L (Lub) *Keep the cable far away from power cords or other things that may cause noise.
Drain
Separ Noise can cause malfunctions.
Mech
Press SW Connector pin No.
Res press [Connector (male)] Cable
exh valve (1) +V (brown) Connect to [+] of DC power supply
SlowStart Pin No.
12 to 24 VDC ±10% *
Anti-bac/Bac- 3
remove Filt 2 (2) OUT1 (white)
Main circuit
Ending * IODD file can be downloaded from the CKD website. (https://www.ckd.co.jp/english)
1560
WFK2 Series
Display screen details
(2) W
indow mode Hysteresis hy1 Hysteresis hy1 Silncr
CheckV/
OUT 1 and 2 can both be set. ON ON other
Can be set with instantaneous flow rate
Fit/Tube
and temperature. OFF OFF
Can memorize 2 types each of Nozzle
Lo1 Hi1 Instantaneous flow rate Lo1 Hi1 Instantaneous flow rate
instantaneous flow rate and temperature. [Normally open] [Normally closed] Air Unit
Function mode Function mode Function mode Mode selection PrecsCompn
Output1 Output setting Switch_□
Electro
Output2 Analog_Flow Mode Select NO/NC selection
Output setting Analog_Temp NO/NC
Press SW
Hold Response time Switch_Flow1 Lower limit Threshold (Lo1) setting ContactSW
down for NPN/PNP Select Switch_Flow2 Select Upper limit
2 seconds Unit Output Setting Switch_Temp1 Switch_□ Hysteresis Threshold (Hi1) setting
and press and press AirSens
Hysteresis (hy) setting
PresSW
Cool
Air Flo
Sens/Ctrl
max max
Integrating flow
Integrating flow
Ending
1561
WFK2 Series
F.R.L. (4) N
PN/PNP conversion *Perform NPN and PNP conversion when the switch output is OFF.
Conversion settings are applied when the power is turned back ON.
F.R. NPN and PNP can be converted.
F (Filtr) Function mode Function mode
Output1 NPN/PNP NPN/PNP selection
R (Reg) Output2 NPN
Output setting Select PNP
L (Lub) Hold Response time NPN/PNP Exit
down for NPN/PNP and press
Drain 2 seconds Unit
Separ
Mech
Press SW
Res press
exh valve 2. Integrated pulse output
SlowStart
Anti-bac/Bac- Pulse output matches the integrating flow count. 40 msec
remove Filt Selectable pulse rates ON
Film
Resist FR Model 5L 20 L 50 L 100 L 250 L
Oil-ProhR 0.1 L ○ ○
Med 0.5 L ○ ○ ○
Press FR 1L ○ ○ ○ ○
No Cu/ 10 L ○ ○ ○ ○
OFF
PTFE FRL
50 L ○ ○ ○
Outdrs FRL 100 L ○ ○
Adapter
Joiner
Function mode Function mode Function mode
Press Output1 Output setting Pulse_Integrated
Gauge Output2 Switch_Temp2 Pulse rate Pulse rate setting
CompFRL Hold
Output setting
Response time
Pulse_Integrated
Switch_Integrated 0.1 L
down for NPN/PNP Select External Input Select Exit
LgFRL 2 seconds Unit Output Setting Exit Pulse_Integrated
and press and press
PrecsR
VacF/R
Clean FR
3. Analog output
ElecPneuR
AirBoost (1) Output conversion
0 to 5 V/1 to 5 V: Select between 0 to 5 V output and 1 to 5 V output
Speed Ctrl
4 to 20 mA: No output conversion
Silncr 0 to 10 V/1 to 10 V: Selectelect between 0 to 10 V output and 1 to 10 V output
CheckV/ Applied to instantaneous flow rate, temperature output
other
Fit/Tube Function mode Function mode Function mode
Output1 Output setting Analog_Flow Range conversion
Nozzle Output2 Analog_Flow Output range
Output setting Analog_Temp Original range
Air Unit Hold Response time Select
Output Setting
Switch_Flow1 Select
Analog_Flow or
Exit
down for NPN/PNP Switch_Flow2
and press Analog_Temp and press
PrecsCompn 2 seconds Unit Switch_Temp1
Electro
Press SW
ContactSW
AirSens (2) Original analog output
PresSW An analog output function that freely sets the upper and lower limits of normal analog output.
Cool *The set range cannot be greater than the max. flow rate of each flow rate range
Air Flo
Sens/Ctrl 5.5 V, 11 V 5.4 V, 10.9 V or 21.6 mA
Analog output
Analog output
WaterRtSens 5 V, 10 V 5 V, 10 V or 20 mA
TotAirSys
(Total Air)
TotAirSys 1 V or 4 mA
(Gamma)
Gas 0V
generator Upper limit set value F.S. F.S. x 1.1 Upper limit set value F.S. F.S. x 1.1
Instantaneous flow rate, temperature Instantaneous flow rate, temperature
RefrDry
DesicDry Function mode Function mode Function mode Function mode
Output1 Output setting Analog_Flow Analog_Flow
HiPolymDry Output2 Analog_Flow Output range Original range
Output setting Analog_Temp Original range Lower limit
MainFiltr Hold
down for
Response time
NPN/PNP
Select
Output Setting
Switch_Flow1
Switch_Flow2
Select
Analog_Flow or
Exit Select
Original Range
Upper limit
Exit
Dischrg 2 seconds Unit and press Switch_Temp1 Analog_Temp and press and press
etc
Upper/Lower limit value setting
Ending
1562
WFK2 Series
4. Span adjustment F.R.L.
F.R.
Span adjustment can be set from 0.1 to 2.5 times with the initial flow rate value.
[Ex.] When set to 2.0 times F (Filtr)
Flow rate Flow rate R (Reg)
5 L/min 10 L/min
L (Lub)
Drain
Separ
Mech
Press SW
500 Hz Frequency 500 Hz Frequency Res press
exh valve
Function mode Function mode Function mode
Output1 Span adjustment Span adjustment
SlowStart
Output2 Display Span magnification settings Anti-bac/Bac-
Output setting Color 1.0 remove Filt
Hold Response time Peak Hold_Q Select Times
down for to change Span Adjustment Film
NPN/PNP Peak Hold_T Exit
2 seconds Unit the page Operating time
and press Resist FR
Oil-ProhR
Med
Press FR
No Cu/
5. Setting response time PTFE FRL
Outdrs FRL
(1) Timer selection Adapter
Instantaneous flow rate response time (average movement time) can be changed. Joiner
Select from 0.25 sec, 0.5 sec, 1 sec, 5 sec, and 10 sec (1 sec at factory settings) Press
Gauge
(2) Duration can be set from 0 to 9 sec CompFRL
During switch output, the time it takes for the output to occur after exceeding the threshold can be set.
Duration Duration LgFRL
Flow rate Flow rate
Output
PrecsR
PrecsCompn
Electro
Press SW
ContactSW Main color adjustment Changed color adjustment
Ending Refer to the instruction manual regarding operation of other functions (setting copy, external input, unit change, simulation output, power ON time display, all reset, etc.).
1564
WFK2 Series
Easy setting function F.R.L.
F.R.
Frequently used settings can be set from the normal screen using shortcut operations.
F (Filtr)
Changing main screen R (Reg)
display Run mode
L (Lub)
Flow rate
Integrating flow Drain
Temperature
Separ
Output1 setting Select
Output2 setting
Mech
Off Press SW
Res press
to return to
exh valve
Display selection main screen
SlowStart
Anti-bac/Bac-
Switch setting remove Filt
Run mode Film
Hysteresis mode Out1 Switch_Flow1 Resist FR
Hy Oil-ProhR
L/
Select the numerical
00.0 min Med
value to be changed
and press 00 °C Press FR
No Cu/
PTFE FRL
Change threshold
Outdrs FRL
Adapter
Window mode Joiner
Press
Run mode
Gauge
Out1 Switch_Flow1
W Hi 00.0 L/ CompFRL
W Lo 00.0 min
Select the numerical LgFRL
value to be changed
and press 00 °C
PrecsR
Change threshold
VacF/R
Clean FR
Integrated Switch setting
Run mode ElecPneuR
Out1 Switch_Int
AirBoost
00000 L
Select the numerical Speed Ctrl
value to be changed
and press 00 °C Silncr
Change threshold CheckV/
other
Fit/Tube
Integrated Pulse setting Nozzle
Run mode
Out1 Pulse_Int Air Unit
L/
000 pulse PrecsCompn
Select the numerical
Electro
value to be changed
and press 00 °C Press SW
Change pulse intervals ContactSW
AirSens
PresSW
Integration reset Cool
Run mode Air Flo
Reset Sens/Ctrl
Integrating Flow?
No
WaterRtSens
Yes TotAirSys
Hold down (Total Air)
simultaneously TotAirSys
for 2 seconds Reset integration (Gamma)
Gas
generator
RefrDry
Key lock
Run mode
Key lock
DesicDry
UnLock HiPolymDry
Lock
MainFiltr
Hold down
simultaneously
Dischrg
for 2 seconds Execute key lock etc
Ending
1565