Professional Documents
Culture Documents
93
K 4982-1
FT E 0012 F1X/...
(For applications outside these
Input signal Technical data parameters please consult us)
Supply voltage UB: 12 V (8,5 to 16 V) DC,
Input nominal Control example: 24 V (18 to 32 V) DC
value signal Increase of current from 0 mA
Nominal coil resistance
U
to nominal current. Operation with 12 V (at 20°C) R : 2,4 Ω (1 to 5,4 Ω)
Operation with 24 V (at 20°C) R : 4,8 Ω (2 to 19,5 Ω)
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pulse duty current allocation :
+5V
(other output currents 100 % =^ 4,8 A
on request) 100 % =^ 2,4 A
100 % =^ 1,2 A
Level of the variable : 5V (4,8 to 5,2 V)
0V pulse duty signal
T T T T T T T T T T
time t Frequency of the : 100 Hz to 50 kHz
variable pulse duty signal
Output characteristics Chopper frequency f : to be determined
internally acc.
to valve data sheet
I Permissible ambient temperature t : – 40 to + 80 °C
Temperature drift of the electronics : typical
2,4
± 0,25 %
Range from –40 to + 80 °C max ± 0,5 %
(referred to /max )
1,8
Output current in A
FT E 0012 F 1X – *
Flatpin connections
6,3 x 0,8 =F Further details in clear text 1 )
Series 10 to 19 (10 to 19: Installation and = 1X D = Type pressure valve
connection dimensions remain unchanged) W = Type directional valve
Max output current 4,8 A = 4,8 Resistance proportional solenoid RDC
Max output current 2,4 A = 2,4 (resistance value at 20° C)
Max output current 1,2 A = 1,2 F 300 = Chopper frequency 300 Hz
1 F 200 = Chopper frequency 200 Hz
) Option: programmable function generator, nominal value
F 150 = Chopper frequency 150 Hz
manipulation e.g. ramp,pilot current, step change, linearizing action
1/2
RE 58 012/04.93
Terminal connections
+U B
12 V (8,5 to 16 V) DC
24 V (18 to 32 V) DC
15 +UM +U B
+U B DC Proportionl
Fuse M0 solenoid
31 DC T
-UM
0V
1
U 12 V: ca. 2,4 Ω
0V Rs 24 V: ca. 4,8 Ω
U
70 30
K
FTE0012F1X/XXFXXX-XX REXROTH
MAN.DATE: week/year CONT.NR.: XXX 31
K K: N.C.
50 St2 50: N.C. 50 LS St2
31 St2: PWM – INPUT
LS 31 0V GROUND
:
60
LS: N.C.
12,5
74
61
10 40
4,3
40