You are on page 1of 4

Sr.

R Code Line No From To Remarks Stress Calculation


No
1 CS48 50-F166-CP48-09 Battery Limit EV-2101 (N1-DN50)
Isometric Modification -
2 CP57 50-F166-CP57-01 EV-2101 (N2-DN50) P-2101 A/B (N1-HOLD)
Isometric Modification -
3 CP57 40-F166-CP57-02 P-2101 A/B (N2-HOLD) EV-2301 (N2-DN50)
Isometric Modification -
4 CP57 40-F166-CP57-03 40-F166-CP57-02 40-C661-CP48-08
Isometric Modification -
300-C661-VP-02
5 VP EV-2101 (N5-DN300) C-7302 (N1-HOLD)
D-2102 Isometric Modification Yes
600-C661-VP-01
6 VP EV-2101 (N4-DN600) C-7301 (N1-HOLD)
D-2101 Isometric Modification Yes
7 VC 50-C661-VC-04 EV-2101 (N6-DN80) T-7301 (N3-DN80)
Isometric Modification -
400-C661-VP-03
8 VP EV-2301 (N15-ø508) EV-2101 (N3-DN400)
D-2301 Can be reused as same Yes
9 HTS 25-A870-HTS-05 (Vent Line) 200-A870-HTS-04 TO SALT TANK
same as HTS-04 same as HTS-04
10 HTS 200-A870-HTS-04 EV-2301 SALT TANK
Isometric Modification Yes
11 HTS 200-A870-HTS-03 200-A870-HTS-02 EV-2301
Isometric Modification YEs
12 CP92 80-F166-CP92-02 EV-2301 (N17-NPT1/2") CP92
By BCPL BY BCPL
13 HTS 200-A870-HTS-02 SALT HEATER Salt Tank
Can be reused as same No new calculation required
14 HTS 200-A870-HTS-01 SALT PUMP Salt Furnace
Can be reused as same No new calculation required
15 VC 50-C661-VC-07 C-7302 (N2-DN80) T-7301 (N2-DN80)
Isometric Modification -
16 VC 50-C661-VC-09 C-7301 (N3.1/3.2 DN80) T-7301 (N1-DN80)
Isometric Modification -
17 VC 80-C661-VC-06 T-7301 (N4-DN80) FLOOR TRENCH (WW)
Can be reused as same -
18 VC 80-C661-VC-05 T-7301 (N5-DN80) FLOOR TRENCH (WW)
Can be reused as same -
19 VC 50-C661-VC-08 T-7301 (N6-DN50) VENT
Can be reused as same -
20 VC 50-C661-VC-11 T-7301 (N7-DN80) P-7301 A/B (N1-Hold)
Isometric Modification -
21 VC 50-C661-VC-10 50-C661-VC-14 T-7301 (N11-DN50)
Isometric Modification -
Sr. R Code Line No From To Remarks Stress Calculation
No
22 VC 50-C661-VC-14 P-7301 A/B (N2-DNHOLD) BATTERY LIMIT (VC)
Isometric Modification -
23 SCM 25-A772-SCM-01 EV-2301-N9 FLOOR TRENCH (WW)
Can be reused as same -
24 SM 40-A772-SM-12 40-A772-SM-100 HEADER
Isometric Modification -
25 SM 25-A761-SM-13 40-A772-SM-12 EV-2301 (N7-DN25)
Isometric Modification -
Tracing
26 SM 25-A761-SM-14 40-A772-SM-12
200-A870-HTS-01 Isometric Modification -
TRACING
27 SM 25-A761-SM-15 40-A772-SM-12
(200-A870-HTS-03) Isometric Modification -
28 SCM 25-A772-SCM-02 EV-2301-N9 FLOOR TRENCH (WW)
Can be reused as same -
Tracing
29 SCM 25-A772-SCM-04 FLOOR TRENCH (WW)
200-A870-HTS-01 Can be reused as same -
30 SCM 25-A772-SCM-05 Jacket of Salt Valve 6" FLOOR TRENCH (WW)
Can be reused as same -
Tracing
31 SCM 25-A772-SCM-06 FLOOR TRENCH (WW)
200-A870-HTS-03 Can be reused as same -
TRACING
32 SM 25-A772-SM-16 40-A772-SM-12
(200-A870-HTS-04) Isometric Modification -
Tracing
33 SCM 25-A772-SCM-07 FLOOR TRENCH (WW)
200-A870-HTS-02 Can be reused as same -
34 SM 25-A772-SM-04 40-A772-SM-12 PSV-8114
Isometric Modification -
35 SM 40-A772-SM-05 PSV-8114 VENT
Isometric Modification -
36 SM 25-A761-SM-03 40-A772-SM-12 VENT
Isometric Modification -
37 SM 40-A772-SM-100 BATTERY LIMIT (SM) HEADER
Isometric Modification -
38 SCM 25-A772-SCM-08 40-A772-SM-100 FLOOR TRENCH (WW)
Can be reused as same -
39 SM 25-A772-SM-09 25-A772-SM-17 PSV-8115
Isometric Modification -
40 SM 25-A772-SM-11 25-A772-SM-09 VENT
Isometric Modification -
41 SM HOLD-A772-SM-10 PSV-8115 VENT
Isometric Modification -
42 SM 25-A772-SM-17 40-A772-SM-100 TRACING OF HTS VENT LINE
Isometric Modification -
Sr. R Code Line No From To Remarks Stress Calculation
No
JACKET OF SALT VALVE
43 SM 25-A772-SM-18 25-A772-SM-17
10" Isometric Modification -
TRACING
44 SM 25-A772-SM-19 40-A772-SM-100
(200-A870-HTS-02) Isometric Modification -
Tracing
45 SCM 25-A772-SCM-09 FLOOR TRENCH (WW)
200-A870-HTS-04 Can be reused as same -
46 SL 80-A761-SL-100 40-A772-SM-100 Header
Isometric Modification -
47 SL 25-A761-SL-17 80-A761-SL-100 VENT
Isometric Modification -
48 SL 25-A761-SL-15 80-A761-SL-100 PSV-8111
Isometric Modification -
49 SL 50-A761-SL-16 PSV-8111 VENT
Isometric Modification -
SCL 25-A761-SCL-09 80-A761-SL-100 FLOOR TRENCH (WW) Isometric Modification -
50

51 SL 25-A761-SL-01 80-A761-SL-100
TRACING LINE Isometric Modification -
52 SL 25-A761-SL-02 80-A761-SL-100
TRACING LINE Isometric Modification -
Tracing
53 SL 25-A761-SL-03 80-A761-SL-100 (40-F166-CP57-03)
Isometric Modification -
54 SL 25-A761-SL-04 80-A761-SL-100
TRACING LINE Isometric Modification -
55 SL 25-A761-SL-05 80-A761-SL-100
TRACING LINE Isometric Modification -
SCL 25-A761-SCL-01 TRACING FLOOR TRENCH (WW) Isometric Modification -
56 (40-C661-CP48-09)

SCL 25-A761-SCL-02 EV-2101 (N14) FLOOR TRENCH (WW) Isometric Modification -


57
Heating coil
SCL 25-A761-SCL-03 Tracing FLOOR TRENCH (WW) Isometric Modification -
58
(40-F166-CP57-03)
SCL 25-A761-SCL-04 Tracing FLOOR TRENCH (WW) Isometric Modification -
59
(50-F166-CP57-02)
SCL 25-A761-SCL-05 Tracing FLOOR TRENCH (WW) Isometric Modification -
60
(50-F166-CP57-02)
EV-2301 (N1) Preheating
61 SL 25-A761-SL-06 80-A761-SL-100
For start up only Isometric Modification -
EV-2301 (N18) Purging
62 SL 25-A761-SL-07 80-A761-SL-100
For shut down only Isometric Modification -
63 SL 50-A761-SL-14 PSV-8118 VENT
Isometric Modification -
Sr. R Code Line No From To Remarks Stress Calculation
No
64 WP 25-A761-WP-01 BATTERY LIMIT SERVICE STATION
Can be reused as same -
65 SS 25-C661-SS-04 P-8301 A/B (N2-DNHOLD) 40-C661-CP48-08
Isometric Modification -
66 SL 25-A761-SL-08 80-A761-SL-100 SERVICE STATION
Can be reused as same -