■■ Hythrust micro tunnelling and jacking pipes are ■■ Hythrust Jacking Pipes are designed to resist an
manufactured with spun reinforced concrete and installation axial load. This axial load is related to the
incorporate industrial grade fibreglass or metal jointing frictional resistance forces that occur during thrusting
bands with natural rubber sealing rings. operations.
■■ The 375, 450 and 600 diameter jacking pipes incorporate ■■ Determining factors vary according to thrust length, pipe
a 25 mm sacrificial layer for additional durability. diameter and in-situ material.
■■ A sacrificial layer is available in the 900, 1200 and 1300 ■■ Produced to nominal axial loads, but can be modified to
jacking pipes upon request. allow for further strength increases.
Microsilica, Hydura, or Bicrete concrete is available for Each pipe has been designed to allow safe angular
D1.3 Hythrust Jacking Pipe System | DRAINAGE | PG 2
■■ ■■
applications requiring additional durability in aggressive deflection during installation by using a medium density
soil conditions. fibreboard (MDF) joint packer.
■■ Rubber skid rings are manufactured to AS 1646:2001.
■■ Fibreglass seal couplings are manufactured to AS 2634 Joint Sealing
from a premium grade isophthalic polyester resin which
■■ A hydraulic seal is formed with a purpose-made rubber
has proven performance in immersion conditions.
skid ring compressed between a loose jointing band and
■■ Stainless Steel 316 seal couplings are used for high the concrete spigot end.
corrosion resistance.
■■ Maximum final pipeline deflection should not exceed 0.5º
to ensure the joint is sealed.
Handling
■■ The sealed joint is capable of sealing to ten metres
■■ All Hythrust Jacking Pipes are fitted with Swiftlifts for internal pressure.
handling into the jacking pit.
Testing
Installation
■■ On site pressure testing of installed concrete pipelines is
■■ Easy onsite jointing using double spigot rubber skid ring normally required for foul sewers only. This test typically
and jointing band (refer to Figure 1.) follows the requirements set out in NZS 4452, with
water tests being the only accurate way to determine any
■■ Installation can be from a very small pit with minimum
leakage.
site disturbance, when using short component lengths.
Note: For further information on Hythrust pipe dimensions, vertical and
■■ Direct installation method minimises excavation around axial load options, and joint options, contact the Hynds Technical Services
the pipe, reducing vertical earth loads above the pipeline. Department.
Load Conditions
Rubber Ring
Diameters of Pipes Packer Details
Details
Hynds Codes Nominal Nominal Internal Outside Wall Length Weight Recommended Maximum Product No.
Dia. Length Dia. Dia. Thickness (mm) (kg) Joint Packer Packer Code per
(mm) (mm) (mm) (mm) (mm) Thickness (mm) Dia (mm) Pipe
Microtunneling Pipe
03752000JACWHYS 375 2000 375 535 80 1991 595 9 499 R0375SKIDH 2
0450.1JACWHYS 450 1000 450 610 80 991 347 9 574 R0450SKIDH 2
04502000JACWHYS 450 2000 450 610 80 1991 695 9 574 R0450SKIDH 2
Jacking Pipes
06002000JACZHYS 600 2000 622 782 80 1991 941 9 746 R0600SKIDH 2
06002000JACWHYS 600 2000 622 782 80 1991 952 9 746 R0600SKIDH 2
0750JACZ Refer to D1.10 Hynds Skid Ring Joint Jacking Pipe System
09002000JACZHYS 900 2000 900 1080 90 1991 1497 9 1045 R0900SKIDH 2
09002000JACWHYS 900 2000 880 1080 100 1991 1650 9 1045 R0900SKIDH 2
1050JACZ Refer to D1.10 Hynds Skid Ring Joint Jacking Pipe System
1200JACZ 1200 2600 1110 1310 100 2600 2669 12 1272 R1200SKIDH 2
1200JACW 1200 2600 1080 1310 115 2600 3228 12 1272 R1200SKIDH 2
1300JACZ 1300 2400 1284 1524 120 2400 3434 12 1485 R1300SKIDI 2
Notes: Other pipe sizes may be designed on request with either sealed or unsealed joints.
Please also refer to product sheet D1.4 & D1.10 for details of other pipes which may be suitable for jacking applications.