You are on page 1of 2

RE 58 012/04.

93

Electronic Amplifier FT E 0012 (Series 1X) RE


for the control of proportional valves 58 012/04.93
(plug amplifier)

The electronic amplifier FT E 0012 is used for the control of


proportional directional valves, proportional pressure relief
valves and proportional pressure reducing valves.

It is piloted by a pulse width modulated 5 V-rectangular


signal, for example from a micro controller.

The control circuitry essentially consists of a pulse duty/


current transformer with a low-loss out-put stage.

The supply voltage range from 8.5 to 32 V and is suitable for


both car and lorry batteries.

K 4982-1
FT E 0012 F1X/...
(For applications outside these
Input signal Technical data parameters please consult us)
Supply voltage UB: 12 V (8,5 to 16 V) DC,
Input nominal Control example: 24 V (18 to 32 V) DC
value signal Increase of current from 0 mA
Nominal coil resistance
U
to nominal current. Operation with 12 V (at 20°C) R : 2,4 Ω (1 to 5,4 Ω)
Operation with 24 V (at 20°C) R : 4,8 Ω (2 to 19,5 Ω)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pulse duty current allocation :
+5V
(other output currents 100 % =^ 4,8 A
on request) 100 % =^ 2,4 A
100 % =^ 1,2 A
Level of the variable : 5V (4,8 to 5,2 V)
0V pulse duty signal
T T T T T T T T T T
time t Frequency of the : 100 Hz to 50 kHz
variable pulse duty signal
Output characteristics Chopper frequency f : to be determined
internally acc.
to valve data sheet
I Permissible ambient temperature t : – 40 to + 80 °C
Temperature drift of the electronics : typical
2,4
± 0,25 %
Range from –40 to + 80 °C max ± 0,5 %
(referred to /max )
1,8
Output current in A

Flat pin connections : 6,3 x 0,8 mm


12,5 mm long
1,2 Dimensions without : 30 x 60 x 70 mm
flat pin connections
Insulation to DIN 40 050 :
0,6 Electronics IP 54
Flat pins IP 00
Polearity safeguard and
0 short circuit protection : Yes (with customer-
0 20 40 60 80 100 installed fuse)
Pulse duty in % Max. output current limitation : on request
Weight m : 100 g
Ordering Code

FT E 0012 F 1X – *
Flatpin connections
6,3 x 0,8 =F Further details in clear text 1 )
Series 10 to 19 (10 to 19: Installation and = 1X D = Type pressure valve
connection dimensions remain unchanged) W = Type directional valve
Max output current 4,8 A = 4,8 Resistance proportional solenoid RDC
Max output current 2,4 A = 2,4 (resistance value at 20° C)
Max output current 1,2 A = 1,2 F 300 = Chopper frequency 300 Hz
1 F 200 = Chopper frequency 200 Hz
) Option: programmable function generator, nominal value
F 150 = Chopper frequency 150 Hz
manipulation e.g. ramp,pilot current, step change, linearizing action

1/2
RE 58 012/04.93
Terminal connections

+U B
12 V (8,5 to 16 V) DC
24 V (18 to 32 V) DC
15 +UM +U B
+U B DC Proportionl
Fuse M0 solenoid
31 DC T
-UM
0V

1
U 12 V: ca. 2,4 Ω
0V Rs 24 V: ca. 4,8 Ω
U

Input nominal value pulse Current Switching


width modulated Option regulator stage
0 / +5V D
St2 + – G
S
(referred to 0 V) pulse U
duty 0...100% e.g. 1 kHz
Programmable
function generator
0V

Unit dimensions (Dimensions in mm)

70 30

K
FTE0012F1X/XXFXXX-XX REXROTH
MAN.DATE: week/year CONT.NR.: XXX 31
K K: N.C.
50 St2 50: N.C. 50 LS St2
31 St2: PWM – INPUT
LS 31 0V GROUND
:
60

LS: N.C.

St1 St1: N.C. St1


LH: N.C.
LH 15 T 15: +12 V / 24 V DC 15
1: SOLENOID LO
1 LH 1 T
T: SOLENOID HI

12,5

Connector block plug-in type FT E 0013 F1X to RE 58 013 (Dimensions in mm)

Suitable kit: FT plug-in connector block


(to be ordered seperately)
consisting of:
84

74

61

– Block acc. to diagram


– 10 flat pin sockets 6.3 x 0.8 mm
crimp connection 0.5 mm to 1.5 mm2
– 6 flat pin sockets 6.3 mm x 0.8 mm
crimp connection 1.5 to 2.5 mm2

10 40
4,3

40

Mannesmann Rexroth GmbH Mannesmann Rexroth Limited


D-97813 Lohr am Main Cromwell Road, St. Neots,
Jahnstraße 3-5 • D-97816 Lohr am Main Huntingdon, Cambs. PE19 2ES
Telefon 0 93 52 / 18-0 • Telefax 0 93 52 / 18-10 40 Tel: (01480) 476041
Telex 6 89 418 - 0 Fax: (01480) 219052
The specified data are for product description purposes only and must not be interpreted
2/2 as warranted characteristics in a legal sense. All rights reserved – Subject to revision

You might also like