87

Relay modules RE
VT 11027 and VT 11028 (Series 1X) 29 742/12.87

Relay modules VT 11027-1X and VT 11028-1X are used to switch


electrical actuators (e.g. electronic amplifiers, solenoids and resistive
loads) on and off.

They basically consist of:


– Relay with LED indicator

– Capacitor with reverse polarity and overload protection

F 87 169
VT 11 027-1X
Technical Data - Relay:
– Contacts
No. of contacts one pair
Type of contact simple contact
Switching voltage Umax AC: 24 V + 20 %
Umax DC: 36 V (see diagram)
Continuous current/switch off current Imax: see diagram
Contact material AgCdO
(This material is not suitable for switching low currents)
– Coil
Nominal current – VT 11027 UN : 24 V
Rcoil: approx. 720 Ω
– VT 11028 UN : 12 V
Rcoil: approx.. 210 Ω
Nominal power PDC : approx. 500 mW
Voltage range see diagram
Drop out voltage at 25 °C UA : ≥ 0,15 • UN
– General
Mechanical life ≥ 20 • 106 operations
Maximum switching frequency – mechanical 72000/h
– electrical 3000/h
Response time t: approx. 4 ms
Drop out time t: approx. 6 ms
Settling time t: approx. 2 ms

Technical Data - Capacitor:


General 2200 µF / 50 V (continuous switching)
Over voltage protection VDR 39 V / 1 mA

Technical Data - Housing:


Installation position optional
Ambient temperature t: – 25 °C to + 70 °C
Weight (total) m: approx. 0,1 kg

For operation outside these parameters, please consult us!

1/2
RE 29 742/12.87
DC switching power (load limit curves)

9
8
7
1
6 Curve 1: one NO contact, resistive load
DC in A →

(relay coil with quenching diode)


5
2 Curve 2: one NO contact, inductive load L/R = 30 ms
4
3
3 Curve 3: one NO contact, inductive load L/R = 40 ms
2
1
0
0 5 10 15 20 25 30 35 40 45
DC voltage in V →

Block circuit diagram Permissible control voltage range


Maximum control voltage for nominal contact load
+ UB Operating 1 4 Service 2,2
voltage *)
contacts **)
+ 2,0
U
2 5 1,8
0V
1,6
US /UN →

1,4

+ US Control 3 6 1,2
GND
voltage *)
1,0

0,8
Note: *) Short circuit occurs if polarity is reversed
**) Switching of capacitive loads only if 0,6
– 40 – 20 0 + 20 + 60 + 100
sufficient resistive load is inserted before
capacitance! Ambient temperature in °C →

Terminal connections Unit Dimensions (in mm)

+ UB 1 4
Operating voltage Service
contacts Carrier rail NS 35/7,5
0V 2 5 to DIN 50 022

Control voltage US 3 6 GND


4 5 6

Ordering Code

VT 11 0 _ _ –1X *
79

Relay module 24 V = 27 Us on
Relay module 12 V = 28
Series 10 to 19 = 1X
(10 to 19, installation details unchanged) 1 2 3
Further details in clear text
85,5 25

Mannesmann Rexroth GmbH G.L.Rexroth Ltd.,


D-97813 Lohr am Main Cromwell Road, St. Neots,
Jahnstraße 3-5 • D-97816 Lohr am Main Cambridgeshire, PE19 2ES.
Telefon 0 93 52 / 18-0 • Telefax 0 93 52 / 18-10 40 Tel: 0480 476041
Telex 6 89 418 Fax: 0480 219052
All rights reserved – Subject to revision