You are on page 1of 2

7 Day Cured Compression Test of Concrete

Specimen 6 Inch Dia x 12 inches Height


sample 1
Date : 2020/10/16 File Name :
Operator : Arshad Ali, Iklaq Ahmed Control : Stroke
V1 : 0.1 in/min V2 : Off
V3 : Off

Shape: Rod
Diameter Height
Units in in
Cylinder 6 dia x 6.0000 12.0000
12 Height

Name YP_Force YP_Disp YP_Stress YP_Strain LASE1_Force


Parameter 0.1 %/FS 0.1 %/FS 0.1 %/FS 0.1 %/FS 3.937008E-02 in
Units lbf in lbf/in2 % lbf
Cylinder 6 dia x -.- -.- -.- -.- 6714.56
12 Height

Name LASE1_Stress Elastic YS1_Force YS1_Disp YS1_Stress


Parameter 3.937008E-02 in 2247.786, 0.2 % 0.2 % 0.2 %
4495.572 lbf
Units lbf/in2 lbf/in2 lbf in lbf/in2
Cylinder 6 dia x 237.479 93885.6 25097.9 0.15035 887.658
12 Height

Name YS1_Strain Max_Force Max_Disp Max_Stress Max_Strain


Parameter 0.2 %
Units % lbf in lbf/in2 %
Cylinder 6 dia x 1.25295 44226.9 0.11719 1564.21 0.97654
12 Height

Name Energy Break_Force Break_Disp Break_Stress Break_Strain


Units kip.in lbf in lbf/in2 %
Cylinder 6 dia x 4.30095 -.- -.- -.- -.-
12 Height

Name EASL1_Disp EASL1_Strain


Parameter 224.7786 lbf 224.7786 lbf
Units in %
Cylinder 6 dia x 0.00392 0.03265
12 Height
7 Day Compression Testing of Cyl
4000

3600

3200

2800
Stress(lbf/in2)

2400

2000

1600 Max
1200

800

400

0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.5
Stroke(in)

Comment