Professional Documents
Culture Documents
6000
p2a 20 9 NOS.
PIER PILE
ADDITIONAL BARS AT TOP
TO BE BUNDLED WITH p1a
12000
p2b 20 9 NOS.
p3 10 150 C/C.
p4 12 150 C/C. HELICAL STIRRUPS
500
p5 16 110 C/C.
800
500
c1a 8400 20 9 NOS.
BOTTOM REINFORCEMENT OF
c1b 20 9 NOS. PIER CAP
500
800
7650
1800
1800
1800
B B
200 200
8400
c2a 16 3 NOS.
SURFACE REINFORCEMENT
200 200
p5 p5
p5 p5 p5 c2b 7650 16 3 NOS.
PIER CAP
800
500
c3a 8400 20 9 NOS.
TOP REINFORCEMENT OF PIER CAP
c3b 20 9 NOS.
500
800
7650
1800
1800
1800
1400
s1 12 2L-200 C/C.
1000
p4 p4 300 THROUGHOUT
s2 16 2L-200 C/C.
2645
p4 p4 p4
600
s3 16 2L-200 C/C.
2645
AT GIRDER LOCATION
1000
s3a 16 2L-200 C/C.
2645
IN BETWEEN GIRDERS
p1 + p2a + p2b p1 + p2a + p2b
p1 + p2a + p2b p1 + p2a + p2b p1 + p2a + p2b
p3 p3
p3 p1 + p2b p3 p3
p1 + p2b p1 + p2b
p1 + p2b p1 + p2b
C C
p1 + p2b
p1 + p2b
D D
p1 p3 p1 p3
p1 p3 p3 p3
p1 p1
A
ELEVATION
SECTION A-A
Notes :
1. All dimensions are in millimeters and levels are in meter
unless otherwise specified.
2. Dimensions are not to be scaled, only written dimensions
p5 p3 p3
shall be followed.
p1 + p2a p1
3. Minimum clear cover for
p1 Pile cap - 50mm
p1 + p2b p1 + p2b
Pile - 75mm
4. Grade of concrete in.
Pile cap - M35
Pile - M35
5. Reinforcing steel shall be HYSD bars (Grade designation
Fe:500D) conforming to IS:1786-2008.
6. Bars shall be lapped in such way that not more than 50%
of the bars are lapped at any section. Lap length shall be
50xd where 'd' is the diameter of bar.
SECTION B-B SECTION C-C SECTION D-D 7. Earth face bar
8. Outer face bar
1ST STAGE CONSTRUCTION 2ND STAGE CONSTRUCTION
CONSTRUCTION JOINT
E
s2
s3
c3a
c2a s1
c1a c1b
E
c2a c3b c3a
c2b SECTION E-E
c1a c1b
s1 s1
C
L OF PIER C
L OF PIER C
L OF PIER C
L OF PIER
CONSTRUCTION JOINT 700 (MIN.)
c3a c3b s2
PIER CAP TOP REINFORCEMENT
s3a
c3b
c2b s1
C
L OF PIER C
L OF PIER C
L OF PIER C
L OF PIER
CONSTRUCTION JOINT 700 (MIN.)
c1b
SECTION F-F
c1a c1b
PIER CAP BOTTOM REINFORCEMENT