the test.
6
COPYRIGHT International Organization for Standardization
Licensed by Information Handling Services
IS0 8502-6:1995(E) Q IS0
ICs 87.020
Descriptors: paints, varnishes, substrates, steel products, surface condition, tests, field tests, determination, impurities, soluble matter,
cleanliness checks.