Professional Documents
Culture Documents
Subsidiary Company:
USA
USA
Contents
13 Section 5 FACILITIES
NDT Phils., Inspection Services Corp. (NDTPISC) was founded by the energetic and
enterprising couple, Mr. Jerson C. Cruz and Ms. Olimar “Olive” D. Estrella-Cruz, in Cebu
City, Philippines on September 27, 1995. The company was engaged in specialized
Inspection Services including Non-Destructive Testing System, Quality Assurance and
Quality Control Services and General Engineering.
After a short while, the company moved its operations to Metro Manila to be close to the
big industrial and commercial firms, which are its main clients. In 1998, NDTPISC
increased its authorized capital to Ten (10) Million Pesos and acquired advanced
inspection and testing equipment. The company also hired more qualified and
experienced engineers and technicians to efficiently serve its fast growing clientele. The
management decided to move to its present location at JERO Bldg., 19 Jerusalem
Multinational Village, Parañaque City to effectively serve the needs of its customers.
The management is well aware of the technological advancement in the field of inspection and testing which
continuously seeks to improve the quality of service it provides its customers by
utilizing modern inspection and test equipment and techniques. To bolster its quest
for world class quality inspection and testing capability, NDTPISC was ISO
9001:2008 certified.
In the year 2000 NDTPI increased its capital to Forty (40) million and specializes
in Tank Inspection adding more personnel and equipment to its present particularly
the MAGNETIC FLUX LEAKAGE [FloormapVS2 MFL Floor Scanner] and REMOTE
ACCESS ULTRASONIC CRAWLER SCORPION DCP & other state of the art
C.R.: 2051037168 License: 3929-3 equipment.
Please visit our website @ www.ndtphils.com, email us at ndtphils@ndtphils.com for your queries.
Jerrie Technical & Testing Establishment (JTTE) acquired its Registration as Sole Proprietorship with
Registration Number 2051037168 on April 24, 2008 at the Commercial Registration Office of Dammam City,
Kingdom of Saudi Arabia. Its business activities include but not limited to the execution of services in inspection -
and testing related to industrial firms, oil and gas facilities, power plant, trading & contracting and implementation
of electromechanical works such as Non-Destructive Testing and Industrial Inspection.
The owner of TTE spent most of his years working in Middle East for almost twenty (20) years after which, he
decided to establish an Inspection company in the Philippines and now aiming as well to be a popular inspection
company in the Middle East.
Based on various experiences, he gained confidence from his local inspection company; there is no doubt that
JTTE will build its reputation also in the Middle East especially in Saudi Arabia.
His also over thirty (30) years’ work experience was specialized in project engineering, construction, NDE
inspection, major design and maintenance 'of oil refinery, petroleum terminal, liquefied petroleum gas (LPG) bulk
plant and refilling plant & tank farm facilities, aircraft fueling facilities, bulk plant & lube oil blending plant.
Major work experiences are in piping system inside plant area for all/gas, compressed
air, chemical & utility piping, erection, Inspection of Truck Trailer Tanks & refurbishment
of large oil storage tanks such as floating & cone roof type, LPG tank,
011 water/drainage & API separation system, truck loading, unloading and transfer
product pump.
Firefighting facilities and emergency shutdown system for oil Refinery & Bulk Plants.
Well versed with various international standards and codes such as API-650, API-653,
API-2610, NFPA, ASME Codes, ASTM, ANSI 631.3 & 63i.4, AWS and ASNT-SNT-TC-1A
(all aspects) Saudi Aramco Engineering and Material standard and Petroleum/'Power
Plant Engineering Standard.
Please visit our website @ www.tte-ksa.com, email us at ttesnde.saudi@yahoo.com for your queries.
1|Page
SECTION 1 INTRODUCTION
The COMPANY
NDT-Phils., Inspection Services Corp. has firmly and steadily achieved its reputation for
the services of Non-Destructive Testing (NDT) and as Third-Party Inspection Company
expanding throughout the Philippines.
On the onset, “NDTPI” for short with fully organized management and technical team
both internal & external operations demonstrate the skills and abilities by a
combination of team building process amongst its workforce and experience resulted
in a timely success in its business endeavors.
To date, NDTPI/JTTE., through innovative ways was inspired by its success stories in the
Philippines and Saudi Arabia through combination of the latest technology and technical
skills has established alliances in Bahrain, Qatar, Libya, Yemen and Iraq. Our continuing
expansion demonstrates our capabilities to serve as one of the premiere NDT
organization you can depend within the industry.
Lastly, our associations and affiliations will continue to evolve where we can extend our
hands-on expertise in the field of Engineering & Industrial Inspection and Non
Destructive Testing (Advance & Conventional NDT’s) with our team of Engineers,
Inspectors and Technicians who are fully dedicated and committed professionally to
deliver the highest standard of services.
“Our Quality work and Integrity reflects the face value of your facility”
SECTION 1 NDTPI IN A CAPSULE
NDTPI in a Capsule
NDT-Phils., Inspection Services Corp. holds a record of quality and service excellence that
enabled it to be regarded as a reliable resource for Non-Destructive Testing of
Advanced and Conventional NDT, Third Party Inspection & Industrial Engineering &
Inspection services.
Behind NDTPISC’s expertise are its highly trained and experienced engineers, NDE
Inspection engineers, inspectors and technicians, practicing uncompromising quality
standards, and with years of extensive exposure to domestic and international projects.
Services Offered:
❑ Non- Destructive Testing (NDT) ❑ Industrial Inspection
Advanced NDT ▪ Welding inspection
o Low Frequency Electromagnetic Technique(LFET) ▪ Welders Qualification Test (WQT)
o Phased Array Ultrasonic Testing (PAUT) ▪ Quality Assurance & Quality Control (QA/QC)
o Time of Flight Diffraction (TOFD) ▪ Weld Engineering & Maintenance Inspection
o Magnetic Flux Leakage Testing (MFLT) ▪ Vendors and Surveillance Inspection
o Eddy Current Testing (ECT) ▪ Third Party Inspection (TPI)
o Remote Field Electromagnetic Testing (RFET) ▪ Supply Certified Inspectors
o Internal Rotating Inspection System (IRIS) ▪ Positive Material Identification (PMI)
o Magnetic Flux Leakage Testing (MFLT- Tubes) ▪ Sponge Jet Blasting
▪ Coating/Holiday Inspection
Conventional NDT
3|Page
SECTION 2 ORGANIZATIONAL CHART
4|Page
MANPOWER RESOURCES /
SECTION 3
CERTIFICATIONS
API
API 653,510 CERT. 25567 & NACE 5713
Quek Chew Hai NACE
Senior Corrosion Technologist
Karl Hedrick P. Sabado NDTPISC-ASNT Level II Cert. No. 033 ASNT In-House
Allan Edward E. Galoso NDTPISC-ASNT Level II Cert. No. 026 ASNT In-House
King Kervy D. Revilla NDTPISC-ASNT Level II Cert. No. 032 ASNT In-House
Jose Angelo J. Maban NDTPISC-ASNT Level II Cert. No. 042 ASNT In-House
Romeo A. Lacasandile Jr. NDTPISC-ASNT Level II Cert. No. 050 ASNT In-House
Joshua Kristofferson E. Cruz NDTPISC-ASNT Level II Cert. No. 051 ASNT In-House
Rodolfo Johans M. Barrameda NDTPISC-ASNT Level II Cert. No. 052 ASNT In-House
5|Page
MANPOWER RESOURCES /
SECTION 3
CERTIFICATIONS
7|Page
MANPOWER RESOURCES /
SECTION 3
CERTIFICATIONS
8|Page
SECTION 4 EQUIPMENT PRESENTATION
FLOORMAPVS2i
The FloormapVS2i floor scanner is a MFL system designed to detect and size under
floor corrosion for above ground storage tanks. The FloormapVS2i is the latest
version of the bestselling magnetic flux leakage (MFL) floor scanner and now comes
with up-graded magnets to improve defect detectability and sizing on thicker
materials, faster data capture with a custom designed micro controller and all new
software. The VS2i contains significant improvements in terms of defect positioning,
electronic data processing and software manipulation.
SCORPION 2
The Scorpion 2 dry-coupled remote-access ultrasonic crawler bring major efficiency and
data improvements to tank shell inspections and other structures such as vessels and
offshore installations. API 650/653 compliant, this powerful duo is the perfect solution for
in-service inspection of your assets.
USM VISION
USM Vision offers a complete digital inspection workflow, from the inspection plan
creation to the data sharing that can be done wirelessly. USM Vision has been
developed to meet the market need to transition from radiographic to ultrasonic
weld inspection according to the international codes and standards through:
Optimizing the use of specialized inspection personnel
Increasing productivity i.e. lean manufacturing/construction
Reducing the current weld inspection radiographic constraints:
radiation, consumables and chemical waste management
Simplifying the ultrasonic weld inspection process
This manually operated belt scanner is the ultimate scanning aid for phased array
inspection of circumferential welds in small bore pipework. This lightweight and low-
profile scanner is extremely simple to set up and use for weld testing on pipe sizes
from 0.5” to 4”. The Bracelet is compatible with industry standard miniature phased
array transducers and is designed to be used in areas of limited access with a
scanner height of 13mm.
OMNISCAN MX2
The OmniScan MX2 offers a high acquisition rate and new powerful software
features for efficient manual and automated inspection performance—all in a
portable, modular instrument.
9|Page
EPOCH 600
The EPOCH 600 Digital Ultrasonic Flaw Detector combines Olympus' industry
leading conventional flaw detection capabilities with the efficiency of a highly
portable, intuitive instrument. The EPOCH 600 flaw detector's blend of efficient
menus and direct access keys allows you to take advantage of the highest quality
flaw detection platform with exceptional ease of use.
The large, full VGA transflective display combined with our patent-pending digital
high dynamic range receiver provides a stable, striking A-scan representation in
any lighting condition. Available in two hardware configurations, the EPOCH 600
offers you the choice to adjust parameters with a knob or with a navigation area
on the keypad. The EPOCH 600 is designed to meet the requirements of EN12668-
1 and allows a full range of standard and optional flaw detection features. The
rugged, ergonomic design allows use in nearly any inspection environment, while
the flexible PerfectSquare™ pulser and digital filtering capabilities can tackle nearly
any application.
27MG UTG
45MG UTG
In its basic configuration the 45MG is a simple and straightforward gage that
requires minimal operator training to tackle most common thickness gaging
applications. With additional optional software options and transducers
however, the 45MG can become significantly more advanced and take on
applications well beyond that of a typical entry-level gage. Furthermore, most
options are available individually at the time of purchase or can be added in the
future as your needs change.
10 | P a g e
EPOCH 4 FLAW DETECTOR
The latest version of the USM 35X portable ultrasonic flaw detector from GE's
Inspection Technologies business, is now totally protected against the ingress
of dust and high pressure jets of water to IP 66 and contains new software
which allows its operation to Japanese weld inspection standards.
Model 880 series source projectors are used for industrial applications of
gamma radiography to inspect materials and structures in the density range of
approximately 2.71 g/cm3 through 8.53 g/cm3.
SENTINELTM Model 880 Delta, 880 Elite and 880 Omega source projectors are
portable, lightweight and compact industrial radiographic exposure devices.
The patented device body consists of a titanium ‘S’ tube and cast depleted
uranium (DU) shield contained within a 300series stainless steel tube with
stainless steel discs welded at each end forming a cylinder-shaped housing. The
discs are recessed to provide protection for the rear mounted locking
mechanism and front mounted outlet port.
The B-300 Contour Probe is a lightweight (7½ pounds) Magnetic Inspection Yoke
designed to perform magnetic particle inspections quickly and reliably. As with
the other probes, the B-300 has fully adjustable legs which allow the strong AC
field to be applied directly to the precise area to be inspected, regardless of part
size or mass.
The vacuum boxes have calibrated pressure relief valves fitted as standard. Also
the boxes cannot be damaged by drawing too great a vacuum.
11 | P a g e
BAC310 AC POWER SUPPLY
The BAC310 battery operated Inverter Power Supply is a totally portable, stand-
alone power source. It is designed to operate any of the Parker.
SPECTROLINE EK-3000 EAGLE EYE ULTRAVIOLET LED HELMET LIGHT
New from Spectronics. Two ultra-high-intensity UV-A LED’s permit hands-free
pre-paint inspection of structures for organic compounds such as oil, which glow
under black light and can cause coating failure. The EK-3000 UV Light is also ideal
for magnetic particle or liquid penetrant inspection of corrosion and
discontinuities in steel structures. The integrated three-LED white light assembly
allows for regular illumination in dark areas.
DMS 2
The DMS 2 has retained the user preferred features of its predecessor, the
popular DMS, and added expanded measurement capabilities to solve remaining
wall thickness applications. All information (large thickness digits, A-Scan, B-Scan,
and data files) is clearly displayed on a large high resolution (1/4 VGA) LCD screen
that is easily read in direct sunlight. The DMS 2 is compact, easy-to-use, and like
all Krautkramer D-Meters is built-to-last in a custom molded, gasket sealed, high-
impact resistant housing with a rubber protective case to withstand use in harsh
industrial environments.
The DELTA Professional Incorporates everything you need in a handheld XRF with
state-of-the-art innovations and a rugged design.
The handheld Vanta XRF analyzers are built to be tough and have a durable design,
making them resistant to damage for greater uptime and a lower cost of
ownership.
The Vanta series comes with smart navigation and configurable software, which
makes them easy to use with minimum training for high throughput and a quick
return on investment. With advanced and proprietary AxonTM technology, the
Vanta analyzers provide the clients with accurate results and help to enhance
productivity regardless of the working conditions or the environment.
12 | P a g e
SECTION 5 FACILITIES
MAIN OFFICE:
JERO BLDG., #19 JERUSALEM ST., MULTINATIONAL VILLAGE,
1708 PARAÑAQUE CITY, PHILIPPINES
13 | P a g e
SECTION 5 FACILITIES
NDTPISC OFFICE
CONFERENCE ENGINEERING
WAREHOUSE
14 | P a g e
QUALITY MANAGEMENT SYSTEM /
SECTION 6
ENGINEERING WORK EXECUTION
ENGINEERING INSPECTION
An important function that shop inspection (stationary and rotary equipment), site inspection and pre -
shipment inspection can be carried out satisfactorily only by trusted and experienced Inspectors whose
integrity and competence are beyond doubt. The reliability and overall normal performance of inspection
jobs are products of careful selection of the Inspection Company possessing an excellent and untarnished
reputation and likewise, the effective intervention of a cohesive team of inspectors.
SHUTDOWN INSPECTION
Is conducted periodically enabling industrial plants, factories and refineries etc., to determine the
existing plant conditions in order to carry out the necessary preventive and corrective maintenance works on
various rotating and stationary equipment, buildings, piping’s, etc., through the performance of effective
visual inspection, accurate measurement of vessels and processes pipelines wall thickness, corrosion/erosion
surveys of vessels and lines, blockage and silting detection and functional checks of moving components.
BUSINESS QUALIFICATION
A process by which job applicants undergo comprehensive and rigid theoretical and practical
examinations to determine the level of skills, suitability, limitations and to improve techniques that would
ensure high level of actual job performance. The qualification test aims to stimulate the actual job conditions
giving emphasis to the type of equipment operation, properties and dimensions of materials and the required
process.
NON-DESTRUCTIVE EXAMINATION
INDUSTRIAL RADIOGRAPHY
Radiography basically is the study of shadow picture; it reveals the internal structure of an object when
exposed to illumination of radiation. It is one of the most reliable Non-Destructive testing methods applied
to detect faults in welding, casting, and in the verification of internal corrosion on piping, wall of vessel and
also used to trace faults in valve internals when “passing” is a problem.
Radiographs are permanent positive record and the object examined remains intact. Tested parts can
be returned to service if findings do not require rectifications, immediate repair can be done without
missing any part of “for repair” areas because radiographs [processed industrial film] reveal the exact
location of faults.
This method in NDT is very effective in tracing and analyzing metal losses in vessel, tank, pipe and other
heavy walls suspected of being internally corroded or have thinning areas or defective weld which our naked
eyes cannot visualize. These areas might be very critical and might require immediate replacement or repairs
to ensure integrity of equipment material and the equipment itself.
15 | P a g e
QUALITY MANAGEMENT SYSTEM /
SECTION 6
ENGINEERING WORK EXECUTION
LOW FREQUENCY ELECTROMAGNETIC TECHNIQUE (LFET)
The “Low Frequency Electromagnetic Technique” (LFET) is an effective means to inspect tubing and piping
from the outside diameter (O.D.), as well as pressure vessels. It detects and quantifies I.D. and O.D. defects
in ferrous and non-ferrous materials. This technique is a dry non-contact method. The scanners contain no
magnets. It is forgiving to uniform surface scale. The technology is adaptable to different applications, which
allows the inspection of different diameters of tubing, the inspection of bends, and the inspection of tubes
in space- constricted areas. The system collects 1200 samples per second. It is lightweight, modular, and uses
digital signal processing electronics while being operated with a laptop computer. The results are displayed
in real-time with high-resolution color graphics with 3D display. Inspections are able to find pitting, general
wall losses, caustic and phosphate gouging, corrosion cells, hydrogen damage, Microbiologically Influenced
Corrosion attack (MIC attack), Flow Accelerated Corrosion (FAC), cracking, erosion, and manufacturing
defects. The technology is able to test through non-magnetic coatings up to ¼” thick. By adjusting the
frequency level, magnetic and non-magnetic metals can be inspected. A general rule is the lower the test
frequency, the greater the depth for signal penetration.
16 | P a g e
QUALITY MANAGEMENT SYSTEM /
SECTION 6
ENGINEERING WORK EXECUTION
MAGNETIC FLUX TEAKAGE TEST (MFLT)
Used to evaluate the underside condition of plate on storage tank floors. The FloormapVS2i Silverwing
(UK) Ltd's, is latest version of the best-selling MFL floor scanner and now comes with up- graded magnets
to improve defect detectability and sizing on thicker materials, faster data capture with a custom designed
micro controller and all new software. The VS2i contains significant improvements in terms of defect
positioning, electronic data processing and software manipulation.
HOLIDAY TESTING
High voltage Holiday Detectors are, in principle, insulation testers used to indicate a fault in the non-
conductive coating under test by generating a spark which triggers audible and visual alarm.
Flaws such as pinholes, air bubbles, inclusions, cracks, voids and thin spots can occur in a wide range
of coating material used in industry. A pinhole although small can cause extreme damage by permitting
corrosive materials to reach the base material, Lack of continuity of coating causes premature failure,
which can be very expensive to repair and lead to possible stoppage in production. In certain
circumstances, an air pocket can represent a substantial portion of the total thickness, and thus cause a
weak point, even though the coating is continuous.
VACUUM TESTING
Vacuum testing requires proper surface preparation. The need to clean the surface to be inspected
free from scales that are capable of plugging small holes is of utmost importance. Otherwise, testing will
not yield good results.
In the performance of the test, the surface is first coated with films of soapy solution. Then the open
side of the vacuum box is placed on top of the test area. A partial vacuum of 21 kPa (3 lbf/in. 2/6 in. Hg) to
35kPa (5 lbf/in. 2/10 in Hg) is maintained inside the box. Leaks can simply be located by the appearance of
continuous bubbles at any point on the test area. Observation is made at the top glass of the box.
The effectivity of this method is enough to locate even hairline cracks. Care should be exercised that
heavy soapy solution is not applied. It usually gives false indication. The main disadvantage of this method
is its difficulty to apply on non-flat surfaces. More so, in large tanks, it is considered to be time-consuming
and labor intensive.
Our range of activities for oil & gas, marine, wharves & construction are as
Follows:
Feasibility and economic studies
Site Investigation
CPS - Planning and project designs (re-habilitation, maintenance & new construction.
Project management
Cost estimates, specifications and bill of materials
Material manufacturer and supply and CPS installation
Installation supervision, commissioning, maintenance and monitoring
Consultancy and specialist advice
General engineering and fabrication
17 | P a g e
QUALITY MANAGEMENT SYSTEM /
SECTION 6
ENGINEERING WORK EXECUTION
POSITIVE METAL IDENTIFICATION (PMI)
Nowadays as the features of specific materials increasingly become better utilized and fitness for purpose
is designed, guarantee of material specifications is very important. With Positive Metal Identification (PMI)
the alloy composition and thus, the identity of materials can be determined. When the material certificate
is missing or unclear and the costumer wants certainty about the composition of a material, PMI is the
solution.
Positive Metal Identification is particularly used for high-quality metals like stainless steel and high alloy
metals. While engineers push the boundaries of metal capacities to their limits in the design, assurance that
the proper material is used becomes more important.
WELDING CONSULTANCY
Preparation of welding inspection procedure testing based on the specification of the clients compilation
of necessary materials specification data based on standard codes.
COATING INSPECTION
Assessment of coatings in Ferrous-Steel, Stainless-Steel, Aluminum, Concrete, and other materials requiring
coatings, for purposes of determining the required compliance and performance.
18 | P a g e
SECTION 7 SAFETY MANAGEMENT
SAFETY POLICY
NDT-Phils., Inspection Services Corp. [NDTPISC] is totally committed to a policy of prevention, reduction and
elimination of all undesired events that could or do result in loss and to protect the interest of the company and
customer at all times.
To achieve this aim, the company has embarked on a Risk Management and Safety Program which will encomp ass all
sections and areas of our operations.
All employees are required to confirm to all rules of conduct relating to safety and health on the project.
1.1.2. Insubordination
1.1.2.1 Insubordination in respect of carrying out verbal or written instructions or directives issued by
management or supervisory personnel shall be sufficient cause for initiating disciplinary
action in accordance with established company procedures.
19 | P a g e
SECTION 7 SAFETY MANAGEMENT
1.2.1 All injuries shall be reported to an immediate supervisor to ensure that proper and adequate medical
attention is obtained and that any accident involving personal injury is investigated.
1.2.2 All accidents that result in injury to any employee or sub contractor’s employee shall be immediately
reported.
1.2.3 All accidents that result in damage to plant equipment or property shall be immediately reported.
1.2.4 All accidents in which damage was prevented by circumstances or deliberate preventive action shall be
immediately reported to a supervisor. This type of accident is known as a “Near Miss” accident and it is
important that they are reported in order to prevent a similar re-occurrence that could result in a
serious accident.
1.3.1 All NDTPISC employees on the project shall immediately report all unsafe acts or conditions that may
observe to their supervisor so that corrective action can be taken to prevent the risk of injury or
damage.
1.3.2 Situations involving “Imminent Danger” shall be reported to the first supervisor or foreman the
technician can locate.
1.4.1 Unauthorized o p e r a t i o n s o f N D T P I S C m o b i l e l a b o r a t o r y a n d r a d i o g r a p h y
e q u i p m e n t i n c l u d i n g radioactive isotopes, x-rays and accessories are prohibited.
1.4.2 Each certified and qualified ANST SNT-TC-1A employee shall be authorized in writing by the ASNT Level-
III. An in-house course must be rendered prior to authorization to operate NDT equipment. A minimum
of 40 hours seminar for every discipline is required.
1.5.1 It is the responsibility of every NDTPISC employee to familiarize himself with the applicable procedures
that apply to the project. NDTPISC personnel will receive instructions from the project Safety Officer
and their immediate supervisor. Everyone must attend the safety orientation of the customer prior to
commencing to project execution.
1.5.2 NDTPISC Technicians and Engineers will receive instructions from the customer project safety engineer
and their immediate supervisor on what actions to take in case of an emergency. “Do not be afraid of
asking question if you are uncertain it may eventually save your life possibly the lives of your fellow
employees.”
20 | P a g e
SECTION 7 SAFETY MANAGEMENT
1.6 Accidents
1.6.1 In the event of a serious accident on site, where NDTPISC are not directly involved in assisting the
injured, or the rescue team, it is essential that you clear the accident area and access routes to enable
ambulance and medical team and other essential personnel to reach the injured as soon as possible.
1.6.2 NDTPISC personnel must obey all instruction from their supervisor and avoid the temptation to become
an unwanted sightseer.
1.7 Safety Meetings and Information
1.7.1 Safety Meetings
1.7.1.1 Safety meetings shall be held prior to mobilization and on site befor e commencing to
work by NDTPISC supervisor or the team leader in his absence. All NDTPISC employees
are encouraged to participate in this meeting and raise any relevant q uestions about
safety. NDTPISC will provide their employees with safety information regarding
employees particular work task.
1.7.1.2 These meetings are solely intended for safety matters and will not be used to discuss
other work problems or general grievances. Other channels of communication are
available within the established company procedures to deal with these matters.
2.2 Waste materials shall not be permitted to accumulate and shall be placed in approved customer rubbish
containers as soon as practically possible.
2.3 When placing material or equipment or when removing them from demarcated storage areas, avoid disturbing
other stored items.
2.4 Demarcated aisles, walkways and access ways shall be kept clear of loose or surplus materials or equipment at
all times. Do not place materials or equipment against walkways or fences or storage areas, a gap of at least 1
meter must be left between the material and the wall fence.
2.5 All emergency exit and fire escape areas shall be demarcated and kept clear at all times.
2.6 All “No smoking “gas cylinders, and flammable storage areas shall be kept clear of rubbish at all times.
2.7 Electrical cables, welding leads, water, air, and gas hoses shall be placed where they cannot damage and cause
injury.
2.8 Cables, leads and hoses shall be kept clear of all stairs and ladders access.
Spilled oil, grease or other slippery substances in working areas shall be cleaned up immediately cordoned and
sprinkled with enough dirt or sand to absorb the substance and eliminate slipping substance.
21 | P a g e
SECTION 7 SAFETY MANAGEMENT
SAFETY CERTIFICATES
22 | P a g e
SECTION 7 SAFETY MANAGEMENT
23 | P a g e
SECTION 8 REFERENCE STANDARDS/ CODES
REFERENCE DESCRIPTION
ASME I Rules for Construction of power Boilers
ASME II PART A Ferrous Materials Specification
ASME II PART B Non Ferrous Materials Specification
ASME II PART C Specification for Welding Rods, Electrodes & Filler
ASME II PART D Properties
ASME V Non-Destructive Examination
ASME VIII DIV.1, 2 & 3 Rules for Construction of Pressure Vessel
ASME IX Welding & Brazing’s Qualification
ASME B31.1 Power Piping
ASME B31.3b Process Piping
API 510 Pressure Vessel Inspection Code
API 570 Inspection, Repair, Alteration & Rerating
Damage Mechanisms Affecting Fixed Equipment in the
API 571
Refining Industry
API 572 Inspection of Pressure Vessels
Inspection of Atmospheric and Low Pressure Storage
API 575
Tanks
API 576 Inspection of Pressure Relieving Devices
API 577 Welding Inspection and Metallurgy
API 598 Valve Inspection and Testing
Design and Construction of Large, Welded, Low-
API 620
Pressure Storage Tanks
API 650 Welded Tanks for Oil Storage
Cathodic Protection of Aboveground Petroleum
API 651
Storage Tanks
Tank Inspection, Repair, Alteration, and
API 653
Reconstruction
API 1104 Welding of Pipelines and Related Facilities
ALL API Codes In Soft Copy
ASTM V.3.2 S.3 Wear & Erosion-Metal Corrosion
ASTM V.1.3 S.1 Steel Plate, Sheet, Strip and Wire
ASTM V.3.3 S.3 Non-Destructive Testing
AWS B1.11 Guide for the Visual Examination of Welds
AWS D1.1 Structural Welding Code- Steel
Specification for Welding of Industrial and Mill Cranes
AWS D14.1
and Other Material Handling Equipment
AISC S303 Code of Standard Practice for steel Buildings & Bridges
Control of External Corrosion on Underground or
NACE
Submerged Metallic Piping System & Forms
Recommended Practice on SNT-TC-1A Personnel
ASNT
Qualification & Certification in Non-Destructive Testing
24 | P a g e
SECTION 9 SERVICE EXECUTION CHART
CATHODIC PROTECTION/
CORROSION CONTROL
VENDORS INSPECTION /
SURVEILLANCE
TTE PROPONENTS
MOBILIZATION
PROCESS
OBSERVATION
TEST
ANALYSIS
RESULT OF TEST
RESULTS (DOCUMENTATION)
ACCOUNTING
CLIENT’S COPY TTE OPERATIONS CENTRAL FILES
DEPARTMENT
DISTRIBUTION
RESOLVED/RECTIFIED ITEMS
RETURN TO SERVICE
25 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Advanced NDT
Low Frequency Electromagnetic Technique (LFET) – Boiler
Tubes and Piping
LFET data displayed in 5 different windows; 1) raw collected data 2) zoomed in data 3) C-Scan 4) B-Scan
5) 3D color coded picture. Inspection is done by a scanner moving along the test piece at a constant speed
of approximately 4” per second while watching the computer as the data is acquired. Any suspicious
signals are rescanned. If the signal repeats, the location is marked for further investigation. The Low
Frequency Electromagnetic Technique signal is analyzed and the flaw is sized using calibration standards.
When applicable, 3-Dimensional Scan Phasor XS Single Probe Ultrasonic Thickness Measurements (UTM)
are taken on the identified flaws for confirmation and in some cases, used for secondary quantification.
LFET has been used to inspect numerous pieces of equipment for several industries. A common use for
LFET inspections is boiler tubing. In the maintenance section, LFET inspects approximately 50 furnace
waterwalls annually and economizers, reheaters, and superheaters (measure the amount of magnetite
deposits in stainless steel superheater). For boiler inspections, LFET is typically used for thickness
measurements, detection of corrosion cells/hydrogen damage, and cracking. LFE T inspection is
applicable in above ground storage tanks, pipelines, heat exchangers, boiler tubes and among other
equipment.
26 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Advanced NDT
Phased Array Ultrasonic Testing – PAUT
NDTPISC utilizes PAUT for weld Inspection and crack detection, and is mainly geared
for works in power plants, petrochemical plants, pipeline construction and
maintenance, and structural metals. PAUT is most effective in revealing defects that
are hidden inside welds or structures.
• The application of PAUT is much faster to implement as compared to conventional UT,
more accurate results are obtained, all data are digitally stored, and much more safer as
this technique do not apply x-rays and gamma rays.
• NDTPISC has a CSWIP Certified PAUT Inspector dedicated to implement PAUT works.
27 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
28 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Conventional NDT
Radiographic Testing – RT
▪ The conventional RT is mainly utilized to inspect materials for hidden flaws. X-ray and
gamma ray are used to detect internal defects, in measuring wall thickness, and
corrosion detection.
▪ The inspectors of NDTPISC are well versed and experienced in this type of testing.
NDTPISC’s inspectors are ANSI/ASNT/SNT-TC-1A Level II certified technicians. A
Radiation Safety Officer (RSO) will monitor classified and non-classified workers during
the entire exposure compliant to Safety Policy and RT Procedures, and in conformance
with ASME-V Article-2.
Ultrasonic Testing – UT
▪ UT is applied for flaw detection and evaluation, dimensional/thickness measurements,
material characterizations, and more. UT is the traditional method in tracing and
analysing metal losses/cracks in vessels, tank, pipe, and other heavy walls suspected of
being internally corroded or have thinning areas or defective welds which a naked eye
cannot visualize.
29 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
30 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Vacuum Testing
Vacuum testing is one of the most adaptive method to test for any defects or leaks in
the bottom, and as efficient as Radiography does for shell weld tests. Vacuum box is
used to clear for any leaks or faults in the welding of bottom and annular plates of the
tank, and sometimes it is used on roof plates welding test. The vacuum pump attached
creates a vacuum in the vacuum box, which shows bubbles in the soap water applied in
the weld in case of any leaks or weld defects.
Engineering Services
Cathodic Protection System - CPS
▪ Engineering Design: We provide comprehensive system analysis, individual design,
manufacture, supply materials, upgrade designs and installation services using the most
advanced Cathodic Protection design tools, and construction techniques.
▪ Engineering Services: Provide site supervision of installation, commissioning,
maintenance for both sacrificial & impressed current cathodic protection system
(ICCPS). Site surveys carried out for soil resistivity, current drain ground-bed location,
CIPS, DCVG, AC corrosion monitoring, mitigation & routine monitoring.
▪ Our Engineers are available for discussion & advice on all aspects of cathodic protection
system (CPS), corrosion control activities & supported by design & engineering
capabilities.
31 | P a g e
Post Weld Heat Treatment, Stress Relieving & Hardness Testing
▪ Post Weld Heat Treatment (PWHT) is an application utilized after welding is performed.
PWHT is used to improve the properties of welded joints of piping, nozzles, vessels, and
related components using electrical resistance methods.
▪ Mainly applied on boilers, pressure vessels, process piping, and steel tank for oil
storage.
▪ Hardness testing on the other hand covers the determination of the hardness of
materials, parent metal and the weldments after PWHT is completed.
Tank Requalification
▪ A comprehensive inspection and testing services on storage tanks which covers the
following scope of works: ocular inspection and report, overall assessment of report,
calculations of minimum allowable thickness and maximum allowable working pressure,
corrosion rate calculations, remaining life expectancy calculations, out of service
inspection (OOSI) which include MFLT and Vacuum Testing, MPI on heat affected zone
areas, RT on all tee- joints, and random UTG.
32 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
33 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Sponge Jet-Blasting
The third option for effective removal of polyurea and rubberized coatings is Sponge Media
composite abrasives. Like ordinary dry abrasive blasting, Sponge Media is propelled to the surface
using pressurized air. This composite abrasive includes the one of many abrasive types/grits and
a sponge matrix, which allows for the removal of polyurea and rubber coatings quickly and with
little dust generation. Sponge (Media) Blasting does not melt or burn these flexible coatings
and also profiles the surface in the one step. Coating thickness can impact removal time, but
coatings of more than 12,5 mm (1/2 inch) have been removed successfully with Silver 30 Sponge
Media.The technology is capable of attaining all recognized standards of surface cleanliness for
abrasive blasting and can produce surface profiles of 150-plus microns (6- plus mils). It is widely
used on alloys, concrete and composite materials. It is also a documented surface preparation
solution authorized for use in many of the world's armed services
Coating Inspection
▪ NDTPISC can provide Coating Inspection for the assessment of coatings in Ferrous-Steel,
Stainless-Steel, Aluminium, Concrete, and other materials requiring coatings, for
purposes of determining the required compliance and performance.
▪ Coating Inspection paves the way for the inspection of surface preparation for
sandblasting, and for the application of required coating works.
34 | P a g e
SECTION 10 GALLERY OF JOB SERVICES
Holiday Testing
▪ A non-destructive testing method which is mainly applied to check for discontinuities
such as pinholes, porosity or flaws in insulated coatings on conductive substrates. Lack
of continuity of coating causes premature failure, which can be very expensive to repair,
and may lead to possible stoppage in production. In certain circumstances, an air pocket
can represent a substantial portion of the total thickness, and thus cause a weak point,
even though the coating is continuous.
35 | P a g e
SECTION 11 PROJECTS COMPLETED
Year 2018
CLIENT LOCATION SCOPE OF WORK
a. NDE Services (PAUT, RT, PMI, UT, PT and MT for
Meralco Gen/SBPL Mauban Quezon 500MW CFPP power plant; Vacuum Testing of Storage
Tanks & Supply of Third-Party Inspector
Daelim Phils.,Inc. Mauban Quezon a. NDE Services (PAUT, RT, PMI, UT, PT and MT for
500MW power plant b. Supply of Third-Party Inspector
a. NDE Services (PAUT, RT, PMI, UT, PT and MT for
Mauban Quezon 500MW power plant
Philspec Corp.
b. Supply of Third-Party Inspector
c. Supply of calibration blocks for PAUT and UT
a. NDE Services (PAUT, RT, PMI, UT, PT and MT for
Mauban Quezon 500MW power plant
Sebo Mec Corp.
b. Vacuum Testing of Storage Tanks
c. Supply of Third-Party Inspector
a. NDE Services (PAUT, RT, PMI, UT, PT and MT for
Mauban Quezon 500MW power plant
Yuhantech Phils.,Inc.
b. RT of Welder’s Qualification Pipes/Plates
c. Supply of Third-Party Inspector
Mauban Quezon a. NDE Services (PT and MT for 500MW power
Balance Engg Corp
plant)/Chimney structural
Team Energy Pagbilao Quezon PAUT of Boiler Tubes for the repaired UNIT 1
36 | P a g e
SECTION 11 PROJECTS COMPLETED
Year 2017
CLIENT LOCATION SCOPE OF WORK
a. NDE Services (PAUT, UT, PT and MT of Three (3)
Storage Tanks
Meralco Gen/SBPL Mauban Quezon
b. Supply of QC Inspector
c. Supply of Third-Party Inspector
Phase Array Ultrasonic Testing PAUT of Ten (10) LPG
Storage Tanks
Mechatrends Contractor Calaca, Batangas
8.0 m ID x 85.8m OL x 38mm shell thk / 21mm head
thk.)
a. Phase Array Ultrasonic Testing PAUT of Ten (10)
LPG Storage Tanks
8.0 m ID x 85.8m OL x 38mm shell thk / 21mm head
South Pacific Inc. Calaca, Batangas
thk.)
b. Tank Assessment Including NDT, Coating, Hardness
Testing
NDT of UNIT 2 Major Shutdown Including UTF, UTG,
Team Energy Pagbilao Quezon
PT, MT and PAUT of Boiler Tubes
MHPS Phils.,Inc. Pagbilao Quezon PAUT of Major Rehabilitation of Boiler
Year 2016
CLIENT LOCATION SCOPE OF WORK
Maguyam, Silang,
Fravinz Enterprise, Inc. DPT of Structural Steel
Cavite
Abba Equipment & San Fernando,
Re-qualification Report of LPG Tank 19MT (PUM 307)
Trading Services, Inc. Pampanga
Phil. Gold Processing
Masbate MPI of Ball Mill #2 Feed Trunnion Flange
and Refining Corp.
PRG Industrial Solution Pasig City Requalification Report of LPG Lorry Tank #3
PRG Industrial Solution Pasig City Radiographic Testing of 2” Ø SCH. 80 Pipe
Offshore Maritime
Subsea Advanced Subic MPI of Lifting Lugs/Pad Eyes
Technologies Inc.
Abba Equipment Trading San Fernando
Hydrotest Witness Report of LPG Plate No. (PUM-307)
and Services Pampanga
Siemens Power
Sta Rita Batangas Radiographic Testing
Operation Inc.
Non-Destructive Testing of Pressurized Vessels 26
Apo Cement Corp. Naga Cebu
Units
Riofil Corp. Batangas DPT of Carbon Steel Pipe Lateral W ye
JGC Phils Inc. Manila WQT
MFI Foundation Inc. Manila WQT and MPI
PRG Industrial Solution Pasig City Requalification Report of LPG Tank#4
PRG Industrial Solution Pasig City Radiographic Testing
Austal Philippines Balamban Cebu Radiographic Testing and DPT
37 | P a g e
SECTION 11 PROJECTS COMPLETED
Year 2015
West Canayaon,
Riofil Corp. Garcia-Fernandez, UT Flaw of Pipe Piling
Bohol
AGP Elevators &
Pasay City DPT of Steel & Gusset Plates
Installation Services
946 Remedios St.,
Kimlar Technical
Corner San
Consultants & General RT of Test Pipes
Marcelino, Malate,
Services Inc.,
Manila
Ayala Alabang,
JGC Phils., Inc. RT of Test Pipes
Muntinlupa City
Brgy. Palampas &
San Carlos Bioenergy
punao, San Carlos, UT Lamination of Bearings
Corp.
Negros Occidental
RHAJTEK
IndustrialSystem and . Marilao, Bulacan UT Lamination of Support Beam Plates
Construction Inc
CHITAI Industry Phils., Multinational Village,
DPT of Investment Casting Parts
Inc. Paranaque City
C1 Bldg. Grandville
Zamperla Asia Pacific Industrial Complex Magnetic Particle Inspection
Carmona, Cavite
Team Energy Pagbilao, Quezon RT, UT, UT Lamination, DPT
Retelco Drive,
Corner E. Rodriguez
PRG Industrial Solution / Requalification of Tank
Jr. Avenue, Bagong
Ilog, Pasig City
Brgy. Pangascasan,
Team Sual Corp. Out of Stream Inspection
Sual, Pangasinan
ABBA Equipment & San Fernando,
Requalification of Tank
Trading Services Inc. Pampanga
Pilipinas Shell Petroleum Tabangao,
Out of Stream Inspection with MFL
Corp. Batangas
38 | P a g e
SECTION 11 PROJECTS COMPLETED
Arya Residences,
AGCHEM Construction, Fort Bonifacio RT Of Stainless-Steel Fire Tank
Global City, Taguig
ALASKA Milk Corp. San Pedro, Laguna DPT & UT Gauging of Chamber Dryer 2 and 3
`Systech Industries Bautista St.
Radiographic Testing of Test Pipe 5” Dia. (WQT)
Corporation Palanan, Makati City
Salvel Construction Building 214 Niog II,
Radiographic Testing of Boiler Tubes
Maraudi Bacoor Cavite
Ortigas Ave. Pasig Radiographic Testing of 16mm x 4” x 6” Test Plate (2G)
MFI Foundation Inc.
City (WQT)
RCGC Refilling
Plant, Brgy. Del
ABBA Equipment Hydrotest Witness Report of LPG Lorry Tank
Rosario San
Trading and Services Manufacturer’s Serial No. (072384)
Fernando
Pampanga
Mechatrends
Calaca Batangas PAUT of LPG Storage Tank # 4
Contractors Corporation
OPTODEV Inc- Essilor
Biñan, Laguna On Service Inspection of Four Air Receiver Tanks
Group
Year 2014
CLIENT LOCATION SCOPE OF WORK
PHASED ARRAY ULTRASONIC TESTING (PAUT)
CBI (PHILS) TIME OF FLIGHT DIFFRACTION (TOFD)
C3 & C4 SPHERE TANKS BATANGAS CITY
PROJECT ULTRASONIC FLAW DETECTION
MAGNETIC PARTICLE TESTING (MPI)
SIEMENS POWER BATANGAS CITY RT OF UNIT 10
JGC PHILS., INC. MUNTINLUPA CITY WELDERS QUALIFICATION TEST OF VARIOUS TEST PIPES
TOTAL PHILS., CORP. MARIVELES OSI OF TANK A3 (64.5FT)
P.A. TUAZON CONST. QUEZON CITY DYE PENETRANT TESTING OF WATER PIPES
SIEMENS POWER BATANGAS CITY RT OF UNIT 40
PASAR LEYTE VACUUM TEST OF BOTTOM PLATE
SIEMENS POWER BATANGAS CITY OOSI OF TANK 90 (5.5MØ)
APO CEMENT CORP. NAGA CITY, CEBU NDE SERVICES ON VARIOUS PRESSURE VESSELS
ABBA PAMPANGA SUPPLY OF TECHNICAL PERSONNEL
SAM GAS BULACAN REQUALIFICATION OF 8MT LPG TANK
RIOFIL CORP. MISAMIS ORIENTAL UT FLAW OF PIPE PILE of MAIN BERTH TERMINAL
YWA TRADE TEST MANILA WELDERS QUALIFICATION TEST OF VARIOUS TEST PIPES
Year 2013
CLIENT LOCATION SCOPE OF WORK
DMCI POWER (135 CFB) CALACA, BATANGAS NDE of 1.8MØ UNDERGROUND PIPELINE
ABBA EQUIPMENT PAMPANGA REQUALIFICATION OF 18MT LPG TANK
REDBALL TECHNICA INC. BATANGAS ULTRASONIC FLAW DETECTION of BOX COLUMN 1 – 6
ELLIMETAL BATANGAS UT OF NEWLY ERECTED SILO TANKS
MARIVELES OOSI/MFL OF TANK B1
TOTAL PHILS., CORP.
NORTH HARBOR OOSI/MFL OF TANK 1 & 2
PHOENIX PETROLUEM CALACA, BATANGAS RADIOGRAPHIC TESTING OF 7 UNITS CHEMICAL TANK
39 | P a g e
SECTION 11 PROJECTS COMPLETED
Year 2012
CLIENT LOCATION SCOPE OF WORK
SIEMENS POWER BATANGAS OOSI/MFL OF TANK 32, 34, 41 & 30
TOTAL PHILS. CORP. BATAAN OOSI/MFL OF TANK B3, A4, B4 & B2
TAGUIG RE-QUALIFICATION OF LPG TANK 1
TOTAL LPG
MARIVELES RADIOGRAPHIC TESTING OF LPG PIPELINE
RE-QUALIFICATION OF LPG TANK 1 & 2
PETRON LPG DEPOT PAMPANGA
ULTRASONIC THICKNESS GAUGING OF AIR RECIEVER
ROBLETTE ISABELA NDT SERVICES OF STORAGE TANKS & PIPELINE
TACOPHIL ISABELA NDT SERVICES OF BOILER TUBES & PIPELINE
RE-QUALIFICATION OF LPG TANK 1 & 2
ABBA EQUIPMENT PAMPANGA
RADIOGRAPHIC TESTING OF LPG PIPELINE
JAPAN GAS CORP. ALABANG WELDER’S QUALIFICATION TEST (WQT)
PHILIPPINE ASSOCIATED
SMELTING & REFINING PASAR, LEYTE THIRD PARTY INSPECTION
CORP. (PASAR)
PURE PETROLUEM CORP. SUBIC, OLONGAPO NDT OF 9 UNITS STORAGE TANKS (NEW)
TOTAL BULK CORP. (TBC) BATANGAS OOSI/MFL OF TANK 810 & 809
PACEMCO SURIGAO ULTRASONIC FLAW DETECTION OF ROLLER PIPES
WYETH PHILS. CALAMBA OSI OF 4 UNITS STORAGE TANKS
PHIL-ASIA MANILA WELDER’S QUALIFICATION TEST (WQT)
SHILOH INTERNATIONAL ALABANG DPT & UTG OF HIGH-PRESSURE PIPELINE
TRANS-ASIA ENERGY INC. LA-UNION NDT OF CRANK PINS, CONNECTING RODS & END BOSS
HOPE MANAGEMENT &
SUBIC ULTRASONIC FLAW DETECTION ON SHIP SIDE SHELL
ENGINEERING SERVICES
40 | P a g e
SECTION 11 PROJECTS COMPLETED
Year 2011
CLIENT LOCATION SCOPE OF WORK
OOSI/MFL OF TANK 229
OOSI/MFL OF TANK302
MPI OF SPHERE TANK 1105
BATAAN
MPI OF SPHERE TANK 1103
PETRON CORP.
OOSI/MFL OF TANK 111 (115 MØ)
OOSI/MFL OF TANK 218
PANDACAN OOSI/MFL OF TANK 405
ROXAS CITY OOSI/MFL OF TANK P3
PILIPINAS SHELL
PANDACAN OOSI/MFL OF TANK 0705
PETROLEUM CORP.
OOSI/UTG OF M1, M2, M4 KETTLE
MANILA REQUALIFICATION OF LPG TANK
PHOENIX PETROLEUM BATANGAS NDT OF 3 NEWLY ERECTED TANKS
BACOLOD NDT OF 3 NEWLY ERECTED TANKS
TEAM ENERGY
PAGBILAO NDT OF 2 FUEL OIL TANKS
SUAL, PANG. DPT OF PIPELINE
MJ TENG CAVITE REQUALIFICATION OF LPG TANK
41 | P a g e
SECTION 12 PREQUALIFICATION CERTIFICATES
42 | P a g e
SECTION 12 PREQUALIFICATION CERTIFICATES
AWS ASNT
PWS PSNT
ASME
43 | P a g e