You are on page 1of 46

BRITISH STANDARD BS EN

60617-6:1996
IEC 617-6:
1996

Graphical symbols for


diagrams —
Part 6: Production and conversion of
electrical energy

The European Standard EN 60617-6:1996 has the status of a


British Standard

ICS 01.080.30; 29.020


BS EN 60617-6:1996

Committees responsible for this


British Standard

The preparation of this British Standard was entrusted to Technical


Committee GEL/3, Documentation and graphical symbols, upon which the
following bodies were represented:

British Photographic Association


Consumer Policy Committee of BSI
Federation of the Electronics Industry
GAMBICA (BEAMA Ltd.)
Transmission and Distribution Association (BEAMA Ltd.)

This British Standard, having


been prepared under the
direction of the Electrotechnical
Sector Board, was published
under the authority of the
Standards Board and comes
into effect on Amendments issued since publication
15 December 1996

© BSI 10-1998 Amd. No. Date Comments

The following BSI references


relate to the work on this
standard:
Committee reference GEL/3
Draft for comment 92/28836 DC

ISBN 0 580 26760 1


BS EN 60617-6:1996

Contents

Page
Committees responsible Inside front cover
National foreword ii
Foreword 2
Text of EN 60617-6:1996 3

© BSI 10-1998 i
BS EN 60617-6:1996

National foreword

This British Standard has been prepared by Technical Committee GEL/3. It is the
English language version of EN 60617-6:1996, Graphical symbols for diagrams
Part 6: Production and conversion of electrical energy published by the European
Committee for Electrotechnical Standardization (CENELEC). It is identical with
IEC 617-6:1996 published by the International Electrotechnical Commission
(IEC).
This British Standard replaces BS 3939-6:1985 which is withdrawn.
NOTE The French language version of the alphabetic index has not been included.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.

Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii,
the EN title page, pages 2 to 41 and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on
the inside front cover.

ii © BSI 10-1998
EUROPEAN STANDARD EN 60617-6
NORME EUROPÉENNE
June 1996
EUROPÄISCHE NORM

ICS 01.080.30

Descriptors: Electric conversion, production of electrical energy, electric diagram, electrical symbol

English version

Graphical symbols for diagrams


Part 6: Production and conversion of electrical energy
(IEC 617-6:1996)

Symboles graphiques pour schémas Graphische Symbole für Schaltpläne


Partie 6: Production, transformation et Teil 6: Schaltzeichen für die Erzeugung und
conversion de l’énergie électrique Umwandlung elektrischer Energie
(CEI 617-6:1996) (IEC 617-6:1996)

This European Standard was approved by CENELEC on 1996-03-05.


CENELEC members are bound to comply with the CEN/CENELEC Internal
Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any
CENELEC member.
This European Standard exists in three official versions (English, French,
German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria,
Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy,
Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and
United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B-1050 Brussels

© 1996 Copyright reserved to CENELEC members


Ref. No. EN 60617-6:1996 E
EN 60617-6:1996

Foreword Contents
The text of document 3A/384/FDIS, future edition 2 Page
of IEC 617-6, prepared by SC 3A, Graphical symbols Introduction 3
for diagrams, of IEC TC 3, Documentation and
Chapter I: Qualifying symbols for winding
graphical symbols, was submitted to the
interconnections
IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60617-6 on 1996-03-05. Section 1 Separate windings 4
The following dates were fixed: Section 2 Internally connected windings 5
– latest date by which the Chapter II: Machines
EN has to be implemented Section 3 Elements of machines 7
at national level by Section 4 Types of machines 8
publication of an identical Section 5 Examples of direct current machines 9
national standard or by
Section 6 Examples of alternating current
endorsement (dop) 1997-02-01
commutator machines 10
– latest date by which the Section 7 Examples of synchronous machines 11
national standards
Section 8 Examples of induction type
conflicting with the EN
(asynchronous) machines 13
have to be withdrawn (dow) 1997-02-01
Chapter III: Transformers and reactors
Section 9 General symbols for transformers
and reactors 16
Section 10 Examples of transformers with
separate windings 19
Section 11 Examples of auto-transformers 25
Section 12 Examples of induction regulators 26
Section 13 Examples of measuring
transformers and pulse transformers 27
Chapter IV: Power converters
Section 14 Block symbols for power converters 31
Chapter V: Primary and secondary cells and
batteries
Section 15 Primary and secondary cells 32
Chapter VI: Power generators
Section16 General symbol for non-rotary
power generators 33
Section 17 Heat sources 33
Section 18 Examples of power generators 34
Section 19 Closed-loop controllers 36
Annex A (informative) Older symbols 37
Annex B (informative) English
alphabetic index 38

2 © BSI 10-1998
EN 60617-6:1996

Introduction The symbols in this standard are laid out in such a


way that the distance between connecting lines is a
This part of IEC 617 forms an element of a series
multiple of a certain modulus. Modulus 2M has been
which deals with graphical symbols for diagrams.
chosen to provide enough space for the required
The series consists of the following parts: terminal designation. The symbols have been drawn
— Part 1: General information, general index. to a size convenient for comprehension, using
Cross-reference tables; consistently the same grid in the representation of
— Part 2: Symbol elements, qualifying symbols all symbols.
and other symbols having general application; All symbols are designed within a grid in a
— Part 3: Conductors and connecting devices; computer-aided draughting system. The grid which
was used has been reproduced in the background of
— Part 4: Basic passive components; the symbols.
— Part 5: Semiconductors and electron tubes; The older symbols which were included in
— Part 6: Production and conversion of electrical appendix A of the first edition of IEC 617-6 for a
energy; transitional period, are no longer part of this second
— Part 7: Switchgear, controlgear and protective edition, as they will definitely be withdrawn from
devices; use.
— Part 8: Measuring instruments, lamps and The indexes in Annex B and C include an alphabetic
signalling devices; list of symbol names and their corresponding
— Part 9: Telecommunications: Switching and number. The symbol names are based on the
peripheral equipment; description of the symbols of this part. A general
index including an alphabetic list of symbols of all
— Part 10: Telecommunications: Transmission; parts is given in IEC 617-1.
— Part 11: Architectural and topographical
installation plans and diagrams;
— Part 12: Binary logic elements;
— Part 13: Analogue elements.
The scope and the normative references for this
series are given in IEC 617-1.
Symbols have been designed in accordance with
requirements given in the future ISO 11714-11). The
module size M = 2,5 mm has been used. For better
readability smaller symbols in this standard have
been enlarged to double size and are
marked “200 %” in the symbol column. To save
space larger symbols have been reduced to half size
and are marked “50 %” in the symbol column. In
accordance with the future ISO 11714-1, clause 7,
symbol dimensions (for instance height) may be
modified in order to make space for a greater
number of terminals or for other layout
requirements. In all cases, whether the size is
enlarged or reduced, or dimensions modified, the
thickness of the original line should be maintained
without scaling.

1)
At present, at the stage of Draft International Standard (document 3/563/DIS).

© BSI 10-1998 3
4

EN 60617-6:1996
Chapitre I: Symboles distinctifs pour Chapter I: Qualifying symbols for winding
l’interconnexion des enroulements interconnections
Section 1 — Enroulements séparés Section 1 — Separate windings
No. Symbole Symbol Légende Description
06-01-01 Un enroulement One winding

1. II convient d’indiquer le nombre d’enroulements séparés: 1. The number of separate windings should be indicated:
— soit par le nombre de traits dessinés, — either by the number of strokes drawn,
— soit par un nombre inscrit à coté du symbole. — or by adding a figure to the symbol.

06-01-02 EXEMPLES: EXAMPLES:

Trois enroulements séparés Three separate windings

06-01-03 Six enroulements séparés Six separate windings

2. Le symbole 06-01-01 peut aussi être utilisé pour 2. Symbol 06-01-01 may also be used to represent
représenter des enroulements à phases séparées windings which can be externally connected in various
permettant, par des moyens extérieurs, différents modes de ways.
connexion.

06-01-04 EXEMPLES: EXAMPLES:

Enroulement triphasé, à phases séparées Three-phase winding, phases not interconnected

06-01-05 Enroulement polyphasé, à m phases séparées m-phase winding, phases not interconnected

06-01-06 Enroulement diphasé, quatre fils Two-phase winding, four-wire


© BSI 10-1998
© BSI 10-1998

Section 2 — Enroulements connectés Section 2 — Internally connected windings


intérieurement
2.1 Le mode de connexion des enroulements de transformateurs peut également 2.1 The method of connecting transformer windings may also be indicated by
être indiqué par des codes. Voir la CEI 76: Transformateurs de puissance. codes. See IEC Publication 76: Power Transformers.

No. Symbole Symbol Légende Description


06-02-01 Enroulement diphasé Two-phase winding

06-02-02 Enroulement triphasé partiel, en V (60º) Three-phase winding, V (60º)

06-02-03 Enroulement tétraphasé, avec neutre sorti Four-phase winding with neutral brought out

06-02-04 Enroulement triphasé, en T Three-phase winding, T

06-02-05 Enroulement triphasé, en triangle Three-phase winding, delta

Ce symbols peut aussi être utilisé pour représenter des This symbol may be used to symbolize a multiphase
enroulements multiphasés connectés en polygone, en polygon connection of windings by adding a figure to
précisant par un chiffre le nombre de phases. denote the number of phases.

06-02-06 Enroulement triphasé, en triangle ouvert Three-phase winding, open delta

06-02-07 Enroulement triphasé, en étoile Three-phase winding, star

EN 60617-6:1996
Ce symbole peut aussi être utilisé pour représenter des This symbol may be used to symbolize a multiphase star
enroulements multiphasés connectés en étoile, en précisant connection of windings by adding a figure to denote the
par un chiffre le nombre de phases. number of phases.

06-02-08 Enroulement triphasé, en étoile, avec neutre sorti Three-phase winding, star, with neutral brought out
5
6

EN 60617-6:1996
No. Symbole Symbol Légende Description
06-02-09 Enroulement triphasé, en zigzag Three-phase winding, zigzag or interconnected star

06-02-10 Enroulement hexaphasé, en double triangle Six-phase winding, double delta

06-02-11 Enroulement hexaphasé, en polygone Six-phase winding, polygon

06-02-12 Enroulement hexaphasé, en étoile Six-phase winding, star

06-02-13 Enroulement hexaphasé, en double zigzag, avec neutre sorti Six-phase winding, fork with neutral brought out
© BSI 10-1998
© BSI 10-1998

Chapitre II: Machines Chapter II: Machines


Section 3 — Éléments de machines Section 3 — Elements of machines

No. Symbole Symbol Légende Description


Distinction entre divers types d’enroulements ayant Differentiation between windings having different
différentes fonctions: functions:

06-03-01 Enroulement de commutation ou de compensation Commutating or compensating winding

06-03-02 Enroulement série Series winding

06-03-03 Enroulement d’excitation en dérivation ou séparé Shunt winding or separate winding

06-03-04 Balai (sur bague ou sur collecteur à lames) Brush (on slip-ring or commutator)

Les balais sont représentés seulement si cela est nécessaire. Brushes are shown only if necessary. For an example of
Comme exemple d’application, voir le symbole 06-05-03. application, see symbol 06-05-03.

EN 60617-6:1996
7
8

EN 60617-6:1996
Section 4 — Types de machines Section 4 — Types of machines

No. Symbole Symbol Légende Description


06-04-01 Machine, symbole général Machine, general symbol

L’astérisque, *, doit être remplacé par un des symboles littéraux The asterisk, *, shall be replaced by one of the
suivants: following letter designations:

C Commutatrice C Rotary converter


G Génératrice G Generator
GS Alternateur synchrone GS Synchronous generator
M Moteur M Motor
MG Machine pouvant servir comme génératrice ou MG Machine capable of use as a generator or
comme moteur motor
MS Moteur synchrone MS Synchronous motor
Les symboles 02-02-01 et 02-02-04 peuvent compléter le The symbols 02-02-01 and 02-02-04 may be added,
symbole comme indiqué dans les symboles des sections 5 à 8 as shown in Sections 5 to 8

Pour les générateurs de puissance non-rotatifs, voir section 16 For non-rotary power generators, see section 16

06-04-02 Moteur linéaire, symbole général Linear motor, general symbol

06-04-03 Moteur pas à pas, symbole général Stepping motor, general symbol

06-04-04 Générateur à commande manuelle (magnéto d’appel) Hand-generator (magneto caller)


© BSI 10-1998
© BSI 10-1998

Section 5 — Exemples de machines à Section 5 — Examples of direct current


courant continu machines

No. Symbole Symbol Légende Description


06-05-01 Moteur série, DC Series motor, DC

06-05-02 Moteur shunt (à excitation en dérivation), DC Shunt motor, DC

06-05-03 Génératrice DC à excitation composée à courte Generator, DC, compound excited (short shunt),
dérivation, représentée avec bomes et balais shown with terminals and brushes

06-05-04 Convertisseur rotatif, DC/DC avec excitation Rotary converter, DC/DC with common permanent
commune par aimant permanent magnet field

06-05-05 Convertisseur rotatif, DC/DC avec enroulement Rotary converter, DC/DC with common exitation

EN 60617-6:1996
d’excitation commun winding
9
10

EN 60617-6:1996
Section 6 — Exemples de machines à Section 6 — Examples of alternating current
courant alternatif à collecteur commutator machines

No. Symbole Symbol Légende Description


06-06-01 Moteur série, monophasé Series motor, single-phase

06-06-02 Moteur à répulsion, monophasé Repulsion motor, single-phase

06-06-03 Moteur série, triphasé Series motor, three-phase


© BSI 10-1998
© BSI 10-1998

Section 7 — Exemples de machines Section 7 — Examples of synchronous


synchrones machines

No. Symbole Symbol Légende Description


06-07-01 Alternateur synchrone à aimant permanent, triphasé Synchronous generator, three-phase with permanent magnet

06-07-02 Moteur synchrone monophasé Synchronous motor, single-phase

06-07-03 Alternateur synchrone, triphasé à induit monté en Synchronous generator, three-phase, star connected, neutral
étoile, neutre sorti brought out

06-07-04 Alternateur synchrone triphasé, à deux extrémités Synchronous generator, three-phase, both ends of each phase
sorties pour chaque enroulement de phase winding brought out

EN 60617-6:1996
11
12

EN 60617-6:1996
No. Symbole Symbol Légende Description
06-07-05 Commutatrice triphasée à excitation en dérivation Synchronous rotary converter, three-phase, shunt- excited
© BSI 10-1998
© BSI 10-1998

Section 8 — Exemples de machines à induction Section 8 — Examples of induction type


(Asynchrones) (Asynchronous) machines
8.1 II convient que le symbole général pour une machine (06-04-01) soit utilisé 8.1 The general symbol for a machine (06-04-01) should be used to represent an
pour représenter une machine asynchrone dont le rotor n’a pas de asynchronous machine, if no external connections to the rotor exist, for
connexions extérieures, par exemple pour un moteur à rotor en example in a squirrel cage motor. An inner circle, representing the rotor,
court-circuit. II convient de dessiner un cercle intérieur, représentant le should be shown in those cases where external connections to the rotor
rotor si celui-ci comporte des connexions extérieures, voir par exemple le exist, see for example symbol 06-08-03.
symbole 06-08-03.

No. Symbole Symbol Légende Description


06-08-01 Moteur asynchrone triphasé, à rotor en court-circuit Induction motor, three-phase, squirrel cage

06-08-02 Moteur asynchrone monophasé, à rotor en court-circuit, Induction motor, single-phase, squirrel-cage, ends of
enroulement de phase auxiliaire à extrémités sorties split-phase winding brought out

06-08-03 Moteur asynchrone triphasé à rotor à bagues Induction motor, three-phase, with wound rotor

EN 60617-6:1996
13
14

EN 60617-6:1996
No. Symbole Symbol Légende Description
06-08-04 Moteur asynchrone, triphasé, à stator monté en étoile, Induction motor, three-phase, star-connected, with
avec démarreur automatique incorporé built-in automatic starter

06-08-05 Moteur linéaire asynchrone triphasé à déplacement dans Linear induction motor, three-phase, movement only in
un seul sens one direction
© BSI 10-1998
© BSI 10-1998

Chapitre III: Transformateurs et inductances Chapter III: Transformers and reactors


1 Deux formes de symboles sont données pour un même type de transformateur: 1 Two forms of symbols are shown for the same type of transformer:
— En forme 1: Chaque enroulement est représenté par un cercle. Cette — Form 1 uses a circle to represent each winding. Its use is preferably
utilisation est de préférence limitée à la représentation unifilaire. Les restricted to single-line representation. Symbols for transformer cores are
symboles des noyaux de transformateurs ne sont pas utilisés dans cette not used with this form.
forme.
— En forme 2: Chaque enroulement est représenté par le symbole 04-03-01. — Form 2 uses symbol 04-03-01 to represent each winding. The number of
On peut différencier entre certains enroulements par le nombre de half-circles may be varied to differentiate between certain windings.
demi-cercles.
2 La note 2 du symboles 04-03-01 est applicable à la représentation du noyau 2 For the representation of transformer cores, see Note 2 with symbol 04-03-01.
d’un transformateur.
3 Dans les symboles de transformateurs de courant ou d’impulsion, des traits 3 In the case of symbols for current and pulse transformers, straight lines,
droits peuvent être utilisés pour représenter des enroulements primaires. Voir representing primary windings may be used with either form.
section 13. See Section 13.
4 La CEI 375 donne une méthode permettant d’indiquer la correspondance entre 4 IEC 375 gives a method of indicating the instantaneous voltage polarities of
les polarités instantanées des tensions de circuits électriques couplés. Comme coupled electric circuits. For an example of application, see symbol 06-09-03.
exemple d’application, voir symbole 06-09-03.

EN 60617-6:1996
15
16

EN 60617-6:1996
Section 9 — Symboles généraux pour Section 9 — General symbols for transformers
transformateurs et reactances and reactors

No. Symbole Symbol Légende Description

06-09-01 Forme 1 Transformateur à deux enroulements Transformer with two windings


Form 1

06-09-02 Forme 2 Les polarités instantanées des tensions peuvent être The instantaneous voltage polarities may be
Form 2 indiquées en forme 2 du symbole. indicated in form 2 of the symbol.

06-09-03 Forme 2 EXEMPLE: EXAMPLE:


Form 2
Transformateur à deux enroulements, figuré avec Transformer with two windings, shown with
indicateurs de polarité instantanée des tensions instantaneous voltage polarity indicators

Des courants instantanés entrant par les extrémités Instantaneous currents entering the marked ends of
des enroulements marqués d’un point produisent the windings produce aiding fluxes
des flux additifs
© BSI 10-1998
© BSI 10-1998

No. Symbole Symbol Légende Description

06-09-04 Forme 1 Transformateur à trois enroulements Transformer with three windings


Form 1

06-09-05 Forme 2
Form 2

06-09-06 Forme 1 Autotransformateur Auto-transformer


Form 1

06-09-07 Forme 2
Form 2

06-09-08 Forme 1 Inductance Choke


Form 1
Reactor

EN 60617-6:1996
06-09-09 Forme 2 Utiliser is symbole 04-03-01
Form 2 Use symbol 04-03-01
17
18

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-09-10 Forme 1 Transformateur de courant Current transformer


Form 1
Transformateur d’impulsion Pulse transformer

06-09-11 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

Section 10 — Exemples de transformateurs à Section 10 — Examples of transformers with


enroulements séparés separate windings

No. Symbole Symbol Légende Description

06-10-01 Forme 1 Transformateur monophasé à deux enroulements Single-phase transformer with two windings and
Form 1 avec écran screen

06-10-02 Forme 2
Form 2

06-10-03 Forme 1 Transformateur à prise médiane sur un Transformer with centre tapping on one winding
Form 1 enroulement

EN 60617-6:1996
06-10-04 Forme 2
Form 2
19
20

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-10-05 Forme 1 Transformateur à couplage réglable Transformer with variable coupling


Form 1

06-10-06 Forme 2
Form 2

06-10-07 Forme 1 Transformateur triphasé, couplage Three-phase transformer, connection star-delta


Form 1 étoile-triangle

06-10-08 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

No. Symbole Symbol Légende Description

06-10-09 Forme 1 Transformateur triphasé à quatre prises, couplage: Three-phase transformer with four tappings (taps),
Form 1 étoile-étoile connection; star-star
Chaque enroulement primaire est figuré avec quatre Each primary winding is shown with four available
sorties disponibles s’ajoutant à celles des extrémités connection points in addition to those at the
d’enroulement winding-ends

06-10-10 Forme 2
Form 2

06-10-11 Forme 1 Groupe de trois transformateurs monophasés, Three-phase bank of single-phase transformers,
Form 1 couplage étoile-triangle connection star-delta

EN 60617-6:1996
06-10-12 Forme 2
Form 2
21
22

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-10-13 Forme 1 Transformateur triphasé à prises multiples avec Three-phase transformer with on-load tap changer,
Form 1 commutateur de prises pour manœuvre en charge, connection star-delta
couplage étoile-triangle

06-10-14 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

No. Symbole Symbol Légende Description

06-10-15 Forme 1 Transformateur triphasé, couplage étoile-zigzag Three-phase transformer, connection star-zigzag
Form 1 avec neutre sorti with the neutral brought out

06-10-16 Forme 2
Form 2

EN 60617-6:1996
23
24

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-10-17 Forme 1 Transformateur triphasé, couplage Three-phase transformer, connection star-star-delta


Form 1 étoile-étoile-triangle

06-10-18 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

Section 11 — Exemples d’autotransformateurs Section 11— Examples of


auto-transformers

No. Symbole Symbol Légende Description

06-11-01 Forme 1 Autotransformateur, monophasé Auto-transformer, single-phase


Form 1

06-11-02 Forme 2
Form 2

06-11-03 Forme 1 Autotransformateur, triphasé, couplage étoile Auto-transformer, three-phase, connection star
Form 1

06-11-04 Forme 2

EN 60617-6:1996
Form 2
25
26

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-11-05 Forme 1 Autotransformateur, monophasé à réglage Auto-transformer, single-phase with voltage


Form 1 progressif de la tension regulation

06-11-06 Forme 2
Form 2

Section 12 — Exemples de régulateurs à Section 12 — Examples of induction regulators


induction

No. Symbole Symbol Légende Description

06-12-01 Forme 1 Régulateur à induction triphasé Three-phase induction regulator


Form 1

06-12-02 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

Section 13 — Exemples de transformateurs de Section 13 — Examples of measuring


mesure et de transformateurs d’impulsion transformers and pulse transformers
13.1 Pour les transformateurs de mesure ou transformateurs d’impulsion 13.1 For measuring transformers and pulse transformers use the appropriate
utiliser le symbole apprôprié de la section 9. symbol from section 9.

No. Symbole Symbol Légende Description

06-13-01A Forme 1 Transformateur de tension Voltage transformer


Form 1

06-13-01B Forme 2
Form 2

06-13-02 Forme 1 Transformateur de courant à deux noyaux avec un Current transformer with two cores with one
Form 1 enroulement secondaire sur chaque noyau. secondary winding on each core.

Les symboles des bornes dessinés à chaque The terminal symbols shown at each end of the
extrémité du circuit primaire indiquent qu’il s’agit primary circuit indicate that only a single device is
d’un appareil unique. Les symboles de bornes represented. The terminal symbols may be omitted
peuvent être omis si la désignation de l’appareil est if terminal designations are used.
indiquée.

Dans la forme 2, les symboles des circuits In form 2, core symbols may be omitted.
magnétiques peuvent être omis.

06-13-03 Forme 2
Form 2

EN 60617-6:1996
27
28

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-13-04 Forme 1 Transformateur de courant à deux enroulements Current transformer with two secondary windings
Form 1 secondaires sur un circuit magnétique commun on one core

Dans la forme 2, le circuit magnétique doit être In form 2, the core symbol shall be drawn.
tracé.

06-13-05 Forme 2
Form 2

06-13-06 Forme 1 Transformateur de courant à un enroulement Current transformer with one secondary winding
Form 1 secondaire avec une prise with one tapping

06-13-07 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

No. Symbole Symbol Légende Description

06-13-08 Forme 1 Transformateur de courant avec cinq passages d’un Current transformer with five passages of a
Form 1 conducteur servant comme bobine primaire conductor acting as a primary winding
Cette sorte de transformateur n’a pas de bobine This kind of current transformer has no built-in
primaire incorporée. primary winding.

06-13-09 Forme 2
Form 2

06-13-10 Forme 1 Transformateur d’impulsion ou de courant avec Pulse or current transformer with three threaded
Form 1 trois conducteurs primaires traversants primary conductors

06-13-11 Forme 2
Form 2

EN 60617-6:1996
29
30

EN 60617-6:1996
No. Symbole Symbol Légende Description

06-13-12 Forme 1 Transformateur d’impulsion ou de courant avec Pulse or current transformer with two secondary
Form 1 deux enroulements secondaires sur le même noyau windings on the same core and nine threaded
et neuf conducteurs primaires traversants primary conductors

06-13-13 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998

Chapitre IV: Convertisseurs de puissance Chapter IV: Power converters


Section 14 — Symboles fonctionnels pour Section 14 — Block symbols for power converters
convertisseurs de puissance

No. Symbole Symbol Légende Description

06-14-01 Convertisseur, symbole général Converter, general symbol

06-14-02 Convertisseur DC/DC DC/DC converter

06-14-03 Redresseur Rectifier

06-14-04 Redresseur en couplage à double voie (en pont) Rectifier in full wave (bridge) connection

06-14-05 Onduleur Inverter

06-14-06 Redresseur/onduleur Rectifier/inverter

EN 60617-6:1996
31
32

EN 60617-6:1996
Chapitre V: Piles et accumulateurs Chapter V: Primary and secondary cells and
batteries
Section 15 — Piles et accumulateurs Section 15 — Primary and secondary cells

No. Symbole Symbol Légende Description

06-15-01 Elément de pile Primary cell


Elément d’accumulateur Secondary cell
Batterie pile ou d’accumulateurs Battery of primary or secondary cells

Le trait long représente le pôle positif, le trait court The longer line represents the positive pole, the shorter
représente le pôle négatif one the negative pole

06-15-02 supprimé Transferé à l’annexe A: 06-A1-01 Transferred to annex A: 06-A1-01


deleted

06-15-03 supprimé Transferé à l’annexe A: 06-A1-02 Transferred to annex A: 06-A1-02


deleted
© BSI 10-1998
© BSI 10-1998

Chapitre VI: Générateurs de puissance Chapter VI: Power generators


Section 16 — Symbole général de generateurs Section 16 — General symbol for non-rotary
non-rotatifs de puissance power generators

No. Symbole Symbol Légende Description

06-16-01 Générateur, symbole général Generator, general symbol

Pour un générateur rotatif, utiliser le For a rotary generator, use symbol 06-04-01.
symbole 06-04-01.

Section 17 — Sources de chaleur Section 17 — Heat sources

No. Symbole Symbol Légende Description

06-17-01 Source de chaleur, symbole général Heat source, general symbol

06-17-02 Source de chaleur radioisotopique Radio-isotope heat source

06-17-03 Source de chaleur par combustion Combustion heat source

EN 60617-6:1996
33
34

EN 60617-6:1996
Section 18 — Exemples de générateurs de Section 18 — Examples of power generators
puissance

No. Symbole Symbol Légende Description

06-18-01 Générateur thermoélectrique à source de chaleur Thermoelectric generator, with combustion heat
par combustion source

06-18-02 Générateur thermoélectrique à source de chaleur Thermoelectric generator with non-ionizing


par rayonnement non ionisant radiation heat source

06-18-03 Générateur thermoélectrique à source de chaleur Thermoelectric generator with radio-isotope heat
radioisotopique source

06-18-04 Générateur thermoionique à semiconducteur à Thermionic diode generator with non-ionizing


source de chaleur par rayonnement non ionisant radiation heat source
© BSI 10-1998
© BSI 10-1998

No. Symbole Symbol Légende Description

06-18-05 Générateur thermoionique à semiconducteur à Thermionic diode generator with radio-isotope heat
source de chaleur radioisotopique source

06-18-06 Générateur photovoltaïque Photovoltaic generator

EN 60617-6:1996
35
36

EN 60617-6:1996
Section 19 — Régulateurs en boucle fermée Section 19 — Closed-loop controllers

No. Symbole Symbol Légende Description

06-19-01 Régulateur en boucle fermée Closed-loop controller

L’astérisque doit, soit être remplacé par un symbol The asterisk shall either be replaced by letter(s) or a
littéral ou graphique indiquant le comportement de graph denoting the transition behavior, or be
transition, soit être omis. omitted.
Pour présenter un régulateur en boucle ouverte le To indicate an open-loop controller the symbol shall
symbole doit être utilisé avec une entrée seulement. be used with only one input.

EXEMPLE: EXAMPLE:
© BSI 10-1998
© BSI 10-1998

Annexe A (informative) Anciens symboles Annex A (informative) Older symbols


Cette annexe contient une sélection de symboles normalisés dans la This annex contains symbols standardized in IEC 617-6 (1983), which are now
CEI 617-6 (1983) qui sont maintenant supprimés. Ces symboles figurent ici deleted. They are shown here for information purposes only to facilitate the
seulement afin de faciliter la compréhension des schémas anciens. comprehension of older diagrams.

(Dans cette annexe, les numéros de la publication de 1983 sont mis entre (In this annex the numbering from 1983-edition is quoted in parentheses.)
parenthèses.)

A1 — Piles et accumulateurs A1 — Primary and secondary cells and batteries

No. Symbole Symbol Légende Description

06-A1-01 Forme 1 Pile ou batterie d’accumulateurs Battery of primary or secunday cells


Form 1

(06-15-02)

06-A1-02 Forme 2
Form 2

(06-15-03)

EN 60617-6:1996
37
Annex B (informative)
38

EN 60617-6:1996
English alphabetic index

AC series motor 06-06-01 Element of, commutating winding 06-03-01


Auto-transformer 06-09-06 Element of, compensating winding 06-03-01
Auto-transformer, single-phase 06-11-01 Element of, separate winding 06-03-03
Auto-transformer, single-phase with voltage regulation 06-11-05 Element of, series winding 06-03-02
Auto-transformer, three-phase, connection star 06-11-03 Element of, shunt winding 06-03-03
Battery of primary or secondary cells 06-15-01 Four-phase winding with neutral brought out 06-02-03
Brush (on slip-ring or commutator) 06-03-04 Generator 06-04-01
Cell, primary 06-15-01 Generator, DC 06-05-03
Cell, secondary 06-15-01 Generator, general symbol 06-16-01
Choke 06-09-08 Generator, hand 06-04-04
Closed-loop controller 06-19-01 Generator, magneto caller 06-04-04
Combustion heat source 06-17-03 Generator, power, photovoltaic 06-18-06
Commutating winding, element of 06-03-01 Generator, power, thermionic diode with
Compensating winding, element of 06-03-01 non-ionizing radiation heat source 06-18-04
Controller, closed-loop 06-19-01 Generator, power, thermionic diode with
Converter 06-14-01 radio-isotope heat source 06-18-05
Converter, DC/DC 06-14-02 Generator, power, thermoelectric, with
Converter, rotary, DC/DC with common combustion heat source 06-18-01
exitation winding 06-05-05 Generator, power, thermoelectric, with non-ionizing
Converter, rotary, DC/DC with common radiation heat source 06-18-02
permanent magnet field 06-05-04 Generator, power, thermoelectric, with
Current transformer 06-09-10 radio-isotope heat source 06-18-03
Current transformer with two secondary windings on Generator, synchronous, three-phase, both ends
the same core and nine threaded primary conductors 06-13-12 of each phase winding brought out 06-07-04
Current transformer with five passages of a Generator, synchronous, three-phase, star
conductor acting as a primary winding 06-13-08 connected, neutral brought out 06-07-03
Current transformer with one secondary winding Generator, three-phase, permanent magnet 06-07-01
with one tapping 06-13-06 Hand-generator 06-04-04
Current transformer with three threaded primary Heat source 06-17-01
conductors 06-13-10 Heat source, combustion 06-17-03
Current transformer with two cores with one Induction motor, single-phase, squirrel-cage,
secondary winding on each core 06-13-02 ends of split-phase brought out 06-08-02
Current transformer with two secondary windings Induction motor, three-phase, squirrel cage 06-08-01
on one core 06-13-04 Induction motor, three-phase, star-connected,
DC series motor 06-05-01 with built-in automatic starter 06-08-04
DC, generator 06-05-03 Induction motor, three-phase, with wound rotor 06-08-03
© BSI 10-1998

DC/DC converter 06-14-02 lnduction regulator, three-phase 06-12-01


DC/DC Converter, rotary 06-05-04 lnverter 06-14-05
Delta, three-phase winding 06-02-05
Linear induction motor, three-phase, movement Rectifier in full wave (bridge) connection 06-14-04
© BSI 10-1998

only in one direction 06-08-05 Rectifier/inverter 06-14-06


Linear motor 06-04-02 Regulator, three-phase, induction 06-12-01
m-phase winding, phases not interconnected 06-01-05 Repulsion motor, single-phase 06-06-02
Machine 06-04-01 Rotary converter 06-04-01
Machine, element, brush 06-03-04 Rotary converter, DC/DC with common exitation winding 06-05-05
Machine, hand-generator 06-04-04 Rotary converter, DC/DC with common permanent
Machine, linear motor 06-04-02 magnet field 06-05-04
Machine, magneto caller 06-04-04 Rotary converter, synchronous, three-phase,
Machine, stepping motor 06-04-03 shunt-excited 06-08-00
Magneto caller 06-05-00 Secondary cell 06-15-01
Motor 06-04-01 Separate winding, element of 06-03-03
Motor, AC, repulsion, single-phase 06-06-02 Series motor, DC 06-05-01
Motor, AC, series, single-phase 06-06-01 Series motor, single-phase 06-06-01
Motor, AC, series, three-phase 06-06-03 Series motor, three-phase 06-06-03
Motor, DC, series 06-05-01 Series winding, element of 06-03-02
Motor, DC, shunt 06-05-02 Shunt motor, DC 06-05-02
Motor, induction, linear, three-phase, movement Shunt winding, element of 06-03-03
only in one direction 06-08-05 Single-phase transformer with two windings and screen 06-10-01
Motor, induction, single-phase, squirrel-cage, Six separate windings 06-01-03
ends of split-phase brought out 06-08-02 Six-phase winding, double delta 06-02-10
Motor, induction, three-phase, squirrel cage 06-08-01 Six-phase winding, fork with neutral brought out 06-02-13
Motor, induction, three-phase, star-connected, Six-phase winding, polygon 06-02-11
with built-in automatic starter 06-08-04 Six-phase winding, star 06-02-12
Motor, induction, three-phase, with wound rotor 06-08-03 Star, three-phase winding 06-02-07
Motor, linear 06-04-02 Star-zigzag, transformer, three-phase, connection 06-10-15
Motor, stepping 06-04-03 Stepping motor 06-04-03
Motor, synchronous, single-phase 06-07-02 Synchronous generator 06-04-01
Open delta, three-phase winding 06-02-06 Synchronous generator, three-phase, both ends of each
Photovoltaic generator 06-18-06 phase winding brought out 06-07-04
Power converter 06-14-00 Synchronous generator, three-phase, permanent magnet 06-07-00
Power converter, DC/DC 06-14-02 Synchronous generator, three-phase, star connected,
Power converter, inverter 06-14-05 neutral brought out 06-07-03
Power converter, rectifier 06-14-03 Synchronous machine, synchronous generator,
Power converter, rectifier in full wave (bridge) connection 06-14-04 three-phase, permanent magnet 06-07-01
Power converter, rectifier/inverter 06-14-06 Synchronous machine, synchronous motor,

EN 60617-6:1996
Primary cell 06-15-01 single-phase 06-07-02
Pulse transformer 06-09-10 Synchronous motor 06-04-01
Pulse transformer with three threaded primary Synchronous motor, single-phase 06-07-02
conductors 06-13-10 Synchronous rotary converter, three-phase,
Pulse transformer with two secondary windings on the shunt-excited 06-07-05
same core and nine threaded primary conductors 06-13-12 Thermionic diode generator with non-ionizing
Reactor 06-09-08 radiation heat source 06-18-04
Rectifier 06-14-03
39
Thermionic diode generator with radio-isotope Transformer, measuring current, with three threaded
40

EN 60617-6:1996
heat source 06-18-05 primary conductors 06-13-10
Thermoelectric generator with combustion Transformer, measuring current, with two secondary
heat source 06-18-00 windings on the same core and nine threaded
Thermoelectric generator with non-ionizing primary conductors 06-13-12
radiation heat source 06-18-02 Transformer, measuring pulse, with three threaded
Thermoelectric generator with radio-isotope primary conductors 06-13-10
heat source 06-18-03 Transformer, measuring pulse, with two secondary
Three seperate windings 06-01-02 windings on the same core and nine threaded
Three-phase bank of single-phase transformers, primary conductors 06-13-12
connection star-delta 06-10-11 Transformer, measuring voltage 06-13-01A
Three-phase induction regulator 06-12-01 Transformer, pulse 06-09-10
Three-phase transformer with four tappings(taps) 06-10-09 Transformer, single-phase, with two windings and
Three-phase transformer with on-load tap changer 06-10-13 screen 06-10-01
Three-phase transformer, connection star-delta 06-10-07 Transformer, three-phase bank of single-phase
Three-phase transformer, connection star-star-delta 06-10-17 transformers, connection star-delta 06-10-11
Three-phase transformer, connection star-zigzag 06-10-15 Transformer, three-phase, connection star-delta 06-10-07
Three-phase winding, delta 06-02-05 Transformer, three-phase, connection star-star-delta 06-10-17
Three-phase winding, interconnected star 06-02-07 Transformer, three-phase, connection star-zigzag 06-10-15
Three-phase winding, open delta 06-02-06 Transformer, three-phase, with four tappings(taps) 06-10-09
Three-phase winding, phases not interconnected 06-01-04 Transformer, three-phase, with on-load tap changer 06-10-13
Three-phase winding, star, with neutral brought out 06-02-08 Transformer, voltage 06-13-01A
Three-phase winding, T 06-02-04 Two-phase winding 06-02-01
Three-phase winding, V (60°) 06-02-02 Two-phase winding, four-wire 06-01-06
Three-phase winding, zigzag 06-02-09 Voltage transformer 06-13-01A
Transformer choke 06-09-08 Winding for machines, commutating 06-03-01
Transformer reactor 06-09-08 Winding for machines, compensating 06-03-01
Transformer with centre tapping on one winding 06-10-03 Winding for machines, separate 06-03-03
Transformer with three windings 06-09-04 Winding for machines, series 06-03-02
Transformer with two windings 06-09-01 Winding for machines, shunt 06-03-03
Transformer with two windings, shown with voltage Winding, internally connected, four-phase, with
polarity indicators 06-09-03 neutral brought out 06-02-03
Transformer with variable coupling 06-10-05 Winding, internally connected, six-phase,
Transformer, current 06-09-10 double delta 06-02-10
Transformer, measuring current, with two cores with Winding, internally connected, six-phase, fork with
one secondary winding on each core 06-13-02 neutral brought out 06-02-13
Transformer, measuring current, with two secondary Winding, internally connected, six-phase, polygon 06-02-11
windings on one core 06-13-04 Winding, internally connected, six-phase, star 06-02-12
Transformer, measuring current, with five passages of Winding, internally connected, three-phase V (60°) 06-02-02
a conductor acting as a primary winding 06-13-08 Winding, internally connected, three-phase, delta 06-02-05
© BSI 10-1998

Transformer, measuring current, with one secondary Winding, internally connected, three-phase, star 06-02-07
winding with one tapping 06-13-06 Winding, internally connected, three-phase, T 06-02-04
Winding, internally connected, three-phase, zigzag 06-02-09
Winding, internally connected, two-phase 06-02-00
© BSI 10-1998

Winding, one 06-01-01


Winding, seperate, m-phase winding, phases not
interconnected 06-01-05
Winding, seperate, one winding 06-01-01
Winding, seperate, six separate windings 06-01-03
Winding, seperate, three seperate windings 06-01-02
Winding, seperate, three-phase winding, phases not
interconnected 06-01-04
Zigzag, three-phase winding 06-02-09

EN 60617-6:1996
41
|
|
|
|
|
|
|
|
|
BSI Ð British Standards Institution
|
|
|
|
|
|
| BSI is the independent national body responsible for preparing British Standards. It
|
| presents the UK view on standards in Europe and at the international level. It is
| incorporated by Royal Charter.
|
|
| Revisions
|
|
| British Standards are updated by amendment or revision. Users of British Standards
|
| should make sure that they possess the latest amendments or editions.
|
|
| It is the constant aim of BSI to improve the quality of our products and services. We
|
| would be grateful if anyone finding an inaccuracy or ambiguity while using this
| British Standard would inform the Secretary of the technical committee responsible,
|
| the identity of which can be found on the inside front cover. Tel: 020 8996 9000.
|
| Fax: 020 8996 7400.
|
|
| BSI offers members an individual updating service called PLUS which ensures that
|
| subscribers automatically receive the latest editions of standards.
|
|
| Buying standards
|
| Orders for all BSI, international and foreign standards publications should be
|
| addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
|
|
| In response to orders for international standards, it is BSI policy to supply the BSI
|
| implementation of those that have been published as British Standards, unless
|
| otherwise requested.
|
|
| Information on standards
|
| BSI provides a wide range of information on national, European and international
|
| standards through its Library and its Technical Help to Exporters Service. Various
|
| BSI electronic information services are also available which give details on all its
|
| products and services. Contact the Information Centre. Tel: 020 8996 7111.
|
| Fax: 020 8996 7048.
|
|
| Subscribing members of BSI are kept up to date with standards developments and
| receive substantial discounts on the purchase price of standards. For details of
|
| these and other benefits contact Membership Administration. Tel: 020 8996 7002.
|
| Fax: 020 8996 7001.
|
|
| Copyright
|
|
| Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of
|
| the publications of the international standardization bodies. Except as permitted
| under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,
|
| stored in a retrieval system or transmitted in any form or by any means ± electronic,
|
| photocopying, recording or otherwise ± without prior written permission from BSI.
|
|
| This does not preclude the free use, in the course of implementing the standard, of
|
| necessary details such as symbols, and size, type or grade designations. If these
|
| details are to be used for any other purpose than implementation then the prior
| written permission of BSI must be obtained.
|
|
| If permission is granted, the terms may include royalty payments or a licensing
|
| agreement. Details and advice can be obtained from the Copyright Manager.
|
| Tel: 020 8996 7070.
|
|
|
|
|
|
|
|
|
BSI |
|
389 Chiswick High Road |
|
London |
|
W4 4AL |
|
|
|
|
|
|

You might also like