iPASOLINK Introduction 90
Concept of Advanced AMR
To keep high transmission efficiency, Modulation scheme and Traffic capacity are automatically selected in accordance with the path
condition with QoS. (LAN Throughput –in small packet size: 64 bytes)
iPASOLINK Introduction
iPASOLINK – Adaptive Modulation Radio
CS
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz
Modulation
Radio Max Packet Radio Max Packet Radio Max Packet Radio Max Packet Radio Max Packet
capacity Throughput capacity Throughput capacity Throughput capacity Throughput capacity Throughput
Mbps Mbps* Mbps Mbps* Mbps Mbps* Mbps Mbps* Mbps Mbps*
QPSK 10 13 22 27 45 40 57 56 78 91 81 113
128 QAM 39 47 79 96 159 142 198 198 274 320 286 398
256 QAM 45 53 90 111 182 162 227 226 314 366 327 456
512 QAM 60 124 204 184 254 254 351 410 370 510
Note: * Maximum throughput at 64 byte VLAN tagged frame passed rate base (L1 compression wire speed)
AMR is a technology to improve robustness mainly in the packet transmission environment by utilizing thermal threshold
difference between modulation hierarchy such as QPSK and 2048 QAM
On the fine day, the operator can get the 229Mbps throughput over the link which is designed for 57Mbps throughput as
illustrated in the figure. (QPSK to 256 QAM) (Figure previous page)
iPASOLINK support hitless modulation switchover from 2048QAM to QPSK as shown in table.
HSG- High System Gain HC- High Capacity
iPASOLINK Introduction 92
AMR Switching Procedure
Payload
Block Diagram Payload OH Payload OH Payload OH Payload OH OH Payload OH
Tx side Rx side
(3) Header Information (4) Header Information
IN OUT
Tx DPU MOD AGC DEM Rx DPU
iPASOLINK Introduction
iPASOLINK – Adaptive Modulation Radio
256QAM
C/N 27 dB (128Q)
64QAM
16QAM
C/N 21 dB (32Q)
AMR Mode: CNR + RSL
Down CNR, Up RSL
C/N18 dB (16Q) QPSK
Modulation Up
QPSK C/N 33 dB + No Error
iPASOLINK Introduction
iPASOLINK – Adaptive Modulation Radio
“Reference modulation” is the word of definition in AMR operation, that is base condition in link budget calculation
and this is related to ATPC operation. The selection of reference modulation and TX power control (MTPC/ATPC)
relates to link budget of system gain and capacity. Please refer as follows.
dBm
24
23
22
21 Ref.256QAM
Ref.QPSK
20
19
18
QPSK 32QAM 128QAM Modulation
iPASOLINK Introduction
Adaptive Modulation Radio (AMR)
Microwave links are designed to carry traffic at 99.999% availability under all path conditions with a approx. 30 dB
fade margin. With higher modulation for the same link 99.98% availability can be achieved with reduced fade margin
for higher throughput.
QPSK 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM MODULATION SCHEME
114 Mbps 229 Mbps 287 Mbps 345 Mbps 402 Mbps 460 Mbps 56 MHz CH BW
iPASOLINK Introduction 96
EQUIPMENT CLOCK/ SYNCHRONIZATION
97
2G Network Synchronization
GPS T1 / E1
TDM Network
Dedicated Clocks
BITS / SSU STM-1
3G Network Synchronization
GPS T1 / E1
Sync ETH
TDM Network
Dedicated Clocks Packet
BITS / SSU STM-1 Network
IEEE 1588 v2
GPS
Sync ETH
Dedicated Clocks Packet
BITS / SSU Network
IEEE 1588 v2
98
There are four quality levels for clocks in SDH:
Primary Reference Clock G.81
SSU Slave clock (transit node) G.812
SSU Slave clock (local node) G
SDH network element clock (SEC) G.813
PRC
EEC MAX
20
EEC
EEC
2 SSU
EEC MAX
20
EEC
EEC
3 SSU
EEC
EEC
Max 10 SSU
99
G.8261 Synchronous Ethernet
MAC Ethernet PHY Ethernet PHY MAC SDH Sync Ether – G.8261
PRC PRC
Bit Stream Bit Stream
TX CLK TX CLK
Conventional Conventional SSM (ITU-T G.707) SSM (ITU-T G.707)
Ethernet line card Ethernet line card
SDH Overhead OAMPDU
LO +/- 100PPM LO +/- 100PPM
8000/Sec 10 / Sec
Sync Ether clock performance is similar to what is available in SDH and PDH timing
Sync Ether clock distribution can be an extension of existing synchronization distribution system
Sync Ether does not impact existing IEEE 802.3 specification
Sync Ether module extract system clock and converts to Sync E clock
Similar to SSM in SDH based networks Sync E provide SSM message (G.8264)
100
REDUNDANCY SYSTEM
CONFIGURATIONS
iPASOLINK Introduction
Possible Configurations – Hot Standby
Single Antenna HS System
MOD M
ODU-1 ODU-1 MOD
M M M
(TX) F1 F1' (TX)
P P P P
HL HL
HYB HYB
SW SW
ODU-2 ODU-2
DEM M M
(RX) F1'
F 1' (RX) M M DEM
F1
P P P P
ODU-2 ODU-2
MOD X X X X MOD
(TX) F1 F1 ' (TX)
ODU-1 ODU-1
MOD M M
(TX) F1 F1 F1' (TX)
M M MOD
P P P P
HL HL
SW SW
ODU-2 ODU-2
DEM M M M M DEM
(RX) F1' F1 (RX)
P P F 1' F1 P P
ODU-2 ODU-2
MOD X X X X MOD
(TX) F1 F 1' (TX)
Space Diversity
MOD M
ODU-1 ODU-1 MOD
M M M
(TX) F1 F1' (TX)
P P P P
P P
(TX) F1 F1 F 1'
P P
Frequency Diversity
F1
MOD M
ODU-1 ODU-1 M MOD
M M
(TX) F1 F1' (TX)
P P HYB F 1' P P
DEM X X
ODU-1 F2 ODU-1 X X DEM
(RX) F1' F1 (RX)
HL HL
SW SW
ODU-2 ODU-2
DEM M M M M DEM
(RX) F2' F2 (RX)
P P P P
ODU-2 ODU-2
MOD X X X X MOD
(TX) F2 F2' F2' (TX)
iPASOLINK Introduction
ATPC Operation
TX OUT
When RSL reaches -60dBm at STN –B STN-
ATPC TX MIN
A starts to increase the TX power in 1 dB
steps, this process continues until the ATPC deep shallow
TX MAX level is reached. Any RSL drop
below this point is not compensated. In the
UP Mode ATPC operation starts at -55dBm
RX Level
because of the fixed 5dB hysteresis. Up Mode
-55dBm
(5dB Fixed)
Hysteresis
The ATPC Control transmits the information
on the receiving level to the opposite station
and controls the transmission level of its RX Threshold
(-60dBm)
own station in accordance with the receiving Down Mode
level of the opposite station.
The ATPC Control can be used in several configurations:
Station - B
ATPC - ATPC
MTPC - ATPC Fading depth
deep shallow
ATPC - MTPC
iPASOLINK Introduction
100E/100/200
IF LOOP-BACK
400/1000
iPASOLINK Introduction
STM-1 NEAR-END LOOP-BACK
E1 NEAR-END LOOP-BACK
E1 FAR-END LOOP-BACK
iPASOLINK Introduction
XPIC SETTING
109
Master Slave
110
Block diagram of XPIC Configuration
RX signal
Intf. signal
MOD TX
A/D CRC
- DEC
Canceling
~ ~ LO ~
Carrier
signal
IF OSC Recovery
ODU(V)
~
Error signal
A/D EPS XPIC
X-IF
Horizontal ODU(H)
IF OSC
Canceling
Carrier
LO ~ signal
MOD TX
Recovery
A/D CRC
- DEC
~ ~ Intf. signal
RX signal
111
F1 (V)
Vertical
OMT Horizontal
F1 (H)
(1+0) XPIC
F1 (V) F1 (V)
Vertical Vertical
Horizontal
OMT Horizontal OMT
F1 (H) F1 (H)
112
Vertical
Vertical
F1 (V)
F1 (H) Horizontal
Horizontal
Vertical
F1 (V) F12(V)
Vertical
F1 (H) F2 (H)
Horizontal
Horizontal
(1+1) Twin Path
113
Master-1 (V )
Master-2 (V )
F1 ( V )
Vertical
F2 ( V )
Horizontal
Slave-1 (H )
Slave-2 (H )
114
F1 (V) (1+0) XPIC
Vertical
OMT Horizontal
F1 (H)
Vertical
Vertical
F1 (V)
F1 (H) Horizontal
Horizontal
115
iPASOLINK System Configuration File Backup Procedure Configuration Upload Procedure (USB to IDU) IDU Power OFF
Configuration File Upload Procedure (IDU to USB) •IDU Power OFF
•Insert USB to Main Card •Insert USB to Main card
•Wait until USB is detected (observe USB LED) flash •Protect SW/ON (Up)
•Protect SW ON (Up) •IDU Power ON
•USB LED Blinks •Maint LEDs on the Main Card starts to blink
•Wait until USB LED Blinking stop •About 2m 40sec after IDU Power ON USB LED Blinks (iPaso1000)
•Protect SW OFF (Down) •Main Card Maint LED Steady
Remove USB from IDU •After few seconds put Protect SW Down
•IDU reboot start
•Main card Maint LED stop
The above process will take about 7minutes (Depends on configuration)
•Active card Maint LEDs starts to blink
116
Circuit Emulation – Pseudo Wire
iPASOLINK Introduction
ETH
E1
TDM SAToP/
E1
TDM -> CES CESoPSN
E1
TDM
Circuit Emulation
/Pseudo Wire Emulation
Data over Packet
118 118
RFC4553 - Structure-Agnostic Time Division Multiplexing (TDM)over Packet
(SAToP)
- whole E1/T1 Frame based packetization (Unstructured)
E1 Payload (IP/VLAN/MPLS)
Transport
Packet Header
Ch32 ch0 Ch32 ch0 Ch32 ch0
… … …
TDM CESoP
CES Frame/Packet
Ch32 ch0 Ch32 ch0 Ch32 ch0 Header
… … …
E1 FRAME
E1 FRAME
E1 FRAME
TS-31
TS-31
TS-31
TS-2
TS-2
TS-2
TS-1
TS-1
TS-1
.
.
CTRL WORD
CTRL WORD
PW HEADER
PW HEADER
PW HEADER
E1 FRAME
E1 FRAME
RTP
RTP
RTP
PW PAYLOAD PW PAYLOAD PW PAYLOAD
Central Customer
Office Carrier PSN Premises
Master Node Slave Node
TDM TDM
Equipment In-Band Equipment
E1 T1/E1
TDM to Time Packet
Queue
Packet Stamp to TDM
Primary Time
Reference Stamp
Source
Clock
Encode Filter
Service Service
fReference
E1 Line sync or NE clock is used at master node ACR is used at slave node
Modem-1 Modem-2
TDM Bus
Ethernet BUS
E1
Modem
XC
PWE CH1
VLAN #
MB
16E1 MSE L2SW
PWE CH64
122
Click
IFG
the OK button.MAC DA
PRE MAC SA VLAN L IP Packet FCS
4 2 V4/V6 4 Ethernet Frame
12 8 6 6 46 -1500
20bytes
Packet
46 -1500
Above including FCS in
Compressed Headers Enhanced Mode
Store Headers up to 2048
123
TITLE PARAMETER
Radio Redundancy 1+0/1+1 usage
Radio Traffic aggregation Not available/Available
Radio Bit rate (Initial key) fixed/free/AMR
Radio Bit rate (upgrade Key) Fixed>Free/Fixed>AMR/Free>AMR
Radio Capacity1 (initial Key) 10/20/50/100/150/200/300/400 Mbps
Radio Capacity2(Initial Key) parameter Radio Capacity1
Radio Capacity1 (upgrade Key) 10>20/50/100/150/200/300/400
20>50/100/150/200/300/400
50>100/150/200/300/400
100>150/200/300/400
150>200/300/400
200>300/400
300>400
Radio Capacity2 parameter Radio Capacity1
XPIC Function Not available/Available
NEO ODU Compatibility Not available/Available
Advance Header Compression Not available/Available
256 256
256 128 128 50
128 64 64 50
64 32 32 50 50
32 16 20 16 20 50
16 QPSK 10 20 QPSK 10 20 50
QPSK 10 7MHz 14MHz 28MHz 56MHz 7MHz 14MHz 28MHz 56MHz
7MHz 14MHz 28MHz 56MHz Capacity key 20 Capacity key 50
Capacity key 10
iPASOLINK Introduction
TITLE PARAMETER
ETH
RJ45 port usage (main) 2xFE available
2xFE+2xGBE available
4xGBE available
RJ45 port usage (upgrade Key) 2xFE>2xFE+2xGBE
2xFE>4xGBE
2xFE+2GBE.>4xGBE
SFP Port Usage (main) not available/ 2xGBE available
QoS Classify 4 lev Classify
8 lev Classify
LAG/LACP (line) not available/available
ETH Ring Protection not available/available
Ether-OAM(CC/LT/LB) not available/available
Ether-OAM(DM/LM) not available/available
MSTP not available/available
TDM
E1 SNCP not available/available
STM-1 MUX/DEMUX not available/available
Extension Function
SYNC ETH Clock not available/available
DHCP Server / Relay not available/available
iPASOLINK Introduction 126
TITLE PARAMETER
Radio Redundancy (initial key) 1+0/1+1 usage(1 pair) / (1+1) usage (2pair)
Upgrade key 1+0 1+1 usage(1 pair)
1+0 (1+1) usage (2 pair)
1+1 usage(1 pair) (1+1) usage (2pair)
Radio Traffic aggregation @ Not available/Available
Radio Bit rate (Initial key) fixed/free/AMR
Radio Bit rate (upgrade Key) Fixed>Free / Fixed>AMR / Free>AMR
High Modulation Not Available / 512 /1024/2048 QAM
Radio Capacity1 (initial Key) 10/20/50/100/150/200/300/400 Mbps
Radio Capacity2(Initial Key) parameter Radio Capacity1
Radio Capacity3(Initial Key) parameter Radio Capacity1
Radio Capacity4(Initial Key) parameter Radio Capacity1
Radio Capacity1 (upgrade Key) 10>20/50/100/150/200/300/400
20>50/100/150/200/300/400
50>100/150/200/300/400
100>150/200/300/400
150>200/300/400
200>300/400
300>400
Radio Capacity2 , 3, 4 parameter Radio Capacity1
iPASOLINK Introduction
TITLE PARAMETER
XPIC function not available/available (1pair)/ available (2pair)
Not available -> 1pair /Not available -> 2pair
1 pair -> 2 pair
NEO ODU Compatibility not available/available
Advance Header Compression not available/available
ETH FUNCTIONS
RJ45 port usage (main) 2xFE available / 2 GbE available
SFP Port Usage (main) Not available / 2 GbE available
SFP Port Usage (option 1) Not available / 2 GbE available
SFP Port Usage (option 2) Not available / 2 GbE available
SFP Port Usage (option 3) Not available / 2 GbE available
SFP Port Usage (option 4) Not available / 2 GbE available
Additional VLAN Table 256 Table / 4094 Table
QoS Classify 4 lev Classify / 8 lev Classify
LAG / LACP ( line) not available/available
Ethernet Ring Protection not available/available
ETH-OAM (CC/LT /LB) not available/available
ETH-OAM (LM / DM) not available/available
ETH-OAM (Link) not available/available
MSTP not available/available
iPASOLINK Introduction
TITLE PARAMETER
TDM
E1 SNCP not available/available
STM-1 APS Protection not available/available
STM-1 MUX/DEMUX not available/available
EXTENSION FUNCTIONS
SYNC ETH Clock not available/available
Additional MSE E1 16 E1 (regular Support) / 32 E1 / 64 E1
16 E1 > 32 E1 / 16 E1 > 48 E1 / 16 E1 > 64 E1
32 E1 > 48 E1 / 32 E1 > 64 E1
48 E1 > 64 E1
DHCP Server / Relay not available/available
IEEE 1588v2 PTP clock not available/available
iPASOLINK Introduction
TITLE PARAMETER
Radio Redundancy (initial key) 1+0/1+1 usage(1 pair) / (1+1) usage (n-pair)
Upgrade key 1+0 1+1 usage (n-pair) (n = 1-6)
1+1 usage(1 pair) (1+1) usage (n-pair)
Radio Traffic aggregation Not available/Available
Radio Bit rate (Initial key) fixed/free/AMR
Radio Bit rate (upgrade Key) Fixed>Free / Fixed>AMR / Free>AMR
Radio Capacity1 (initial Key) 10/20/50/100/150/200/300/400 Mbps
Radio Capacity-n (Initial Key) parameter Radio Capacity1
n = 1-12 parameter Radio Capacity-n
10>20/50/100/150/200/300/400
20>50/100/150/200/300/400
50>100/150/200/300/400
100>150/200/300/400
150>200/300/400 200>300/400 300>400
Advanced Header Compression Not available/Available
Radio Capacity2 , 3, 4…….12 parameter Radio Capacity1
XPIC function not available/available (1pair)/ available (n-pair)
Not available -> 1pair /Not available -> n-pair
n = 1-6
NEO ODU Compatibility Not available/Available
iPASOLINK Introduction
iPASOLINK Introduction
TITLE PARAMETER
ETH
RJ45 port usage (main) 2xFE available / 2 GbE available
SFP Port Usage (main) Not available / 2 GbE available
SFP Port Usage (Slot 09) Not available / 2 GbE available
SFP Port Usage (slot 10) Not available / 2 GbE available
Additional VLAN Table 256 Table / 4094 Table
QoS Classify 4 lev Classify / 8 lev Classify
LAG / LACP ( line) not available/available
Ethernet Ring Protection not available/available
ETH-OAM (CC /LT /LB ) not available/available
ETH-OAM (LM / DM ) not available/available
ETH-OAM (Link) not available/available
MSTP not available/available
iPASOLINK Introduction
TITLE PARAMETER
TDM
E1 SNCP not available/available
STM-1 APS Protection not available/available
STM-1 MUX/DEMUX not available/available
High Capacity XC not available/available
Extension Functions
SYNC ETH Clock not available/available
Additional MSE E1 16 E1 (regular Support) / 32 E1 / 64 E1
16 E1 > 32 E1 / 16 E1 > 48 E1 / 16 E1 > 64 E1
32 E1 > 48 E1 / 32 E1 > 64 E1
48 E1 > 64 E1
Main Card Redundancy Not Available / Standard /
CWDM not available/available
iPASOLINK Introduction
iPASOLINK Introduction
Indication Category Descriptions Severity
TXPWR ALM Alarm The TX PWR is lower than 3 dB. MJ
TX INPUT ALM Alarm The TX IF signal become out of range from MJ
-29 dBm ± 5 dB.
RXLEV ALM Alarm The reception level become lower than -72dBm ~ -94dBm level.(It MJ
depends on the modulation system and bit rates).
ODU CPU / Cable CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken MJ
Alarm
Open or is not connected.
Indicates the control status of the ODU TX power output. When the TX
MUTE STATUS Status -
power is set to Mute, Status is issued.
LO REF Alarm Loss of Ref LO signal of ODU. MN
TX SW Status Status Radio interface TX SW usage state in 1+1 HS Redundant configuration -
Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM,
ODU ALM Alarm MJ
ODU SELF CHECK ALM occurrence
Highest
Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU
ODU TOTAL ALM Alarm severity will
CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.
be displayed
ATPC Power ATPC control signal fault (90sec) as well as MAX Power continuation
Status -
Mode 90sec
ODU TYPE Indicate connected ODU type is not supported at iPASOLINK system, or
Alarm MJ
MISMATCH ODU type cannot use in provisioned modulation setting.
ODU PS ALM Alarm ALM in a case of Power supply interruption to ODU. MJ
ODUPS SET Status Status indication of the protection switch for ODU power supplies -
STATUS
iPASOLINK Introduction
Indication Category Descriptions Severity
Unequipped (MODEM-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(MODEM-A) Alarm The equipped type of interface is different from configured type. MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
HIBER ALM Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5) MJ
LOBER ALM Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9) MN
EARLY WARNING Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9) MN
MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, “Alarm” is issued. MJ
INPHASE. Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase -
condition. In this condition, hitless switch over is available.
L2SYNC LOSS Alarm Loss of frame synchronization of GFP frames on MODEM port. MJ
TDM/AMR Range Mismatch Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or MJ
mismatch condition of selected RX AMR modulation range and TX AMR modulation range.
TX SW Reverse Request Status TXSW request signal receiving condition from the opposite station: -
TX SW Lock in Status Status TXSW Lockin state -
MODEM PS OFF Status Indicate power off condition of power switch which is in front of MODEM-A card. -
iPASOLINK Introduction
Indication Category Descriptions Severity
Unequipped (STM1-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(STM1-A) Alarm The equipped type of interface is different from configured type. MJ
Communication
Alarm Communication failure of equipment internal control communication. MJ
FAIL(STM1-A)
Module(STM1-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
SNCP Protection Status Status SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition. -
APS Protection Status Status APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition. -
RS LOF Alarm SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port. MJ
RS TIM Alarm Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port. MJ
RS DEG Alarm B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port. MN
MS RDI Alarm Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port. MJ
iPASOLINK Introduction
Indication Category Descriptions Severity
HP UNEQ Alarm HOP (Higher Order Path) Unequipped occurrence on STM-1 port. MJ
HP TIM Alarm HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port. MJ
HP-PLM Alarm Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port. MJ
HP-RDI Alarm RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port. MJ
LP – RDI Alarm Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port. MJ
LP – PLM Alarm Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port. MJ
ALS Status Indication of automatic laser shutdown condition at STM-1 optical port. -
RS UAS Status Status UAS status indication on STM port (Repeater Section) -
iPASOLINK Introduction
Indication Category Descriptions Severity
Unequipped (16E1) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(16E1) Alarm The equipped type of interface is different from configured type. MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
E1 AIS Status ALARM/Status category can change according to " AIS Received Condition MJ / -
Setting
Usage Error Alarm Unused E1 CH input signal detection. MN
iPASOLINK Introduction
Indication Category Descriptions Severity
Item Name (Input-x) Status/ HKA Status Indication {Alarm, Normal} for every - or
Item Name (Cluster-x) Alarm HKA input. Severity selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
iPASOLINK Introduction
Indication Category Descriptions Severity
iPASOLINK Introduction
Indication Category Descriptions Severity
Unequipped (PS) Alarm Installed Power Supply Module is removed from PS slot. MJ
Unequipped (FAN) Alarm Installed FAN Module is removed from FAN slot. MJ
Unequipped (CLK2M) Alarm Installed CLK2M Module is removed from Main Card. MJ
Type Mismatch (CLK2M) Alarm The equipped type of interface is different from configured type. MJ
Quality Level Status Received quality level condition of each timing source. -
iPASOLINK Introduction
Indication Category Descriptions Severity
EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN
EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN
EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN
EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJ
Item Name (Input-x) Status/ - or Severity
Item Name (Cluster-x) Alarm HKA Status Indication {Alarm, Normal} for every HKA input. selectable
Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -
SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ
ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN
iPASOLINK Introduction
Indication Category Descriptions Severity
RSTP New Root Bridge Detect Status The notice in which new RootBridge was detected at the time of SpanningTree processing -
RSTP Topology Changed Status The notice in which a Topology change was detected at the time of SpanningTree processing -
The notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the
RSTP Protocol Migration Status time of SpanningTree processing -
RSTP Invalid BPDU Received Status Invalid BPDU message at the time of SpanningTree processing -
Loss of a conditional signaling in which the LLF control signal should be received continuously from
LLF Message Timeout Status the opposite radio equipment.
LLF Status LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN. -
The highest
Severity will
IDU TOTAL ALM Alarm IDU TOTAL ALM be reported
Total FDB Full Status The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.
FDB Full Status FDB Full indication specified per VLAN basis.
iPASOLINK Introduction
iPASOLINK Introduction 145