You are on page 1of 4

Safety Data Sheet 1/4

AQUALIC YS100

Date of issue : June 28, 2020

1. Product And Company Identification


Product Name AQUALIC YS100

Supplier Company Name Rakuto Kasei Industrial Co., Ltd.


Address 5-1, 4 Chome, Sekinotsu, Otsu-shi, 520-2277, Japan
Department In Charge Research and Development department
Telephone Number (81)77-546-0333
Fax Number (81)77-546-3158
Mail Address info@rakuto-kasei.co.jp

Manufacturer Company Name Nippon Shokubai Co., Ltd.


Address Kogin Blds., 4-1-1 Koraibashi, Chuo-ku, Osaka, Japan

Recommended Use Of The Product


And Restrictions On Use Industrial use (Scouring agent)
Arrangement Number 8006032

2. Hazards Identification
GHS Classification GHS
Physicochemical Hazards Flammable liquid Classification not possible
Toxicological Health Effects Acute toxicity (Oral) Classification not possible
Acute toxicity (Skin) Classification not possible
Skin corrosive / Irritation Classification not possible
Serious eye damage/eye irritation Classification not possible
Respiratory organs sensitization Classification not possible
Skin sensitization Classification not possible
Germ cell mutagenicity Classification not possible
Cancer-causing Classification not possible
Reproductive toxicity Classification not possible
Specific target organ toxicity – single exposure
Classification not possible
Specific target organ toxicity – repeated exposure
Classification not possible
Absorption respiratory organs toxicity Classification not possible
Toxicological environment effects
Aquatic environmental toxicity : acute Classification not possible
Aquatic environmental toxicity : chronic Classification not possible

Label Elements
Pictograms None
Signal Word None
Hazard Statement None

Instructions
Precaution Do not handle until all safety precautions have been read and
understood. Ware protective gloves/protective clothing/eye
protection/face protection.
First Aid Measures IF IN EYES : Carefully wash with plenty of soap and water. Remove
contact lenses, if present and easy to do. Continue rinsing.
Safety Data Sheet 2/4
AQUALIC YS100

IF ON SKIN : Wash with plenty of soap and water. Get medical


advice/attention if skin irritation or rash occurs. Collect spillage.
Storage Store in cool/well-ventilated place.

3. Composition Information On Components


Single Substance Or Mixture Mixture
Composition And Content

Sodium Polyacrylate CAS No. 9003-04-7 45%


Water CAS Nol 7732-18-5 55%

4. First Aid Measures


If Inhaled Remove victim to fresh air and keep at rest in a position comfortable for
breathing. Get medical advice in case of complaints.
If On Skin Wash with plenty of soap and water. Get medical advice/attention if
skin irritation or rash occurs.
If in eyes Rinse thoroughly with plenty of water for at least 15 minutes. Remove
contact lenses, if present and easy to do. Get medical attention.
If swallowed Clean mouth with water and afterwards drink plenty of water. Get
medical attention.

5. Fire-Finishing Measures
Suitable Extinguishing Media Dry chemicals extinguisher, CO2, Sand, Mist or Fire-extinguish foam
Prohibited Media No information available
Specific Hazards Arising From The Chemical No information available
Specific Methods Of Fire-fighting No information available
Protection For Firefighters Do fire-fighting from the windward avoiding inhalation of toxic gas.
Fighters should wear proper protectors (glove, glass, mask etc.).

6. Accidental Release Measures


Personal Precautions, Protective Equipment
And Emergency Procedures Wear proper protectors (glove, glass, mask etc.) while working. Ensure
adequate ventilation.
Environmental Precautions Prevent leakage or spillage to the river or sewerage.
Methods For Clean-Up Soak up with inert absorbent material (earth, sand, waste cloth etc.)
and wipe up the residue with waste cloth. Clean up with plenty of water.
Sweep up and shovel into suitable containers for disposal.
Preventive Measure For Secondary Accident Leaving the floor wet with the leakage may cause slipping accident.
Avoid walking on the wet floor. Keep the containers of salvaged
material tightly closed until processing it for disposal.

7. Handling And Storage


Handling
Technical Measures Avoid contact with skin, eyes and clothing. Avoid breathing vapors,
spray mists or sanding dust. In case of insufficient ventilation, wear
suitable respiratory equipment.
Storage Keep container tightly closed. Keep out of the reach of children.
Incompatible Materials No information available.

8. Exposure Controls / Personal Protection


Exposure Limits Not applicable
Engineering Measures Ensure adequate ventilation, especially in confined areas.
Personal Protective Equipment
Eye/Face Protection Safety glasses with side-shields.
Safety Data Sheet 3/4
AQUALIC YS100

Skin Protection Protective gloves and impervious clothing.


Respiratory Protection In case of insufficient ventilation wear suitable respiratory equipment.
Hygiene Measures Avoid contact with skin, eyes and clothing. Remove and wash
contaminated clothing before re-use. Wash thoroughly after handling.

9. Physical And Chemical Properties


Physical State Liquid
Color Pale yellowish clear
Odor Slightly characteristic odor
Odor Threshold No information available
pH 6.5-9.0 (Undiluted)
Boiling Point (°C) Approx. 102
Melting Point (°C) <=-20
Decomposition Temperature (°C) No information available
Flash Point (°C) Not applicable
Autoignition Temperature (°C) Not applicable
Explosion limit Not applicable
Specific Gravity 1.34 (25°C)
Water Solubility Soluble in water
Solvent Solubility No information available
Viscosity (mPa.s) No information available
Pour-point (°C) No information available
Ionicity Anionic

10. Stability And Reactivity


Chemical Stability Stable under normal conditions
Reactivity No self reactivity, May react with strong oxidant.
Condition To Avoid Prevent from mixing with incompatible materials
Incompatible Materials Strong oxidant
Hazard Decomposition Products No information available
Possibility Of Hazardous Reactions No information available

11. Toxicological Information


ATEmix (oral) LD50: 2000 mg/kg (Rat)
ATEmix (dermal) LD50: >2000 mg/kg (Rat)
Skin Corrosive / Irritation None [Rabbit]
Serious Eyes Damage / Eyes Irritation None [Rabbit]
Respiratory Organs Sensitization
And Skin Sensitization No information available
Original Generative Cell Variation No information available
Carcinogenicity No information available
Reproduction Toxicity No information available
STOT - single exposure No information available
STOT - repeated exposure inhalation rat TCLo 10 mg/m3/6H/4W-I (Sodium Polyacrylate 100%)
Aspiration Hazard No information available

12. Ecological Information,


Ecotoxicity Effects The environmental impact of this product has not been fully
investigated.
Product Information
Acute Toxicity
Acute Hazard (Fish) LD50 (96hr) : 1000 ppm [Oryzias latipes]
Acute Hazard (Crustacea) No information available
Acute Toxicity To Aquatic Plants No information available
Persistence / Degradability No information available
Bioaccumulation / Accumulation No information available
Safety Data Sheet 4/4
AQUALIC YS100

Mobility In Environmental Media No information available


Others No information available
No information available

13. Disposal Considerations


Waste Disposal Method Dispose of in accordance with federal, state, provincial, and local
regulations. Local requirements may vary, consult your sanitation
department or state-designated environmental protection agency for
more disposal options.

14. Transport Information


UN Classification Not applicable
UN Number Not applicable
Specific Precautionary Transport Measures
And Conditions Before loading, make sure that no leakage happened. Avoid overturn,
fall-down, direct sunlight and any other damage both on loading and
transporting.

15. Regulatory Information


International Inventories
TSCA: United States Registered
DSL: Canada Registered
National Regulations Of Japan
Notifiable Substance, Article 57-2,
Industrial Safety and Health Act Target Name Content Rate

16. Other Information


Prepared by Rakuto Kasei Industrial Co., Ltd.
5-1, 4 Chome, Sekinotsu, Otsu-shi, 520-2277 Japan
Date of revision : 28-June-2020

Disclaimer
The information contained herein is presented in good faith and believed to be accurate as of the effective date shown above. This
information is furnished without warranty of any kind. Employers should use this information only as a supplement to other
information gathered by them and must make independent determination of suitability and completeness of information from all
sources to assure proper use of these materials and the safety and health of employees. Any use of this data and information must
be determined by the user to be in accordance with applicable federal, provincial, and local laws and regulations.

You might also like