You are on page 1of 11

Application of the sciences of biology, chemistry, physics, engineering to the study of physiology, Dr.

Rheinhold Voll of the


human biofield … https://www.biologicalmedicineinstitute.com/reinhold-voll

BIOREGULATORY MEDICINE
HISTORY -
Reinhold Voll
BRMI is a
non-commercial website and does not specifically endorse any products or services mentioned in this biography (or on this site
generally).
Reinhold Voll, MD

University of Tübingen
Reinhold Voll was born in Berlin, Germany, on February 17, 1909. Though little has been recorded of his early life, his
father was an architect, and Reinhold decided to follow in his father’s footsteps. During his studies, however, his father
became ill, and Reinhold decided to change his focus to medicine so that he could aid in his father’s treatment. In 1935,
he interned at the Institute of Sports Medicine in Hamburg and graduated in medicine from the University of Tübingen,
one of Germany's oldest and most famous universities.
From 1938 to 1943, Dr. Voll focused on preventive medicine, tropical diseases and sports medicine. He also researched
homeopathy, traditional Asian iris diagnosis and cell therapy. Dr. Voll was introduced to methods of Chinese
acupuncture and traditional Chinese Medicine (TCM) by a doctor who worked in the tropics. He soon become fully
adept in the ancient Chinese practice of acupuncture. He had an idea that modern technology might enhance and
innovate acupuncture in the treatment of various chronic diseases. 
Electro-Acupuncture According to Voll
Around 1943, Dr. Voll moved to Plochingen where he worked as a family doctor. During the 1940s, he began
experimenting with the effects of electricity on the human body. He began using electric currents to enhance the effects
of traditional acupuncture. 
 
Dr. Voll, together with mechanical engineer Fritz Werner, constructed equipment, somewhat like the radio transistors
of the time, that allowed him to measure and record the electric conductive potentials of acupuncture points located in
the skin. He called this device “Diatherapunktteur.” This led him to develop a technique known as Electrical
Conductivity Metering (ECM). This diagnostic technique was based on TCM acupuncture meridians and acupuncture
points which became known as Electro-Acupuncture According to Voll (EAV). 

Today, the following are some current terms used to refer to ECM:

 Electrodermal Screening (EDS)


 Electrodermal Screening Test (EDST)
 Electrodermal Scanning
 Computerized EDS
 Meridian Assessment
 Energy Screening
 Bioelectric Functions Diagnosis (BFD)
 Bio-Resonance Testing (BRT)
 Bioenergetic Regulatory Technique (BER)
With his ECM device, Dr. Voll found that if he tested the electrical conductance on any general area of the human body,
there was a low level of electrical conductivity. He also discovered that at certain specific locations on the skin, the
electrical conductivity he measured was much higher (lower resistivity) than other locations. Many of these conductive
points found by Dr. Voll correspond to known acupuncture points lying along meridians. Since then, many other
researchers have also verified that electrical conductance at acupuncture points is significantly greater than the
surrounding tissue.

Dr. Voll and Fritz Werner continued to develop other EAV devices such as the Dermatron.

Dr. Reinhold Voll’s EAV-Dermatron


Dr. Voll then began a lifelong search to identify correlations between disease states and changes in the electrical
resistance of the various acupuncture points. He thought that if he could identify electrical changes in certain
acupuncture points associated with certain diseases, then he might be able to identify those diseases more easily, or
earlier, when treatment intervention was likely to be more effective.

Dr. Voll published a great deal of information about using acupuncture points diagnostically. (Until this time,
acupuncture points had been used primarily for treatment.) He found, for example, that patients with lung cancer had
abnormal readings on the acupuncture points referred to as lung points. Changes were also observed in the electrical
conductance of the acupuncture points supplying musculoskeletal structures that are inflamed. 
 
One day, he noted some unusual readings on certain acupuncture points with a patient who had a bottle of medicine in
his pocket. Dr. Voll would consistently get different readings when the bottle was in the patient’s pocket compared to
when it was not. At first, he was baffled as to how a closed bottle of medicine outside the body could affect the
acupuncture readings. It was even more baffling when he discovered that the glass bottle of medicine could change the
readings when it was in contact anywhere along the closed electric circuit involved with the testing procedure.
 
Voll and his colleagues then inserted a metal plate into the circuit and demonstrated that many substances that prelude
changes in acupuncture point readings when ingested could produce the same changes when placed on the plate (even in
closed glass bottles). They assumed that there must be electro-magnetic energy being emitted from the substances, and
that these energy fields somehow traveled along the electric circuit to the body.
 
Dr. Voll focused on certain criteria by which to treat these points. He determined that conditions were either
“inflammatory", "chronic", or "sub-chronic”. Using homeopathy, he was able to test if substances or remedies were in
resonance with the patient before the patient ingested them. Many of the remedies he tested were nosodes that he used
diagnostically. 
 
Nosodes are made from disease products. They are sterilized, tested for pyrogen-free, and potentized according to
homeopathic laws. They have been known for over 150 years and have been used as a cure especially in England and
France. In Germany, they have been used by doctors and therapists since the 19th century, and by EAV therapists for
about 30 years and with great success.
In short, Dr. Voll discovered that acupuncture points have distinct electrical properties when compared to surrounding
tissue. He initially identified 850 points on the hands and feet that corresponded to organs, glands and tissues. 
 
In the 1960s, the German physician Helmut Schimmel simplified the EAV procedure by reducing the number of
measurement points from the original 850 to 60. 
 
The German level and pressure instrumentation company VEGA Grieshaber manufactures the VEGA Bioexpert, which
allows for single point electrodermal screening. Now there are numerous companies that manufacture a wide variety of
electrodermal screening devices.

Some of these later EDS devices have become more computerized and even automated:
 
 https://www.asyra.co.uk/
 https://www.wegamed.de/en/
 https://www.holimed.com/
 https://www.moratherapeut.ch/en/praxis.html
 https://veradyne.com/
 https://www.regumed.com/bioresonance-for-doctors-naturopathic-practitioners/product.html
 http://www.auraanalyse.de/en/html/acupro_ii_system.html
 https://www.zyto.com/

The FDA generally classifies EDS machines as Class III devices requiring approval prior to marketing in the US. 
The bioelectrical impedance of acupoints seems to vary between healthy and diseased states.

Electroacupuncture According to Voll is a methodology that uses a calibrated ohmmeter to measure bioelectric impedance on
certain acupuncture points located on the hands and feet in response to changes in the physiological functions of organs and
structures of the body. This process also evaluates bioelectric impedance of acupuncture points when substances, such as
medicines, herbs, supplements, and homeopathic remedies and nosodes are placed in the same electrical circuit with the patient.
The EAV Technique
Hypotonia (0-40)
Normotonic (50)
Hypertonia (70-100)
Conductance (0-100)
EAV utilizes an electronic ohmmeter designed to measure the skin’s electrical resistance at specific acupoints. An EAV
device consists of a 12-microampere meter, calibrated from 0 to 100, with an electromotive force of 1.2 V. The
instrument has a high internal resistance because the electrical impedance of acupuncture points is lower, and the
conductivity is higher than in the contiguous skin. 
 
To take a measurement with this device, a patient holds the negative electrode in one hand and a physician presses the
probe (the positive electrode) onto specific acupoints mainly located on the hands and feet. The pressure applied to the
skin on the acupoint must be constant. Voll called this “electroacupuncture pressure”. It causes a stable electrical
resistance for the overall reading. 
 
With the probe applying a steady pressure onto an acupoint, if the reading on the meter goes to 50 (on a scale of 0 to
100), and stays stable at that position, this indicates that the organ or system associated with that acupoint is
energetically healthy. If the reading of the meter goes above 65 and stays stable at that position, it indicates that the
organ or system associated with that point is energetically “irritated”.
 
There are three basic levels of conductance at the topical points by a properly calibrated instrument: 

1. Normotonic: This reads "50" on a meter scale of 0-100. 

2. Hypertonia: These points exhibit conductance above 70 (to 100) on the meter scale. 

3. Hypotonia: These points exhibit conductance below 40 (to zero) on the meter scale. 

Theoretically, with high readings, the bioelectric resistance is low due to increased blood flow, which may be a sign of
inflammatory or allergic processes. However, when the initial reading, whatever it might be, decreases and settles at a
lower value on the scale, it is called an “indicator drop”, which suggests that the organ or system associated with that
acupoint is energetically unhealthy.

An indicator “drop” or “deflection” occurs in theory because the organs or systems being measured cannot generate a
bioelectric reaction to the initial electric measurement current transmitted by the probe to the acupoint. 
 
Although the indicator drop is the most significant sign in EAV, high readings over 65 should be further evaluated in
terms of treatment strategies to pursue when dealing with either inflammation or allergies in the clinical setting.
When organs have functional disturbances, the bioelectric resistance of the organ to the measurement current decreases.
This is because the organ is unable to maintain a fixed resistance with respect to the incoming current. This decrease in
bioelectric resistance is shown by the indicator deflection prior to the establishment of the equilibrium state between the
stimulation by the measurement current and the reaction capacity of the organ.

EAV does not “diagnose” - i.e., “determine the identity of a disease, illness, etc”. For example, an indicator drop on the
measurement point “descending colon” could mean anything from a bleeding polyp, to irritable bowel, to threadworm
parasitosis, to chronic constipation. The diagnosis is made by the doctor and confirmed with signs, symptoms,
laboratory and other functional and structural testing. Hence, EAV is a screening assessment. 

A rule or principle for evaluating measurements in EAV is to always take reference to the presenting history, signs and
symptoms. As a general rule, the larger the indicator drop, the more serious the condition. Slight indicator drops of the
needle, say, 5 or 10 points from maximum value, usually mean some incipient problem, but do not objectify the chief
complaint as a rule. Dramatic drops of the needle, 20 points or more, are remarkable and lead to the summating
criteria, i.e. the clinical impression. 

With his EAV system in place and capable of measuring acupoints in a reproducible fashion, Voll created his “medicine
testing”. He observed that indicator drops could be corrected, or “balanced”, when the right test substance was
introduced into the circuitry by being either placed on the plate or held by the patient.
 
Test substances, such as food supplements, homeopathic remedies, herbal products, or other substances, can be directly
placed on an aluminum plate (or well), or attached to the negative lead of the EAV device, which is also connected to the
patient through the negative electrode. In addition, test substances can be held by the patient in contact with the
patient’s body or in proximity with the patient’s “biofield or electromagnetic field.”
In 1979, Dr. Voll was awarded the Order of Merit from the Federal Republic of Germany.
Dr. Voll’s Later Work and Honors
In 1956, Dr. Voll established the International Medical Society for Electroacupuncture According to Voll (Internationale
Medizinische Gesellschaft für Elektroakupunktur nach Voll). This Society acts within the European Association of Medical
Associations of Specialized Therapies (ECPM) for the preservation of plurality in the field of medicine. 
 
Some EAV companies exist outside of Germany in Italy, Austria, Spain and the Czech Republic. Medical working groups on
EAV collaborate loosely with one another worldwide. 

Dr. Voll, in cooperation with the companies Staufen Pharma and Wala, developed “Nosoden tests”, which are test substances
for EAV screening manufactured in homeopathic dilution.

Dr. Voll also researched the TCM idea that teeth are energetically connected to organs. Numerous dental charts
depicting the interrelationship between teeth and organs have now been published. 
Interactive Tooth Meridian Chart
Click here to see how each tooth relates to the rest of the body.
Dr. Voll's Major Honors:
 
 In 1966, he was awarded the Vatican Gold Medal “For outstanding services to suffering humanity” by Pope Paul VI. 

 In 1974, he was Awarded the Hufeland medal and became an Honorary member of the Central Association of
Physicians for Natural Remedies. 

 In 1979, he was awarded the Order of Merit from the Federal Republic of Germany.
Dr. Reinhold Voll died on February 12, 1989 in Plochingen, Germany - 5 days short of his 80th birthday. 
 
Dr. Voll bequeathed us with a magnificent system of timely, inexpensive, and effective bedside evaluation. His discovery
continues to unfold in the realm of biophysics and energy medicine.
 Colbert, Agatha P., Keith Spaulding, Adrian Larsen, Andrew C. Ahn, and Janet A. Cutro. Electrodermal activity at
acupoints: literature review and recommendations for reporting clinical trials. Journal of acupuncture and meridian
studies 4, no. 1 (2011): 5-13.
 Dale, Ralph Alan. Demythologizing Acupuncture: Part 1, The Scientific Mechanisms and the Clinical Uses. Alternative
and Complementary Therapies 3, no. 2 (1997): 125-132.
 Eickhom, R., & Schimmel, H. W. (1999). Electrophysiological diagnosis at terminal points of acupuncture meridians.
 Fraser, Peter H., and Harry Massey. Decoding the human body-field: The new science of information as medicine.
Inner Traditions/Bear & Co, 2008.
 Gerber R, M.D RG. Vibrational Medicine: The #1 Handbook of Subtle-Energy Therapies. 3rd ed. Rochester, VT: Bear
& Company; 2001.
 Grigorova NG. Electro Acupuncture by Voll (EAV) and Homeopathy. S.l.: Milkana Publishing; 2012.
 Krop, J., G. T. Lewith, W. Gziut, and C. Radulescu. A double blind, randomized, controlled investigation of
electrodermal testing in the diagnosis of allergies. The Journal of Alternative and Complementary Medicine 3, no. 3
(1997): 241-248.
 Leonhardt, Horst, Helga Sarkisyanz, and Reinhold Voll. Fundamentals of Electroacupuncture according to Voll: An
introduction. Medizinisch-Literarische Verlagsgesellschaft, 1980.
 Qiao, Z. G., H. Vaerøy, and L. Mørkrid. Electrodermal and microcirculatory activity in patients with fibromyalgia
during baseline, acoustic stimulation and cold pressor tests. The Journal of rheumatology 18, no. 9 (1991): 1383-1389.
 Rubik, Beverly. Measurement of the human biofield and other energetic instruments. Mosby’s complementary &
alternative medicine: A research-based approach (2009): 61-87.
 Schimmel, Helmut W. Bewährte Therapierichtlinien bei chronischen Erkrankungen: 4. überarb. Aufl.-1985. PASCOE,
Wiss. Abt., 1985.
 Schuldt, H. Bioenergetics in Acupuncture and Electroacupuncture According to Voll. American Journal of
Acupuncture. 1978; 6(1): 17-22. 
 Scott-Morley, AJ and Reinhold Voll, The 850 EAV Measurement Points of the Meridians and Vessels including
Secondary Vessels. 1983.  
 Semizzi M, Senna G, Crivellaro M, et al. A double-blind, placebo-controlled study on the diagnostic accuracy of an
electrodermal test in allergic subjects. Clin. Exp. Allergy. June 2002;32 (6): 928-32. doi:10.1046/j. 
 Sundman, Eva, and Peder S. Olofsson. Neural control of the immune system. Advances in physiology education 38, no.
2 (2014): 135-139.
 VEGA Grieshaber
 Voll, Reinhold. Kopfherde: Diagnostik u. Therapie mittels Elektroakupunktur u. Medikamententestung. Med.-Literar.
Verlag-Ges., 1974
 Voll, Reinhold. Twenty years of electroacupuncture diagnosis in Germany. A progress report. Am J Acupunct 3, no. 1
(1975): 7-17.
 Voll, Reinhold. Topographische Lage der Messpunkte der Elektroakupunktur. Darstellung von 183 Meßpunkten der
Elektroakupunktur, von weiteren 90 klassischen Akupunkturpunkten, von 12 Meridianverläufen, von 3 Gefäßverläufen
und von Sekundärgefäßverbindungen des Lymphgefäße Paperback – 1976.
 Voll, Reinhold and Schuldt, Hartwig. Topographic Positions of the Measurement Points in Electro-Acupuncture
(Electroacupuncture): Textual, Volume I, 1977.
 Voll, Reinhold. Wechselbeziehungen von Odontonen und Tonsillen zu Organen, Störfeldern und Gewebesystemen.
Medizinisch-Literarische Verlagsgesellschaft, 1977.
 Voll, Reinhold. Interrelations of odontons and tonsils to organs, fields of disturbance, and tissue systems 1978.
 Voll, Reinhold. The Phenomenon of Medicine Testing in Electroacupuncture According to Voll. Am. J. Acupunctura 8,
no. 2 (1980).
 Voll, Reinhold. Measurement points of the electroacupuncture according to Voll on the hands and feet. Medizinisch-
Literarische Verlagsgesellschaft, 1982.
 Voll, Reinhold. Topographische Lage der Messpunkte der Elektroakupunktur nach Voll (EAV): Messpunkte für die
Steuerung des vegetativen Systems und des limbischen Systems auf 28 Tafeln dargestellt; Diagnostik und Therapie des
Vegetativums mit Krankengeschichten; die Basistherapie der EAV: Wiederherstellung der vegetativen Eutonie bei
chronisch entzündlichen und degenerativen Erkrankungen. Bild-u. Textbd. 3. Med.-Literar. Verlag-Ges., 1986.
 Voll, Reinhold. Medikamenttestung, Nosodentherapie und Mesenchymreaktivierung1990.
 Ward, Nicholas G., Hans O. Doerr, and Michael C. Storrie. Skin conductance: A potentially sensitive test for
depression. Psychiatry Research 10, no. 4 (1983): 295-302.
References

Video
Einführung in die Elektroakupunktur nach Dr. Voll, EAV. Teil 1 (German)
Einführung in die Elektroakupunktur nach Dr. Voll, EAV. Teil 2 (German)
Elektroakupunktur nach Voll (German).
La electropuntura nace de la experiencia en China del Dr. Voll y de su inquietud por registrar eléctricamente los diferentes
meridianos. En el apartado de testimonios conoceremos a Santiago, psicólogo de profesión, que nos cuenta cómo ha encontrado
en Energy una nueva forma de tratar el dolor. (Spanish)

You might also like