You are on page 1of 8

CBT-400

CIRCUIT
BREAKER
TEST SYSTEM
From the world leader in breaker testing and monitoring
C O M PA N Y OV E R V I E W

With design and manufacturing


CBT-400 CIRCUIT BREAKER TEST SYSTEM

facilities both in the USA and ■ Simple to Operate ■ Test Sequencing and Cycling
Europe, Hathaway Power ■ Internal Storage of Records ■ Multiple Test Configurations

Instrumentation produce a ■ Intelligent Results Analysis ■ Powerful Replay Software
comprehensive and cost-effective
TECHNICAL SUMMARY
range of fault recorders and circuit
The new CBT-400 is the latest microprocessor based Circuit Results can also be downloaded from the CBT-400 to a
breaker test products designed Breaker Test System for the timing and testing of medium Windows™ Replay™ package where they can be analyzed
exclusively for the Power Industry. and high voltage circuit breakers. In response to ever and archived. Also featured in this package is a Remote
growing needs for field and factory testing of circuit Configuration program to allow modification of test
The European division based in
breakers, Hathaway has developed a succesor to the CBT- parameters via a PC. Results may also be transferred to
Belfast has been accredited to ISO 4, which has a ten year history of successful circuit breaker any “off the shelf” Windows™ database package for easy
9001 which underlines the testing worldwide. generation and customising of reports.
The CBT-400 can acquire the following information: The CBT-400 has been designed for use in high voltage
company's commitment to produce
sub-stations and is immune
quality products for a global market. ■ Contact Opening / Closing timings. to the high levels of
■ Open / Close coil currents. electrical interference
Hathaway's expertise, gained from
■ Mechanism Travel and Velocity. typically found in this
many years of experience in ■ Station battery voltage. environment. The
servicing this international market, ■ Dynamic contact resistance. system is contained in a
rugged field portable
allied to close working relationships
The system is controlled using an integral keypad and LCD case and has been
with our customers, allows us to display. Simple operation is obtained with the CBT-400's designed to withstand
introduce a high degree of systems menu driven software, designed to prompt the operator the high levels of
and requiring minimal reference to the operating manual. mechanical shock
flexibility. Such experience and The CBT-400 can perform automatic result analysis using encountered in this
versatility has resulted in the pre-programmed limits for expected results. When a application.
breaker test is carried out the CBT-400 compares the actual
development of the CBT-400 Circuit
results with those expected. Any variances outside the limits
Breaker Test System. are indicated on the print-out and LCD display.
An additional feature of the CBT-400 for factory testing
The CBT-400 - a cost effective test allows a number of tests to be carried out in a sequence.
This sequence can then be cycled up to 99 times and the
system providing accurate
results of each test can be saved to memory.
information for factory and field 16 different test configurations can also
testing of circuit breakers. be stored within the memory, any of
which can be accessed on site. All results
can be stored within the CBT-400's
internal memory and retrieved at a later
date via direct computer link or modem,
eliminating the requirement for a PC to be
carried on site.

Windows™ is a trademark of the Microsoft Corporation.


Replay™ is a trademark of Hathaway Systems Limited.
From the world leader in breaker testing and monitoring
C O M PA N Y OV E R V I E W

With design and manufacturing


CBT-400 CIRCUIT BREAKER TEST SYSTEM

facilities both in the USA and ■ Simple to Operate ■ Test Sequencing and Cycling
Europe, Hathaway Power ■ Internal Storage of Records ■ Multiple Test Configurations

Instrumentation produce a ■ Intelligent Results Analysis ■ Powerful Replay Software
comprehensive and cost-effective
TECHNICAL SUMMARY
range of fault recorders and circuit
The new CBT-400 is the latest microprocessor based Circuit Results can also be downloaded from the CBT-400 to a
breaker test products designed Breaker Test System for the timing and testing of medium Windows™ Replay™ package where they can be analyzed
exclusively for the Power Industry. and high voltage circuit breakers. In response to ever and archived. Also featured in this package is a Remote
growing needs for field and factory testing of circuit Configuration program to allow modification of test
The European division based in
breakers, Hathaway has developed a succesor to the CBT- parameters via a PC. Results may also be transferred to
Belfast has been accredited to ISO 4, which has a ten year history of successful circuit breaker any “off the shelf” Windows™ database package for easy
9001 which underlines the testing worldwide. generation and customising of reports.
The CBT-400 can acquire the following information: The CBT-400 has been designed for use in high voltage
company's commitment to produce
sub-stations and is immune
quality products for a global market. ■ Contact Opening / Closing timings. to the high levels of
■ Open / Close coil currents. electrical interference
Hathaway's expertise, gained from
■ Mechanism Travel and Velocity. typically found in this
many years of experience in ■ Station battery voltage. environment. The
servicing this international market, ■ Dynamic contact resistance. system is contained in a
rugged field portable
allied to close working relationships
The system is controlled using an integral keypad and LCD case and has been
with our customers, allows us to display. Simple operation is obtained with the CBT-400's designed to withstand
introduce a high degree of systems menu driven software, designed to prompt the operator the high levels of
and requiring minimal reference to the operating manual. mechanical shock
flexibility. Such experience and The CBT-400 can perform automatic result analysis using encountered in this
versatility has resulted in the pre-programmed limits for expected results. When a application.
breaker test is carried out the CBT-400 compares the actual
development of the CBT-400 Circuit
results with those expected. Any variances outside the limits
Breaker Test System. are indicated on the print-out and LCD display.
An additional feature of the CBT-400 for factory testing
The CBT-400 - a cost effective test allows a number of tests to be carried out in a sequence.
This sequence can then be cycled up to 99 times and the
system providing accurate
results of each test can be saved to memory.
information for factory and field 16 different test configurations can also
testing of circuit breakers. be stored within the memory, any of
which can be accessed on site. All results
can be stored within the CBT-400's
internal memory and retrieved at a later
date via direct computer link or modem,
eliminating the requirement for a PC to be
carried on site.

Windows™ is a trademark of the Microsoft Corporation.


Replay™ is a trademark of Hathaway Systems Limited.
A powerful test system that is easy to use . . . with results anyone can understand
S P E C I F I C AT I O N MEMORY SAMPLE PRINTOUT L Maximum coil currents recorded.
Sizes: M A “Warning !” will appear beside any test result that
INPUTS
256kbytes, 1Mbyte or 4Mbytes Static RAM. is
Contact Inputs:
(The use of data compression allows approximately 10s outside the test limits set in the “Test parameter
Up to four breaks per phase, each break can consist of HATHAWAY SYSTEMS LTD
of recorded data to be stored per 1Mbyte of memory, at C.B.T.400
limits”.
one Main and one Resistor break in parallel. It is not H.V. CIRCUIT BREAKER TEST SYSTEM
a sample rate of 10kHz). N Measurements taken from the mechanism travel
necessary to disconnect Resistor or Main contacts. Record: 3
Max Record Lengths: curve.
Resistor contact range: S t a t i o n a N me : B O UCHER ROAD
256kbytes:- 10kHz - 500ms C I R C U I T A N ME : A P OLLO
29ohms - 10kohms B R E A K E R A N ME : S . BELFAST
A
1kHz - 5s B R E A K E R O N . : 1 4 55
Timing Accuracy: O p e r a t o r I D : G R AEME EWART
100Hz - 50s
100µs D a t e and time : 1 0 : 53:26 27/06/96

EVENTS
AUXILIARY
BREAKS

COIL CURRENTS

ANALOGUES
1 or 4Mbytes:- 10kHz - 2s O p e r a tion : O p e n
Analog Inputs: T r i g g er : C o i l current
1kHz - 20s M a c h i ne ID : C B T -400-95-01
2 channels dedicated for Open and Close coil currents. S e t u p name : 1 2
100Hz - 200s

A1
A2

B1
B2

C1
C2

OI

A3
4 or 6 user configurable channels for measuring S a m p le Ra te : 1 0 k Hz E
R e s i stor range : l o w
mechanism travel and velocity, station battery voltage, TRIGGERING T r a v el Un its : m e t ric
T r a v el Ch 3-Ch8 : 1 0 0 000
contact resistance, etc. Start Trigger: O p e n coil range : 7 . 5 A
C l o s e coi l range : 7 . 5 A
B
Expandable to have a further 8 user configurable Internal contactor, Open coil current, Close coil current,
R e c o rd Length : 0 . 1 5 se c s
channels that can be incorporated into the case lid. change in any event status, change in analog status. R e l a y on time : 0 . 0 5 0 s e cs
O p e n / close delay : 0 . 0 0 se c s
Analog Accuracy: C l o s e / open delay : 0 . 0 0 se c s F G H
ISOLATION D e b o unce time : 0 . 0 0 5 s e cs
Better than 1%.
Analog and event inputs, coil initiation outputs: O p e n dat u m A : 2 0 . 0 0 m m
Analog Resolution: O p e n dat u m B : 4 0 . 0 0 m m
2.5kVac channel to channel and channel to earth. C l o s e da t u m A : 0 . 0 0 0 m m
12 bits. C l o s e da t u m B : 0 . 0 0 0 m m

Event Inputs: ELECTRICAL INTERFERENCE Test p a r ameter limits


P a r ameter M i n M a x U n its
4 channels user selectable for 110V or 220Vdc nominal. High voltage impulse: M a x open current : 2 . 0 0 0 3 . 0 0 0 A m ps
M a x close current : 2 . 0 0 0 3 . 0 0 0 A m ps
Expandable to have a further 8 user selectable channels IEC 255.4 withstand. W i p e : 7 . 5 0 0 8 . 5 0 0 m m J
S t r oke : 5 5 . 0 0 6 5 . 0 0 m m
that can be incorporated into the case lid. O v e r travel
Surge withstand: R e b ound
:
:
4
2
.
.
0
0
0
0
0
0
5
3
.
.
0
0
0
0
0
0
m
m
m
m C K
O p e n datum veloci t y : 2 . 0 0 0 3 . 0 0 0 m / s
IEC 255.4, 2.5kV 1MHz. C l o se datum veloc i ty : 2 . 0 0 0 3 . 0 0 0 m / s
RECORDING L a s t touch veloci t y : 1 . 0 0 0 2 . 0 0 0 m / s
F i r st part veloci t y : 0 . 5 0 0 1 . 0 0 0 m / s
Sample Rates: POWER SUPPLY
10kHz, 1kHz or 100Hz, user selectable. 85 - 264Vac, 120 - 370Vdc L M
C hannel information
N ame Label Zero FSD Units
OUTPUTS PRINTER A 1 Open current 0 7.5 Amps Coil currents
A 3 TRAVEL A 0.000 100.0 mm D Max open current : 3.978 Amps Warning !!!
Coil Initiation: Internal: Velocity full scale: 3.296 m/s Travel c h annel An 3 (Phase A)
Voltage free contactors 250Vdc, 25A. Wi p e : 8.913mm Warning !!!
Thermal 112mm - 8 dots per mm. Time spacing: 10 msecs
St r o ke : 61.09mm
Alarm Output: Ov e r travel : 4.371mm
External: Re b o und : 2.979mm
Ac t u al open datum A : 19.92mm
N
Rating 110Vdc, 0.5A. Epson® compatible parallel printer. Ac t u al open datum B : 39.92mm
Op e n datum velocity : 2.222 m/s
Remote Start: Fi r s t part velocity : 0.888 m/s
For use with hand-held trigger switch. CONNECTIONS
Printer Port All breaker connections are terminated to 4mm safety A Test identification data. All times in milli seconds

For connection to an external Epson® compatible sockets. B Test configuration data. Phase A breaks:
Br eak1 B r e a k2
parallel printer. C Selected test limits. Ms hut 0.0000 M s h u t 0.0000
LANGUAGES Mo pen 33.300 M o p e n 33.200
RS232: D Analog channel labels. Ro pen 38.600 R o p e n 38.700
Menu selectable from:
For communications to a PC or modem. E Event contacts. Phase B breaks:
English, French, German, Spanish or Italian. Br eak1 B r e a k2

Expansion Unit: F Breaker contacts. Ms


Mo
hut 0.0000
pen 33.300
M
M
s
o
h
p
u
e
t 0.0000
n 33.300
O
Ro pen 38.800 R o p e n 38.800
For connecting an additional 8 analog channels (AC or PHYSICAL DIMENSIONS G Coil current profile.
Phase C breaks:
DC input) and 8 event inputs. 461mm (W) x 347mm (D) x 209mm (H). H Analog channel representing the mechanism travel Br eak1 B r e a k2
Ms hut 0.0000 M s h u t 0.0000
Weight: curve. Mo pen 33.300 M o p e n 33.300
Ro pen 38.800 R o p e n 38.700
Choose Recorder & Command Dialog 15kg. J Mechanism overtravel.
Whilst every effort is made to ensure information is correct, the specification may change
due to continuous product development. K Mechanism rebound.
A powerful test system that is easy to use . . . with results anyone can understand
S P E C I F I C AT I O N MEMORY SAMPLE PRINTOUT L Maximum coil currents recorded.
Sizes: M A “Warning !” will appear beside any test result that
INPUTS
256kbytes, 1Mbyte or 4Mbytes Static RAM. is
Contact Inputs:
(The use of data compression allows approximately 10s outside the test limits set in the “Test parameter
Up to four breaks per phase, each break can consist of HATHAWAY SYSTEMS LTD
of recorded data to be stored per 1Mbyte of memory, at C.B.T.400
limits”.
one Main and one Resistor break in parallel. It is not H.V. CIRCUIT BREAKER TEST SYSTEM
a sample rate of 10kHz). N Measurements taken from the mechanism travel
necessary to disconnect Resistor or Main contacts. Record: 3
Max Record Lengths: curve.
Resistor contact range: S t a t i o n a N me : B O UCHER ROAD
256kbytes:- 10kHz - 500ms C I R C U I T A N ME : A P OLLO
29ohms - 10kohms B R E A K E R A N ME : S . BELFAST
A
1kHz - 5s B R E A K E R O N . : 1 4 55
Timing Accuracy: O p e r a t o r I D : G R AEME EWART
100Hz - 50s
100µs D a t e and time : 1 0 : 53:26 27/06/96

EVENTS
AUXILIARY
BREAKS

COIL CURRENTS

ANALOGUES
1 or 4Mbytes:- 10kHz - 2s O p e r a tion : O p e n
Analog Inputs: T r i g g er : C o i l current
1kHz - 20s M a c h i ne ID : C B T -400-95-01
2 channels dedicated for Open and Close coil currents. S e t u p name : 1 2
100Hz - 200s

A1
A2

B1
B2

C1
C2

OI

A3
4 or 6 user configurable channels for measuring S a m p le Ra te : 1 0 k Hz E
R e s i stor range : l o w
mechanism travel and velocity, station battery voltage, TRIGGERING T r a v el Un its : m e t ric
T r a v el Ch 3-Ch8 : 1 0 0 000
contact resistance, etc. Start Trigger: O p e n coil range : 7 . 5 A
C l o s e coi l range : 7 . 5 A
B
Expandable to have a further 8 user configurable Internal contactor, Open coil current, Close coil current,
R e c o rd Length : 0 . 1 5 se c s
channels that can be incorporated into the case lid. change in any event status, change in analog status. R e l a y on time : 0 . 0 5 0 s e cs
O p e n / close delay : 0 . 0 0 se c s
Analog Accuracy: C l o s e / open delay : 0 . 0 0 se c s F G H
ISOLATION D e b o unce time : 0 . 0 0 5 s e cs
Better than 1%.
Analog and event inputs, coil initiation outputs: O p e n dat u m A : 2 0 . 0 0 m m
Analog Resolution: O p e n dat u m B : 4 0 . 0 0 m m
2.5kVac channel to channel and channel to earth. C l o s e da t u m A : 0 . 0 0 0 m m
12 bits. C l o s e da t u m B : 0 . 0 0 0 m m

Event Inputs: ELECTRICAL INTERFERENCE Test p a r ameter limits


P a r ameter M i n M a x U n its
4 channels user selectable for 110V or 220Vdc nominal. High voltage impulse: M a x open current : 2 . 0 0 0 3 . 0 0 0 A m ps
M a x close current : 2 . 0 0 0 3 . 0 0 0 A m ps
Expandable to have a further 8 user selectable channels IEC 255.4 withstand. W i p e : 7 . 5 0 0 8 . 5 0 0 m m J
S t r oke : 5 5 . 0 0 6 5 . 0 0 m m
that can be incorporated into the case lid. O v e r travel
Surge withstand: R e b ound
:
:
4
2
.
.
0
0
0
0
0
0
5
3
.
.
0
0
0
0
0
0
m
m
m
m C K
O p e n datum veloci t y : 2 . 0 0 0 3 . 0 0 0 m / s
IEC 255.4, 2.5kV 1MHz. C l o se datum veloc i ty : 2 . 0 0 0 3 . 0 0 0 m / s
RECORDING L a s t touch veloci t y : 1 . 0 0 0 2 . 0 0 0 m / s
F i r st part veloci t y : 0 . 5 0 0 1 . 0 0 0 m / s
Sample Rates: POWER SUPPLY
10kHz, 1kHz or 100Hz, user selectable. 85 - 264Vac, 120 - 370Vdc L M
C hannel information
N ame Label Zero FSD Units
OUTPUTS PRINTER A 1 Open current 0 7.5 Amps Coil currents
A 3 TRAVEL A 0.000 100.0 mm D Max open current : 3.978 Amps Warning !!!
Coil Initiation: Internal: Velocity full scale: 3.296 m/s Travel c h annel An 3 (Phase A)
Voltage free contactors 250Vdc, 25A. Wi p e : 8.913mm Warning !!!
Thermal 112mm - 8 dots per mm. Time spacing: 10 msecs
St r o ke : 61.09mm
Alarm Output: Ov e r travel : 4.371mm
External: Re b o und : 2.979mm
Ac t u al open datum A : 19.92mm
N
Rating 110Vdc, 0.5A. Epson® compatible parallel printer. Ac t u al open datum B : 39.92mm
Op e n datum velocity : 2.222 m/s
Remote Start: Fi r s t part velocity : 0.888 m/s
For use with hand-held trigger switch. CONNECTIONS
Printer Port All breaker connections are terminated to 4mm safety A Test identification data. All times in milli seconds

For connection to an external Epson® compatible sockets. B Test configuration data. Phase A breaks:
Br eak1 B r e a k2
parallel printer. C Selected test limits. Ms hut 0.0000 M s h u t 0.0000
LANGUAGES Mo pen 33.300 M o p e n 33.200
RS232: D Analog channel labels. Ro pen 38.600 R o p e n 38.700
Menu selectable from:
For communications to a PC or modem. E Event contacts. Phase B breaks:
English, French, German, Spanish or Italian. Br eak1 B r e a k2

Expansion Unit: F Breaker contacts. Ms


Mo
hut 0.0000
pen 33.300
M
M
s
o
h
p
u
e
t 0.0000
n 33.300
O
Ro pen 38.800 R o p e n 38.800
For connecting an additional 8 analog channels (AC or PHYSICAL DIMENSIONS G Coil current profile.
Phase C breaks:
DC input) and 8 event inputs. 461mm (W) x 347mm (D) x 209mm (H). H Analog channel representing the mechanism travel Br eak1 B r e a k2
Ms hut 0.0000 M s h u t 0.0000
Weight: curve. Mo pen 33.300 M o p e n 33.300
Ro pen 38.800 R o p e n 38.700
Choose Recorder & Command Dialog 15kg. J Mechanism overtravel.
Whilst every effort is made to ensure information is correct, the specification may change
due to continuous product development. K Mechanism rebound.
The CBT-400, easily satisfying the needs of maintenance and testing programmes
PA N E L L AYO U T ACCESSORIES R E P L AY ™ S O F T W A R E A N D D ATA B A S E

A protective carrying case and cable carrying roll is A Windows™ based Replay™ software package is available
available for the safe transportation of the CBT-400. for the Hathaway range of Circuit Breaker test and
Integral printer and monitoring products. This package allows test records and
paper roll. Printer uses results to be analyzed in detail and archived on a PC.
a fixed thermal head Records can be transferred to the CBT-400 via a modem or
to give high reliability. a direct RS232 connection.
Additional 8 event The Replay™ software allows single records to be viewed, or
inputs (optional). Buzzer giving audible multiple records may be overlayed to show variances in
warning of breaker results. Cursors can be moved to any position on a record,
test. where measurements can be obtained.
Also included in this package is a Remote Configuration
Power input, program that enables the set up parameters and test limits
Additional 8 analog
85 - 264Vac, to be stored and transferred to the CBT-400.
inputs (optional).
120 - 370Vdc.
Protective Case Travel
Test lead outputs to and Cable Carrying Roll Transducer
Open and Close
circuit breaker contact
initiation outputs to A comprehensive range of linear and rotary travel
heads. Two cables per
breaker under test. Dry transducers are available for measuring circuit breaker
phase each allowing 4
contacts rated for mechanism travel and velocity.
breaks per phase to be
250V, 25A controlled
monitored.
from integral keypad. The Micro-Ohm Interface allows a “dynamic” resistance
Parking sockets profile of the circuit breaker to be recorded. This can be
Event inputs for provided for analysed using the Windows™ based Replay™ software
monitoring energized prevention of package and measurements of both main and arcing
contacts, e.g., breaker unintended breaker contacts can be made by injecting a high dc current,
auxiliary contacts. operation. typically 1000A, from an external battery. The Micro-Ohm
Selectable 110V or Interface calculates the resistance of the contacts
220Vdc nominal. RS232 serial output throughout a Close-Open sequence and generates an
port to download output for the CBT-400 where a resistance trace is Replay™ Station
Power outputs for recorded test data to a recorded. The Micro-Ohm Interface has an added safety
resistive travel computer system for feature which will break the current flow in the event of the The program can also export test results to a database that
transducer. 2.5Vdc. storage and off-line circuit breaker failing to open. enables the sorting and searching of records, generation of
analysis. customised reports and generation of works orders for
preparing breaker maintenance schedules. The database
Analog inputs, 2.5Vdc
package used in this application is commercially available
sensitivity. Typically External printer output
and highly flexible. It can be easily customised to provide
used for mechanism for an Epson®
information in any customer required format.
travel and velocity, compatible printer.
contact resistance or
Other Hathaway products that can be used with the above
battery voltage External horn output.
Liquid crystal display software packages are:
measurements.
with contrast control ■ CBT-2 Off line breaker tester.
Test initiation input for
and backlight. ■ CBT-4 Off line breaker tester.
remote handheld
■ CBT-200 Off line breaker tester.
switch.
System control keypad Manual breaker ■ RTR-84 Periodic On line breaker tester.
with alpha-numerical operation with safety ■ BCM Permanent On line breaker condition
capabilities. lock. Micro-Ohm Interface monitor.
The CBT-400, easily satisfying the needs of maintenance and testing programmes
PA N E L L AYO U T ACCESSORIES R E P L AY ™ S O F T W A R E A N D D ATA B A S E

A protective carrying case and cable carrying roll is A Windows™ based Replay™ software package is available
available for the safe transportation of the CBT-400. for the Hathaway range of Circuit Breaker test and
Integral printer and monitoring products. This package allows test records and
paper roll. Printer uses results to be analyzed in detail and archived on a PC.
a fixed thermal head Records can be transferred to the CBT-400 via a modem or
to give high reliability. a direct RS232 connection.
Additional 8 event The Replay™ software allows single records to be viewed, or
inputs (optional). Buzzer giving audible multiple records may be overlayed to show variances in
warning of breaker results. Cursors can be moved to any position on a record,
test. where measurements can be obtained.
Also included in this package is a Remote Configuration
Power input, program that enables the set up parameters and test limits
Additional 8 analog
85 - 264Vac, to be stored and transferred to the CBT-400.
inputs (optional).
120 - 370Vdc.
Protective Case Travel
Test lead outputs to and Cable Carrying Roll Transducer
Open and Close
circuit breaker contact
initiation outputs to A comprehensive range of linear and rotary travel
heads. Two cables per
breaker under test. Dry transducers are available for measuring circuit breaker
phase each allowing 4
contacts rated for mechanism travel and velocity.
breaks per phase to be
250V, 25A controlled
monitored.
from integral keypad. The Micro-Ohm Interface allows a “dynamic” resistance
Parking sockets profile of the circuit breaker to be recorded. This can be
Event inputs for provided for analysed using the Windows™ based Replay™ software
monitoring energized prevention of package and measurements of both main and arcing
contacts, e.g., breaker unintended breaker contacts can be made by injecting a high dc current,
auxiliary contacts. operation. typically 1000A, from an external battery. The Micro-Ohm
Selectable 110V or Interface calculates the resistance of the contacts
220Vdc nominal. RS232 serial output throughout a Close-Open sequence and generates an
port to download output for the CBT-400 where a resistance trace is Replay™ Station
Power outputs for recorded test data to a recorded. The Micro-Ohm Interface has an added safety
resistive travel computer system for feature which will break the current flow in the event of the The program can also export test results to a database that
transducer. 2.5Vdc. storage and off-line circuit breaker failing to open. enables the sorting and searching of records, generation of
analysis. customised reports and generation of works orders for
preparing breaker maintenance schedules. The database
Analog inputs, 2.5Vdc
package used in this application is commercially available
sensitivity. Typically External printer output
and highly flexible. It can be easily customised to provide
used for mechanism for an Epson®
information in any customer required format.
travel and velocity, compatible printer.
contact resistance or
Other Hathaway products that can be used with the above
battery voltage External horn output.
Liquid crystal display software packages are:
measurements.
with contrast control ■ CBT-2 Off line breaker tester.
Test initiation input for
and backlight. ■ CBT-4 Off line breaker tester.
remote handheld
■ CBT-200 Off line breaker tester.
switch.
System control keypad Manual breaker ■ RTR-84 Periodic On line breaker tester.
with alpha-numerical operation with safety ■ BCM Permanent On line breaker condition
capabilities. lock. Micro-Ohm Interface monitor.
15 Wildflower Way 8228 Park Meadows Drive
Belfast Littleton
BT12 6TA Colorado 80124
Northern Ireland U.S.A.
Telephone: +44 28 9022 5200 Telephone: +1 303 799 8200
Fax: +44 28 9022 5225 Fax: +1 303 799 8880
Internet: www.hathaway-systems.com e-mail: info@hathawaycorp.com

You might also like