Eurocount TS

Eurocount TS

Next Generation Automated Hematology Analyzer Next Generation Automated Hematology Analyzer
New Technological Advancements Integrated
Special Instrument Features Latest Technology Inputs Touch Screen Operation
Highest Accuracy and Reliability
Color touch screen Single Board Technology as per On board Thermal Printer
Automatic Sample Rotor today's electronic standards Automatic Sample Rotor
Automatic sample dilution Patented Aperture Burn Technology
USB printer interface
Inbuilt Thermal Printer
Vacuum Pump Technology
Automatic calibration
Improved touch screen based software
USB printer interface
Only 25 µl sample volume Improved printer compatibility
External barcode reader (option)
Integrated statistics and QC program
Maintenance-free vacuum pump Highest Reliability
Online status for reagent and waste
Patented burn cleaning technology
1000 Results memory with Histograms
Cyanide free reagents Maintenance free parts
New power supply management

Clinical Evaluation :-
EurocountTS v/s Reference Method System Line Reagents
WBC y = 1,0034x + 0,1218 RBC y = 1,045x - 0,3 / 4
EUROCOUNTTS - DILUENT
y = 1,0143x 2 y = 1,0171x 2
R = 0,9926 R = 0,9592
30,0 6,00

20,0 4,00 EUROCOUNTTS - LYSE CF


10,0 2,00
EUROCOUNTTS - CLEANER
0,0 0,00
0,0 10,0 20,0 30,0 0,00 2,00 4,00 6,00

y = 1,0006x HGB y = 1,0632x - 7,982 y = 0,95x PLT y = 0,986x + 11,212


R2 = 0,9758 R2 = 0,9815
200 1000
150

100 500
50

0 0
0,0 50,0 100.0 150,0 200,0 0 200 400 600 800 1000

Made in Europe Made for India

Medsource Ozone Biomedicals Pvt. Ltd.


Marketing Office : Plot No. 7, Site No. 2,14/3 Milestone,
Delhi Mathura Road, Faridabad -121003 (Haryana) INDIA
Tel. : +91-129-4113607 / 08 Fax : +91-129-4049344
E-mail : mail@ozonebio.com Website : www.ozonebio.com
Eurocount TS State of the art 3-part Hematology analyzer
Best in Class Sampling Technology Unique Patented 3 stage Cleaning Technology
TS
Eurocount uses a special sample rotor where different types of sample cups, vials, vacuum/non vacuum tubes EurocountTS uses a unique patented 3 stage cleaning process including
etc. can be put. Sample aspiration is performed inside the analyzer making the analyzer safe to use, with a) High voltage pulse applied to aperture after each measurement (Aperture burn technology) for protein removal
b) Chemical cleaning after each run
complete blood handling inside the analyzer. Further, the analyzer is suitable for Indian conditions with less c) High pressure back flush
impact of dust, rodents and foreign particles which can often affect result quality and analyzer performance.
This process ensures the best possible cleaning and clog removal, leading to lower breakdown of the analyzer
and better reliability.

Superior Pump Technology


Liquid Valve Technology
TS
The vacuum pump offered on the Eurocount replaces the standard peristaltic pumps used in traditional
analyzers. Unlike peristaltics pumps which need regular maintenance, the vacuum pump is absolutely The liquid solenoid valves on EurocountTS are the latest superior valves available for liquid handling, much
maintenance free, long life and delivers accurate volumes with no need of regular service or calibration. improved over the traditional pinch valves. While the pinch valves required regular maintenance, liquid valves
offer practically maintenance free operation for many years, improving the overall reliability and trouble free
operation of the analyzer.
New Power System – Power Adapter
TS
Eurocount does not use SMPS (Switch Mode Power Supply) used so far on traditional analyzers. Instead it Online Reagent Inventory
uses a high quality external power adapter (similar to laptop adapters). This provides 2 major advantages –
The software offers a real time reagent inventory calculation system providing information on
The electrical noise which can lead to wrong results is reduced (the power supply is outside the analyzer),
inventory levels of all the reagents as well as the waste. The values are calculated as per usage of the
and the cost of repair of damaged adapter due to electrical disturbance is less than 10% of the cost of the
analyzer and can be easily reset by the user when a new pack is being changed, or waste is being
SMPS! This change improves the quality of results, reliability of the system and reduces service costs.
emptied.
Electronics as per today's standards
Use of low voltage boards, automated assembly of ICs, latest technology manufacturing equipment all lead to a
final product which is much more reliable than previous design electronic boards. Additionally, the energy New Additional Parameters – PLCC and PLCR for better platelet estimation
consumption has been reduced compared to the previous models of Hematology analyzers.
Almost all Hematology analyzers offer about 18 relevant parameters. The new EurocountTS offers the
standard parameters + 2 important parameters – PLCC and PLCR. While the total platelet count is
available in all Hematology analyzers, it is known that large platelets can be counted by the analyzer as
RBCs and RBC fragments can be counted as platelets. The platelet clumping presents another
challenge resulting in incorrect platelet counts. PLCR (Platelet Large Cell Ratio) provides excellent
Powerful Touch Screen Based Operating Software clues as to whether such a phenomenon is happening and is a particularly useful tool for
The operation of the analyzer relies on an extremely powerful yet simple to use software requiring almost no thrombocytopenia offering more information to the lab than a simple platelet count.
training. The software operates using a colour touch screen with several features such as self-testing, recall of
previous results, user maintenance etc. On Board Printer as well as External Printer Option

EurocountTS comes with an onboard 58mm graphical printer as standard with the analyzer. The
Modern Hardware - USB Port laboratory also has the option of using an external printing solution from a host of compatible
commercial printers available in the market using the USB port. The reports printed also include the
The standard USB ports in front and back of the analyzer allow unprecedented connectivity, software histograms for WBC, RBC and platelets.
upgradeability and data back-up ability. Additionally printer connectivity on several external printers is possible