You are on page 1of 91

1 2 3 4 5 6 7 8

A A

OCTOFROST AB
B OctoFrost Model 4/2 RH B

Siemens-Schneider
C C

7173 SAMFRUT
DRAWING No.: E60-7173
D D

E E

F F
Printed: 2015-03-31

IQF-Actual-Flyleaf
Previous page: = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 1-002 + 1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
FLYLEAF E60-7173 1-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Table of contents Column X: An automatically generated page was edited

Page Page description Supplementary page field Date


A A
=DOCUMENTS +1 1-001 FLYLEAF 2015-02-23
=DOCUMENTS +1 1-002 Table of contents 2015-02-23
=DOCUMENTS +1 1-003 Table of contents 2015-02-23
=DOCUMENTS +1 1-004 Table of contents 2015-02-23
=DOCUMENTS +2 2-001 Technical data 2015-02-23
=DOCUMENTS +2 2-002 Layout +A1 MAIN CABINET 2015-02-23

B =DOCUMENTS +3 3-001 IO list PLC 2015-02-23 B


=DOCUMENTS +4 4-001 Parts list 2015-02-23
=DOCUMENTS +4 4-002 Parts list 2015-02-23
=DOCUMENTS +4 4-003 Parts list 2015-02-23
=DOCUMENTS +4 4-004 Parts list 2015-02-23
=DOCUMENTS +8 8-001 Cable diagram 2015-02-23
=DOCUMENTS +8 8-002 Cable diagram 2015-02-23
C C
=DOCUMENTS +8 8-003 Cable diagram 2015-02-23
=DOCUMENTS +8 8-004 Cable diagram 2015-02-23
=DOCUMENTS +8 8-015 Cable diagram 2015-02-23
=DOCUMENTS +8 8-016 Cable diagram 2015-02-23
=DOCUMENTS +8 8-017 Cable diagram 2015-02-23
=DOCUMENTS +8 8-018 Cable diagram 2015-02-23
=DOCUMENTS +8 8-019 Cable diagram 2015-02-23
D D
=DOCUMENTS +8 8-020 Cable diagram 2015-02-23
=DOCUMENTS +8 8-021 Cable diagram 2015-02-23
=DOCUMENTS +8 8-022 Cable diagram 2015-02-23
=DOCUMENTS +8 8-023 Cable diagram 2015-02-23
=DOCUMENTS +8 8-024 Cable diagram 2015-02-23
=DOCUMENTS +8 8-025 Cable diagram 2015-02-23
E =DOCUMENTS +8 8-027 Cable diagram 2015-02-23 E

=DOCUMENTS +8 8-028 Cable diagram 2015-02-23


=DOCUMENTS +8 8-029 Cable diagram 2015-02-23
=DOCUMENTS +8 8-030 Cable diagram 2015-02-23
=DOCUMENTS +8 8-031 Cable diagram 2015-02-23
=DOCUMENTS +8 8-042 Cable diagram 2015-02-23

IQF-Actual-Tableofcontents
=DOCUMENTS +8 8-043 Cable diagram 2015-02-23
F F
Printed: 2015-03-31
Previous page: 1-001 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 1-003 + 1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Table of contents E60-7173 1-002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Table of contents Column X: An automatically generated page was edited

Page Page description Supplementary page field Date


A A
=DOCUMENTS +8 8-044 Cable diagram 2015-02-23
=DOCUMENTS +8 8-045 Cable diagram 2015-02-23
=DOCUMENTS +8 8-046 Cable diagram 2015-02-23
=DOCUMENTS +8 8-047 Cable diagram 2015-02-23
=DOCUMENTS +8 8-048 Cable diagram 2015-02-23
=DOCUMENTS +8 8-049 Cable diagram 2015-02-23

B =DOCUMENTS +8 8-050 Cable diagram 2015-02-23 B


=DOCUMENTS +8 8-051 Cable diagram 2015-02-23
=DOCUMENTS +8 8-052 Cable diagram 2015-02-23
=DOCUMENTS +8 8-053 Cable diagram 2015-02-23
=DOCUMENTS +8 8-054 Cable diagram 2015-02-23
=DOCUMENTS +8 8-055 Cable diagram 2015-02-23
=DOCUMENTS +8 8-056 Cable diagram 2015-02-23
C C
=DOCUMENTS +8 8-057 Cable diagram 2015-02-23
=DOCUMENTS +8 8-059 Cable diagram 2015-02-23
=DOCUMENTS +8 8-060 Cable diagram 2015-02-23
=DOCUMENTS +8 8-063 Cable diagram 2015-02-23
=DOCUMENTS +8 8-064 Cable diagram 2015-02-23
=DOCUMENTS +8 8-065 Cable diagram 2015-02-23
=DOCUMENTS +8 8-066 Cable diagram 2015-02-23
D D
=RK +A1 001 Circuit Diagram Power supply 2015-02-23
=RK +A1 001b Circuit Diagram Power supply 2015-02-23
=RK +A1 002 Circuit Diagram Power supply 2015-02-23
=RK +A1 003 Circuit Diagram Control Voltage 24VDC 2015-02-23
=RK +A1 004 Circuit Diagram Safety relay 2015-02-23
=RK +A1 005 Circuit Diagram Secure Circuit 2015-02-23
E =RK +A1 006 Circuit Diagram PLC Configuration 2015-02-23 E

=RK +A1 008 Circuit Diagram Earth +A1 - +JB2 2015-02-23


=RK +A1 013 Circuit Diagram External signals 2015-02-23
=RK +A1 014 Circuit Diagram Ventilation +A1 2015-02-23
=RK +A1 016 Circuit Diagram Main & Decompression Valve 2015-02-23
=RK +A1 017 Circuit Diagram Dam 2015-02-23

IQF-Actual-Tableofcontents
=RK +A1 018 Circuit Diagram Vibrator 2015-02-23
F F
Printed: 2015-03-31
Previous page: 1-002 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 1-004 + 1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Table of contents E60-7173 1-003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Table of contents Column X: An automatically generated page was edited

Page Page description Supplementary page field Date


A A
=RK +A1 019 Circuit Diagram Coil Cleaning 2015-02-23
=RK +A1 020 Circuit Diagram Snow remove system 2015-02-23
=RK +A1 021 Circuit Diagram Foaming 2015-02-23
=RK +A1 026 Circuit Diagram Temperature measure 2015-02-23
=RK +A1 031 Circuit Diagram Lateral door 2015-02-23
=RK +A1 032 Circuit Diagram Media Carriage SRS 2015-02-23

B =RK +A1 033 Circuit Diagram Wavepulse (Siemens) 2015-02-23 B


=RK +A1 034b Circuit Diagram VFD 1 2015-02-23
=RK +A1 035b Circuit Diagram VFD 2 2015-02-23
=RK +A1 036b Circuit Diagram VFD 3 2015-02-23
=RK +A1 041 Circuit Diagram Bed 1 2015-02-23
=RK +A1 042 Circuit Diagram Bed 2 2015-02-23
=BUILD_DOCUMENTS +2 2-003 Layout +A2 OP-PANEL CABINET 2015-02-23
C C
=BUILD_DOCUMENTS +2 2-004 Layout +JB2 JUNCTIONBOX 2015-02-23
=BUILD_DOCUMENTS +2 2-005 Layout +JB2 FRONT LAYOUT 2015-02-23
=BUILD_DOCUMENTS +5 5-001 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-002 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-003 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-004 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-005 Terminal line-up 2015-02-23
D D
=BUILD_DOCUMENTS +5 5-006 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-007 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-009 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +5 5-010 Terminal line-up 2015-02-23
=BUILD_DOCUMENTS +9 9-001 Fuse table 2015-02-23

E E

IQF-Actual-Tableofcontents
F F
Printed: 2015-03-31
Previous page: 1-003 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +2/2-001 + 1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Table of contents E60-7173 1-004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A DATA. MOTORDATA. A

Bed 1: 1,1kW, 2,55A, 1420rpm, 0,79 Cosphi


POWER SUPPLY - 440 VAC 60Hz Bed 2: 1,1kW, 2,55A, 1420rpm, 0,79 Cosphi
MAX FUSE +A1 - 200A
CONTROL VOLTAGE +A1 - 230 VAC 60Hz
CONTROL VOLTAGE SIGNALS - 24 VDC Fan 1: 15kW, 27,5A, 2933 rpm, Cosphi 0,91
B MAIN CABINET : +A1 Fan 2: 15kW, 27,5A, 2933 rpm, Cosphi 0,91 B

CONTROL CABINET : +A2 Fan 3: 15kW, 27,5A, 2933 rpm, Cosphi 0,91
Fan 4: 15kW, 27,5A, 2933 rpm, Cosphi 0,91
JUNCTION BOX CONTROL/SIGNAL/POWER: +JB2

FREQUENCY CONVERTER BEDS : ATV71 (Schneider)


FREQUENCY CONVERTER FANS : ATV212 (Schneider)
C C
FREQUENCY CONVERTER WAVEMAKER : ATV312 (Schneider)
PLC: Siemens-S7-313C
OPERATORPANEL: Siemens-KFP1000 basic DP10"

D
WIREING D

CONTROL WIRE / 24 VDC + / DARK BLUE WAVEPULSE: 0,18kW, 0,56A, 1350rpm, 0,77 Cosphi
CONTROL WIRE / 24 VDC - (0V) / WHITE LATERAL DOOR: 0,25kW, 1,03A, 685rpm, 0,64 Cosphi
CONTROL WIRE / Analog Signals / PURPLE 0,5 sqmm SRS: 0,18kW, 0,56A, 1350rpm, 0,77 Cosphi
CONTROL WIRE / 230 VAC / L RED Awg
CONTROL WIRE / 230 VAC / N BLUE
E
POWER WIRE / 440 VAC / BLACK E

IQF-Actual-Technical_data_New_freezer - CSA-UL
HIGHEST WIRE NR INSIDE +A1 : 0xxx

F F
Printed: 2015-03-31
Previous page: +1/1-004 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 2-002 + 2
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Technical data E60-7173 2-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

1000 mm 800 mm 500 mm


+A1

+A1 +A1.2

A A

-T613

-D614
-F400

-F410

-F600

-F610

-Q611

-Q612
-Q601

-Q603
-F03
-S110
-F300

-F310

-F320

-F330

-F602

-F604
-Q02

A0-A6
B PLC B

-D302 -D312

-X2

-XU01
-F106
-F103

-F104
-F105
-F101
-F102
C C

2000 mm
-Q01 -X5

-V110
-F200
-F201
-F202
-F203
-F204
-F205
LEFT SIDE FRONT

-K208

-K369
-K349
-K359
-K110

-K206
-K207

-K209
-K210
-K309
-K319
-K329
-K339

-K403
-K405
-K406
-K407
-K413
-K415
-K416
-K417
-K111
-K03
-K04
-K05

-B12
-D322 -D401 -D411
D D

-S111
-T04
-F323

-F325

-X1 -X3 -X4


E E

200 mm
F F
Printed: 2015-03-31
Previous page: 2-001 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +3/3-001 + 2
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Layout +A1 MAIN CABINET E60-7173 2-002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

DI
2 I0.0 SAFETY RELAY OK 2 I7.0 VFD 6 - RUNNING 2 Q4.0 BED1 - CHOICE 3
A 3 I0.1 MAIN CONTACTOR ON 3 I7.1 VFD 6 - READY 3 Q4.1 BED2 - ENABLE A
4 I0.2 EMERGENCY STOP OUTLET 4 I7.2 VFD 6 - THERMAL OVERLOAD (1:ST FAN) 4 Q4.2 SPARE
5 I0.3 EMERGENCY STOP OP-PANEL 5 I7.3 VFD 6 - THERMAL OVERLOAD (2:ND FAN) 5 Q4.3 BED2 - CHOICE 1
6 I0.4 LIMITSWITCH INLET DOOR 6 I7.4 VFD 7 - RUNNING 6 Q4.4 BED2 - CHOICE 2
7 I0.5 LIMITSWITCH OUTLET DOOR 7 I7.5 VFD 7 - READY 7 Q4.5 BED2 - CHOICE 3
8 I0.6 LIMITSWITCH LATERAL DOOR 8 I7.6 VFD 7 - THERMAL OVERLOAD (1:ST FAN) 8 Q4.6 FOAMING DRYBLOWING
9 I0.7 EXTERNAL STANDBY OF FREEZER (OPTIONAL) +A3 9 I7.7 VFD 7 - THERMAL OVERLOAD (2:ND FAN) 9 Q4.7 FOAMING AIR

12 I1.0 EMERGENCY STOP INLET 12 I8.0 SPARE +A5 12 Q5.0 VFD 6 - ENABLE
13 I1.1 FOAM - LEVELSWITCH 13 I8.1 SPARE 13 Q5.1 VFD 7 - ENABLE
14 I1.2 COMPRESSOR FOR COOLING - RUNNING (OPTIONAL) 14 I8.2 SPARE 14 Q5.2 WAVEPULSE - ENABLE
15 I1.3 LATERAL DOOR - THERMAL OVERLOAD (BOTH MOTORS) 15 I8.3 SPARE 15 Q5.3 VIBRATOR - ENABLE
B +A0 16 I1.4 LATERAL DOOR - THERMAL OVERLOAD (INLET SIDE) 16 I8.4 SPARE 16 Q5.4 SPARE B
17 I1.5 LATERAL DOOR - THERMAL OVERLOAD (OUTLET SIDE) 17 I8.5 SPARE 17 Q5.5 SPARE
18 I1.6 LATERAL DOOR - OPEN 18 I8.6 SPARE 18 Q5.6 WAVE - SPEED DOWN
19 I1.7 LATERAL DOOR - CLOSE 19 I8.7 SPARE 19 Q5.7 SRS - AIR 2

22 I2.0 MCB SRS ( THERMAL OVERLOAD CARRIER)


23
24
I2.1
I2.2
ELFI SRS
SRS - FORWARD
DO AI/AO
25 I2.3 SRS - REVERSE
26 I2.4 WAVEPULSE - THERMAL OVERLOAD 22 Q0.0 RESET SECURITY RELAY PIW 752 Temperature above bed, 4-20mA
27 I2.5 SPARE 23 Q0.1 MAIN CONTACTOR ON PIW 754 Temperature below bed, 4-20mA
28 I2.6 VFD 2 - RUNNING 24 Q0.2 INTERFACE RELAY - START EXTERNAL EQUIPMENT PIW 756 Temperature in cooling media, 4-20mA
25 Q0.3 INTERFACE RELAY - COOLING MEDIA ON PIW 758 SPARE
C 29 I2.7 VFD 2 - READY
26 Q0.4 INTERFACE RELAY - HOT GAS/DEFROST ON +A0 PIW 760 SPARE C
27 Q0.5 INTERFACE RELAY ALARM
2 I3.0 VFD 1 - RUNNING 28 Q0.6 INTERFACE RELAY - COOLING LOAD PQW 752 Zone 1 speed reference, 0-10V
3 I3.1 VFD 1 - READY 29 Q0.7 SPARE PQW 754 Zone 2 speed reference, 0-10V
4
5
I3.2
I3.3
VFD
VFD
1
1
-
-
THERMAL
THERMAL
OVERLOAD (1:ST FAN)
OVERLOAD (2:ND FAN)
+A0 32 Q1.0 VALVE - MAIN AIR / DECOMRESSION
33 Q1.1 SRS - AIR 1 PQW 304 Zone 3 speed reference, 0-10V
6
7
I3.4
I3.5
VFD
VFD
3
3
-
-
RUNNING
READY 34 Q1.2 DAM 1 +A6 PQW 306 Zone 4 speed reference, 0-10V
8 I3.6 VFD 3 - THERMAL OVERLOAD (1:ST FAN) 35 Q1.3 DAM 2
9 I3.7 VFD 3 - THERMAL OVERLOAD (2:ND FAN) 36 Q1.4 FOAMING LIQUID
+A1 37 Q1.5 CCS - WATER 3
+A7
PQW 308 Zone 5 speed reference, 0-10V
PQW 310 SPARE
12 I4.0 BED 1 - RUNNING 38 Q1.6 CCS - WATER 1
D 13 I4.1 BED 1 - READY 39 Q1.7 CCS - WATER 2 D
14 I4.2 SPARE
15 I4.3 BED 2 - RUNNING
16 I4.4 BED 2 - READY 2 Q2.0 LIGHT
17 I4.5 SRS-INLET ENDPOINT SENSOR 3 Q2.1 LATERAL DOOR - OPEN
18 I4.6 SRS-OUTLET ENDPOINT SENSOR 4 Q2.2 LATERAL DOOR - CLOSE
19 I4.7 ALARM EXTERNAL EQIPMENT 5 Q2.3 LATERAL DOOR - ALLOWED TO OPEN
6 Q2.4 SRS - FORWARD
7 Q2.5 SRS - REVERSE
2 I5.0 VFD 4 - RUNNING 8 Q2.6 SPARE
3 I5.1 VFD 4 - READY 9 Q2.7 VFD 2 - ENABLE
4 I5.2 VFD 4 - THERMAL OVERLOAD (1:ST FAN)
5 I5.3 VFD 4 - THERMAL OVERLOAD (2:ND FAN) +A4 12 Q3.0 VFD 1 - ENABLE
E 6 I5.4 VFD 5 - RUNNING E
13 Q3.1 VFD 3 - ENABLE
7 I5.5 VFD 5 - READY 14 Q3.2 VFD 4 - ENABLE
8 I5.6 VFD 5 - THERMAL OVERLOAD (1:ST FAN)
+A2 9 I5.7 VFD 5 - THERMAL OVERLOAD (2:ND FAN)
15
16
Q3.3
Q3.4
VFD 5 - ENABLE
BED1 - ENABLE
17 Q3.5 SPARE
12 I6.0 SPARE 18 Q3.6 BED1 - CHOICE 1
13 I6.1 VFD 2 - THERMAL OVERLOAD (1:ST FAN) 19 Q3.7 BED1 - CHOICE 2
14 I6.2 VFD 2 - THERMAL OVERLOAD (2:ND FAN)
15 I6.3 WAVEPULSE - PROXIMITY SENSOR
16 I6.4 WAVEPULSE - RUNNING
17 I6.5 WAVEPULSE - READY
18 I6.6 SPARE
F 19 I6.7 KEY BYPASS - INLET DOOR F
Printed: 2015-03-31
Previous page: +2/2-002 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +4/4-001 + 3
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
IO list PLC E60-7173 3-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Parts list
IQF number. Quantity E-number Type number Designation: Designation 2: Manufactor: Placement:
A manufactor: A

0 +A1;+JB2

100361 4 M3AA 132 MB M3AA 132 MB Three-phase motor ABB +VFD1...+VFD3

101006 1 A2002 PTS 150A-5M-4W PT100 Givare ACANDIA +COOLING_MEDIA


20-0072-0072 +AIRVALVE;+DAM1;
100881 3 20-0072-0072EX Solenoid, ATEX CAMOZZI
EX +VIBRATOR
100362 2 CFb-A27T-R1 Solenoid CAMOZZI +CCS;+SRS

B B
100322 1 01-2471-10 CTM10 ELFI Current transformator for the ELFI M20 CG drives Automation +A1

100224 1 01-2520-45 M20 ELFI shaft monitor Unit Current watchdog function CG drives Automation +A1

101061 1 EFA500-700R5 EFA500-700R5 Cabinet Exhaust Filter ELDON +A1

100907 2 EFCS25-30 EFCS25-30 Protection cover ELDON +A1

101016 1 60.733.40 Resistor 8,45kOhm, 0,6kW SWECH +A1

100680 1 E-21.177.62 5TE6801 Outlet 230V 10A w cover Siemens +A1


C C
100516 1 E-33.480.93 LA9F703 Touchcovers for LC1F225-LC1F500 LC1F225 LC1F265 LC1F330 LC1F400 LC1F500 Schneider Electric +A1

100411 1 E-40.276.24 RPM12BD Interface relay 1CO Schneider Electric +A1

100190 5 IFM205 Proximity switch (NO contact) IFM +BED1;+BED2;


+INLETDOOR;
+OUTLETDOOR;
+WAVEPULSE

100191 7 EVM006 25m Cable for IFM205 angled (Proximity switch) IFM +BED1;+BED2;
+INLETDOOR;
+OUTLETDOOR;+SRS;
D D
+WAVEPULSE

100043 1 IB0016 IB0016 Proximity switch (NO contact) IFM +LATERALDOOR

101003 2 IFK-3007-BPK IFM206 Induktiv givare PNP IFM +SRS


G/M/60V/US-1
04-DPS
VGD24501221 +ABOVE_BED;
100061 2 VGD245012211102 PT100 Sensor with housing/transducer INOR
1102 +BELOW_BED
100202 1 7AA63M04 7AA63M04 Three-phase motor METZ +SRS

E 7AA80M08-B1 +LATERALDOORINLET; E
100203+100204 2 7AA80M08-B14 Three-phase motor METZ
4 +LATERALDOOROUTLET
100228 1 M10025 7AA63M04 Three-phase motor SEW +WAVEPULSE
SEW.DRE 90M
100958 2 SEW.DRE 90M4/TH/OL Three-phase motor SEW +BED1;+BED2
4/TH/OL
100320 1 1003204116 4116 Pt100 Transducer Multifunctional, 2 relay outputs PR electronics +A1

1 1003204116 4116 Pt100 Transducer Multifunctional PR electronics +JB2

F F

IQF-Actual-Parts_list2
Printed: 2015-03-31
Previous page: +3/3-001 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 4-002 + 4
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Parts list E60-7173 4-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Parts list
IQF number. Quantity E-number Type number Designation: Designation 2: Manufactor: Placement:
A manufactor: A

101060 1 EF300R5 EF700R5 Cabinet Ventilation Fan ELDON +A1

100472 1 E-37.220.46 800FP-POT6 Potentiometer 10kOhm Rockwell Automation +A1

101017 1 60.551.73 Resistor 1,5kOhm, 0,4kW SWECH +A1

101077 1 3188504 LV429338 Extended rotary handle Schneider Electric +A1

101080 1 3188522 LV430390 Molded case circuit breaker 160A Schneider Electric +A1

B B
101081 1 3188534 LV430470 Trip unit Schneider Electric +A1

100943 1 AFS08062 AFS08062 Cabinet +JB2 ELDON +JB2

100948 3 CBPS0660 CBPS0660 Divided bottom plate front&rear ELDON +A1

100905 1 DRA04 DRA04 Cabinet drawing pocket ELDON +A1

100413 1 RPM22BD RPM22BD Interface relay 2CO Schneider Electric +A1

100414 1 RPZ F2 RPZF2 Mounting socket for RPM 2CO Schneider Electric +A1
C C
100258 2 E-14.774.05 50.620M/EMVD Cable gland emc M20 For cables 9-13 mm JACOB +JB2;+WAVEPULSE

100261 2 E-14.776.66 50.220MPOT Nut for cable gland emc M20 JACOB +JB2;+WAVEPULSE

100952 7 E-21.120.37 A9F04102 Fuse, 1-pole C2A Schneider Electric +A1

100953 3 E-21.120.39 A9F04104 Fuse, 1-pole C4A Schneider Electric +A1

100954 1 E-21.120.40 A9F04106 Fuse, 1-pole C6A Schneider Electric +A1

100681 1 E-21.649.88 A9D56610_Vigi Earth Fault Protection Schneider Electric +A1


D D
100577 1 E-25.335.15 FSUP 404008 Electrical housing Stainless 400x400x80 ENSTO +A2

100526 1 E-25.798.48 NSYCCOTHO Cabinet thermostat 1NO Schneider Electric +A1

100632 1 E-25.994.06 PS 99-8-M Housing, 94x94x81mm, IP66 Solar +A1

100515 1 E-31.160.78 GV2L07 motor circuit breaker GV2-L - 2.5A - 3P 3d magnetic trip unit Schneider Electric +A1

100491 3 E-31.160.82 GV2L10 Motor circuit breaker GV2-L - 6.3 A - 3P 3d magnetic trip unit Schneider Electric +A1

E 100408 1 E-31.165.08 GV2ME05 Motor circuit breaker 0.63..1 A 3P 3d - thermomagnetic trip unit Schneider Electric +A1 E

100409 1 E-31.165.12 GV2ME07 Motor overload switch 1.6-2.5 A Schneider Electric +A1

100407 2 E-31.166.42 GVAN11 Auxiliary contact 1 NO + 1 NC Schneider Electric +A1

100500 2 E-31.880.41 GV3L32 Motor circuit breaker GV3-L - 32A - 3P Magnetic trip unit Schneider Electric +A1

100451 1 E-31.880.44 GV3L65 Motor circuit breaker GV3-L - 65A - 3P Magnetic trip unit Schneider Electric +A1

100492 2 E-32.318.30 LC1F265 Main contactor 265A 132kW Schneider Electric +A1

F F

IQF-Actual-Parts_list2
Printed: 2015-03-31
Previous page: 4-001 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 4-003 + 4
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Parts list E60-7173 4-002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Parts list
IQF number. Quantity E-number Type number Designation: Designation 2: Manufactor: Placement:
A manufactor: A

100809 1 E-32.318.40 LC1F400 Main contactor 400A 200kW Schneider Electric +A1

100404 4 E-32.322.91 LAD7B106 Mounting block for LRD01-35 Schneider Electric +A1

100422 4 E-32.332.21 LC1D09BL Contactor TeSys LC1-D - 3P - AC-3 440V 9 A coil 24 V DC Schneider Electric +A1

100406 2 E-32.343.10 LRD06 Thermal overload relay for motor 1..1.7 A 1..1.7 A - class 10A Schneider Electric +A1

100450 2 E-32.343.28 LRD32 Thermal overload relay for motor 23..32A 23..32A - class 10A Schneider Electric +A1

B B
100810 1 E-32.442.34 LX1FJ220 Contactor coil 230VAC for LC1F400 Schneider Electric +A1

100393 2 E-33.444.20 ATV71HU30N4Z Altivar 71: 3kW Variable Speed Drive 3-phase supply voltage: 3kW 380...480V 50/60Hz Schneider Electric +A1

100396 1 E-33.450.22 ATV312H037N4 Altivar 312: 0,37kW Variable Speed Drive 3-phase supply voltage: 0,37kW 380...480V 50/60Hz Schneider Electric +A1

100519 2 E-33.450.70 ATV212HD15N4 Altivar 212: 15kW Variable Speed Drive 3-phase supply voltage: 15kW 380...480V 50/60Hz Schneider Electric +A1

100392 2 E-33.450.72 ATV212HD22N4 Schneider Electric +A1

100452 2 E-33.450.73 ATV212HD30N4 Altivar 212: 30kW Variable Speed Drive 3-phase supply voltage: 30kW 380...480V 50/60Hz Schneider Electric +A1
C C
100394 1 E-33.476.46 VW3A1101 Graphic display for ATV61/71 Schneider Electric +A1

100395 2 E-33.476.76 VW3A3501 Controller inside card Schneider Electric +A1

100659 1 E-37.327.25 ZB4BA2 Round pushbutton, Black Harmony XB4 series, without body collar Schneider Electric +JB2

100622 1 E-37.327.28 ZB4 BA5 Round pushbutton, Yellow Harmony XB4 series, without body collar Schneider Electric +A1

100670 2 E-37.328.35 ZB4BS844 Emergency stop mushroom button 40mm, twist-release Harmony XB4 series, without body collar Schneider Electric +A2;+JB2

100623 1 E-37.328.74 ZB4BG2 Key switch, 0-1 Harmony XB4 series, without body collar Schneider Electric +JB2
D D
100460 1 E-37.331.01 ZB4BW333 Green head for illuminated pushbutton Harmony XB4 series, without body collar Schneider Electric +JB2

100664 4 E-37.331.95 ZBE101 1NO block Harmony XB4 series, for body collar Schneider Electric +A1;+JB2

100458 4 E-37.331.96 ZBE102 1NC Block Harmony XB4 series, for body collar Schneider Electric +A2;+JB2

100665 1 E-37.332.04 ZBVB3 Green LED block 24V Harmony XB4 series, without body collar Schneider Electric +JB2

100666 6 E-37.332.55 ZB4BZ009 Body/fixing collar Harmony XB4 series Schneider Electric +A1;+A2;+JB2

E 100431 2 E-37.347.23 XAL-K178F Emergencystop box, without text, 2 NC Schneider Electric +JB6 E

100410 1 E-38.799.02 XPSAC5121P Preventa safety module Schneider Electric +A1

100411 23 E-40.276.24 RPM12BD Interface relay 1CO Schneider Electric +A1

100412 20 E-40.276.31 RPZF1 Mounting socket for RPM 1CO Schneider Electric +A1

100416 1 E-40.277.86 RXM3AB2BD Zelio Interface relay 3CO Schneider Electric +A1

100415 1 E-40.278.16 RXZE2S111M Mounting socket for RXM 3CO Schneider Electric +A1

F F

IQF-Actual-Parts_list2
Printed: 2015-03-31
Previous page: 4-002 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 4-004 + 4
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Parts list E60-7173 4-003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Parts list
IQF number. Quantity E-number Type number Designation: Designation 2: Manufactor: Placement:
A manufactor: A

100432 1 E-45.003.53 6ES7313-5BG04-0AB0 CPU 313C 64KB DI24/DQ16+AI5/AQ2 Siemens +A1

100434 1 E-45.004.51 6ES7953-8LF20-0AA0 MICRO MEMORY CARD 64KB Siemens +A1

100437 3 E-45.005.10 6ES7321-1BH02-0AA0 S7-300 SM 321 16DI Siemens +A1

100439 2 E-45.005.52 6ES7322-1BH01-0AA0 S7-300, SM 322 16DO Siemens +A1

100440 2 E-45.006.24 6ES7332-5HB01-0AB0 S7-300, SM 332 2AO Siemens +A1

B B
100438 7 E-45.007.70 S7-392-1AJ00-0AA0 20 pin Terminal Siemens +A1

100436 2 E-45.007.75 S7-392-1AM00-0AA0 40 pin Terminal Siemens +A1

100433 1 E-45.008.42 6ES7390-1AE80-0AA0 S7-300, rail 480mm Siemens +A1

100435 1 E-45.009.15 6ES7972-0BB12-0XA0 PB/MPI-CONTACT 12 MB/S 90G PG Siemens +A1

100489 1 E-45.039.10 6AV6 647-0AE11-3AX0 Operator panel 10,4" KTP1000 DP Profibus Siemens +A2

100442 1 E-45.064.14 6GKI500-0FC10 PB/MPI CONTACT 12MB STRAIGHT FC Siemens +A2


C C
100879 1 E-51.673.31 100-310 Patch Cable UTP Solar +A1

100424 2 E-52.030.83 ABT 7PDU100G Transformer Upri(V): 440-400 Usec(V): 2x115 V Schneider Electric +A1;+A1-
Upri(V): 550-525-500-480-460-440-415-400-380-230-208
100494 1 E-52.056.29 4AM5742-8DD40-0FA0 SITAS 1 phase multitransformer Siemens +A1
Usec(V): 2x115 V
100425 1 E-52.130.93 ABL4RSM24050 Power supply unit, 24VDC 5A 1-phase 120-230VAC (96-264V), 47...63 Hz Schneider Electric +A1

100910 2 EMCDS20126 EMCDS20126 Cabinet +A1 ELDON +A1

101043 2 Omron Omron, AX-REM00K6100-IE Braking resistor for VFD, 100 ohm 1,6kW Schneider Electric +A1
D D
100914 1 PFS2120 PFS2120 Base/plinth SS front&rear ELDON +A1

100898 1 PS2050 PS2050 Baseplint trim side ELDON +A1

100915 1 PSS2060 PSS2060 Base/plinth multi k front&rear ELDON +A1

100911 1 SPMS2006 SPMS2006 Side panels SS ELDON +A1

E E

F F

IQF-Actual-Parts_list2
Printed: 2015-03-31
Previous page: 4-003 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +8/8-001 + 4
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Parts list E60-7173 4-004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W101 4G6 FLEX YSY-JZ (SHIELDED) FAN 1 A

Target designation from: Target designation to:


Sheet Sheet

-W101
B B

/034b.1:D +A1 -X1:101 1 1 +JB2-X1:101 /034b.1:E


/034b.2:D +A1 -X1:102 2 2 +JB2-X1:102 /034b.2:E
/034b.2:D +A1 -X1:103 3 3 +JB2-X1:103 /034b.2:E

C /034b.2:D +A1 -X1:104 GNYE GNYE +JB2-X1:104 /034b.2:E C

/034b.2:D +A1 -X1:Shield SH SH -W101:SH /034b.1:D

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: +4/4-004 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-002 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W102 4G6 FLEX YSY-JZ (SHIELDED) FAN 2 A

Target designation from: Target designation to:


Sheet Sheet

-W102
B B

/035b.1:E +JB2 +JB2-X1:105 1 1 -X1:105 /035b.1:D


/035b.2:E +JB2 +JB2-X1:106 2 2 -X1:106 /035b.2:D
/035b.2:E +JB2 +JB2-X1:107 3 3 -X1:107 /035b.2:D

C /035b.2:E +JB2 +JB2-X1:108 GNYE GNYE -X1:108 /035b.2:D C

/035b.1:D +A1 -W102:SH SH SH -X1:Shield /035b.2:D

IMPORTANT !!! SHIELD HAS TO BE CONNECTED IN BOTH ENDS ACCORDING TO EMC-SPEC.

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-001 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-003 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W103 4G6 FLEX YSY-JZ (SHIELDED) FAN 3 A

Target designation from: Target designation to:


Sheet Sheet

-W103
B B

/036b.1:D +A1 -F323:2 1 1 +JB2-X1:109 /036b.1:E


/036b.1:D +A1 -F323:4 2 2 +JB2-X1:110 /036b.2:E
/036b.1:D +A1 -F323:6 3 3 +JB2-X1:111 /036b.2:E

C /036b.2:D +A1 -X1:112 GNYE GNYE +JB2-X1:112 /036b.2:E C

/036b.2:D +A1 -X1:Shield SH SH -W103:SH /036b.1:D

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-002 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-004 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W104 4G6 FLEX YSY-JZ (SHIELDED) FAN 4 A

Target designation from: Target designation to:


Sheet Sheet

-W104
B B

/036b.3:D +A1 -F325:2 1 1 +JB2-X1:113 /036b.3:E


/036b.3:D +A1 -F325:4 2 2 +JB2-X1:114 /036b.3:E
/036b.3:D +A1 -F325:6 3 3 +JB2-X1:115 /036b.3:E

C /036b.4:D +A1 -X1:116 GNYE GNYE +JB2-X1:116 /036b.4:E C

/036b.4:D +A1 -X1:Shield SH SH -W104:SH /036b.3:D

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-003 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-015 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W115 4G1,5 FLEX Y-JZ LATERAL DOOR INLET- F602 A

Target designation from: Target designation to:


Sheet Sheet

-W115
B B

/031.1:D +A1 -X1:151 1 1 +JB2-X1:151 /031.1:E


/031.2:D +A1 -X1:152 2 2 +JB2-X1:152 /031.2:E
/031.2:D +A1 -X1:153 3 3 +JB2-X1:153 /031.2:E

C /031.2:D +A1 -PE:10 GNYE GNYE +JB2-PE:PE /031.2:E C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-004 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-016 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-015
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W116 4G1,5 FLEX Y-JZ LATERAL DOOR OUTLET - F604 A

Target designation from: Target designation to:


Sheet Sheet

-W116
B B

/031.3:D +A1 -X1:154 1 1 +JB2-X1:154 /031.3:E


/031.3:D +A1 -X1:155 2 2 +JB2-X1:155 /031.3:E
/031.3:D +A1 -X1:156 3 3 +JB2-X1:156 /031.3:E

C /031.3:D +A1 -PE:11 GNYE GNYE +JB2-PE:PE /031.3:E C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-015 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-017 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-016
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W117 4G1,5 FLEX Y-JZ SRS A

Target designation from: Target designation to:


Sheet Sheet

-W117
B B

/032.1:E +A1 -X1:161 1 1 +JB2-X1:161 /032.1:E


/032.2:E +A1 -X1:162 2 2 +JB2-X1:162 /032.2:E
/032.2:E +A1 -X1:163 3 3 +JB2-X1:163 /032.2:E

C /032.2:E +A1 -PE:12 GNYE GNYE +JB2-PE:PE /032.2:E C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-016 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-018 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-017
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W118 4G1,5 FLEX Y-JZ (SHIELDED) BED 1 -D401 A

Target designation from: Target designation to:


Sheet Sheet

-W118
B B

/041.1:D +A1 -D401:T1 1 1 +JB2-X1:181 /041.1:E


/041.1:D +A1 -D401:T2 2 2 +JB2-X1:182 /041.1:E
/041.2:D +A1 -D401:T3 3 3 +JB2-X1:183 /041.2:E

C /041.2:D +A1 -D401:PE2 GNYE GNYE +JB2-X1:184 /041.2:E C

/041.2:D +A1 -D401:PE2 SH SH -W118:SH /041.1:E

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-017 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-019 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-018
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W119 4G1,5 FLEX Y-JZ (SHIELDED) BED 2 -D411 A

Target designation from: Target designation to:


Sheet Sheet

-W119
B B

/042.1:D +A1 -D411:T1 1 1 +JB2-X1:185 /042.1:E


/042.1:D +A1 -D411:T2 2 2 +JB2-X1:186 /042.1:E
/042.2:D +A1 -D411:T3 3 3 +JB2-X1:187 /042.2:E

C /042.2:D +A1 -D411:PE2 GNYE GNYE +JB2-X1:188 /042.2:E C

/042.2:D +A1 -D411:PE2 SH SH -W119:SH /042.1:E

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-018 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-020 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-019
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W121 24x2x0,5 FKAR-PG 24V SIGNALS A

Target designation from: Target designation to:


Sheet Sheet

-W121
B B

/005.5:A +A1 -X4:411 1 1 +JB2-X4:411 /005.5:A


/005.4:C +A1 -X4:412 2 2 +JB2-X4:412 /005.4:C
/005.5:C +A1 -X4:414 3 3 +JB2-X4:414 /005.5:C

C /005.5:C +A1 -X4:417 4 4 +JB2-X4:417 /005.5:C C

/005.6:C +A1 -X4:419 5 5 +JB2-X4:419 /005.6:C


/005.7:C +A1 -X4:420 6 6 +JB2-X4:420 /005.7:C
/031.7:B +A1 -X4:427 7 7 +JB2-X4:427 /031.7:B
/031.8:B +A1 -X4:428 8 8 +JB2-X4:428 /031.8:B
/031.7:C +A1 -X4:429 9 9 +JB2-X4:429 /031.7:D
D /033.6:B +A1 -X4:431 10 10 +JB2-X4:431 /033.6:B D

/033.6:B +A1 -X4:432 11 11 +JB2-X4:432 /033.6:B


/033.7:B +A1 -X4:433 12 12 +JB2-X4:433 /033.7:B
/041.6:B +A1 -X4:434 13 13 +JB2-X4:434 /041.6:A
/041.6:B +A1 -X4:435 14 14 +JB2-X4:435 /041.6:A
/041.6:B +A1 -X4:436 15 15 +JB2-X4:436 /041.6:A
E E
/042.6:B +A1 -X4:437 16 16 +JB2-X4:437 /042.6:A
/042.6:B +A1 -X4:438 17 17 +JB2-X4:438 /042.6:A
/042.6:B +A1 -X4:439 18 18 +JB2-X4:439 /042.6:A
/026.2:D +A1 -X4:446 19 19 +JB2-X4:446 /026.2:C
/026.2:D +A1 -X4:447 20 20 +JB2-X4:447 /026.2:C

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-019 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-021 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-020
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W121 24x2x0,5 FKAR-PG 24V SIGNALS A

Target designation from: Target designation to:


Sheet Sheet

-W121
B B

/026.4:D +A1 -X4:448 21 21 +JB2-X4:448 /026.4:C


/026.5:D +A1 -X4:449 22 22 +JB2-X4:449 /026.5:C
23 23

24 24
C C

/016.4:B +A1 -X4:452 25 25 +JB2-X4:452 /016.4:C


/017.4:B +A1 -X4:454 26 26 +JB2-X4:454 /017.4:C
27 27

/018.4:B +A1 -X4:458 28 28 +JB2-X4:458 /018.4:C


/019.4:B +A1 -X4:460 29 29 +JB2-X4:460 /019.4:C
D 30 30 D

/020.4:B +A1 -X4:464 31 31 +JB2-X4:464 /020.4:C


32 32

33 33

34 34

35 35

E 36 36
E

/032.5:B +A1 -X4:485 37 37 +JB2-X4:485 /032.5:B


/032.5:B +A1 -X4:488 38 38 +JB2-X4:488 /032.5:B
/026.6:D +A1 -X4:491 39 39 +JB2-X4:491 /026.6:C
/026.6:D +A1 -X4:492 40 40 +JB2-X4:492 /026.6:C

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-020 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-022 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-021
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W121 24x2x0,5 FKAR-PG 24V SIGNALS A

Target designation from: Target designation to:


Sheet Sheet

-W121
B B

/026.7:D +A1 -X4:493 41 41 +JB2-X4:493 /026.7:C


/026.7:D +A1 -X4:494 42 42 +JB2-X4:494 /026.7:C
43 43

44 44
C C
45 45

46 46

47 47

48 48

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-021 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-023 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-022
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W122 7x0,75 FLEX Y-OZ EMERGENCY-STOP A

Target designation from: Target designation to:


Sheet Sheet

-W122
B B

/004.2:C +A1 -X4:352 1 1 +JB2-X4:352 /004.2:C


/004.4:C +A1 -X4:357 2 2 +JB2-X4:357 /004.5:C
/005.3:A +A1 -X4:359 3 3 +JB2-X4:359 /005.3:A

C /005.3:C +A1 -X4:360 4 4 +JB2-X4:360 /005.3:C C

/005.3:C +A1 -X4:362 5 5 +JB2-X4:362 /005.3:C


/005.4:C +A1 -X4:364 6 6 +JB2-X4:364 /005.4:C
7 7

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-022 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-024 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-023
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W123 2x0,64 UNITRONIC BUS PROFIBUS OP A

Target designation from: Target designation to:


Sheet Sheet

-W123
B B

/006.2:C +A1 -A0:11:RD RD RD +A2-D20:RD /006.2:F


/006.2:C +A1 -A0:11:GR GR GR +A2-D20:GR /006.2:F

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-023 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-025 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-024
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W124 2x0,75 FLEX Y-OZ POWER OP A

Target designation from: Target designation to:


Sheet Sheet

-W124
B B

/006.2:E +A1 -X4:481 1 1 +A2-D20:24Vdc(L+) /006.2:F


/006.2:E +A1 -X4:482 2 2 +A2-D20:0Vdc(M) /006.2:F

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-024 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-027 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-025
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+A1-W500 1x16 RK2 EARTH A

Target designation from: Target designation to:


Sheet Sheet

-W500
B B

/008.2:C +A1 -PE GNYE GNYE +JB2-PE /008.7:C

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-025 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-028 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-027
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W301 4G6 FLEX YSY-JZ (SHIELDED) FAN 1 A

Target designation from: Target designation to:


Sheet Sheet

-W301
B B

+A1/034b.1:E +JB2 -X1:101 1 1 +VFD1-M304:U1 +A1/034b.1:F


+A1/034b.2:E +JB2 -X1:102 2 2 +VFD1-M304:V1 +A1/034b.1:F
+A1/034b.2:E +JB2 -X1:103 3 3 +VFD1-M304:W1 +A1/034b.1:F

C +A1/034b.2:E +JB2 -X1:104 GNYE GNYE +VFD1-M304:PE +A1/034b.1:F C

+A1/034b.2:E +JB2 -PE SH SH +VFD1-PE +A1/034b.2:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-027 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-029 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-028
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W302 4G6 FLEX YSY-JZ (SHIELDED) FAN 2 A

Target designation from: Target designation to:


Sheet Sheet

-W302
B B

+A1/035b.1:E +JB2 -X1:105 1 1 +VFD2-M314:U1 +A1/035b.1:F


+A1/035b.2:E +JB2 -X1:106 2 2 +VFD2-M314:V1 +A1/035b.1:F
+A1/035b.2:E +JB2 -X1:107 3 3 +VFD2-M314:W1 +A1/035b.1:F

C +A1/035b.2:E +JB2 -X1:108 GNYE GNYE +VFD2-M314:PE +A1/035b.1:F C

+A1/035b.2:E +JB2 -PE SH SH +VFD2-PE +A1/035b.2:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-028 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-030 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-029
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W303 4G6 FLEX YSY-JZ (SHIELDED) FAN 3 A

Target designation from: Target designation to:


Sheet Sheet

-W303
B B

+A1/036b.1:E +JB2 -X1:109 1 1 +VFD3-M324:U1 +A1/036b.1:F


+A1/036b.2:E +JB2 -X1:110 2 2 +VFD3-M324:V1 +A1/036b.1:F
+A1/036b.2:E +JB2 -X1:111 3 3 +VFD3-M324:W1 +A1/036b.1:F

C +A1/036b.2:E +JB2 -X1:112 GNYE GNYE +VFD3-M324:PE +A1/036b.1:F C

+A1/036b.2:E +JB2 -PE SH SH +VFD3-PE +A1/036b.2:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-029 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-031 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-030
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W304 4G6 FLEX YSY-JZ (SHIELDED) FAN 4 A

Target designation from: Target designation to:


Sheet Sheet

-W304
B B

+A1/036b.3:E +JB2 -X1:113 1 1 +VFD3-M326:U1 +A1/036b.3:F


+A1/036b.3:E +JB2 -X1:114 2 2 +VFD3-M326:V1 +A1/036b.3:F
+A1/036b.3:E +JB2 -X1:115 3 3 +VFD3-M326:W1 +A1/036b.3:F

C +A1/036b.4:E +JB2 -X1:116 GNYE GNYE +VFD3-M326:PE +A1/036b.3:F C

+A1/036b.4:E +JB2 -PE SH SH +VFD3-PE +A1/036b.4:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-030 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-042 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-031
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W315 4G1,5 FLEX Y-JZ LATERAL DOOR INLET -M605 A

Target designation from: Target designation to:


Sheet Sheet

-W315
B B

+A1/031.1:E +JB2 -X1:151 1 1 +LATERALDOORINLET-M605:U1 +A1/031.1:E


+A1/031.2:E +JB2 -X1:152 2 2 +LATERALDOORINLET-M605:V1 +A1/031.1:E
+A1/031.2:E +JB2 -X1:153 3 3 +LATERALDOORINLET-M605:W1 +A1/031.1:E

C +A1/031.2:E +JB2 -PE:PE GNYE GNYE +LATERALDOORINLET-M605:PE +A1/031.1:E C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-031 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-043 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-042
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W316 4G1,5 FLEX Y-JZ LATERAL DOOR OUTLET -M606 A

Target designation from: Target designation to:


Sheet Sheet

-W316
B B

+A1/031.3:E +JB2 -X1:154 1 1 +LATERALDOOROUTLET-M606:U1 +A1/031.3:E


+A1/031.3:E +JB2 -X1:155 2 2 +LATERALDOOROUTLET-M606:V1 +A1/031.3:E
+A1/031.3:E +JB2 -X1:156 3 3 +LATERALDOOROUTLET-M606:W1 +A1/031.3:E

C +A1/031.3:E +JB2 -PE:PE GNYE GNYE +LATERALDOOROUTLET-M606:PE +A1/031.3:E C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-042 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-044 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-043
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W317 4G1,5 FLEX Y-JZ SRS -M610 A

Target designation from: Target designation to:


Sheet Sheet

-W317
B B

+A1/032.1:E +JB2 -X1:161 1 1 +SRS-M610:U1 +A1/032.1:F


+A1/032.2:E +JB2 -X1:162 2 2 +SRS-M610:V1 +A1/032.1:F
+A1/032.2:E +JB2 -X1:163 3 3 +SRS-M610:W1 +A1/032.1:F

C +A1/032.2:E +JB2 -PE:PE GNYE GNYE +SRS-M610:PE +A1/032.1:F C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-043 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-045 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-044
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W318 4G1,5 FLEX Y-JZ (SHIELDED) BED 1 -M402 A

Target designation from: Target designation to:


Sheet Sheet

-W318
B B

+A1/041.1:E +JB2 -X1:181 1 1 +BED1-M402:U1 +A1/041.1:F


+A1/041.1:E +JB2 -X1:182 2 2 +BED1-M402:V1 +A1/041.1:F
+A1/041.2:E +JB2 -X1:183 3 3 +BED1-M402:W1 +A1/041.1:F

C +A1/041.2:E +JB2 -X1:184 GNYE GNYE +BED1-M402:PE +A1/041.1:F C

+A1/041.2:E +JB2 -PE SH SH +BED1-PE +A1/041.2:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-044 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-046 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-045
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W319 4G1,5 FLEX Y-JZ (SHIELDED) BED 2 -M411 A

Target designation from: Target designation to:


Sheet Sheet

-W319
B B

+A1/042.1:E +JB2 -X1:185 1 1 +BED2-M411:U1 +A1/042.1:F


+A1/042.1:E +JB2 -X1:186 2 2 +BED2-M411:V1 +A1/042.1:F
+A1/042.2:E +JB2 -X1:187 3 3 +BED2-M411:W1 +A1/042.1:F

C +A1/042.2:E +JB2 -X1:188 GNYE GNYE +BED2-M411:PE +A1/042.1:F C

+A1/042.2:E +JB2 -PE SH SH +BED2-PE +A1/042.2:F

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-045 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-047 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-046
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W401 2x0,75 FLEX Y-OZ TEMP ABOVE BED A

Target designation from: Target designation to:


Sheet Sheet

-W401
B B

+A1/026.2:C +JB2 -X4:446 1 1 +ABOVE_BED-B401:4+ +A1/026.2:A


+A1/026.2:C +JB2 -X4:447 2 2 +ABOVE_BED-B401:5- +A1/026.2:A

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-046 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-048 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-047
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W402 2x0,75 FLEX Y-OZ TEMP UNDER BED A

Target designation from: Target designation to:


Sheet Sheet

-W402
B B

+A1/026.4:C +JB2 -X4:448 1 1 +BELOW_BED-B402:4+ +A1/026.4:A


+A1/026.5:C +JB2 -X4:449 2 2 +BELOW_BED-B402:5- +A1/026.4:A

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-047 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-049 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-048
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W403 4x0,75 FLEX Y-OZ TEMP COOLING MEDIA A

Target designation from: Target designation to:


Sheet Sheet

-W403
B B

+A1/026.6:B +COOLING_MEDIA +COOLING_MEDIA-B403:WH


1 1 -B12:41 +A1/026.6:C
+A1/026.7:B +COOLING_MEDIA +COOLING_MEDIA-B403:BK
2 2 -B12:42 +A1/026.7:C
+A1/026.7:B +COOLING_MEDIA +COOLING_MEDIA-B403:RD
3 3 -B12:43 +A1/026.7:C

C +A1/026.7:B +COOLING_MEDIA +COOLING_MEDIA-B403:BL


4 4 -B12:44 +A1/026.7:C C

+A1/026.7:B +JB2 -PE SH SH -W403 +A1/026.6:B

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-048 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-050 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-049
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W404 4x0,34 EVM012 DOOR INLET SENSOR 25 m
A

Target designation from: Target designation to:


Sheet Sheet

-W404
B B

+A1/005.5:A +JB2 -X4:413 BN BN +INLETDOOR-S404:BN +A1/005.5:B


+A1/005.5:C +JB2 -X4:415 BU BU +INLETDOOR-S404:BU +A1/005.5:B
+A1/005.5:C +JB2 -X4:414 BK BK +INLETDOOR-S404:BK +A1/005.5:B
WH WH
C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-049 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-051 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-050
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W405 4x0,34 EVM012 DOOR OUTLET SENSOR 25 m
A

Target designation from: Target designation to:


Sheet Sheet

-W405
B B

+A1/005.5:A +JB2 -X4:416 BN BN +OUTLETDOOR-S405:BN +A1/005.5:B


+A1/005.5:C +JB2 -X4:415 BU BU +OUTLETDOOR-S405:BU +A1/005.5:B
+A1/005.5:C +JB2 -X4:417 BK BK +OUTLETDOOR-S405:BK +A1/005.5:B
WH WH
C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-050 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-052 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-051
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W406 2x0,75 FLEX Y-OZ LATERAL DOOR SENSOR A

Target designation from: Target designation to:


Sheet Sheet

-W406
B B

+A1/005.6:A +JB2 -X4:418 1 1 +LATERALDOOR-S406:1/3 +A1/005.6:B


+A1/005.6:C +JB2 -X4:419 2 2 +LATERALDOOR-S406:2/4 +A1/005.6:B

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-051 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-053 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-052
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W410 3G1 KMEB-1-24-5-LED MAIN AIR/DEC. AIRVALVE 5m
A

Target designation from: Target designation to:


Sheet Sheet

-W410
B B

+A1/016.4:C +JB2 -X4:452 1 1 +AIRVALVE-Y410:X1 +A1/016.4:D


+A1/016.4:D +JB2 -X4:453 2 2 +AIRVALVE-Y410:X2 +A1/016.4:D
+A1/016.5:D +AIRVALVE +AIRVALVE-PE PE PE -PE +A1/016.5:D

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-052 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-054 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-053
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W411 3x0,34 EVM006 PROXIMITY SENSOR BED 1 A

Target designation from: Target designation to:


Sheet Sheet

-W411
B B

+A1/041.6:A +JB2 -X4:434 BN BN +BED1-S411:BN +A1/041.7:A


+A1/041.6:A +JB2 -X4:435 BU BU +BED1-S411:BU +A1/041.7:A
+A1/041.6:A +JB2 -X4:436 BK BK +BED1-S411:BK +A1/041.7:A
WH WH
C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-053 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-055 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-054
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W412 3x0,34 EVM005 PROXIMITY SENSOR BED 2 A

Target designation from: Target designation to:


Sheet Sheet

-W412
B B

+A1/042.6:A +JB2 -X4:437 BN BN +BED2-S412:BN +A1/042.7:A


+A1/042.6:A +JB2 -X4:438 BU BU +BED2-S412:BU +A1/042.7:A
+A1/042.6:A +JB2 -X4:439 BK BK +BED2-S412:BK +A1/042.7:A
WH WH
C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-054 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-056 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-055
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W413 3G1 KMEB-1-24-5-LED VIBRATOR. AIRVALVE A

Target designation from: Target designation to:


Sheet Sheet

-W413
B B

+A1/018.4:C +JB2 -X4:458 1 1 +VIBRATOR-Y413:X1 +A1/018.4:D


+A1/018.4:D +JB2 -X4:459 2 2 +VIBRATOR-Y413:X2 +A1/018.4:D
+A1/018.5:D +JB2 -PE PE PE +VIBRATOR-Y413:PE +A1/018.5:D

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-055 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-057 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-056
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W414 3G1 KMEB-1-24-5-LED DAM 1 A

Target designation from: Target designation to:


Sheet Sheet

-W414
B B

+A1/017.4:C +JB2 -X4:454 1 1 +DAM1-Y414:X1 +A1/017.4:D


+A1/017.4:D +JB2 -X4:455 2 2 +DAM1-Y414:X2 +A1/017.4:D
+A1/017.5:E +JB2 -PE PE PE +DAM1-Y414:PE +A1/017.5:D

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-056 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-059 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-057
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W416 2x0,75 FLEX Y-OZ CCS WATER 1 A

Target designation from: Target designation to:


Sheet Sheet

-W416
B B

+A1/019.4:C +JB2 -X4:460 1 1 +CCS-Y416:X1 +A1/019.4:D


+A1/019.4:D +JB2 -X4:461 2 2 +CCS-Y416:X2 +A1/019.4:D

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-057 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-060 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-059
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W417 2x0,75 FLEX Y-OZ SRS AIR1 A

Target designation from: Target designation to:


Sheet Sheet

-W417
B B

+A1/020.4:C +JB2 -X4:464 1 1 +SRS-Y417:X1 +A1/020.4:D


+A1/020.4:D +JB2 -X4:465 2 2 +SRS-Y417:X2 +A1/020.4:D

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-059 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-063 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-060
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W422 4x0,75 FLEX Y-OZ EMERGENCY-STOP +JB6 A

Target designation from: Target designation to:


Sheet Sheet

-W422
B B

+A1/004.2:C +JB2 -X4:352 1 1 +JB6-S418:12 +A1/004.2:B


+A1/004.2:C +JB2 -X4:353 2 2 +JB6-S418:11 +A1/004.2:B
+A1/005.3:A +JB2 -X4:359 3 3 +JB6-S418:21 +A1/005.3:B

C +A1/005.3:C +JB2 -X4:360 4 4 +JB6-S418:22 +A1/005.3:B C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-060 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-064 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-063
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W423 4x0,75 FLEX Y-OZ EMERGENCY-STOP +A2 A

Target designation from: Target designation to:


Sheet Sheet

-W423
B B

+A1/004.3:C +JB2 -X4:354 1 1 +A2-S419:1 +A1/004.3:B


+A1/004.4:C +JB2 -X4:355 2 2 +A2-S419:2 +A1/004.3:B
+A1/005.3:A +JB2 -X4:361 3 3 +A2-S419:1 +A1/005.3:B

C +A1/005.3:C +JB2 -X4:362 4 4 +A2-S419:2 +A1/005.3:B C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-063 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-065 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-064
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W424 3x0,75 FLEX Y-OZ SRS INLET A

Target designation from: Target designation to:


Sheet Sheet

-W424
B B

+A1/032.5:A +JB2 -X4:483 1 1 +SRS-S424:BN +A1/032.5:B


+A1/032.5:A +JB2 -X4:484 2 2 +SRS-S424:BU +A1/032.5:B
+A1/032.5:B +JB2 -X4:485 3 3 +SRS-S424:BK +A1/032.5:B

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-064 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 8-066 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-065
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Cable diagram
No. & size of conductors: Cable type: Function text Length
A =RK+JB2-W425 3x0,75 FLEX Y-OZ SRS OUTLET A

Target designation from: Target designation to:


Sheet Sheet

-W425
B B

+A1/032.5:A +JB2 -X4:486 1 1 +SRS-S425:BN +A1/032.5:B


+A1/032.6:A +JB2 -X4:487 2 2 +SRS-S425:BU +A1/032.5:B
+A1/032.5:B +JB2 -X4:488 3 3 +SRS-S425:BK +A1/032.5:B

C C

D D

E E

IQF-Cable_diagram-actual
F F
Printed: 2015-03-31
Previous page: 8-065 = DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: =RK+A1/001 + 8
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Cable diagram E60-7173 8-066
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

1,5mm2 1,5mm2

L10

L20

L30

L11

L31

L12

L22

L32
031.1:A /

031.1:A /

031.1:A /

002.1:A /

002.1:A /

001b.1:A /

001b.1:A /

001b.1:A /
B B
PE:1
L1 L2 L3
-Q01
MCCB
160A SUPPLY SUPPLY SUPPLY
MAIN SWITCH I> I> I> -X0 N PE
LATERAL CONTROL THROUGH MAIN
L1 L2 L3
DOOR VOLTAGE CONTACTOR
0,5kW
MAX AMPERAGE:
200A

C C

POWER SUPPLY
CONNECTS DIRECTLY
TO MAIN SWITCH

MOLDED CASE CIRCUIT BREAKER


DESIGNED FOR 25kA SHORT CIRCUIT CURRENT

D D

POWER SUPPLY
440 VAC/ 60Hz

E E

F F
Printed: 2015-03-31
Previous page: =DOCUMENTS+8/8-066 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 001b + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Power supply E60-7173 001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001.5:B / L12

001.5:B / L22
A A
001.5:B / L32

B B
1 3 5
-Q02
/004.6:E 2 4 6
MAIN CONTACTOR

C C

6mm2 6mm2 6mm2 6mm2 10mm2 10mm2 25mm2


D D
120

220

320

121

221

321

122

222

322

L123

L223

L323

L124

L224

L324

L125

L225

L325

L126

L226

L326
041.1:A /

041.1:A /

041.1:A /

042.1:A /

042.1:A /

042.1:A /

032.1:A /

032.1:A /

032.1:A /

033.1:A /

033.1:A /

033.1:A /

034b.1:A /

034b.1:A /

034b.1:A /

035b.1:A /

035b.1:A /

035b.1:A /

036b.1:A /

036b.1:A /

036b.1:A /
E E
SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY
BED 1 BED 2 SRS WAVEPULSE VFD 1 VFD 2 VFD 3
MOTOR MOTOR
1,1kW 1,1kW 0,18kW 0,18kW 15kW 15kW 30kW

F F
Printed: 2015-03-31
Previous page: 001 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 002 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Power supply E60-7173 001b
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001.4:B / L11

A 001.5:B / L31 A

1/L1 3/L2 5/L3


-F03
6,3A
MCB
230V I> I> I>
CONTROL 2/T1 4/T2 6/T3
VOLTAGE

B 1 2 3 4 5 6 7 8 B

-T04
Transformer
Control voltage 31 32 33 34
480VAC/2x115VAC

N
2,5 mm²

2,5 mm²

PE:2

C C

1 3
-F104
10A, 30mA
ILLUMINATION,

OUTLET
2 4

1 1 1
1
-F101 -F102 -F103
4A 2 6A 2 2A 2 -F106
D MCB MCB MCB 4A 2 D
Main- 24VDC VENTILATION MCB
contactor CONTROL CABINET -X2 OUTLET -X2
-X2 VOLTAGE
-X2

N101 N102 N103 N106 PE:3

L1 PE N

-XU01
L103

N103

10 A
L101

N101

L102

N102

SERVICE
E OUTLET E
014.1:A /

014.1:A /

MAX 4A!
004.1:A /

003.1:A /
004.1:E /

003.1:A /

F F
Printed: 2015-03-31
Previous page: 001b = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 003 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Power supply E60-7173 002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

002.3:E / L102

A 002.3:E / N102 A

PE:4

B B

L N
AC AC
-V110
/003.2:B
120-240 VAC / 24 V / 5 A
RECTIFIER
CONTROL + -
VOLTAGE
2,5 mm²

2,5 mm²

C C

1 1 1 1 1 1
-F200 -F201 -F202 -F203 -F204 -F205
2A 2 2A 2 2A 2 2A 2 2A 2 2A 2
D MCB MCB MCB MCB MCB MCB D
24VDC 24VDC 24VDC 24VDC 24VDC 24VDC
Supply\PLC Supply Supply Supply Supply Supply
OP Digital Digital Analog Emergencystop/
-X5 inputs outputs signals Main24VDC
security
-200 -201 -202 -203 -204 -205 -PE

PE:6
P200

M200

P201

M201

P202

M202

P203

M203

P204

M204

P205

M205
006.1:A /

006.1:B /

004.1:A /

004.1:A /

006.1:B /

014.1:A /
006.1:D /

006.1:D /

005.1:E /

004.1:E /

006.1:C /

014.1:D /
E E

SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY


PLC OP I/O INPUT SECURITY/ ANALOG SIGNALS MAIN 24VDC
(DIGITAL I/O JB2) OUTPUT

F F
Printed: 2015-03-31
Previous page: 002 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 004 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Control Voltage 24VDC E60-7173 003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

002.2:E / L101

003.4:E / P202 P202 / 005.1:A

A 003.4:E / P203 P203 / 005.1:A A

+JB6 +A2

11 2 2

-S418 -S419 -S420


/005.3:B /005.3:B 1 /005.4:B 1
B EMERGENCY
12 EMERGENCY EMERGENCY B
STOP STOP STOP

+JB2

-W422 1 2 -W423 1 2

-X4 352 353 354 355 356 357


12 14 12 14
-K04 -K05
/005.2:D
11 /005.3:D 11
C C

-W122 1 2

61
-X4 352 357
-Q02
JUMPERED WHEN JUMPERED WHEN /004.6:E 62
NOT CONNECTED NOT CONNECTED
TO EXTERNAL TO EXTERNAL
EMERGENCYSTOP-LINE EMERGENCYSTOP-LINE
MAIN-AIR/K03/33 / 016.5:B
-X4 351 SEE MANUAL 358 SEE MANUAL

D D
-K03 A1 Y1 Y2 13 23 33
24 V
SAFETY RELAY
A1/A2 Fuse LED lit when safetystop line is ok

K1/K2 LED lit when safetyrelay is OK

A2 14 24 34

A1 2

-Q02 -A0 I0.0 MAIN-AIR/K03/34 / 016.5:B


400A 200kW A2
E MAIN E
003.5:E / M203 M203 / 005.1:E CONTACTOR SAFETY
RELAY OK
002.2:E / N101

1 2 /001b.3:B
3 4 /001b.3:B
5 6 /001b.3:B
53 54 /005.2:B
61 62 /004.5:C

F F
Printed: 2015-03-31
Previous page: 003 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 005 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Safety relay E60-7173 004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

004.8:A / P203

004.8:A / P202 P202 / 006.1:A

-X4 359 411

A -W122 3 -W121 1 A
/004.2:C

+JB2 -X4 411 JB2-P202 / 021.2:A


-X4 359 361 363 416 418
-X4 413
-W422 3 -W423 3 -W404 BN -W405 BN -W406 1
/004.2:C /004.3:C

+JB6 +A2 +JB2 +INLETDOOR +OUTLETDOOR +LATERALDOOR


53
3
-Q02 BN BU BN BU -S406 1/3
21 1 1
/004.6:E 54 + - + - 15-34 V
-S45
B -S418 -S419 -S420 -S404 -S405 Limitswitch
Key 4 B
/004.2:B 22 /004.3:B 2 /004.4:B 2 Switch
10-60 VDC 10-60 VDC lateral door
Emergencystop Emergencystop Emergencystop Limitswitch BK Limitswitch BK 2/4
outlet controlpanel controlpanel Inlet door Outlet door

-W422 4 -W423 4
-W404 BK BU -W405 BK BU -W406 2
/004.2:C /004.3:C /005.4:A /005.5:A /005.6:A
3
-A0
I0.1 -X4 360 362 364 412 414 415 417 419 420
JB2-M202 / 016.4:E
Main contactor
C -W122 4 5 6
-W121 2 3 4 5 6
C
/004.2:C

-X4 360 362 364 412 414 417 419 420

4 5 12 6 7 8 19
-A0 I0.2 -A0 I0.3 -A0 -A0 -A0 -A0 -A2
I1.0 I0.4 I0.5 I0.6 I6.7
EMERGENCY EMERGENCY EMERGENCY LIMITSWITCH LIMITSWITCH LIMITSWITCH KEY BYPASS
STOP STOP STOP INLET OUTLET LATERAL INLET
OUTLET OP-PANEL INLET DOOR DOOR DOOR DOOR
D -A4 Q2.0 -A0 Q0.0 -A0 Q0.1 D
2 22 23

A1 A1 A1
-K111 -K04 -K05
24VDC 15A A2 24VDC 15A A2 24VDC 15A A2
Reset Main
freezer contactor on

003.4:E / M202 M202 / 006.1:D

004.4:E / M203 M203 / 006.1:D


E E

LIGHT RESET ENABLE


SECURITY MAIN
RELAY CONTACTOR

14 11 14 11 /004.5:C 14 11 /004.6:C
12 12 12

F F
Printed: 2015-03-31
Previous page: 004 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 006 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Secure Circuit E60-7173 005
1 2 3 6 7 8
1 2 3 4 5 6 7 8

SUPPLY PLC
003.2:E / P200
A A
SUPPLY DIGITAL INPUTS
005.8:A / P202 P202 / 013.1:A

SUPPLY DIGITAL OUTPUTS


/ P203

SUPPLY ANALOG SIGNALS


003.5:E / P204 P204 / 026.1:D

SUPPLY OP
003.3:E / P201

B -A0 -A1 -A2 -A4 -A5 -A6 -A7 B


1L+ 1 21 31 1 1 1 11 1 11 1 1

1L+ 2L+ 3L+ 1L+ 1L+ 1L+ 11L+ 1L+ 11L+ 1L+ 1L+

X11 16 DI X12 8 DI
CPU 313C I1.0-2.7 I0.0-0.7
5 AI 16 D0
16 DI 16 DI 16 DO 16 DO 2 AO 2 AO
PIW Q0.0-1.7
I3.0-4.7 I5.0-6.7 Q2.0-3.7 Q4.0-5.7 PQW PQW
2 AO
PQW
C C
4M 1M 2M 3M M M 1M 2M 1M 2M M M

RD GR M 30 20 30 40 20 20 10 20 10 20 20 20

003.5:E / M204 M204 / 026.1:D

005.8:E / M203 M203 / 013.1:D

005.8:E / M202

003.2:E / M200
D D
003.3:E / M201

PE
-X4 482 481

-W124 2 1
GNYE -W123 RD GR

E +A2 E

-D20
OP-PANEL
0Vdc(M)

24Vdc(L+)

PE

RD

GR

F F
Printed: 2015-03-31
Previous page: 005 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 008 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram PLC Configuration E60-7173 006
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

B B

+JB2

16mm

-W500
EARTH GNYE
C C
-PE
/033.2:E
-PE

D D

E E

F F
Printed: 2015-03-31
Previous page: 006 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 013 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Earth +A1 - +JB2 E60-7173 008
1 2 3 6 7 8
1 2 3 4 5 6 7 8

006.8:A / P202 P202 / 031.4:A

-X4 421 423 425


A A

JUMPERED
IF NO
COMPRESSORSIGNAL
SEE MANUAL SEE MANUAL
PRESENT
FOR INFORMATION FOR INFORMATION
SEE MANUAL
FOR INFORMATION

-X4 422 424 426


B B
9 14 19

-A0 I0.7 -A0 I1.2 -A1 I4.7

EXTERNAL RELAY COMPRESSOR EXTERNAL EQUIPMENT


EXTERNAL FOR COOLING ALARM
STANDBY RUNNING OPTIONAL

OPTIONAL OPTIONAL

START EXTERNAL COOLING MEDIA ON HEATING MEDIA EXTERNAL ALARM COOLING LOAD
C EQUIPMENT C

-A0 Q0.2 -A0 Q0.3 -A0 Q0.4 -A0 Q0.5 -A0 Q0.6
24 25 26 27 28

22 24 22 24 32 34
-K208 -K207 -K208
/013.5:D 21 /013.4:D 21 /013.5:D 31

A1 A1 A1 A1 A1
-K206 -K207 -K208 -K209 -K210
INTERFACE RELAY A2 INTERFACE RELAY A2 INTERFACE RELAY A2 INTERFACE RELAY A2 INTERFACE RELAY A2
START EXTERNAL COOLING HOT GAS/DEFROST ALARM COOLING LOAD
EQUIPMENT MEDIA ON ON
D D
006.8:D / M203 M203 / 031.4:E

12 14 12 14 12 14 12 14 12 14
-K206 -K207 -K208 -K209 -K210
/013.3:D 11 /013.4:D 11 /013.5:D 11 /013.6:D 11 /013.6:D 11
E E

-X3 301 302 303 304 305 306 307 308 309 310

14 11 /013.3:E 14 11 /013.4:E 14 11 /013.5:E 14 11 /013.6:E


A1 A2
12 12 12 12
14 11 /013.4:E 24 21 /013.4:D
12 22
24 21 /013.4:D 34 31 /013.6:D
22 32
F F
Printed: 2015-03-31
Previous page: 008 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 014 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram External signals E60-7173 013
1 2 3 6 7 8
1 2 3 4 5 6 7 8

002.4:E / L103

A 002.4:E / N103 A

003.6:E / P205 P205 / 033.1:A

12 14
1 -K110
Θ /014.4:C 11
B B
2

-S110
THERMOSTAT
VENTILATION +A1
Def. 35C°

PE:8
C C

L
A1
M
-K110 -M10 PE
VENTILATION A2 230V 50/60Hz 1~
+A1 VENTILATION +A1
FAN 1 N

D D

003.6:E / M205 M205 / 033.6:E

E E

14 11 /014.5:B
12

F F
Printed: 2015-03-31
Previous page: 013 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 016 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Ventilation +A1 E60-7173 014
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

MAIN AIR/
DECOMPRESSION-
VALVE

-A0 Q1.0
32

MAIN-AIR/K03/33 / 004.8:D

MAIN-AIR/K03/34 / 004.8:E
B B
-X4 452

-W121 25
/005.4:A

+JB2

-X4 452

-W410 1
C C

+AIRVALVE

X1

-Y410 X2
24V PE
Main air/
decompression-
valve

D D

-W410 2 PE
/016.4:C

-X4 453
-PE

005.8:C / JB2-M202 JB2-M202 / 017.4:E

E E

F F
Printed: 2015-03-31
Previous page: 014 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 017 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Main & Decompression Valve E60-7173 016
1 2 3 6 7 8
1 2 3 4 5 6 7 8

OPTIONAL
FUNCTION
A A

PRESENT

DAM 1

-A0 Q1.2
34

B B
-X4 454

-W121 26
/005.4:A

+JB2

-X4 454

C C
-W414 1

+DAM1

X1

-Y414 X2
PE
/017.5:D
24V
Dam 1

D D

-W414 2 PE
/017.4:C

-X4 455

-PE
016.6:E / JB2-M202 JB2-M202 / 018.4:E

E E

F F
Printed: 2015-03-31
Previous page: 016 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 018 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Dam E60-7173 017
1 2 3 6 7 8
1 2 3 4 5 6 7 8

OPTIONAL
FUNCTION
A A

PRESENT

Vibrator 1
Enable
-A5 Q5.3
15
B B

-X4 458

-W121 28

+JB2

-X4 458

C -W413 1
C

+VIBRATOR

X1

-Y413 X2 PE
24V
Vibrator

D D

-W413 2 PE

-X4 459
-PE

017.6:E / JB2-M202 JB2-M202 / 019.3:E

E E

F F
Printed: 2015-03-31
Previous page: 017 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 019 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Vibrator E60-7173 018
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

SRS
WATER 1

-A0 Q1.6
38

B B
-X4 460

-W121 29
/005.4:A

+JB2

-X4 460

-W416 1
C C

+CCS

X1

-Y416 X2
24V, 8W
CCS
Water1

D D

-W416 2
/019.3:C

-X4 461

018.6:E / JB2-M202 JB2-M202 / 020.4:E

E E

F F
Printed: 2015-03-31
Previous page: 018 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 020 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Coil Cleaning E60-7173 019
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

SRS
AIR 1

-A0 Q1.1
33

B B
-X4 464

-W121 31
/005.4:A

+JB2

-X4 464

-W417 1
C C

+SRS

X1

-Y417 X2
24V, 12W
SRS
Air1

D D

-W417 2
/020.4:C

-X4 465

019.6:E / JB2-M202 JB2-M202 / 021.4:E

E E

F F
Printed: 2015-03-31
Previous page: 019 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 021 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Snow remove system E60-7173 020
1 2 3 6 7 8
1 2 3 4 5 6 7 8

OPTIONAL FUNCTION
+JB2

005.8:A / JB2-P202 JB2-P202 / 031.7:A


A
NOT PRESENT A

-X4 471

FOAMING FOAMING FOAMING


+FOAM LIQUID DRYBLOWING AIR

-A0 -A5 -A5


NOT Q1.4 Q4.6 Q4.7
36 8 9
PRESENT
B B

-X4 473 475 476

-X4 472

+JB2

-X4 473 475 476

C C
-X4 472

13
-A0
I1.1

LEVELSWITCH
FOAM +FOAM

D NOT D
PRESENT

E E

-X4 474

020.6:E / JB2-M202 JB2-M202 / 031.7:D

F F
Printed: 2015-03-31
Previous page: 020 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 026 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Foaming E60-7173 021
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A
+ABOVE_BED +BELOW_BED +COOLING_MEDIA

-B403
PT100
-B401 -B402 TEMP
PT100 PT100 COOLING MEDIA
4+ 5- 4+ 5-
TEMP TEMP EXTERNAL WH BK RD BL
ABOVE BED BELOW BED

+JB2

B B

-W403 1 2 3 4 SH

-PE

-B12
31 41 42 43 44

C C
33
12 11

-W401 1 2 -W402 1 2

-X4 446 447 448 449 491 492 493 494

-W121 19 20 21 22 39 40 41 42
/005.4:A
-X4 446 447 448 449 491 492 493 494

D 006.8:B / P204 D
006.8:C / M204

-A0 3 4 6 7 9 10

PIW752 PIW754 PIW756


+ - + - + -
CH0 CH1 CH2

TEMPERATURE TEMPERATURE TEMPERATURE


ABOVE BED BELOW BED MEDIA

E E

F F
Printed: 2015-03-31
Previous page: 021 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 031 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Temperature measure E60-7173 026
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001.4:B / L10 013.8:A / P202 P202 / 032.3:A


+JB2
001.4:B / L20
021.2:A / JB2-P202
A 001.4:B / L30 OPTIONAL A

FUNCTION 3 3
-S43 -S44
1 3 5 43 31 41 4 4
41 97 97
-F600
1.6...2.5 A MCB 44 32 42 -F600 -F602 -F604
Lateral door /031.1:A 42 /031.1:C 98 /031.3:C 98 -X4 427 428

/031.5:A
I> I> I>
2 4 6 PRESENT
-W121 7 8
/005.4:A
-X4 427 428
B B
15 16 17 18 19

-A0 I1.3 -A0 I1.4 -A0 I1.5 -A0 I1.6 -A0 I1.7

1/L1 3/L2 5/L3 1/L1 3/L2 5/L3 THERMAL THERMAL THERMAL OPEN CLOSE
-Q601 -Q603 OVERLOAD OVERLOAD OVERLOAD LATERAL LATERAL
/031.5:D 2/T1 4/T2 6/T3 /031.5:D 2/T1 4/T2 6/T3 LATERAL DOOR LATERAL DOOR LATERAL DOOR DOOR DOOR
BOTH MOTORS INLET SIDE OUTLET SIDE
LATERAL
DOOR
OPEN CLOSE ALLOWED TO
1 3 5 1 3 5
LATERAL DOOR LATERAL DOOR OPEN
-F602 -F604
C /031.5:A /031.6:A Q2.1 Q2.2 Q2.3 C
2 4 6 2 4 6 -A4 -A4 -A4
1..1,6 A 1..1,6 A
MCB THERMAL MCB THERMAL 3 4 5
MOTOR PROTECTION MOTOR PROTECTION
Lateral door Lateral door
Inlet gable Outlet gable -X4 429
-W121 9

21 21 +JB2 /005.4:A

-Q603 -Q601
/031.5:D 22 /031.5:D 22
-X4 429

x1
-H43
24V green LED x2
D LATERAL D
PE:10 PE:11 DOOR
PILOT LIGHT
-X1 151 152 153 154 155 156 -X4 430
A1 A1
-Q601 -Q603 021.7:E / JB2-M202
-W115 -W116 24VDC 9A A2 24VDC 9A A2
1 2 3 GNYE 1 2 3 GNYE
OPEN CLOSE
LATERAL DOOR LATERAL DOOR
+JB2
PE
PE 013.8:D / M203 M203 / 041.6:E
-X1 151 152 153 154 155 156

PE PE

-W315 1 2 3 GNYE -W316 1 2 3 GNYE


E E

U1 V1 W1 PE U1 V1 W1 PE

-M605 M -M606 M
400V, 0,25 kW, 1.03A 400V, 0,25 kW, 1.03A
Cosphi 0,63, 685 rpm
3 Cosphi 0,63, 685 rpm
3
LATERAL DOOR LATERAL DOOR
INLET OUTLET
1/L1 2/T1 /031.1:B 1/L1 2/T1 /031.3:B
3/L2 4/T2 /031.2:B 3/L2 4/T2 /031.3:B
+LATERALDOORINLET +LATERALDOOROUTLET 5/L3 6/T3 /031.2:B 5/L3 6/T3 /031.3:B
13 14 13 14
21 22 /031.5:D 21 22 /031.5:D
F F
Printed: 2015-03-31
Previous page: 026 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 032 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Lateral door E60-7173 031
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001b.4:D / 122 031.8:A / P202 P202 / 033.1:A


+JB2
001b.4:D / 222 042.6:A / X483

A 001b.5:D / 322 042.6:A / X484 A

-X4 483 484 486 487 13


43 6 13
-F610 -D614 -Q611 -Q612
1/L1 3/L2 5/L3 43 31 -W424 -W425 /032.1:A /032.2:B /032.5:D 14 /032.6:D
SRS INLET 1 2 SRS OUTLET 1 2 44 8 14
-F610
0,63...1A MCB 44 32
SRS BN BU BN BU
-D614

/032.6:A
I> I> I> + - + -

2/T1 4/T2 6/T3


/032.7:A +SRS-S424 +SRS-S425
ELFI
SRS BK BK

+JB2
B -W424 3 -W425 3
B
6
13 IN -X4 485 488
7
9 R1 -W121 37 38
8
11 R2
-X4 485 488

S1 S2 17 18 22 23 24 25
1 2
-A1 I4.5 -A1 I4.6 -A0 I2.0 -A0 I2.1 -A0 I2.2 -A0 I2.3

SRS INLET SRS OUTLET THERMAL OVERLOAD ELFI SRS SRS


ENDPOINT SENSOR ENDPOINT SENSOR SRS SRS FORWARD REVERSE

C C
SRS SRS
FORWARD BACKWARD
1/L1 3/L2 5/L3 1/L1 3/L2 5/L3
-A4 Q2.4 -A4 Q2.5
-Q611 -Q612
/032.5:D /032.6:D 6 7
2/T1 4/T2 6/T3 2/T1 4/T2 6/T3

21 21
-Q612 -Q611
/032.6:D 22 /032.5:D 22

D A1 A1 D
-Q611 -Q612
x1 SRS A2 SRS A2
FORWARD REVERSE
-T613
10 TURNS x2
SRS
Current
transformator
PE:12
032.8:E / M203 M203 / 032.4:E
-X1 161 162 163

-W117 1 2 3 GNYE

E +JB2 E
-X1 161 162 163 PE

PE

-W317 1 2 3 GNYE

+SRS
1/L1 2/T1 /032.1:C 1/L1 2/T1 /032.2:C
3/L2 4/T2 /032.2:C 3/L2 4/T2 /032.3:C
U1 V1 W1 PE
5/L3 6/T3 /032.2:C 5/L3 6/T3 /032.3:C
-M610
0,18 kW, 0.56A
M 13 14 /032.7:A 13 14 /032.8:A
21 22 /032.6:D 21 22 /032.5:D
F Cosphi 0,77, 1350 rpm 3 F
SRS
Printed: 2015-03-31
Previous page: 031 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 033 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Media Carriage SRS E60-7173 032
1 2 3 6 7 8
1 2 3 4 5 6 7 8

032.8:A / P202 P202 / 034b.2:A


014.8:A / P205 P205 / 034b.2:A

001b.5:D / L123
A A
001b.5:D / L223
+WAVEPULSE
OPTIONAL FUNCTION
001b.5:D / L323
1/L1 3/L2 5/L3 WH
PRESENT -S409
-F700 PROXIMITY
2,5A MCB SENSOR + -
WAVEPULSE WAVEPULSE BN BK
I> I> I> EXTERNAL
2/T1 4/T2 6/T3

+JB2
-W409 BN BU BK
B B
-X4 431 432 433

-W121 10 11 12
12 14 /005.4:A
-X4 431 432 433
-K701 11
/033.7:D
15 16 17
-A2 -A2 -A2
I6.3 I6.4 I6.5

WAVEPULSE WAVEPULSE WAVEPULSE


PROXIMITY RUNNING READY
C C
-D701 R S T
SENSOR
Altivar 312 L1 L2 L3 PE1 R1A R1C R1B R2A R2C CLI LI1 LI2 LI3 LI4 LI5 LI6 24V
0,37kW
POWER Common point C/O contact N/O contact of R2 Logic input Logic inputs
Variable Speed Drive of programmable relay R1 programmable relay common
WAVEPULSE

Logic input
switch RJ45
ENABLE WAVE
WAVEPULSE SPEED
SOURCE
DOWN
CLI

ATV312H037N4 SINK -A5 Q5.2 -A5 Q5.6


D Power supply 14 18 D
DC bus (+) Output to DC bus (-) for setpoint Analog voltage Analog I/O Analog current Analog voltage Analog voltage Analog current
DRIVE polarity braking resistor polarity potentiometer input common input input output output

T1 T2 T3 PE2 PO PA PB PC +10V AI1 COM AI3 AI2 AOV AOC


A1 A1
U V W + -
-K701 -K702
ENABLE A2 WAVE A2
WAVEPULSE SPEED
DOWN
033.8:E / M203 M203 / 033.6:E
-X6 601
-W120 1 2 3 GNYE SH -R3 x2
-R4 014.8:D / M205 M205 / 034b.5:E
10Kohm
8,45kOhm, 0,6kW
+JB2
x3 x1
E E
-X6 602

-X1 171 172 173 174

-W320 1 2 3 GNYE -R5


14 12
1,0kOhm, 0,4kW
-K702
/033.7:D 11
+WAVEPULSE
-X6 603
14 11 /033.4:B 14 11 /033.3:E
U1 V1 W1 PE 12 12

-M705 M
400VAC, 0,18kW
-PE
0,56A, Cosphi 0,77
3 Emc M20 Cableshields for motordrives
F WAVEMAKER LAGER
Must be connected 360 degrees in both ends F
Printed: 2015-03-31
Previous page: 032 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 034b + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Wavepulse (Siemens) E60-7173 033
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001b.6:D / L124 033.8:A / P202 P202 / 035b.2:A

001b.6:D / L224 033.8:A / P205 P205 / 035b.2:A

A 001b.6:D / L324 A

1/L1 3/L2 5/L3


-F300
32A MCB
VFD 1
I> I> I>
12 14
2/T1 4/T2 6/T3
PE:14 -K309 11
10mm2 /034b.6:D

B B
R S T
-D302
Altivar 21 L1 L2 L3 PE1 FLA FLC FLB RYA RIC PLC F R RES P24
15kW, 30.5A
POWER Fault relay contact Speed attained External power Configurable Internal
FREQUENCY supply input logic inputs supply
CONVERTER
VFD 1 2 3

Selection of Voltage/current -A1 I3.0 -A1 I3.1


logic type selection RJ45

SW4 FM VIA VFD 1 VFD 1


VFD - Variable Frequency Device SOURCE V
RUNNING READY
PLC I
SW2 SW3
ATV212HD15N4 SINK

C Configurable Configurable Configurable


C
DC bus (+) DC bus DC bus (-) Internal supply analog/logic analog analog
DRIVE polarity connection polarity available input Common input output ENABLE
T1 T2 T3 PE2 PO PA PB PC PP VIA CC VIB FM VFD 1
U V W + - -A4 Q3.0
12

6mm2 -A0 16 20
A1
Ch0 zon1
PQW752
SET POINT -K309
D 0-10 V ENABLE A2 D
VFD 1

-X1 101 102 103 104 Shield

-W101 1 2 3 GNYE SH

+JB2 034b.8:E / M203 M203 / 034b.5:E

IMPORTANT !!! 033.8:E / M205 M205 / 035b.5:E

CONNECT SHIELD TO
-X1 101 102 103 104
E CABLE-GLANDS AT E
BOTH ENDS ACCORDING
-W301 1 2 3 GNYE SH
TO EMC-SPEC.

+VFD1

14 11 /034b.4:B
U1 V1 W1 PE
12
-M304 M
FAN 1
15kW - 27,5A 3
F 400V/50Hz, Cosfi 0,91 F
Printed: 2015-03-31
Previous page: 033 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 035b + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram VFD 1 E60-7173 034b
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001b.6:D / L125 034b.8:A / -P202 P202 / 036b.2:A

001b.6:D / L225 034b.8:A / P205 P205 / 036b.2:A

A 001b.6:D / L325 A

1/L1 3/L2 5/L3


-F310
32A MCB
VFD 2
I> I> I>
2/T1 4/T2 6/T3 12 14
PE:15
10mm2 -K319 11
/035b.6:D

B B
R S T
-D312
Altivar 21 L1 L2 L3 PE1 FLA FLC FLB RYA RIC PLC F R RES P24
15kW, 30.5A
POWER Fault relay contact Speed attained External power Configurable Internal
FREQUENCY supply input logic inputs supply
CONVERTER
VFD 2 28 29

Selection of Voltage/current -A0 I2.6 -A0 I2.7


logic type selection RJ45

SW4 FM VIA
VFD 2 VFD 2
VFD - Variable Frequency Device SOURCE V
RUNNING READY
PLC I
SW2 SW3
ATV212HD15N4 SINK

C Configurable Configurable Configurable


C
DC bus (+) DC bus DC bus (-) Internal supply analog/logic analog analog
DRIVE polarity connection polarity available input Common input output ENABLE
T1 T2 T3 PE2 PO PA PB PC PP VIA CC VIB FM VFD 2
U V W + - -A4 Q2.7
9

6mm2 -A0 18 20
A1
Ch1 zon2 SET POINT
PQW754
-K319
D 0-10 V D
A2

-X1 105 106 107 108 Shield

-W102 1 2 3 GNYE SH

+JB2 035b.8:E / M203 M203 / 035b.5:E

IMPORTANT !!!
034b.8:E / M205 M205 / 036b.5:E

CONNECT SHIELD TO
E -X1 105 106 107 108 E
CABLE-GLANDS AT
BOTH ENDS ACCORDING
-W302 1 2 3 GNYE SH
TO EMC-SPEC.

+VFD2

14 11 /035b.4:B
U1 V1 W1 PE
12
-M314 M
FAN 2
15kW - 27,5A 3
F 400V/50Hz, Cosfi 0,91 F
Printed: 2015-03-31
Previous page: 034b = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 036b + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram VFD 2 E60-7173 035b
1 2 3 6 7 8
1 2 3 4 5 6 7 8

001b.7:D / L126 035b.8:A / P202 P202 / 041.1:A

001b.7:D / L226 035b.8:A / P205 P205 / 041.1:A

A 001b.7:D / L326 A

1/L1 3/L2 5/L3


-F320 97 97
65A MCB -F323 -F325
VFD 3
/036b.1:D 98 /036b.3:D 98
I> I> I>
12 14
2/T1 4/T2 6/T3
PE:16
25mm2 -K329 11
/036b.6:D

B B
R S T
-D322
Altivar 21 L1 L2 L3 PE1 FLA FLC FLB RY RC PLC F R RES P24
30kW, 58.5A
POWER Fault relay contact Speed attained External power Configurable Internal
FREQUENCY supply input logic inputs supply
CONVERTER
VFD 3 6 7 8 9

Selection of Voltage/current -A1 I3.4 -A1 I3.5 -A1 I3.6 -A1 I3.7
logic type selection RJ45

SW4 FM VIA VFD 3 VFD 3 THERMAL THERMAL


VFD - Variable Frequency Device SOURCE V
RUNNING READY OVERLOAD OVERLOAD
PLC I
SW2 SW3
VFD 3 1:ST VFD 3 2:ND
ATV212HD30N4 SINK
-M324 -M326
C Configurable Configurable Configurable
C
DC bus (+) DC bus DC bus (-) Internal supply analog/logic analog analog
DRIVE polarity connection polarity available input Common input output ENABLE
T1 T2 T3 PE2 PO PA PB PC PP VIA CC VIB FM VFD 3
U V W + - -A4 Q3.1
SET POINT 13

0-10 V

-F323 -F325 -A6 3 6


A1
/036b.7:B
6mm2 /036b.8:B Ch0 zon3
PQW304
SET POINT -K329
23..32A MCB THERMAL 1 3 5 23..32A MCB THERMAL 1 3 5
D MOTOR PROTECTION MOTOR PROTECTION
0-10 V ENABLE A2 D
FAN3 -M324 FAN4 -M326
6mm2 VFD 3
2 4 6 2 4 6
-X1 112 Shield -X1 116 Shield

-W103 1 2 3 GNYE SH -W104 1 2 3 GNYE SH

036b.8:E / M203 M203 / 036b.5:E


+JB2
035b.8:E / M205 M205 / 041.6:E
IMPORTANT !!!

E -X1 109 110 111 112 -X1 113 114 115 116 CONNECT SHIELD TO E
CABLE-GLANDS AT
BOTH ENDS ACCORDING
-W303 1 2 3 GNYE SH -W304 1 2 3 GNYE SH TO EMC-SPEC.

+VFD3

14 11 /036b.4:B
U1 V1 W1 PE U1 V1 W1 PE
12
-M324 M -M326 M
FAN 3 FAN 4
15kW - 27,5A 3 15kW - 27,5A 3
F 400V/50Hz, Cosfi 0,91 400V/50Hz, Cosfi 0,91 F
Printed: 2015-03-31
Previous page: 035b = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 041 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram VFD 3 E60-7173 036b
1 2 3 6 7 8
1 2 3 4 5 6 7 8

036b.8:A / P202 P202 / 042.1:A


036b.8:A / P205 P205 / 042.1:A
A 001b.3:D / 120 A
+JB2 +BED1
001b.3:D / 220 -W411 BK BN BU BU BN
- +
-S411
001b.3:D / 320 -X4 436 434 435 10-60 VDC
PROXIMITY SENSOR BK
BED1
1/L1 3/L2 5/L3
-W121 15 13 14
-F400 /005.4:A
3
6,3A MCB -X4 436 434 435
BED 1
I> I> I> -S111 4 12 14 12 14 12 14 12 14
2/T1 4/T2 6/T3 Reset
Bed VFD:s
B -K403 11
-K405 11
-K406 11
-K407 11
B
PE:19 /041.6:D /041.7:D /041.7:D /041.8:D

-D402
24VDC 24V LI51 LI52 LI53 LI54 LI55 12 13
CONTROLLER
INSIDE COM AO52 COM A051 A052 COM AI51 LO56 LO55 LO54 LO53 LO52 LO51 LI60 LI59 LI58 LI57 LI56
-A1 I4.0 -A1 I4.1
CARD
BED 1
BED1 BED1
RUNNING READY
BEDRESET / 042.1:A

C R S T C
-D401
Altivar 71 L1 L2 L3 PE1 R1A R1C R1B R2A R2C P24 0V LI1 LI2 LI3 LI4 LI5 LI6 +24V PWR CHOICE 1 CHOICE 2 CHOICE 3
3kW, 7.8A
ENABLE
Frequency
POWER Common point C/O contact
of programmable relay R1
N/O contact of R2
programmable relay
Input for external
+24V control
Logic input
common
Programable logic inputs Programable
logic input
Logic input
power supply
Power removal
safety function BED 1 BED 1 BED 1 BED 1
converter power supply or input
BED1 Input for PTC
probes -A4 Q3,4 -A4 Q3.6 -A4 Q3.7 -A5 Q4.0
LI6 input Logic input 16 18 19 2
-U400 Filter settings switch switch RJ45

Handpanel SW2 SW1


for ATV61/71 Normal PTC Source

IT system LI Sink Ext


A1 A1 A1 A1
Sink Int
-K403 -K405 -K406 -K407
VFD - Variable Frequency Device Analog
voltage/current ENABLE A2 CHOICE 1 A2 CHOICE 2 A2 CHOICE 3 A2
D DC bus (+) Output to DC bus (-)
Power supply
for reference
Analog
voltage/current Analog I/O
output
or Analog I/O
BED1 BED1 BED1 BED1 D
DRIVE polarity braking resistor polarity potentiometer Differential analog input AI1 input common Logic output common

T1 T2 T3 PE2 PO PA PB PC +10V AI1+ AI1- AI2 COM AO1 COM

U V W + -

-W118 1 2 3 GNYE SH
Bromsmotstånd
100 ohm 50W
031.8:E / M203 M203 / 042.6:E

036b.8:E / M205 M205 / 042.6:E


+JB2

E /033.2:E E
IMPORTANT THAT Movement: Relay: -K405 -K406 -K407
-X1 181 182 183 184 SHIELDS ARE CONNECTED Forward
TO EMC CABLE GLAND
Reverse
-W318 1 2 3 GNYE SH
Intermittent
Agitation
+BED1
14 11 /041.4:B 14 11 /041.4:B 14 11 /041.5:B 14 11 /041.5:B
U1 V1 W1 PE 12 12 12 12

M
-M402
400VAC, 1,1kW 3
F 2,55A, Cosphi 0,79 F
Printed: 2015-03-31
Previous page: 036b = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 042 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Bed 1 E60-7173 041
1 2 3 6 7 8
1 2 3 4 5 6 7 8

041.3:A / P202
041.3:A / P205
041.7:C / BEDRESET
A 001b.4:D / 121 A
+JB2 +BED2
001b.4:D / 221 -W412 BK BN BU BU BN
- +
-S412
001b.4:D / 321 -X4 439 437 438
10-60 VDC
X483 / 032.4:A PROXIMITY SENSOR BK
BED2
X484 / 032.4:A
1/L1 3/L2 5/L3
-F410 -W121 18 16 17
6,3A MCB
/005.4:A
BED2
I> I> I> -X4 439 437 438

2/T1 4/T2 6/T3


12 14 12 14 12 14 12 14
B B
PE:20 -K413 -K415 -K416 -K417
11 11 11 11
/042.6:D /042.7:D /042.7:D /042.8:D

-D412 15 16
24VDC 24V LI51 LI52 LI53 LI54 LI55
CONTROLLER -A1 I4.3 -A1 I4.4
INSIDE COM AO52 COM A051 A052 COM AI51 LO56 LO55 LO54 LO53 LO52 LO51 LI60 LI59 LI58 LI57 LI56
CARD
BED2
BED2 BED2
RUNNING READY

C R S T C
-D411
Altivar 71 L1 L2 L3 PE1 R1A R1C R1B R2A R2C P24 0V LI1 LI2 LI3 LI4 LI5 LI6 +24V PWR CHOICE 1 CHOICE2 CHOICE 3
3kW, 7.8A
ENABLE
Frequency
POWER Common point C/O contact
of programmable relay R1
N/O contact of R2
programmable relay
Input for external
+24V control
Logic input
common
Programable logic inputs Programable
logic input
Logic input
power supply
Power removal
safety function BED2 BED2 BED2 BED2
converter power supply or input
BED2 Input for PTC
probes -A5 Q4.1 -A5 Q4.3 -A5 Q4.4 -A5 Q4.5
LI6 input Logic input 3 5 6 7
Filter settings switch switch RJ45

SW2 SW1
Normal PTC Source

IT system LI Sink Ext


A1 A1 A1 A1
Sink Int
-K413 -K415 -K416 -K417
VFD - Variable Frequency Device Analog
voltage/current ENABLE A2 CHOICE 1 A2 CHOICE 2 A2 CHOICE 3 A2
D DC bus (+) Output to DC bus (-)
Power supply
for reference
Analog
voltage/current Analog I/O
output
or Analog I/O
BED2 BED2 BED2 BED2 D
DRIVE polarity braking resistor polarity potentiometer Differential analog input AI1 input common Logic output common

T1 T2 T3 PE2 PO PA PB PC +10V AI1+ AI1- AI2 COM AO1 COM

U V W + -

Bromsmotstånd
100 ohm 50W 041.8:E / M203
-W119 1 2 3 GNYE SH
041.8:E / M205

+JB2
E E
/033.2:E
IMPORTANT THAT Movement: Relay: -K415 -K416 -K417
-X1 185 186 187 188 SHIELDS ARE CONNECTED Forward
TO EMC CABLE GLAND
Reverse
-W319 1 2 3 GNYE SH Intermittent
Agitation
+BED2
14 11 /042.4:B 14 11 /042.4:B 14 11 /042.5:B 14 11 /042.5:B
U1 V1 W1 PE 12 12 12 12

M
-M411
400VAC, 1,1kW 3
F 2,55A, Cosphi 0,79 F
Printed: 2015-03-31
Previous page: 041 = RK Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: =BUILD_DOCUMENTS+2/2-003 + A1
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Circuit Diagram Bed 2 E60-7173 042
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

400 mm
+A2

50 mm
22,5 mm
B B

107,5 mm
-S419

C C

M25
400 mm

250 mm

-D20

D D

E 42,5 mm 315 mm 42,5 mm E

F F
Printed: 2015-03-31
Previous page: =RK+A1/042 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 2-004 + 2
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Layout +A2 OP-PANEL CABINET E60-7173 2-003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

750 mm
B B
+JB2

SIGNALS
C C
-T1

550 mm

BOTTOM
TOP

POWER
D D

E E

F F
Printed: 2015-03-31
Previous page: 2-003 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 2-005 + 2
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Layout +JB2 JUNCTIONBOX E60-7173 2-004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

A A

TOP

B B

300 mm

-S44 -S45 -S43


-H43

800 mm

C C

-S46

HINGE/LEFTSIDE

500 mm
RH

D D

BOTTOM

E 600 mm E

F F
Printed: 2015-03-31
Previous page: 2-004 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +5/5-001 + 2
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Layout +JB2 FRONT LAYOUT E60-7173 2-005
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: N


Last terminal in this line-up: PE
Total no. of terminals in this line-up: 3

B B

=RK+A1-X0
C C
PE
N

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: +2/2-005 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-002 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-001
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 101


Last terminal in this line-up: 163
Total no. of terminals in this line-up: 23

B B

=RK+A1-X1
C C
Shield

Shield

Shield

Shield
101
102
103
104

105
106
107
108

112

116

151
152
153
154
155
156
161
162
163

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-001 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-003 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-002
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: N101


Last terminal in this line-up: N106
Total no. of terminals in this line-up: 4

B B

=RK+A1-X2
C C
N101
N102
N103
N106

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-002 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-004 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-003
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 301


Last terminal in this line-up: 310
Total no. of terminals in this line-up: 10

B B

=RK+A1-X3
C C
301
302
303
304
305
306
307
308
309
310

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-003 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-005 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-004
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 351


Last terminal in this line-up: 494
Total no. of terminals in this line-up: 53

B B

=RK+A1-X4
C C
351
352
357
358
359
360
362
364
411
412
414
417
419
420
421
422
423
424
425
426
427
428
429
431
432
433
434
435
436
437
438
439
446
447
448
449
452
454
458
460
464
472
473
475
476
481
482
485
488
491
492
493
494
D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-004 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-006 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-005
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: -200


Last terminal in this line-up: -PE
Total no. of terminals in this line-up: 7

B B

=RK+A1-X5
C C
-200
-201
-202
-203
-204
-205
-PE

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-005 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-007 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-006
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 101


Last terminal in this line-up: 188
Total no. of terminals in this line-up: 37

B B

=RK+JB2-X1
C C
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
171
172
173
174
151
152
153
154
155
156
161
162
163
181
182
183
184
185
186
187
188
D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-006 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-009 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-007
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 352


Last terminal in this line-up: 494
Total no. of terminals in this line-up: 65

B B

=RK+JB2-X4
C C
352
353
354
355
356
357
359
360
361
362
363
364
411
412
413
414
415
416
417
418
419
420
427
428
429
430
431
432
433
434
435
436
437
438
439
446
447
448
449
452
453
454
455
458
459
460
461
464
465
471
472
473
474
475
476
483
484
485
486
487
D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-007 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: 5-010 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-009
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Terminal line-up diagram


A A

First terminal in this line-up: 352


Last terminal in this line-up: 494
Total no. of terminals in this line-up: 65

B B

=RK+JB2-X4
C C
488
491
492
493
494

D D

E E

IQF-Actual-Terminal_Line-up
F F
Printed: 2015-03-31
Previous page: 5-009 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: +9/9-001 + 5
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Terminal line-up E60-7173 5-010
1 2 3 6 7 8
1 2 3 4 5 6 7 8

Fuse table - 7173 Fuse table - 7173


DEVICE TAG: FUNCTION: MCB DEFAULT DEVICE TAG: FUNCTION: MCB DEFAULT
A LIMITS: SETTING: LIMITS: SETTING: A

A1 -F03 MCB 230V CONTROL VOLTAGE 6,3A


A1 -F101 MCB Maincontactor 4A
A1 -F102 MCB 24VDC CONTROL VOLTAGE 6A
A1 -F103 MCB VENTILATION CABINET 2A
A1 -F104 ILLUMINATION, OUTLET 10A, 30mA 25A/30mA
A1 -F105 4A
B B
A1 -F106 MCB OUTLET 4A
A1 -F200 MCB 24VDC Supply\PLC 2A
A1 -F201 MCB 24VDC Supply OP 2A
A1 -F202 MCB 24VDC Supply Digital inputs 2A
A1 -F203 MCB 24VDC Supply Digital outputs security 2A
A1 -F204 MCB 24VDC Supply Analog signals 2A
C A1 -F205 MCB 24VDC Supply Emergencystop/ Main24VDC 2A C

A1 -F300 MCB VFD 1 32A


A1 -F310 MCB VFD 2 32A
A1 -F320 MCB VFD 3 65A
A1 -F323 MCB THERMAL MOTOR PROTECTION FAN3 -M324 23..32A 27,5A
A1 -F325 MCB THERMAL MOTOR PROTECTION FAN4 -M326 23..32A 27,5A
A1 -F400 MCB BED 1 6,3A
D D
A1 -F410 MCB BED2 6,3A
A1 -F600 MCB Lateral door 1.6...2.5 A 2,2A
A1 -F602 MCB THERMAL MOTOR PROTECTION Lateral door Inlet gable 1..1,6 A 1,1A
A1 -F604 MCB THERMAL MOTOR PROTECTION Lateral door Outlet gable 1..1,6 A 1,1A
A1 -F610 MCB SRS 0,63...1A 0,63A
A1 -F700 MCB WAVEPULSE 2,5A
E E

F F
Printed: 2015-03-31
Previous page: +5/5-010 = BUILD_DOCUMENTS Rev.: Drawing nr.: Sheet Nr:
Without our written consent in each particular case, this document OCTOFROST AB Next page: + 9
must not - under penalty of law - be reproduced or improperly used
or handed over or otherwise communicated to a third party.
Volframgatan 3
SE-213 64 Malmö
SWEDEN
Phone: +46 42 33 22 60
Fax: +46 42 33 22 62
WWW.IQF.SE
Sheet:
Fuse table E60-7173 Fusetable_2_Mk2
9-001
1 2 3 6 7 8

You might also like