Professional Documents
Culture Documents
Item Description
Total
Grand Total 51,300,517.55
Providing & fixing dial type (150 mm) pressure gauge with
isolation ball valve suitable for working pressure of 250
Nos 24 1050 25200
PSI. Cost shall be inclusive of providing any short pieces,
nipples, elbows etc as required.
Providing & fixing electronic type water level indicator
with LED panel mounted specified complete with probes & Nos 2 6500 13000
all control wiring etc.
Providing & fixing Auto Air vent for risers, suitable for
Nos 10 2250 22500
pressure not less than 16 Kg/Sq.cm.
Providing and fixing brass ball valve with gun metal ball
(suitable for test pressure of not less than 15 kg / sq.cm of
the following size : (Cost shall be inclusive of providing
necessary union / flange connection).
TOTAL 14610042.35
DESCRIPTION UNIT QTY
RATE AMOUNT
SPRINKLER, PIPING & ACCESSORIES:
pipes conforming to IS-1239 (Galavnised) with all
accessories like fittings ( pipes & fittings upto 50mm dia
threaded shall be the threaded Ductile Iron (ASTM A536)
or Cast Iron (ASTM A126) or Forged Steel fittings and for
pipes above 50 mm dia MS fitting with welded joint shall
be used) including tees, elbows, reducers, union, flanges,
rubber gaskets, GI nuts bolts, washer including
supporting/fixing the pipe on wall /ceiling with clamps,
hangers (using anchor fastners) as per specification.
wherever the pipes are crossing the walls/floors and
sealing the sleeves with glass wool in between & fire
sealent compound at either end all as per site requirement
requirements including cutting holes and chases in brick,
R.C.C work and making good the same to original
conditions complete in all respects. All hangers, clamps,
brackets etc. shall be of galvanized iron unless specified
otherwise and the supply of the same shall also be
included in rates under this head. Welding of any kind on
TOTAL 26682405.2
DESCRIPTION UNIT QTY
RATE AMOUNT
WATER CURTAIN SYSTEM
CONTROL PANEL
Control panel for control of above Fire pump, Jockey
Pump, total 4 pumps having incoming isolating switch
branch MCBS, incoming voltmeter with selector switch and
fuses. DOL starter with hand reset over load cum single
phase preventor type relay OFF / AUTO/ MANUAL No. 1 1450000 1450000
selector switches, ammeters to read current in any one
phase make level switch for low level out of protection an
electronic toggle relay for automatic alternating of pumps,
including providing adequate size cable from panel to
TOTAL
SITC of Electric Motor driven fire pumps (Hydrant) (Kirloskar / C.R.I.Make) of capacity
2400LPM and a head of 90m. Vendor to include a IP66 motor suitable for single/three
1.1 phase supply. Vendor to include in his quote a suitable base frame with two coat of anti Nos. 2 2
corrosive paint, power cabling, starter panel & all other supporting, rigging accessories &
consumables necessary to bring the system to satisfactory working condition. (1W +1S)
SITC of Electric Motor driven fire pumps (Sprinkler) (Kirloskar / C.R.I. Make) of capacity
2400LPM and a head of 90m. Vendor to include a IP66 motor suitable for single/three
1.2 phase supply. Vendor to include in his quote a suitable base frame with two coat of anti Nos. 2 2
corrosive paint, power cabling, starter panel & all other supporting, rigging accessories &
consumables necessary to bring the system to satisfactory working condition. (1W +1S)
SITC of Electric Motor driven fire pumps (Kirloskar / C.R.I. Make) of capacity 180LPM
and a head of 90m. Vendor to include a IP66 motor suitable for single/three phase
1.3 supply. Vendor to include in his quote a suitable base frame with two coat of anti Nos. 2 2
corrosive paint, power cabling, starter panel & all other supporting, rigging accessories &
consumables necessary to bring the system to satisfactory working condition. (1W +1S)
Supply, installation, testing and commissioning of Terrace fire pump (Kirloskar / C.R.I.
1.4
Make) comprising of the following: (1W +1S)
Horizontal mono-block centrifugal pump, suitable for operation on 415 volts ± 10%, 3
phase, 50 HZ A.C supply.
The pump casing shall be CI, shaft shall be CS & impeller / shaft sleeve / casing wearing
ring shall be bronze and gland type stuffing box. The system shall be complete with
necessary pressure gauge with gun metal shut off cock on delivery side. (The pump
should meet the condition and shall be gotten approved by the Local fire Authority).
Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC
supply for the above pump with speed of 2900 R.P.M.
Suitable cement concrete foundation with plaster, (design and drawing to be provided by
the Contractor while the foundation will be done by others) complete with Antivibration
arrangement of cushy foot mounting.
For pump defined above & of duty as follows :
Flow : 900 LPM
Head : 32 mts Nos. 2 2
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia
& 1500 mm height) for pressurization of hydrant / sprinkler system complete with
adequate pressure switches (as per design / requirement) with valves to operate as per
1.5 operating sequences including 25 mm dia drain valve, air release valve with stop Set 2 2
cock on the top, minimum 50 mm dia inlet with isolating valve duly painted from inside
and outside with two coats of synthetic enamel paint over a coat of primer complete as
required. (Vessel should be suitable for rated working pressure).
Providing & fixing dial type (150 mm) pressure gauge with isolation ball valve suitable
1.6 for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, Nos 24 24
nipples, elbows etc as required. (Make : HD Fire)
Providing & fixing electronic type water level indicator with LED panel mounted
1.7 Nos 2 2
specified complete with probes & all control wiring etc. (Make : Honeywell)
Providing & fixing Auto Air vent for risers, suitable for pressure not less than 16
1.80 Nos 10 10
Kg/Sq.cm. (Make : Zoloto)
Supply, installation, testing and commissioning pressure switches suitable for pressure
1.90 Nos 14 14
rating of 16 Kg/Cm2. (Make : Danfoss)
Contractor shall include in his rates for providing level controllers, pressure switches,
Note : wiring, cabling from level controller / pressure switch to panel etc. complete as required to
operate the system automatic/manual. Pump shall be protected against running dry.
TOTAL
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
2 HYDRANTS, PIPING & ACCESSORIES:
2.1.1 25 mm dia RM 15 15
2.1.2 40 mm dia RM 0
2.1.3 50 mm dia RM 7 7
2.1.4 65 mm dia RM 0
2.1.5 80 mm dia RM 120 120
2.1.6 100 mm dia RM 20 20
2.1.7 150 mm dia RM 4025 410 410
2.1.8 200 mm dia RM 20 20
Providing two coats of synthetic enamel paint of approved shade over a two coats of
primer. Prior to application of primer the surface should be cleaned for any dirt, rusts,
2.2
rough substance etc. Including painting of legends both direction arrow as per the
approval of the Project Manager
2.2.1 25 mm dia RM 15
2.2.2 40 mm dia RM 0
2.2.3 50 mm dia RM 7
2.2.4 65 mm dia RM 0
2.2.5 80 mm dia RM 120
2.2.6 100 mm dia RM 20
2.2.7 150 mm dia RM 4025
2.2.8 200 mm dia RM 20
Providing, laying, jointing and testing underground piping with following sizes of MS
class `C' (heavy class) pipes conforming to IS:1239 with accessories like fittings including
tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers including
2.3 excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus
material, providing adequate support to the pipe and making good the same complete as
required. Rate shall include for dewatering necessary to execute the work. The pipe
shall not be less than 1.0 m below ground level at any point. (Make : Jindal)
2.3.1 80 mm dia RM 0
2.3.2 100 mm dia RM 0
2.3.3 150 mm dia RM 820 410
Providing and fixing forged brass ball valve with forged brass ball (suitable for test
2.4
pressure of not less than 16 kg / sq.cm of the following size : (Make : Zoloto 1008B)
(Cost shall be inclusive of providing necessary union / flange connection).
2.4.1 20 mm dia Nos. 0
2.4.2 25 mm dia Nos. 91 5 1 1 1
Providing & fixing of CI /forged brass body gate valves confirming to IS:778 class II with
2.5 high tensile brass rising stem suitable for the system pressure 16 kg/ cm2 including &
fitting etc complete as required. (Make : Zoloto 1008B)
2.5.1 50 mm dia No. 2
2.5.2 65 mm dia No. 5
2.5.3 80 mm dia No. 0
2.5.4 100 mm dia No. 0
Providing and Fixing non rising Spindle type sluice valve PN 16 rating of following dia
2.6
complete with flanges, nuts, bolts etc. (Make : Zoloto)
2.6.1 80 mm dia Nos. 0
2.6.2 100 mm dia Nos. 0
2.6.3 150 mm dia Nos. 8 4
2.6.4 200 mm dia Nos. 4 2
2.6.5 250 mm dia Nos. 0
Providing and fixing tamper switch on butterfly valve / sluice valve / isolation valve for
remote mointing of the valve open / close position. The tamper switch shall be provided
2.7 Set
with potential free contact with 2 nos. NONC. The valve shall also be provided with
manual lock & chain arrangement. (Make : Zoloto)
Providing & fixing C.I. Horizontal flap type Non Return valve of rating PN 16 rating
2.8 including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as
required. (Make : Zoloto)
2.8.1 50 mm dia Nos. 0
2.8.2 65 mm dia Nos. 0
2.8.3 80 mm dia Nos. 8 4
2.8.4 100 mm dia Nos. 0
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
2.8.5 150 mm dia Nos. 5 2
2.8.6 200 mm dia Nos. 4 2
Providing, fixing and commissioning of spring loaded relief valve suitable for pressure
2.90 of 16 Kg / sq.cm including flanges, nuts, bolts, washers etc. complete as required. (Make
: Zoloto)
2.9.1 50 mm dia Nos. 2 1
Providing and fixing C.I.`Y' strainer with bronze perforated sheet basket including
2.11 rubber gasket, flanges, nuts, bolts and washers, complete as required. (For Alarm Gong
Valve) (Make : Zoloto 1084)
2.11.1 80 Nos. 8
2.11.2 150 mm dia Nos. 2
Providing & fixing S.S. (316 Grade) metal fire hydrant double landing valve with 150
mm N.B. flanged inlet, brass spindle controlled 63 mm dia female instantaneous
outlet type. S.S. (316 Grade) coupling, blank cap, chain, twist release type lug & all
2.12 Nos. 80 1 1 1
accessories Conforming to IS:5290. Including fixing with anchor fastner and flanged
tapping from wet riser and providing pressure gauge with gun metal ball valve complete
as required. (For Internal) (Make : SHAHBHOGILAL)
Providing & fixing S.S. (316 Grade) metal fire hydrant single landing valve with 80 N.B.
flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type.
SS-316 coupling, blank cap, chain, twist release type lug & all accessories Conforming to
2.13 Nos. 36 3 3 3
IS:5290. Including fixing with anchor fastner and flanged tapping from wet riser and
providing pressure gauge with gun metal ball valve complete as required. (For External)
(Make : SHAHBHOGILAL)
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
Providing & fixing S.S. (316 Grade) metal fire hydrant double landing valve with 100
N.B. flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet
type. SS-316 coupling, blank cap, chain, twist release type lug & all accessories
2.14 Nos. 0
Conforming to IS:5290. Including fixing with anchor fastner and flanged tapping from
wet riser and providing pressure gauge with gun metal ball valve complete as required.
(For External) (Make : SHAHBHOGILAL)
Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long
and 20 mm dia heavy duty rubber water hose, 20 mm dia gate valve stop cock, (IS:778,
class - II) terminating with G.M. Coupling & nozzle of 6mm outlet with shut off valve
2.15 Nos. 80 1 1 1
confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets
(including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to
IS:884-1985 (Reaffirmed 2000) complete as required.(Make : SHAHBHOGILAL)
Providing & fixing non-percolating rubber reinforced lined fire hose pipe (as per IS :
636) type-B of 63 mm dia and length as described below. The hose shall be rated for
2.16 brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS 316 male &
female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm
copper wire (Location : Internal fire hydrant) (Make : SHAHBHOGILAL)
Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia
and 15 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested
for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI
2.17 Nos. 36 3 3 3
marked SS 316 male & female coupling (IS:903) bound & riveted to hose pipe with
copper rivets & 1.5 mm copper wire (Location : External fire hydrant) (Make :
SHAHBHOGILAL)
Providing and fixing standard firemans axe with heavy rubber handle. (Make :
2.19 Nos. 80 1 1 1
SHAHBHOGILAL)
Providing and fixing weather proof lockable cabinet of size not less than 0.6x
0.75(height) x 0.25 mtr made out of GI sheet with two coats of epoxy paint of 16 gauge
thickness having central opening and 4 mm thick glazed glass doors (Two nos.)
2.20
suitably marked on the outside with the letters "FIRE HOSE" including necessary
locking arrangement and shall be painted with one coat of primer and two coats of
synthetic enamel paint of approved shade. (Make : SHAHBHOGILAL)
The cabinet shall be suitable to accommodate 2 nos. 15 mtr long Hose pipe & 1 No
branch pipe nozzle. It shall be mounted on raised Brick platform complete as required.
(Cost shall be inclusive of providing break glass box containing key for the cabinet along
Nos. 36 3 3 3
with hammer).
Providing & fixing lockable indoor type fire hose cabinet frames fabricated from 40 x 40 x
5 angle iron sections and 16 gauge MS sheet with full front glass door and locking
arrangement, suitable to accommodate landing valves, 2 nos. 15 m long hoses, first-aid
2.21 hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted
with two coats of primer and two or more coats of synthetic enamel paint of approved
make and shade of as required (Approx 1.5 m (high) x 0.9 m (wide) x 0.6 m (deep) ).
The item shall be complete of MS housing with front door.
(Cost shall be inclusive of providing break glass box containing key for the cabinet along
Nos. 80 1 1 1
with hammer).
Providing & fixing gun-metal fire brigade inlet connection (suction collecting head)
consisting of 4 Nos. 63 mm dia instantaneous type male couplings with built-in check
2.22 valves, 1 No. 150 mm dia Butter fly valve, and 150 mm dia flanged outlet Non return Nos. 1
valve complete with bolts, nuts and rubber insertions as required and as per IS:904-1963.
(Make : SHAHBHOGILAL)
Providing & fixing MS cabinet (to enclose above FB connection) fabricated from 16g SS
304 sheet with full front glass door and locking arrangement duly painted with two coats
2.23 of primer and two or more coats of synthetic enamel paint of approved make and shade Nos. 1
and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.6m x
0.45m)
Providing & fixing of Fire Brigade (Siamese) inlet connection with 2 (two) connecting
points of 63mm size male inlet connections, fabricated out of G.I. Pipes and incorporating
a C.I. non return valve for wet riser. Vendor to paint the same with one coat of primer &
2.24 Nos. 1
two coats of anti corrosive fire red paint. Vendor to include in his quote all costs all
fittings, supports, accessories, rigging equipments & consumables necessary to bring the
system to satisfactory working condition.(Make : SHAHBHOGILAL)
Providing and fixing heavy class MS delivery headers of required length conforming to
IS:1239 / IS:3589 with welded joints standard MS Fittings and with end flange
2.25 connections having inlet & outlet flanged connections including GI supports from wall/
floors & ceiling complete as required. Cost should be inclusive of all supports / clamps /
brackets, anchor fastner etc. as required (all in GI). (Make : Zoloto)
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
2.25.1 50 mm dia RM 0
2.25.2 65 mm dia RM 0
2.25.3 80 mm dia RM 0
2.25.4 100 mm dia RM 0
2.25.5 150 mm dia RM 0
2.25.6 200 mm dia RM 10
2.25.7 250 mm dia RM 0
2.25.8 300 mm dia RM 0
Providing two coats of synthetic enamel paint of approved shade over two coats of
primer. Prior to application of primer the surface should be cleaned for any dirt, rusts,
2.26
rough substance etc. Including painting of legends both direction arrow as per the
approval of the Project Manager
2.26.1 50 mm dia RM 0
2.26.2 65 mm dia RM 0
2.26.3 80 mm dia RM 0
2.26.4 100 mm dia RM 0
2.26.5 150 mm dia RM 0
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
2.26.6 200 mm dia RM 10
2.26.7 250 mm dia RM 0
2.26.8 300 mm dia RM 0
Constructing brick masonary chamber (for housing valve) in brick work with bricks of
class 75 in cement mortar 1:5 (1 cement:5 fine sand) 12 mm thick plaster on inside with a
floating coat of neat cement &rough plaster on external faces with cement mortar 1:3 (1
2.27 cement : 3 coarse sand) with 150 mm thick PCC (1:4:8). Including providing 100 mm
thick R.C.C. top slab complete in all respect. Cost shall be inclusive of excavation in
earth, shoring, dewatering, support to valve and access rungs as required to complete
the work.
Providing & fixing DI medium duty manhole cover with frame of 900 mm x 900 mm
2.29 Nos. 3
for valve chamber (total weight of cover and frame to be not less than 75 kg for CI).
Providing and laying Cement concrete for anchor / thrust blocks of 1:2:4 [1 cement :
2.30 Cum 10
2 fine aggregate : 4 coarse aggregate, 40 mm nomional size as per standard design.
Designing, providing and fixing Orifice plate made out of stainless steel plate (thickness
2.31 as per specification) for following size of pipe to reduce pressure upto 3.5 Kg/sqcm
complete in all respects. (Make : HD Fire)
2.31.1 65 mm dia Nos. 0
2.31.2 80 mm dia Nos. 0
2.31.3 100 mm dia Nos. 36 3 3 3
2.31.4 150 mm dia Nos. 80 1 1 1
TOTAL
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
3 SPRINKLER, PIPING & ACCESSORIES:
Providing, laying, jointing and testing of following sizes of pipes conforming to IS-1239
(Galavnised) with all accessories like fittings ( pipes & fittings upto 50mm dia threaded
shall be the threaded Ductile Iron (ASTM A536) or Cast Iron (ASTM A126) or Forged
3.1 Steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used)
including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer
including supporting/fixing the pipe on wall /ceiling with clamps, hangers (using anchor
fastners) as per specification. (Make : Jindal)
MS pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing
the walls/floors and sealing the sleeves with glass wool in between & fire sealent
compound at either end all as per site requirement requirements including cutting holes
and chases in brick, R.C.C work and making good the same to original conditions
complete in all respects. All hangers, clamps, brackets etc. shall be of galvanized iron
unless specified otherwise and the supply of the same shall also be included in rates
under this head. Welding of any kind on the galvanized support / hanger shall not be
permitted.
Providing two coats of synthetic enamel paint of approved shade over two coats of
primer. Prior to application of primer the surface should be cleaned for any dirt, rusts,
3.4
rough substance etc. Including painting of legends both direction arrow as per the
approval of the Project Manager
Providing & fixing of butterfly valve of PN 16 rating with flanges, nut bolts & gaskets
3.5 complete required. Butterfly valve shall be with pad locking arrangement.
(Make : Zoloto)
Providing & Fixing of Installation Control Valve with turbine type automatic Alarm Gong
3.7 to be connected with control valve, drain & test valve and all other necessary
components as per manufacturer's specifications complete as required. (Make : Tyco)
Providing & fixing brass quartzoid sprinklers (UL listed) (Stander Response) of 15 mm
3.8 dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type
& temperature rating shall be as follows : (Make : Tyco)
3.8.1 Recessed pendent type sprinkler (20 mm adjustable) (68 deg.c) Nos RO
3.8.2 Recessed pendent, horizontal sidewall sprinkler (15 mm adjustable) (68 deg.c) Nos 476 49 49
Recessed pendent, horizontal sidewall sprinkler (15 mm adjustable) (68 deg.c) (Spare
Set 2 2
Qty., 24 Nos. - 1Set)
3.8.3 Pendent type (15 mm adjustable) (68 deg.C) with escutcheon plate Nos 7972 125 217 217
Pendent type (15 mm adjustable) (68 deg.C) with escutcheon plate. (Spare Qty., 24
Set 5 5
Nos. - 1Set) (Make : Tyco)
Providing and Fixing electrically operated water flow switches (Paddle type)
3.10 including tamper switch and accessories, complete with tap off socket arrangement as
required, with potential free contact with 2 Nos. NONC. (Make : System Sensor)
3.10.1 50 mm dia No. QR
3.10.2 65 mm dia No. QR
3.10.3 80 mm dia No. QR
3.10.4 100 mm dia No. QR
3.10.5 150 mm dia No. 82 1 1 1
Providing and fixing inspectors test assembly complete with test valve, sight glass
3.11 sectional drain valve, union; necessary piping, threading, jointing & with corrosion
resistant orifice all complete strictly as per drawing.
Cost shall be inclusive for approval of fire hydrant & sprinkler system from local fire
authority and any other relevant statutory authority at initial & various other stages of
works, including preparation of report / drawings as per fire authority. Contractor shall
Note :
include cost of all liaison works which are not explicitly mentioned above but are
mandatory to have fire authority approval (any statutory charges will be reimbursed as
per actual upon production of the invoice / challan).
TOTAL
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
4 WATER CURTAIN SYSTEM
Providing and fixing of UL listed Deluge valve, Horizontal/ Vertical mountong, Ductile iron
body, Aluminium bronze clapper & latch, EPDMClapper seal, Nitril rubber Bushing and
seat O ring, S.S shaft & EPDM diaphargm complete with eletrical release trim, Hydraulic
4.1 release trim, Pressure Switch, solenoid valve actuator & control panel including
necessary accessories, complete with tap off socket arrangement as required, with
potential fress contact with 2 Nos. NO/NC & ON/OFF Arrangement and all other
associated works of complete as required. (Make : HD Fire)
4.1.1 80 mm dia Nos.
4.1.2 100 mm dia Nos. 10 1 1
4.2 Providing and fixing of Water curtain nozzeles (deluge valve operated) (Make : Safex) Nos. 468 44 45
TOTAL
ITEM
DESCRIPTION UNIT FINAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM
NO.
5 PORTABLE FIRE EXTINGUISHERS:
ISI marked (IS:2171) Portable Dry Chemical Powder Type Fire Extinguisher with Gun
5.1.1 Metal cap and nozzle complete in all respects including initial fill of powder and wall
suspension bracket. (Make : Safex)
ISI marked (IS:2878) portable CO2 type fire extinguisher type. Including valve, discharge
hose of not less than 10 mm dia & 1 M long complete in all respects including initially
5.1.2 filled with CO2 gas. (Loc : -near car parking lots, floor panel room, transformer room,
generator room, pump room / stp plant room, AHU rooms and lift machine room) (Make :
Safex)
Dry powder ABC type fire extinguisher 6 Kgs. Capacity, initial filling in brand new
cylinder of powder coated finish, fitted with Gun metal union, high pressure CO2 gas
5.1.4 Nos. 50 46
cartridge & wall mounting bracket etc. complete confirming to IS:940.
(loc :at each floor lobby area) (Make : Safex)
SITC of galvanised mild steel Fire bucket with clean & dry sand with stand in
accordance with IS 2546. Fire bucket shall have two coats of anti corrosive paint, two
coats of fire red paint on its outside & two coats of white paint on the inside. The word
"FIRE" shall be clearly stencilled on it in accordance with IS 2546. Vendor to include in
5.1.5 Nos. 202 98 20 20
his quote all costs relating to mounting of the bucket at locations stated by the Fire NOC
& the architect. Vendor to include in his quote all costs all accessories, consumables,
fittings & rigging equipments necessary for the satisfactory installation of the same.
(Make : Safex)
TOTAL
6 CONTROL PANEL
Providing, fabricating & fixing Sheet clad Floor mounting Control panel for control of
above Fire pump, Jockey Pump, total 4 pumps having incoming isolating switch branch
MCBS, incoming voltmeter with selector switch and fuses. DOL starter with hand reset
over load cum single phase preventor type relay OFF / AUTO/ MANUAL selector No. 1 1
switches, ammeters to read current in any one phase make level switch for low level out
of protection an electronic toggle relay for automatic alternating of pumps, including
providing adequate size cable from panel to pump and from panel to level switch.
TOTAL
TOWER A TOWER B
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
410
1 1 1 1 34 5 1 1 1 1 1
4
2
4
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
1 2
2
1 1 1 34 1 1 1 1 1
3 3 3 3 3 3 3 3
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
1 1 1 34 0 0 1 1 1 1 1
2 2 2 68 0 0 2 2 2 2 2
3 3 3 3 3 3 3 3
1 1 1 34 0 1 1 1 1 1
1 1 1 34 0 0 1 1 1 1 1
3 3 3 3 3 3 3 3
1 1 1 34 0 0 1 1 1 1 1
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
3 3 3 3 3 3 3 3
1 1 1 34 0 0 1 1 1 1 1
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
500 470 480 115 4624 430 350 340 370 400
17 23 20 30 170 20 25 26 24 22
25 23 22 680 22 23 25 24 23
44 46 40 850 45 45 45 45 45
15 16 18 952 5 5 5 5 5
1088
102
360 360 340 85 120 135 130 125 120
500 470 480 115 4624 430 350 340 370 400
17 23 20 30 170 20 25 26 24 22
25 23 22 0 680 22 23 25 24 23
44 46 40 0 850 45 45 45 45 45
15 16 18 0 952 5 5 5 5 5
0 0 0 0 1088 0 0 0 0 0
0 0 0 0 102 0 0 0 0 0
360 360 340 85 0 120 135 130 125 120
6 6 6 2 34
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
49 49 40 48 48 48 48
1 1 1 1 34 1 1 1 1 1
1 1 1 1 34 1 1 1 1 1
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
1 1 1 1 1 1 1
45 45 44 45 52 52 52
3RD PODIUM 4th PODIUM 5TH PODIUM CLUB LEVEL TYPICAL TOTAL BASEMENT GROUND 1ST PODIUM 2ND PODIUM 3RD PODIUM 4TH PODIUM
20 20 20 68
20 20 20 2
TOWER B
215 900
1 34
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
1 34
3
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
1 34
2 68
1 34
1 34
1 34
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
10
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
10
3
1 34
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
34
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
48
216 63 2720
1 1 34
1 1 34
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
1 10
0
44 468
0
0
5TH PODIUM CLUB LEVEL TYPICAL TOTAL EXT. SHAFT
68
2
NAME OF THE PROJECT: AJMERA TREON Revision
Date
Subject: COSTS FOR FIRE FIGHTING WORKS Checked By
Date
Accepted By
ITEM UNIT PRICE
DESCRIPTION UNIT QTY
NO. RATE AMOUNT
7.1.1 S/I/T/C Manual Call Point with break glass push button in metal enclosure Each 25
S/I/T/C of UL-FM Approved Potential-free, Form-C, SPDT contact based relay module to
7.1.4 Each 5
trigger 3rd party utilities like AHU shut-off, Pressurization fan activation, etc.
S/I/T/C Microprocessor based conventional Fire Alarm Control Panel (FACP) suitable to
7.1.5 cater to Above Call points and Hooters etc to complete the System Each 1
as per IS standard.
Wiring for Fire Alarm system with 2 core 1.5 sq.mm Stranded FRLS copper conductor
7.1.6 cable in the concealed 20MM Rigid MMS PVC conduit PVC conduit as per specification Mtr 300
and Relevant drawings as required.
Supply Installation testing & commissioning of Public Address System considering the
following items required for the system .
The System shall comply to complying to IS 2189 , Relevant IS Standards ,Local Fire
Officer requirement, Specification and Relevant Drawings.
"FRLS" wires shall comply to IS 694:1990 / IEC 60227-1 to 5:1979
Rigid PVC conduit Conduits and accessories complying to IS 9537(Part 1):1980/ IEC
60614-1(1978)
Refer Drawing
"TN-OR-FA-PA-SCH" For FA and PA Schematic
"TN-TYP DET-E-5000" For Fire Alarm and PA system Device Installation Detail
Wiring for speakers & volume control units with 2 core 1.5 sq.mm Stranded FRLS
7.2.6 copper conductor cable in the concealed 20MM Rigid MMS PVC conduit PVC conduit as Mtr 150
per specification and Relevant drawings as required.