Professional Documents
Culture Documents
60617-6:1996
IEC 617-6:
1996
Contents
Page
Committees responsible Inside front cover
National foreword ii
Foreword 2
Text of EN 60617-6:1996 3
© BSI 10-1998 i
BS EN 60617-6:1996
National foreword
This British Standard has been prepared by Technical Committee GEL/3. It is the
English language version of EN 60617-6:1996, Graphical symbols for diagrams
Part 6: Production and conversion of electrical energy published by the European
Committee for Electrotechnical Standardization (CENELEC). It is identical with
IEC 617-6:1996 published by the International Electrotechnical Commission
(IEC).
This British Standard replaces BS 3939-6:1985 which is withdrawn.
NOTE The French language version of the alphabetic index has not been included.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii,
the EN title page, pages 2 to 41 and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on
the inside front cover.
ii © BSI 10-1998
EUROPEAN STANDARD EN 60617-6
NORME EUROPÉENNE
June 1996
EUROPÄISCHE NORM
ICS 01.080.30
Descriptors: Electric conversion, production of electrical energy, electric diagram, electrical symbol
English version
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Foreword Contents
The text of document 3A/384/FDIS, future edition 2 Page
of IEC 617-6, prepared by SC 3A, Graphical symbols Introduction 3
for diagrams, of IEC TC 3, Documentation and
Chapter I: Qualifying symbols for winding
graphical symbols, was submitted to the
interconnections
IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60617-6 on 1996-03-05. Section 1 Separate windings 4
The following dates were fixed: Section 2 Internally connected windings 5
– latest date by which the Chapter II: Machines
EN has to be implemented Section 3 Elements of machines 7
at national level by Section 4 Types of machines 8
publication of an identical Section 5 Examples of direct current machines 9
national standard or by
Section 6 Examples of alternating current
endorsement (dop) 1997-02-01
commutator machines 10
– latest date by which the Section 7 Examples of synchronous machines 11
national standards
Section 8 Examples of induction type
conflicting with the EN
(asynchronous) machines 13
have to be withdrawn (dow) 1997-02-01
Chapter III: Transformers and reactors
Section 9 General symbols for transformers
and reactors 16
Section 10 Examples of transformers with
separate windings 19
Section 11 Examples of auto-transformers 25
Section 12 Examples of induction regulators 26
Section 13 Examples of measuring
transformers and pulse transformers 27
Chapter IV: Power converters
Section 14 Block symbols for power converters 31
Chapter V: Primary and secondary cells and
batteries
Section 15 Primary and secondary cells 32
Chapter VI: Power generators
Section16 General symbol for non-rotary
power generators 33
Section 17 Heat sources 33
Section 18 Examples of power generators 34
Section 19 Closed-loop controllers 36
Annex A (informative) Older symbols 37
Annex B (informative) English
alphabetic index 38
2 © BSI 10-1998
EN 60617-6:1996
1)
At present, at the stage of Draft International Standard (document 3/563/DIS).
© BSI 10-1998 3
4
EN 60617-6:1996
Chapitre I: Symboles distinctifs pour Chapter I: Qualifying symbols for winding
l’interconnexion des enroulements interconnections
Section 1 — Enroulements séparés Section 1 — Separate windings
No. Symbole Symbol Légende Description
06-01-01 Un enroulement One winding
1. II convient d’indiquer le nombre d’enroulements séparés: 1. The number of separate windings should be indicated:
— soit par le nombre de traits dessinés, — either by the number of strokes drawn,
— soit par un nombre inscrit à coté du symbole. — or by adding a figure to the symbol.
2. Le symbole 06-01-01 peut aussi être utilisé pour 2. Symbol 06-01-01 may also be used to represent
représenter des enroulements à phases séparées windings which can be externally connected in various
permettant, par des moyens extérieurs, différents modes de ways.
connexion.
06-01-05 Enroulement polyphasé, à m phases séparées m-phase winding, phases not interconnected
06-02-03 Enroulement tétraphasé, avec neutre sorti Four-phase winding with neutral brought out
Ce symbols peut aussi être utilisé pour représenter des This symbol may be used to symbolize a multiphase
enroulements multiphasés connectés en polygone, en polygon connection of windings by adding a figure to
précisant par un chiffre le nombre de phases. denote the number of phases.
EN 60617-6:1996
Ce symbole peut aussi être utilisé pour représenter des This symbol may be used to symbolize a multiphase star
enroulements multiphasés connectés en étoile, en précisant connection of windings by adding a figure to denote the
par un chiffre le nombre de phases. number of phases.
06-02-08 Enroulement triphasé, en étoile, avec neutre sorti Three-phase winding, star, with neutral brought out
5
6
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-02-09 Enroulement triphasé, en zigzag Three-phase winding, zigzag or interconnected star
06-02-13 Enroulement hexaphasé, en double zigzag, avec neutre sorti Six-phase winding, fork with neutral brought out
© BSI 10-1998
© BSI 10-1998
06-03-04 Balai (sur bague ou sur collecteur à lames) Brush (on slip-ring or commutator)
Les balais sont représentés seulement si cela est nécessaire. Brushes are shown only if necessary. For an example of
Comme exemple d’application, voir le symbole 06-05-03. application, see symbol 06-05-03.
EN 60617-6:1996
7
8
EN 60617-6:1996
Section 4 — Types de machines Section 4 — Types of machines
L’astérisque, *, doit être remplacé par un des symboles littéraux The asterisk, *, shall be replaced by one of the
suivants: following letter designations:
Pour les générateurs de puissance non-rotatifs, voir section 16 For non-rotary power generators, see section 16
06-04-03 Moteur pas à pas, symbole général Stepping motor, general symbol
06-05-03 Génératrice DC à excitation composée à courte Generator, DC, compound excited (short shunt),
dérivation, représentée avec bomes et balais shown with terminals and brushes
06-05-04 Convertisseur rotatif, DC/DC avec excitation Rotary converter, DC/DC with common permanent
commune par aimant permanent magnet field
06-05-05 Convertisseur rotatif, DC/DC avec enroulement Rotary converter, DC/DC with common exitation
EN 60617-6:1996
d’excitation commun winding
9
10
EN 60617-6:1996
Section 6 — Exemples de machines à Section 6 — Examples of alternating current
courant alternatif à collecteur commutator machines
06-07-03 Alternateur synchrone, triphasé à induit monté en Synchronous generator, three-phase, star connected, neutral
étoile, neutre sorti brought out
06-07-04 Alternateur synchrone triphasé, à deux extrémités Synchronous generator, three-phase, both ends of each phase
sorties pour chaque enroulement de phase winding brought out
EN 60617-6:1996
11
12
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-07-05 Commutatrice triphasée à excitation en dérivation Synchronous rotary converter, three-phase, shunt- excited
© BSI 10-1998
© BSI 10-1998
06-08-02 Moteur asynchrone monophasé, à rotor en court-circuit, Induction motor, single-phase, squirrel-cage, ends of
enroulement de phase auxiliaire à extrémités sorties split-phase winding brought out
06-08-03 Moteur asynchrone triphasé à rotor à bagues Induction motor, three-phase, with wound rotor
EN 60617-6:1996
13
14
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-08-04 Moteur asynchrone, triphasé, à stator monté en étoile, Induction motor, three-phase, star-connected, with
avec démarreur automatique incorporé built-in automatic starter
06-08-05 Moteur linéaire asynchrone triphasé à déplacement dans Linear induction motor, three-phase, movement only in
un seul sens one direction
© BSI 10-1998
© BSI 10-1998
EN 60617-6:1996
15
16
EN 60617-6:1996
Section 9 — Symboles généraux pour Section 9 — General symbols for transformers
transformateurs et reactances and reactors
06-09-02 Forme 2 Les polarités instantanées des tensions peuvent être The instantaneous voltage polarities may be
Form 2 indiquées en forme 2 du symbole. indicated in form 2 of the symbol.
Des courants instantanés entrant par les extrémités Instantaneous currents entering the marked ends of
des enroulements marqués d’un point produisent the windings produce aiding fluxes
des flux additifs
© BSI 10-1998
© BSI 10-1998
06-09-05 Forme 2
Form 2
06-09-07 Forme 2
Form 2
EN 60617-6:1996
06-09-09 Forme 2 Utiliser is symbole 04-03-01
Form 2 Use symbol 04-03-01
17
18
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-09-11 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-10-01 Forme 1 Transformateur monophasé à deux enroulements Single-phase transformer with two windings and
Form 1 avec écran screen
06-10-02 Forme 2
Form 2
06-10-03 Forme 1 Transformateur à prise médiane sur un Transformer with centre tapping on one winding
Form 1 enroulement
EN 60617-6:1996
06-10-04 Forme 2
Form 2
19
20
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-10-06 Forme 2
Form 2
06-10-08 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-10-09 Forme 1 Transformateur triphasé à quatre prises, couplage: Three-phase transformer with four tappings (taps),
Form 1 étoile-étoile connection; star-star
Chaque enroulement primaire est figuré avec quatre Each primary winding is shown with four available
sorties disponibles s’ajoutant à celles des extrémités connection points in addition to those at the
d’enroulement winding-ends
06-10-10 Forme 2
Form 2
06-10-11 Forme 1 Groupe de trois transformateurs monophasés, Three-phase bank of single-phase transformers,
Form 1 couplage étoile-triangle connection star-delta
EN 60617-6:1996
06-10-12 Forme 2
Form 2
21
22
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-10-13 Forme 1 Transformateur triphasé à prises multiples avec Three-phase transformer with on-load tap changer,
Form 1 commutateur de prises pour manœuvre en charge, connection star-delta
couplage étoile-triangle
06-10-14 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-10-15 Forme 1 Transformateur triphasé, couplage étoile-zigzag Three-phase transformer, connection star-zigzag
Form 1 avec neutre sorti with the neutral brought out
06-10-16 Forme 2
Form 2
EN 60617-6:1996
23
24
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-10-18 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-11-02 Forme 2
Form 2
06-11-03 Forme 1 Autotransformateur, triphasé, couplage étoile Auto-transformer, three-phase, connection star
Form 1
06-11-04 Forme 2
EN 60617-6:1996
Form 2
25
26
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-11-06 Forme 2
Form 2
06-12-02 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-13-01B Forme 2
Form 2
06-13-02 Forme 1 Transformateur de courant à deux noyaux avec un Current transformer with two cores with one
Form 1 enroulement secondaire sur chaque noyau. secondary winding on each core.
Les symboles des bornes dessinés à chaque The terminal symbols shown at each end of the
extrémité du circuit primaire indiquent qu’il s’agit primary circuit indicate that only a single device is
d’un appareil unique. Les symboles de bornes represented. The terminal symbols may be omitted
peuvent être omis si la désignation de l’appareil est if terminal designations are used.
indiquée.
Dans la forme 2, les symboles des circuits In form 2, core symbols may be omitted.
magnétiques peuvent être omis.
06-13-03 Forme 2
Form 2
EN 60617-6:1996
27
28
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-13-04 Forme 1 Transformateur de courant à deux enroulements Current transformer with two secondary windings
Form 1 secondaires sur un circuit magnétique commun on one core
Dans la forme 2, le circuit magnétique doit être In form 2, the core symbol shall be drawn.
tracé.
06-13-05 Forme 2
Form 2
06-13-06 Forme 1 Transformateur de courant à un enroulement Current transformer with one secondary winding
Form 1 secondaire avec une prise with one tapping
06-13-07 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-13-08 Forme 1 Transformateur de courant avec cinq passages d’un Current transformer with five passages of a
Form 1 conducteur servant comme bobine primaire conductor acting as a primary winding
Cette sorte de transformateur n’a pas de bobine This kind of current transformer has no built-in
primaire incorporée. primary winding.
06-13-09 Forme 2
Form 2
06-13-10 Forme 1 Transformateur d’impulsion ou de courant avec Pulse or current transformer with three threaded
Form 1 trois conducteurs primaires traversants primary conductors
06-13-11 Forme 2
Form 2
EN 60617-6:1996
29
30
EN 60617-6:1996
No. Symbole Symbol Légende Description
06-13-12 Forme 1 Transformateur d’impulsion ou de courant avec Pulse or current transformer with two secondary
Form 1 deux enroulements secondaires sur le même noyau windings on the same core and nine threaded
et neuf conducteurs primaires traversants primary conductors
06-13-13 Forme 2
Form 2
© BSI 10-1998
© BSI 10-1998
06-14-04 Redresseur en couplage à double voie (en pont) Rectifier in full wave (bridge) connection
EN 60617-6:1996
31
32
EN 60617-6:1996
Chapitre V: Piles et accumulateurs Chapter V: Primary and secondary cells and
batteries
Section 15 — Piles et accumulateurs Section 15 — Primary and secondary cells
Le trait long représente le pôle positif, le trait court The longer line represents the positive pole, the shorter
représente le pôle négatif one the negative pole
Pour un générateur rotatif, utiliser le For a rotary generator, use symbol 06-04-01.
symbole 06-04-01.
EN 60617-6:1996
33
34
EN 60617-6:1996
Section 18 — Exemples de générateurs de Section 18 — Examples of power generators
puissance
06-18-01 Générateur thermoélectrique à source de chaleur Thermoelectric generator, with combustion heat
par combustion source
06-18-03 Générateur thermoélectrique à source de chaleur Thermoelectric generator with radio-isotope heat
radioisotopique source
06-18-05 Générateur thermoionique à semiconducteur à Thermionic diode generator with radio-isotope heat
source de chaleur radioisotopique source
EN 60617-6:1996
35
36
EN 60617-6:1996
Section 19 — Régulateurs en boucle fermée Section 19 — Closed-loop controllers
L’astérisque doit, soit être remplacé par un symbol The asterisk shall either be replaced by letter(s) or a
littéral ou graphique indiquant le comportement de graph denoting the transition behavior, or be
transition, soit être omis. omitted.
Pour présenter un régulateur en boucle ouverte le To indicate an open-loop controller the symbol shall
symbole doit être utilisé avec une entrée seulement. be used with only one input.
EXEMPLE: EXAMPLE:
© BSI 10-1998
© BSI 10-1998
(Dans cette annexe, les numéros de la publication de 1983 sont mis entre (In this annex the numbering from 1983-edition is quoted in parentheses.)
parenthèses.)
(06-15-02)
06-A1-02 Forme 2
Form 2
(06-15-03)
EN 60617-6:1996
37
Annex B (informative)
38
EN 60617-6:1996
English alphabetic index
EN 60617-6:1996
Primary cell 06-15-01 single-phase 06-07-02
Pulse transformer 06-09-10 Synchronous motor 06-04-01
Pulse transformer with three threaded primary Synchronous motor, single-phase 06-07-02
conductors 06-13-10 Synchronous rotary converter, three-phase,
Pulse transformer with two secondary windings on the shunt-excited 06-07-05
same core and nine threaded primary conductors 06-13-12 Thermionic diode generator with non-ionizing
Reactor 06-09-08 radiation heat source 06-18-04
Rectifier 06-14-03
39
Thermionic diode generator with radio-isotope Transformer, measuring current, with three threaded
40
EN 60617-6:1996
heat source 06-18-05 primary conductors 06-13-10
Thermoelectric generator with combustion Transformer, measuring current, with two secondary
heat source 06-18-00 windings on the same core and nine threaded
Thermoelectric generator with non-ionizing primary conductors 06-13-12
radiation heat source 06-18-02 Transformer, measuring pulse, with three threaded
Thermoelectric generator with radio-isotope primary conductors 06-13-10
heat source 06-18-03 Transformer, measuring pulse, with two secondary
Three seperate windings 06-01-02 windings on the same core and nine threaded
Three-phase bank of single-phase transformers, primary conductors 06-13-12
connection star-delta 06-10-11 Transformer, measuring voltage 06-13-01A
Three-phase induction regulator 06-12-01 Transformer, pulse 06-09-10
Three-phase transformer with four tappings(taps) 06-10-09 Transformer, single-phase, with two windings and
Three-phase transformer with on-load tap changer 06-10-13 screen 06-10-01
Three-phase transformer, connection star-delta 06-10-07 Transformer, three-phase bank of single-phase
Three-phase transformer, connection star-star-delta 06-10-17 transformers, connection star-delta 06-10-11
Three-phase transformer, connection star-zigzag 06-10-15 Transformer, three-phase, connection star-delta 06-10-07
Three-phase winding, delta 06-02-05 Transformer, three-phase, connection star-star-delta 06-10-17
Three-phase winding, interconnected star 06-02-07 Transformer, three-phase, connection star-zigzag 06-10-15
Three-phase winding, open delta 06-02-06 Transformer, three-phase, with four tappings(taps) 06-10-09
Three-phase winding, phases not interconnected 06-01-04 Transformer, three-phase, with on-load tap changer 06-10-13
Three-phase winding, star, with neutral brought out 06-02-08 Transformer, voltage 06-13-01A
Three-phase winding, T 06-02-04 Two-phase winding 06-02-01
Three-phase winding, V (60°) 06-02-02 Two-phase winding, four-wire 06-01-06
Three-phase winding, zigzag 06-02-09 Voltage transformer 06-13-01A
Transformer choke 06-09-08 Winding for machines, commutating 06-03-01
Transformer reactor 06-09-08 Winding for machines, compensating 06-03-01
Transformer with centre tapping on one winding 06-10-03 Winding for machines, separate 06-03-03
Transformer with three windings 06-09-04 Winding for machines, series 06-03-02
Transformer with two windings 06-09-01 Winding for machines, shunt 06-03-03
Transformer with two windings, shown with voltage Winding, internally connected, four-phase, with
polarity indicators 06-09-03 neutral brought out 06-02-03
Transformer with variable coupling 06-10-05 Winding, internally connected, six-phase,
Transformer, current 06-09-10 double delta 06-02-10
Transformer, measuring current, with two cores with Winding, internally connected, six-phase, fork with
one secondary winding on each core 06-13-02 neutral brought out 06-02-13
Transformer, measuring current, with two secondary Winding, internally connected, six-phase, polygon 06-02-11
windings on one core 06-13-04 Winding, internally connected, six-phase, star 06-02-12
Transformer, measuring current, with five passages of Winding, internally connected, three-phase V (60°) 06-02-02
a conductor acting as a primary winding 06-13-08 Winding, internally connected, three-phase, delta 06-02-05
© BSI 10-1998
Transformer, measuring current, with one secondary Winding, internally connected, three-phase, star 06-02-07
winding with one tapping 06-13-06 Winding, internally connected, three-phase, T 06-02-04
Winding, internally connected, three-phase, zigzag 06-02-09
Winding, internally connected, two-phase 06-02-00
© BSI 10-1998
EN 60617-6:1996
41
|
|
|
|
|
|
|
|
|
BSI Ð British Standards Institution
|
|
|
|
|
|
| BSI is the independent national body responsible for preparing British Standards. It
|
| presents the UK view on standards in Europe and at the international level. It is
| incorporated by Royal Charter.
|
|
| Revisions
|
|
| British Standards are updated by amendment or revision. Users of British Standards
|
| should make sure that they possess the latest amendments or editions.
|
|
| It is the constant aim of BSI to improve the quality of our products and services. We
|
| would be grateful if anyone finding an inaccuracy or ambiguity while using this
| British Standard would inform the Secretary of the technical committee responsible,
|
| the identity of which can be found on the inside front cover. Tel: 020 8996 9000.
|
| Fax: 020 8996 7400.
|
|
| BSI offers members an individual updating service called PLUS which ensures that
|
| subscribers automatically receive the latest editions of standards.
|
|
| Buying standards
|
| Orders for all BSI, international and foreign standards publications should be
|
| addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
|
|
| In response to orders for international standards, it is BSI policy to supply the BSI
|
| implementation of those that have been published as British Standards, unless
|
| otherwise requested.
|
|
| Information on standards
|
| BSI provides a wide range of information on national, European and international
|
| standards through its Library and its Technical Help to Exporters Service. Various
|
| BSI electronic information services are also available which give details on all its
|
| products and services. Contact the Information Centre. Tel: 020 8996 7111.
|
| Fax: 020 8996 7048.
|
|
| Subscribing members of BSI are kept up to date with standards developments and
| receive substantial discounts on the purchase price of standards. For details of
|
| these and other benefits contact Membership Administration. Tel: 020 8996 7002.
|
| Fax: 020 8996 7001.
|
|
| Copyright
|
|
| Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of
|
| the publications of the international standardization bodies. Except as permitted
| under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,
|
| stored in a retrieval system or transmitted in any form or by any means ± electronic,
|
| photocopying, recording or otherwise ± without prior written permission from BSI.
|
|
| This does not preclude the free use, in the course of implementing the standard, of
|
| necessary details such as symbols, and size, type or grade designations. If these
|
| details are to be used for any other purpose than implementation then the prior
| written permission of BSI must be obtained.
|
|
| If permission is granted, the terms may include royalty payments or a licensing
|
| agreement. Details and advice can be obtained from the Copyright Manager.
|
| Tel: 020 8996 7070.
|
|
|
|
|
|
|
|
|
BSI |
|
389 Chiswick High Road |
|
London |
|
W4 4AL |
|
|
|
|
|
|