You are on page 1of 3

iSensL vMonitor TM

Creating the Digital Oilfield


Wireless Level Sensor

Benefits Applications

• Eliminate conduit and• Long Battery Life • Oil & Gas • Petro-Chemical
wiring• 200 wireless ◊ Well Head Monitoring • Water/Wastewater
• Handles Radar, transmitters can be ◊ Artificial Lift • Security
Magnetic, and Digital connected ◊ Tank Level
level sensors• Safe and Secure ◊ Pipe Line Monitoring
5th Generation Wireless Network

Technology

SENSOR TYPE SOFTWARE DETAILS


Single Point Liquid Level Float Sensor Operation Modes
• Top Mounted Liquid Level Switches • Continuous (Power)
• Side-Mounted Liquid Level Float Switches • Sleep (Battery operated)
Continuous Tank Level Indicator Timer/Clock
• Digital level Sensor • On-board
◊ For level Measurement 0 to 35 feet Communication Protocols
◊ +/- 1/8-inch accuracy • Wireless Messaging Protocol (WMP)
◊ Class 1 Div 1 Hazardous Areas • MODBUS RTU
• Radar – Level measurement Firmware
◊ For level Measurement 0 to 115 feet • Message Acknowledgements Verification (Guarantees mes-
◊ +/- 1/13-inch ( 2 mm) accuracy sage delivery)
◊ Class 1 Div 1 Hazardous Areas • 128 Bit Message Data Encryption
• Report by Exception
• System Diagnostics (Signal Strength, Message Count, etc)
WIRELESS • Network Registration & Authentication
• Raw data Engineering Units
• Type (Standard) 2.4 GHz: DSSS (direct Sequence Spread • Conversion/Scaling/Alarms
Spectrum) Line of sight 2.2 Km • 32 bit CRC Error Checking
• 900 MHz: ISM, FSK, FHSS (Frequency Hopping Spread • Battery level
Spectrum) Line of sight 10Km

POWER
• Input Range 8 -15 VDC
• Low Power Operating Mode with power consumption
<10 mA without radio

Abu Dhabi, U.A.E. - Tel: +971 2 6767 965, Fax: +971 2 6767 956, Houston, TX, U.S. Tel: +1 713 467 3900, Fax: +1 281 888 7626
info@vmonitor.com

© 2011 vMonitor, LLC, all rights reserved www.vMonitor.com


iSensL vMonitor TM

Creating the Digital Oilfield


Wireless Level Sensor

MECHANICAL SPECIFICATIONS
Operating Temperature
• -40°C to +85˚C (-40 ˚F to + 185˚F) with option of -40˚C
to +125˚C
• Humidity Range 5-95% non-condensing
General Dimensions
• 5.10” x 15.40” x 7.30” (W x H xD)
Mounting Type
• Direct Mount or Pipe Stand
Housing
• FM-approved and CSA certify for Explosion proof for
class1, Division 1, Groups A, B, C and Dust-Ignition proof
for class II/III, Division 1, Groups E, F and G; for hazard-
ous( Classified ) Locations, indoors and outdoors.
• Aluminum pressure die – casting, max 0,5% Mg
Optional Display LCD
• Optional Display with magnetic switch.
Antenna
• Hazardous Area Explosion Proof Antennas
• Gain 2DBi
• Certifications UL listed for the following locations: Class
I Div 1, Groups C, D -40oC ≤ Ta ≤ +85 oC, Class I Zone 1
AEx d IIb T5, Ex d IIB T5 -40oC ≤ Ta ≤ +85 oC. CE 0539
II2G Ex d IIB T5, DEMKO
• 08 ATEX 0727941X (see documents 35105 and 35106 for
safe installation)
Weight
• 4.5 Lbs
Certification
• ATEX II 2G Ex ib [ib] IIBT4

Abu Dhabi, U.A.E. - Tel: +971 2 6767 965, Fax: +971 2 6767 956, Houston, TX, U.S. Tel: +1 713 467 3900, Fax: +1 281 888 7626
info@vmonitor.com

© 2011 vMonitor, LLC, all rights reserved www.vMonitor.com